SVM F4. Node. Calculator. Installation Guide

Similar documents
SVM F4. Calculator. Manual

ABB Drives. User s Manual. Analogue I/O Extension Module RAIO-01

ABB Drives. User s Manual. Digital I/O Extension Module RDIO-01

ABB Drives. User s Manual Modbus Adapter Module FMBA-01

EA500. Installation Instructions Transponder

PTC/PT100 board 2.0 Option

Data sheet GCM MOD GMM EC.1 Communications module Modbus for GMM EC

INSTALLATIONSANVISNING INSTALLATION MANUAL INSTALLATIONS ANLEITUNG MANUEL D INSTALLATION RD-48 LV/HV. RS-422/485 Repeater Répéteur RS-422/485

EL731 PROFIBUS INTERFACE

ABB Drives. User s Manual. Modbus Adapter Module RMBA-01

Installation Instructions (KF-2000)

Dual channel temperature logger with two voltage inputs 0-5V Instruction Manual

UC102 basic version with display and knob UC102BL version with display, knob and backlight UC102DK version without knob and display

IV-30 Operating Manual for Pulse Distributor Cassette with potential separation

DUAL LOOP DETECTOR WITH MODBUS COMMUNICATIONS

COMFORT CONTROL CENTER SERVICE INSTRUCTIONS

M1600 Parallel Input / Output

RTT2 ROOM TEMPERATURE SWITCH. Mounting and operating instructions

CA-A480-A Elevator Controller. Reference & Installation Manual

Creone AB Box 148 S Tranås SWEDEN Tel: +46(0) Fax: +46(0) Internet: All data

Modem Installation and Networking Instructions

Expansion Module HZS 541-1S

RТTH DUAL ROOM SWITCH

StorEdge Wiring Guide & On Site Checklist for North America

mark150s mark150/485s DDC controllers Summary

Advant OCS. The Compact and Cost Effective Advant Controller. Advant Controller 210. Open Control System

Allen-Bradley Drives. Instructions. (For 6180 Industrial Computers)

ABB Drives. User s Manual Pulse Encoder Interface Module MTAC-01

ADC7520 SERIES. 1600W Battery Chargers and Power Supplies

ISOMETER isopv with coupling device AGH-PV

MVS RAIL ELECTRONIC FAN SPEED CONTROLLER. Mounting and operating instructions

Rako RAK4-R Instruction Manual

F1000 User's Manual. (Version: V1.01)

PQ V ac. CONTROL PANEL 230V FOR ROLLING SHUTTERS Instructions Manual. Control panel for electric rolling shutters 230Vac TECHNICAL FEATURES

PTC/PT100 board 2.0 Option

Line Coupler, MDRC LK/S 2.1, GH Q R0001

INSTALLATION INSTRUCTIONS

MC 11 EB-2 Power supply cabinet with external bus, AC version

See instructions to download and install the latest version of LinkBoxEIB and the user's manual at

Technical Datasheet clima RCM-FC 1. Product description

Operating instructions I / 2010

RST ROOM TEMPERATURE TRANSMITTER. Mounting and operating instructions

Hardened Ethernet Switch. Signamax Connectivity Systems. Hardened Ethernet Switch. Model G Series. User s Guide

PTC/PT100 board 2.0 Option

The Programmable 4-Way Relay Card is an optional peripheral unit that provides four individually programmable relay output circuits.

iconverter 1-Module Redundant Chassis

MAXIMA+ Series Rotary Level Indicator

LCD LCDS LCDRI CONTROLLER OPERATING MANUAL

I/O SIGNAL CONDITIONER

2001VT Temp & CO 2. - air quality sensor/controller NOTE!!! Manual for Installation. General. SenseAir AB

WARNING!!!!!!!!! IMPORTANT INFORMATION: READ BEFORE INSTALLATION!

POSITION MONITOR USERS MANUAL POM-M2 / POM-M3. Content

MAXIMA + Series ROTARY LEVEL CONTROL

RTU560 Connections and Settings DIN Rail RTU 560CIG10

CONTROLLERS TECHNICAL DATA SHEET

MAXIMA + Series ROTARY LEVEL CONTROL

Manual. Meter for BlueSolar DUO 12/24V-20A For RVs, Caravans and boats

See instructions to download and install the latest version of LinkBoxEIB and the user's manual at

REX F-0-9 Standalone or Access Controller

EXOcompact. Freely programmable controller

Rhino Buffer Module PSM24-BFM600S. Operating Instructions

Butterfly Laser Diode Mount

TRC ELECTRONICS, INC

ACS Stepper Controller. Econo Stepper Controller

DIGITAL DISPLAY. for Industry Applications. Series WAY-SSI. Key-Features:

Indication and Adjustment Product Information VEGADIS 61. Level Switching Pressure

MCU-9201MT22 venetian blind controller

M2400 Analog Output. Technical Description. Eiserstraße 5 phone 05246/ Verl fax 05246/ Date : Version : 2.

TPE, TPED Series 2000

IBS ST 24 BK-T INTERBUS-S. Data Sheet. Bus Terminal Module. Product Description

1. Introduction 1.1.Product Overview

Non-communicating room controllers

User Guide Automatic Transfer Switch (ATS)

DIGITAL INPUT/OUTPUT RELAY INTERFACE BMS-IFDD01E

SPA-ZC 200/SPA-ZC 202 IEC /SPA-gateway Modules. Installation Manual

USB-COM Plus ISO (USB-COMi SI-M)

WG 20. The WG 20 achieves an extraordinarily. accuracy for hazardous-area. applications.

high RESISTANCE STOPLIGHT Instruction Manual C-101EM

USER MANUAL. WBV412U01 AC voltage transducer

SIRIUS CAPACITOR MODULE User Manual. Model number: A-1.7C-M-SD-G Version 1.0; Release Date: April 2018

Product Data Sheet. BMS/Graphics Interface. Features

USER S MANUAL VER.1. C10D- PARALLEL PORT INTERFACE CARD BOARD Rev. 1

ADDENDUM FOR 20, 27, & 28 OPTIONS

Options for ABB drives, converters and inverters. User s manual FDIO-01 digital I/O extension module

DMX SwitchGate DIN SGD-1-8RD, SGD-1-8R16CD

Configurable Output Distribution. 120V / 208V / 240V 60Hz. User Manual English

See instructions to download and install the latest version of LinkBoxLON and the user's manual at

Buffered Power Supply PS-30DR v1.0

Operation Manual Profibus DP -Display HE 5120 P with digital I/O's

Rev Cutler-Hammer Smart Breaker Panel Control Manual

RXTH DUAL ROOM SENSOR / SWITCH

Switched Mode Power Supply Operating manual PAP800

Operating Manual UMB ISO Converter ISOCON Order Number: 8160.UISO

AB Axis Industries. Use

INTRODUCTION The Monitor, interchangeable modules and storage batteries are described below. Refer to the table below for specifications.

Wireless Sensor Adapter (WSA10) Installation Instructions

User Manual Entry Line Industrial Gigabit Ethernet High Power 60/95 W PoE Injector

1. Features. 2. Installation KNX INTEGRATION MODULE INT-KNX

EP/2 Installation Instructions

TSP-BCM48, TSP-BCM48A. Operating Instruction Manual. Page 1 of 13

Transcription:

SVM F4 Calculator Installation Guide Node

Installation guide for F4 For further information, also cf. the F4 manual Delivery The calculator is normally delivered in transport mode. In this mode only the system clock is active and no measurements are done. Transport mode is indicated by no in the upper left corner of the display. Prior to the installation the calculator must be activated, by pressing the Push-button in approximately 5 seconds the meter will normally go in to INIT -mode. In INIT -mode one can set the meter, see manual for further instructions. When exiting the INIT -mode the meter will enter normal mode ( operating mode ), the display will indicate 10 in the upper left corner. Connections Table 1 and Figure 1 shows how to connect the calculator. Mounting F4 is constructed for wall mounting. Terminal no according to EN1434 Signal descriptor 1 High Temp. sensor * 2 High Temp. sensor * 3 Low Temp. sensor * 4 Low Temp. sensor * 5 High Temp. sensor 6 High Temp. sensor 7 Low Temp. sensor 8 Low Temp. sensor 10 Flow sensor (+) 11 Flow sensor (-) 24 M-Bus interface 25 M-Bus interface 60 SIOX ** 61 SIOX ** Table 1, * Only used with 4-Wired method ** Only when option board SIOX is installed in card slot A. only A1 and A2 are connected to the SIOX loop. 5 1 2 6 7 3 4 8 10 11 24 25 Fig 5.2, Numbering of terminal according to EN1434, (numbering from left to right).

Circuit board F4 Option board slots F4 marking 2 Power ON/OFF, remove 4-Wire cables K2 and K3 for Power off Save data button, short circuit to store data Connection flow sensor. Flow sensor must be galvanic insulated. 2/4 Wire, jumper setting Connection of alarm output: D1 = + D2 = GND Fig. 2, Main circuit board F4 When common earth can be joined by the calculator through the pulse inputs, pulse outputs, flow input, temperature these inputs/ outputs must be galvanic separated. See F4 manual Zero Sequence current for more information.

Connection/handling Only option board marked with 2 may be installed on the F4. Connection flow sensors, temperature sensors and M-Bus See fig 1, mounting. The flow sensor must be galvanic isolated when using the calculator in M-Bus loop. See the F4 manual for more information. Pulse inputs IN 1 = + pulse input 1 IN 2 = + pulse input 2 IN = for both pulse inputs. ( jumpers are set according to markings on the main circuit board). Programming Warning: F4 may only be programmed with service program version 2.0 or higher Connection of mains The calculator is normally with mains supply. Connection of mains: Line to terminal marked L, neutral to terminal marked N and ground to terminal marked with ground symbol, see also fig.3 Pulse outputs UT 1 = + pulse output 1 UT 2 = + pulse output 2 UT = for both pulse outputs ( jumpers are set according to markings on the main circuit board). Alarm Connect + till terminal marked D1 and GND to D2. ( jumpers are set according to markings on the main circuit board). Save data By short circuiting the Save data the meter data are stored in a safe way. ( not all option board will store it s data upon this procedure). Power Off Remove the cables marked K2 and K3. Industrial applications When the F4 is being used in industrial applications or elsewhere with tough EMC conditions, the following recommendations must be observed to ensure a trouble-free operation of the calculator: Fig. 3, Connection board mains with back-up battery Use screened cables for the connection of temperature sensors. Connect the screen to the Ktterminal (terminal 11) in the calculator. On the temperature sensor end the screen should be left unconnected for best results. Install an option board for galvanic isolation of the M- Bus (FCR2 option board). When applicable, use a flow sensor with galvanic isolation.

Option board handling Extended functions can be added to the F4 meter by installing option boards. Only meters with mains power supply may be equipped with option boards. Check option board documentation for exceptions. Only option boards with the mark 2 may be used with the F4. See fig. 5.5. Only one (1) option board may be installed at the time, in order for the meter to recognize the option board. Option board installation procedure 1. Check option board, Marking 2 and which card slot can be used for option board and check correct jumper setting on option board, see table 5.5 2. Save data, using save key to short circuit the Save data button 3. Disconnect flow sensor connections by removing one flow sensor cable connected to terminal. 4. Cut power to main circuit board, remove 4-Wire cables K2 and K3 connected to mains 5. Remove jumpers on slot (only if required, check with option board manual) 6. Check DIP switch settings on option board 7. Install the option board carefully, do not bend any terminal pins. (Only one option board may be installed at the time). 8. Turn power ON, by connecting 4-Wire cables K2 and K3. 9. Check LED LD3 on the option board is turned off, this indicates proper installation of option board. Follow the steps 3-9 for installation of additional option boards. Note; only one (1) option board may be installed at the time. 10. Connect flow sensor The option board may only be installed in assigned slots, please consult option board documentation for further information. Option board affects battery life expectancy please check with ABB Metering or option board documentation when using a meter only powered by batteries. DIP-Switch setting of option board Slot BY 1 BY 2 BY 3 A X B X C X X D X E X X F Service (X) X X Table 5.5, DIP-Switch setting of option board for card slots, X ON, OFF, (X) insignificant Not all option boards can be combined check documentation for more information. 2 LED, LD3 Fig. 5.1., Option board Fig 5.2, Mark 2 for F4 Option Boards DIP Switches Metrima AB Norra Stationsgatan 93 SE-113 64 Stockholm Phone: +46 8 23 60 30 Fax: +46 8 23 60 31 www.metrima.se info@metrima.se 3-04-04E 071218/GSe