Similar documents
See instructions to download and install the latest version of LinkBoxMB and the user's manual at

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

See instructions to download and install the latest version of LinkBoxEIB and the user's manual at


See instructions to download and install the latest version of LinkBoxEIB and the user's manual at

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

See instructions to download and install the latest version of LinkBoxEIB and the user's manual at

See instructions to download and install the latest version of LinkBoxLON and the user's manual at

IntesisBox Modbus Server Panasonic

IntesisBox Modbus Server Fidelio IP

IntesisBox BACnet/IP Server DALI

IntesisBox Modbus Server KILSEN KSA-7xx. User s Manual 08/2013 r1.2 eng

IntesisBox KNX - BACnet/IP Client

IntesisBox KNX SAMSUNG NASA Air Conditioners

IntesisBox BACnet IP Server - M-Bus

IntesisBox Modbus Server - Honeywell XLS 80

IntesisBox Modbus Server - BACnet/IP Client

Gateway for integration of Modbus RTU slave devices into BACnet IP based systems.

Modbus Server SIEMENS Algorex (printer port)

ASCII Server - BACnet/IP Client. Gateway for integration of BACnet IP devices into ASCII enabled control systems.

IntesisBox Modbus Server LG Air Conditioning. User s Manual Issue Date: 06/2016 r1 eng

IBOX Modbus Server ESSER 8xxx/IQ8/FlexES fire panels

IntesisBox Modbus Server KNX

IntesisBox Modbus Server Siemens Synova FC330A

IntesisBox KNX - BACnet/IP Client

IntesisBox BACnet/IP Server Modbus TCP Master

IntesisBox BACnet/IP Server Modbus RTU Master

IntesisBox ME-AC-BAC-1

Modbus Server - M-Bus (EN ) Gateway for the integration of M-BUS meters with Modbus RTU and TCP based control systems.

---- IntesisBox KNX Modbus RTU Master and Modbus TCP Client

IntesisBox BACnet/IP Server M-Bus meters

IntesisBox Modbus Server M-Bus

IntesisBox Modbus Server - LON

8-Port IP40 IEEE802.3af PoE Unmanaged Industrial Switch User s Manual

Modbus Server - Mitsubishi Electric G50

IntesisBox KNX - AIRZONE

IntesisBox. KNX - Mitsubishi Electric G50. Gateway for integration of Mitsubishi Electric City Multi air conditioners into KNX control systems.

IntesisBox LON - KNX

F1000 User's Manual. (Version: V1.01)

IntesisBox KNX - Mitsubishi Electric G50

IntesisBox ASCII Server - KNX

Modbus Server - Mitsubishi Electric G50

IntesisBox Modbus Server BACnet MSTP and BACnet/IP client

Mid-span 802.3af PoE Injector. Installation Guide KPOE-100

Modbus Server - Mitsubishi Electric G50

DKG-210 UNIVERSAL INTERNET GATEWAY UNIT

Lantech. IPES /100TX with 4 PoE Injectors 24~48VDC Industrial Switch. User Manual

OTB1E0DM9LP I/O distributed module OTB - Ethernet TCP/IP m

4-port 10/100TX + 1 or 2-port 100FX Industrial Switch. User Manual

OTB1E0DM9LP I/O distributed module OTB - Ethernet TCP/IP m

INSTRUCTION MANUAL. Universal AC Input Switching Power Supply 24 Vdc Output DIN-Rail Models PSD1000, PSD1000F PSD PSD1000F

4 10/100/1000T Mini-GBIC with 4 IEEE 802.3at High Power PoE Industrial Wide Temperature Switch. User Manual SISTP LRT

8 10/100/1000T Industrial Switch. User Manual MS655208(X)

KFC-200. Installation Guide

Hardened Ethernet to VDSL2 Extender. User Guide. Revision History. Industrial Ethernet to VDSL2 Extender with Wide Operating Temp. Rev.1.

Hypercable injecteur HPOE - Industrial IEEE 802.3at Gigabit PoE Injector. User Manual. v.1.0 Jun Mail :

Rhino Buffer Module PSM24-BFM600S. Operating Instructions

Rhino Redundancy Module PSM24-REM360S. Operating Instructions

16- or 24-port Managed Switching Hubs

D6030S - D6030D INSTRUCTION MANUAL. D SIL 3 Switch/Proximity Detector Repeater Relay Output. Models D6030S, D6030D

IEC-0101FT Industrial 10/100TX to 100M-FX Slim Type Converter User Manual

Installation Manual INTELLIGENT SERVER. Model name: BMS-LSV6UL

Installation manual for for Schleifenbauer DPM3

Industrial 5-Port Fast Ethernet Switches with SFP Slot and optional 4 PoE PSE Ports. Basic Model: KSD-541 PoE Model: KSD-541-P. Installation Guide

Industrial 5-Port Fast Ethernet Switches. with SFP Slot and optional 4 PoE PSE Ports. Basic Model: KSD-541. PoE Model: KSD-541-HP. Installation Guide

KSD-800 Series. Installation Guide. Industrial 8-Port Fast Ethernet Switches with Fiber Connectivity DOC A -1-

Industrial Serial RS-232 to Fiber Converter. KSC-200 Series. Installation Guide

GSM-X. Communication module. Quick installation guide. Full manual is available on Firmware version 1.02 gsm-x_sii_en 08/18

Industrial Ethernet Switch

OTB1E0DM9LP I/O distributed module OTB - Ethernet TCP/IP m

IntesisBox KNX. Mitsubishi Electric G-50A/GB-50A/GB-50ADA/AG-150A. User's Manual Issue date: 03/08/2012 r21 eng

MC 11 EB-2 Power supply cabinet with external bus, AC version

IntesisBox Modbus Server BACnet/IP Client

INSTRUCTION MANUAL. SIL 3 Relay Output Module DIN-Rail Models D1092S-069, D1092D-069 D1092S D1092D-069

Satellite INSTALLATION GUIDE

RAD-DO8-IFS. I/O extension module, eight digital transistor outputs. Data sheet. 1 Description

Part No. Description Product Life Cycle Phase *) unit, 24 VDC, spring terminals. unit, 24 VDC, spring terminals, XC version

DTS 310. DIN Rail Mounted, Indoor Rated Revenue Grade Electrical Sub-meter. Page 1. Measurlogic MQ A

IntesisBox ASCII Server KNX

BACnet/IP Web Interface

TCNM-ACBB1 Installation Manual

Fieldgate SFG500. Technical Information. Intelligent Ethernet/PROFIBUS gateway

Rugged Industrial Media Converter

XBR V4 INSTALLATION AND USER GUIDE

INTELLIGENT SERVER. Model: BMS-LSV6E

XPSMCMCO0000EM Modbus TCPIP diagnostic expansion module with screw term

INSTALLATION INSTRUCTIONS FOR THE BV10-100/1000

RAD-DOR4-IFS. I/O extension module, 4 digital relay outputs. INTERFACE Data sheet. 1 Description

em4 Accessories Digital expansions

RAD-DI8-IFS. I/O extension module with 8 digital inputs or 2 pulse inputs. INTERFACE Data sheet. 1 Description

User Manual. MS657140X Industrial Fast Ethernet Switch 8x 10/100Base-TX

IntesisBox Modbus Server Mitsubishi Electric Centralized Controller TCP/IP XML. User Manual Issue Date: 01/2018 r1.0 EN

Web interface BACnet/IP

DPOM8-24/20 DIN RAIL POWER OVER MODBUS MODULE. Mounting and operating instructions

RТTH DUAL ROOM SWITCH

10/100/1000T to Mini-GBIC Industrial Switch Converter 10/100/1000T to 1000SX/LX Industrial Switch Converter. AMG9011G-H (-40 to 75C) User Manual

User Manual EKI-6528TI/ 6528TPI. EN port M12 Unmanaged/ PoE Switch with Wide Temperature

CoolPlug CooLinkHub HVAC Bridge. Quick Installation Guide

Chrome DIN Rail Power Supply 5V 7.5W 1 Phase (Class II & NEC Class 2) / DRC-5V10W1AZ

Transcription:

Safety Instructions WARNING Follow carefully this safety and installation instructions. Improper work may lead to serious harmful for your health and also may damage seriously the IntesisBox and/or any other equipment connected to it. IntesisBox must be installed by accredited electrician or similar technical personnel, following all the safety instructions given here, and in accordance always with the country legislation for installation of electric equipment. IntesisBox can not be installed outdoors or exposed to direct solar radiation, water, high relative humidity or dust. IntesisBox must only be installed in a restricted access location In case of wall mount, fix firmly IntesisBox on a not vibrating surface following the instructions below. In case of DIN rail mount fix IntesisBox properly to the DIN rail following the instructions below. Mounting on DIN rail inside a metallic cabinet properly connected to earth is recommended. Disconnect always power of any wires before manipulating and connecting them to IntesisBox. A power supply with an NEC Class 2 or Limited Source (LPS) and SELV rated is to be used. Respect always the expected polarity of power and communication cables when connecting them to IntesisBox. Supply always a correct voltage to power IntesisBox, see details of voltage range admitted by the device in the technical characteristics below. This device was designed for installation in an enclosure. To avoid electrostatic discharge to the unit in environments with static levels above 4 kv precautions should be taken when the device is mounted outside an enclosure. When working in an enclosure (ex. making adjustments, setting switches etc.) typical anti-static precautions should be observed before touching the unit Installation instructions Disconnect from mains the power supply before connecting it to IntesisBox. Disconnect power of any bus or communication cable before connecting it to IntesisBox. Mount IntesisBox on the wall or DIN rail following the instruction given below, respecting the safety instructions given above. Connect a NEC Class 2 or Limited Source (LPS) and SELV rated power supply to IntesisBox, respect the polarity if DC power or Line and Neutral if AC power. Apply always a voltage within the range admitted by IntesisBox and of enough power (see technical characteristics). Circuit-breaker must be used before the power supply. Rating 250V-6A Connect the communication cables to IntesisBox, see details on the user's manual. IntesisBox and the rest of devices connected to it. Configuration and setup Use the software LinkBoxBacnet to configure IntesisBox, follow the instructions of the user's manual for more details. See instructions to download and install the latest version of LinkBoxBacnet and the user's manual at /down/bacnet/linkboxbacnet.html 1 / 5

Wall mount 1. Separate the fixing clips in the bottom of the box, pushing them to the outside until hear the "click" which indicates that now the clips are in position for wall mount, see in the figure below. Botton view of the box Clips in their original position, for DIN rail mount Clips in position for wall mount 2. Use the holes of the clips to fix the box in the wall using screws. Use the template below for the wall holes. 61 mm Ø 3 mm Top view of the box IntesisBox www.intesis.com 100 mm DIN rail mount With the clips of the box in their original position, insert first the box in the upper edge of the DIN rail and later insert the box in the down part of the rail using a small screwdriver and following the steps n the figure below. Side view of the box 1 DIN Rail 3 2 2 / 5

Connections See Note 1 BACnet/IP + LinkBoxASCII + ASCII TCP See Note 2 Ethernet RJ45 - + CMN 24Vac 9-30Vdc Max.125 ma 24Vac Max.127mA 50-60Hz Ethernet BACnet/IP IntesisBox www.intesis.com ASCII EIA232 PC Console LinkBoxBacnet Only for configuration See Note 4 ASCII EIA232 See Note 3 Console Cable 1.8 m. Standard DB9F - DB9M. Supplied. Notes: 1. Must use NEC Class 2 or Limited Source (LPS) and SELV rated power supply. If using DC power supply: Respect polarity applied of terminals (+) and (-). Be sure the voltage applied is within the range admitted (9 to 30 Vdc). The power supply can be connected to earth but only through the negative terminal, never through the positive terminal. If using AC power supply: Make sure the voltage applied is of the value admitted (24 Vac). Do not connect any of the terminals of the AC power supply to earth, and make sure the same power supply is not supplying any other device. 2. BACnet/IP and ASCII TCP connection: If BACnet/IP and ASCII TCP communications are used simultaneously, use a straigh ethernet CAT5 cable connected to a hub or switch of the LAN of the building. If communicating through the LAN of the building contact the network administrator and make sure UDP traffic and the port used (47808 by default) are allowed through all the LAN path. If only BACnet/IP communication is used and the BACnet device is close to the IntesisBox, you can use a crossover ethernet CAT5 cable to connect directly the BACnet/IP controller to the connector ETH of IntesisBox. 3. ASCII EIA232 connection: Connect the cable coming from the programmable controller to the connector ASCII EIA232 of IntesisBox, this is a standard EIA232 Db9 male connector (DTE) in which only lines TX, RX and GND are used, see user's manual for details. Respect the maximum distance of 15 meters for this cable. 4. Use the software LinkBoxBacnet to configure IntesisBox. Consult the user's manual for details. 3 / 5

Technical characteristics Plastic, type PC (UL 94 V-0). Enclosure Dimensions: 107mm x 105mm x 58mm. Colour Light Grey. RAL 7035. 9 to 30Vdc +/-10%, Max.: 126mA. 24Vac +/-10% 50-60Hz, Max.: 127mA Must use a NEC Class 2 or Limited Source (LPS) and SELV rated power supply. Plug-in terminal block for power connection (2 poles). Terminal wiring (for power supply and low-voltage signals) Mounting Ethernet port 2 Per terminal: solid wires or stranded wires (twisted or with ferrule) 1 core: 0.5mm 2 2.5mm 2 2 cores: 0.5mm 2 1.5mm 2 3 cores: not permitted Wall. DIN rail EN60715 TH35. 1 x Ethernet 10 Base-T (RJ45). ASCII port 1 x EIA232. (DB9 male connector DTE). SELV 1 x. LED indicators 2 x ASCII port activity (Tx, Rx). 2 x Ethernet port link and activity (LNK, ACT). Console port EIA232. DB9 female connector (DCE). SELV Configuration Via console port. 1 Firmware Allows upgrades via console port. Operational temperature 0 C to +70 C Operational humidity 5% to 95%, non condensing Protection IP20 (IEC60529). RoHS conformity Compliant with RoHS directive (2002/95/CE). Norms and standards CE conformity to EMC directive (2004/108/EC) and Low-voltage directive (2006/95/EC) EN 61000-6-2 EN 61000-6-3 EN 60950-1 EN 50491-3 1 Standard cable DB9male-DB9female 1,8 meters long is supplied with the device for connection to a PC COM port for configuring and monitoring the device. The configuration software, compatible with Windows operating systems, is also supplied. 2 Ethernet port for the LinkBoxASCII, BACnetIP and/or ASCII TCP connection. 4 / 5

Dimensions External dimensions. + Ethernet port 58 mm ASCII EIA232 port Console port 107 mm 105 mm Free space recommended to install the device, with spacing enough for external connections. 100 mm 115 mm 130 mm 5 / 5