107VF Vibration Analyzer User s Manual

Similar documents
INSTRUCTION MANUAL. Portable Vibrometer: VM-3024S/H IMV CORPORATION

Vibration Analyzer, Data Collector & Dynamic Balancer

INSTRUCTION MANUAL. Portable Vibrometer: VM-7024H IMV CORPORATION

Vibration Tester. Test and Measurement Instruments C.C.

INTRODUCING. vb and SCOUT Series. from Bently Nevada * Asset Condition Monitoring

GE Measurement & Control. from Bently Nevada * Asset Condition Monitoring

VIBER X5. Vibration Measurement Instruments. Smart products for smart people

Complete User Guide. X1 Action Camera

GAOTek Vibration Meter with 2 Channel (High-Quality Accelerometer)

ST-140 Vibration Meter ST-140D Datalogging Vibration Meter User s Manual

STEP 1: GETTING STARTED

CXM FFT Analyzer. User guide. Rev

Vibration Analysis - Ethernet Interface

VIBXPERT Two-Channel FFT Data Collector and Vibration Analyzer

Advanced Test Equipment Rentals ATEC (2832)

Complete User Guide. Visit kaiserbaas.com for more information

VIBROTEST 80 & VIBROPORT 80 The Allrounders

Portable FFT Analyzer Model CF-7200

Portable equipment N130/N330 QUICK GUIDE BASIC OPERATIONS

MTN/VM220. Instruction Manual. High performance Vibration Meter. We reserve the right to alter specifications without prior notice.

MachineryMate 200 operating guide Handheld vibration meter

SVAN 974. Vibration ANALYSER USER S MANUAL

MANUAL TV-100 TV-100

VSEW_mk2-8g. Data Sheet. Dec Bruno Paillard

KI6501 Optical CWDM Power Meter. User Manual. KI6501 series Optical CWDM Power Meter

HOBO Motor On/Off Data Logger (UX90-004x) Manual

AK-C6A In Car Dash Camera. Instruction Manual Model Ref: MM347

Portable vibration calibrator Model 28959G

UNIDEN AUTOMOTIVE VIDEO RECORDER CAM 500

3 6 0 C A M E R A + + W W W. H O M I D O. C O M

DS-3000 Series Data Station Operation manual for Vibration Analysis

EVOBOOK 2. User s Manual.

Vibration Meter Instruction Manual

KI Channel Optical CWDM Power Meter. User Manual. KI6503 series 48-Channel Optical DWDM Power Meter

Features. Warnings and Precautions READ BEFORE OPERATING EQUIPMENT SAVE THESE INSTRUCTIONS

3-Axis G-Force Datalogger

VIBRATION METERS VX-54WH. Hand-Arm Vibration VX-54WB. Whole-Body Vibration VX-54WS. Habitability on Ships. 3-Axis Vibration Meter VM-54

Vibration Meter and Laser Combination Tachometer

BORESCOPE INSTRUCTIONS INSPECTION CAMERA RANGE RBS100 RBS200 RBS300. Retain these instructions for future reference

User's Manual. Car DVR Prestigio Roadrunner 520 with display

Wifi Action Camera T86. User Manual

Copyright 2013 DOD Tech All Rights Reserved

Technical Specification & Warranty mypos Europe Ltd. mypos Mini EN

Thanks for purchasing this EVOLVE 4000HD v2 Sport.

UMTI [UMTI USER MANUAL] User s Manual. Handheld Surveillance Thermal Camera

Operation Manual. Digital Vibration Tester. Model No. DVM-1000

Temperature & Humidity Datalogger

power quality Models 8230 & 8220

INSTRUCTION MANUAL VIBRATION ANALYZER VA Higashimotomachi, Kokubunji, Tokyo , Japan

Portable Video Laryngoscope

USER GUIDE. R10+ CAR DVR Your expert witness on board

Vibration Sentry RT. Data Sheet. May Bruno Paillard

Series IZH10. Handheld Electrostatic Meter. How to Order. Accessories and Option / Part Number for Individual Parts.

Digital MP3 & Video Player

Action-Sports Camera User Manual. Please read through the complete User Manual before using your JAKD

TALK 5H USER S MANUAL

Bearing (Shock Pulse) Condition Analyzer -110

Multi-functional Camera. Operating InstructionsV13.1. Note: Please read the manual carefully before using

IN-CAR HD Digital Video Recorder

VIBbox 64-Channel Sound & Vibration Solution

SECURITEST USER S MANUAL TABLE OF CONTENTS SAFETY PRECAUTIONS SAFETY INFORMATION... 2 WARNINGS... 28

Thermo-Anemometer Data Logger Model 1227

AGATE TECHNOLOGY AT-2030 OPERATORS MANUAL

Video Borescope Inspection Camera

DEUTSCH ENGLISH NEDERLANDS FRANÇAIS NORSK ITALANIO ČEŠTINA Hersteller DAB650SI

VIBBOX. 32, 48, or 64-Channel Sound & Vibration Solution Expansion to 256 Channels. Key Feature of Each VIBbox: Table 1. Key Features of VIBbox Models

3-Axis G-Force Datalogger

CAR BLACK BOX. Beyond Security. User Manual

User's Guide. Vibration Meter and Laser Combination Tachometer Model

// English. QCAMZ HD 720p 135 Wide Angle // Waterproof Action Cam

MIYAWAKI ULTRASONIC TESTER PM11 OPERATOR S MANUAL. Be sure to read this manual for safe and proper operation. Store this manual carefully after use.

Manual. User Reference Guide. Analysis Application (EMG) Electromyography Analysis

RADI-CEM. User manual. MPB S.r.l. Via Giacomo Peroni 400/ Rome - Italy. Tel Fax

X-Beam Waterproof Action Camera Light USER GUIDE

MINI MODEL NO: PTBMPCWX32

Rapid deployment surveillance system

H D D A S H C A M E R A

TEL: / FAX:

CAR DVR USER MANUAL AVDV-2800 DISTRIBUTED IN NEW ZEALAND BY: DIGITAL LOGISTICS GROUP LIMITED

Vibracord FX. The perfect equipment for your. measurement. Vibracord FX in aluminum case. Frequency response: Hz Hz

Axiomet AXB Safety instructions

Vibracord FX. The perfect equipment for your. measurement. Vibracord FX in aluminum case. Frequency response: Hz Hz

Technical Specification & Warranty mypos Europe Ltd. mypos Mini Ice EN

HS-620/630 Vibration Meter Kit Operating Manual

PowerPad. Three-Phase Power Quality Analyzer. Power Quality Analysis Made Easy! Model 8335

MINOX ACX 200 WiFi. Action Cam. Quick Reference Manual

EL-WiFi-TH -

CoCo-80 Quick Reference

TSR 3DXP and TSR 6DXP User s Manual May 2011

Windows " Intel Apollo Lake N3350 Clamshell Laptop

from P.R.Engineering Ltd Tel:

xtab 7Q Tablet PC User s manual

DC-204R DC-204Ra SMART DYNAMIC STRAIN RECORDER. 200kHz 2GB UPS. Strain DC voltage Temperature. TML Pam E-442B. capacity. High speed sampling

User Manual Revised 1-July-2015

0.01kV (0 to ±0.99 kv)

INFRARED CAMERAS THT

Trend-1 Vibration Data Logger. User Manual

The uscope Getting started

Drop-Off Release Transmitter

Copyright 2014 DOD Tech All Rights Reserved

Transcription:

2018 107VF Vibration Analyzer User s Manual

CONTENT General... 3 Safety Precautions... 3 Overview... 4 Kit Content... 4 Specifications... 4 Measurement functions... 5 Operation... 6 Keyboard... 6 Settings... 6 Date/Time... 7 Sensors... 7 Units... 8 Auto OFF... 8 Vibration... 9 Vibration measurement settings... 10 Taking measurements... 11 To save measurements... 12 Route based measurements... 13 Tachometer (107VF-T, 107VF-T2 only)... 14 Thermometer (107VF-T2 only)... 15

General Safety Precautions To prevent possible electrical shock, fire, personal injury or the device damage: Carefully read user s manual. Do not place sensor on the objects which exposed to high voltages. These voltages could cause personal injury or death. The Analyzer could not be used in potentially explosive environments. Take measures to prevent cables and straps become entangled by rotating part of machines at measurement site. Do not expose 107VF parts to heavy impacts, high humidity and extreme temperature. Do not try to open the display unit this can damage the system, and your after-sales service warranty will come void

Overview The 107VF Vibration Analyzer (Device, Analyzer) is a compact yet powerful, vibration analyzer designed to measure overall vibration parameters, FFT spectrum analysis of the rotating machinery, immediate evaluation against ISO 10816 standard, condition monitoring by route based measurements and data collection. Route files and data files exchange via email makes it ideal for data collection at remote sites. Simple in use, with free firmware upgrades, comes with data management and reporting software. Kit Content The 107VF kit includes: 107VF display unit; AC102-1A accelerometer, incl. cable 1.8m, magnet for curved surface mount; USB wall charger; USB cable; CD with ConSpect software and User s Manual; Carry case. Specifications Inputs IEPE or charge type accelerometers with known sensitivity, switchable. Optical RPM transducer with IR pyrometer sensor (optional) AD conversion 24 bits Frequency range 1 10000 Hz

Temperature measurement range -70 C to 380 C FFT spectrum resolution 400, 800, 1600 lines Data storage 4GB micro SD card PC interface USB Display color, sunlight readable 128x160 dots Battery Li-Po rechargeable, up to 8 hrs continuous operation Dimensions 132 x 70 x 33 mm Weight 150 g Measurement functions Vibration mode analyzer measures overall level of vibration acceleration, velocity and displacement and FFT spectrum, route or off-route measurements. Tachometer analyzer measures speed of rotation by means of contactless optical sensor. The measurement result is displayed in RPM and Hz. IR thermometer contactless measurement of object temperature. The measurement result is displayed in C and F.

Operation Keyboard OFF press and hold for 3 sec to turn device ON, short press to turn Enter, confirm selection, start measurement navigation arrow keys Menu backspace, quit option key Settings This menu is used to: - set Date/Time - Sensors setup - Units setup - Auto OFF delay setup

Date/Time Use arrow keys to set date. July 2018 Hold then press or for month decrement/increment. Confirm by when correct date is set. Use keys to set minutes and hours. Use key to switch focused field. Focused field is indicated by red frame. Confirm by when correct time is set. Sensors Use keys to choose sensor, which will be used for measurements. Drop down menu offers two types IEPE or charge type sensors to choose from. Confirm choice by key.

Type, S.N. and Sensitivity fields are editable. Use key to choose field to edit. Then use arrow keys to edit the field value. Units This option is not implemented yet.. Auto OFF Use keys to set auto OFF delay (minutes). Press or key to confirm and quit menu.

Vibration Analyzer measures vibration Acceleration, Velocity and Displacement. In ISO 10816 mode measurement result is compared to the built-in table of vibration severity grades according to ISO 10816-3. Use keys to choose measurement mode.

Vibration measurement settings Press Use Use key to enter Settings menu. to choose parameter to setup. to change parameter value. Low Freq lower frequency limit. Can be set to 1, 2, 10 Hz. Hi Freq upper frequency limit. Can be set: - from 200 to 10000 Hz for Acceleration; - from 200 to 5000 Hz for Velocity; - from 200 to 800 Hz for Displacement; FFT lines FFT spectrum resolution. Can be set to 400, 800, 1600 lines. Trigger not implemented yet.. Averaging measurement averaging. Can be set in range of 0 to 64. Zero means that averaging is OFF. Window weighting function. Can be set to Hanning or Rectangular.

Taking measurements Choose vibration parameter e.g. Velocity, edit settings if needed, then press measurement. key to start When measurement is running: Use key to toggle FFT spectrum / waveform display. Press key to stop/resume measurement. When measurement is stopped: Press key for Options: Save.. to save measurement data. Press to proceed. key Format Linear/Logarithmic amplitude display. Use to change parameter value. Zoom frequency axis display zoom change. Use parameter value to change

To save measurements Press Press key to stop measurement key for Options Choose Save.. and press key Device will enter My documents menu Browse to the destination folder, then press key save measurement. Device writes two files at a time FFT spectrum file and waveform file. Device remembers path to the last written files. To create new folder press default name for new folder. key. Date/time stamp is used as a To create folders with meaningful names connect device to the PC via USB as external flash drive, then create folders using PC keyboard.

Route based measurements Using ConSpect software create route file and download it to the device Go to Documents menu, move cursor to the route file and press key Use to browse route points Attach sensor at the measurement point and press key. Device takes measurement with preset parameters and saves files to proper destination folder

Tachometer (107VF-T, 107VF-T2 only) Connect optical probe to the device Enter Tachometer menu Aim optical probe to the rotating machine part with attached reflective tape. Press key to start/stop measurement. Device displays measurement result in RPM and Hz

Thermometer (107VF-T2 only) Connect optical probe to the device Enter Thermometer menu Aim optical probe to the machine. Press key to start/stop measurement. Device displays measurement result in C and F

NPP KOHTECT 73-V, Lomonosova str, of 38 Kiev 03189 Fax +38044 2577338 www.koh-tect.com