DATA SHEET nano DM60 Part number: 93N-6211/10x Digmesa AG, Keltenstrasse 31, CH 2563 Ipsach / Switzerland Phone 41 (32) 332 77 77, Fax 41 (32) 332 77 88 www.digmesa.com Version 02 Nano #93N-6211/10x GB Seite 1-5
General Description The nano DM60 Flow Sensor is a general-purpose device that has been specially designed for coffee machines that use vibratory pumps. The device is installed between the water tank and the vibration pump (on the suction side). This way measuring errors that arise during pulsating water flow caused by vibration pumps are minimized. Specific applications: Doubled isolation (liquid/electronics) according to the standard IEC/EN 60335-1: 2001/2002 A1: 04A2: 06A11: 04A12: 06. Approvals / Standards EN55014-1:00A1:01A2:02, EN600-6-3:01A11:04, IEC600-6-3:06(ed.2.0), EN600-3-2:06, IEC600-3-2:05(ed.3.0), EN600-3-3:95A1:01A2:05, IEC600-3-3:94A1:01A2:05(Cons.ed 1.2), EN55014-2:97A1:01, EN600-6-1:01, IEC600-6-1:05(ed.2), LFGB (EU 1935 /2004, EU/2011) Materials (wetted) Housing: PP (filled) Bearing pin: PP Nozzle: PP Ø 1.1 mm Turbine: PVDF Magnete: Ceramic Sr Fe O Technical data: Linear range: from 0.08-0.40 l/min Durability: min. 3000 liters at 0.4 l/min Resolution: 48 000 pulses/liter Pressure loss: 0.31 bar (4.49 psi) sucking at 0.40 l/min Measuring accuracy: /- 2.0% * Temperature range: 0 C to 65 C 32 F to 149 F Pressure range: -1 bar to 0.30 bar at 20 C -14.5 psi to 4.35 psi /68 F Mounting position: freely selectable Nozzle size: Ø 1.1 mm * Accuracy in the linear range for individually calibrated equipment Electrical connection ratings: Power supply: Consumption: <8 ma connection: Open collector NPN voltage: GND (saturation <0.7 V) load: max. 20 ma Leakage current: max. μa Connections: Pancon Hallcon plug (contact cycles max. 5x) : Square-wave output Duty Cycle: ~50% Dimensions in mm: 6.5 7.5 6 OUT 33 8 5.15 7.35 16.5 17 8 INLET identification IN 12.5 25 Option: Flow Sensor with Pancon Hallcon plug without cable item number: 93N-6211/101 Flow Sensor with Pancon Hallcon plug with cable, length 250mm item number: 93N-6211/102 RESISTANCE Special regulations which must be complied with by the flow sensor manufacturer apply to each country, e.g. CE, NSF, FDA and SK. The various media flowing through the flow sensor differ from application to application. You are advised to enquire with the medium manufacturer as to whether the entire installation and the flow sensor are resistant to the medium itself (see material)! ELECTRONIC DIGMESA electronic circuitry is always designed for operation with DIGMESA flow sensors. Please note the following if connecting to other electronic circuitry: The flow sensor does not supply an output voltage but switches the terminal to 0 V ground (actuated) or leaves it open (nonactuated) There must be a pull-up resistor between power supply and depending on electronic circuitry! We reserve the right to make modifications in the interests of technical progress. Version 02 Nano #93N-6211/10x GB Seite 2-5
Interface Connection: Examples Open Collector 4k7 0nF simple circuit 5 VDC 2k2 1N4148 0nF 1N4148 TTL output 5 VDC 4k7 Rx 0nF 3.0VDC Rx=750 5 VDC Rx=1k0 12 VDC Rx=4k7 2 Rx=k optocoupler interface We reserve the right to make modifications in the interests of technical progress. Version 02 Nano #93N-6211/10x GB Seite 3-5
Application example for household coffee machines Recommended tubing Material Silicon Dimensions Ø5.5mm x 2.0mm Hardness 50 Shore A Tube length between flow sensor and >14 cm pump Vertical mounting position is reccomended to allow air bubbles to pass through the flow sensor easily Avoid influence of strong magnetic fields for example from the pump (keep distance or add shielding) Secure tube before and after the flow sensor Tank We reserve the right to make modifications in the interests of technical progress. Version 02 Nano #93N-6211/10x GB Seite 4-5
Measurement Curve nano DM60 Druckabfall/pressure drop: nano DM60 Druckabfall/pressure loss [bar] 0.50 0.45 0.40 0.35 0.30 0.25 0.20 0.15 0. 0.05 0.00 0.00 0.05 0. 0.15 0.20 0.25 0.30 0.35 0.40 0.45 0.50 Durchfluss/flow rate [l/min] Medium: Water / Pressure: 1.0 bar Nozzle size Pulses/ Litres ml/pulse min. flow rate [l/min] max. flow rate [l/min] Pulse frequency [Hz] min/max Ø 1.1 mm 48 000 0.020 0.08 0.40 64 / 320 The values specified must be considered as approximate values. The number of pulses per litre may differ depending on medium and installation. We recommend to calibrate the number of pulses per litre in line with the complete installation. MEASUREMENT TIPS Ensure that there is no fast-pulsatory movement of the media Ensure that there are no reverse pressure surges Ensure that there is no air in the system Keep the pressure loss as small as possible Pay attention to the mounting position of the flow sensor Min/max flow should be in the linear range of the selected flow sensor Clean the system at appropriate intervals Avoid electrical voltage spikes Incorrect wiring of power supply, and ground will destroy the flow sensor Do not load electrical contacts mechanically Avoid moisture on the electrical contacts Avoid stray pick-up via the cable (Do not lay cables in parallel with high current loads) We reserve the right to make modifications in the interests of technical progress. Version 02 Nano #93N-6211/10x GB Seite 5-5