Series 3402 lightning EMP protectors Gas discharge tube (GDT) technology up to 2.5 GHz

Similar documents
Series 3400 lightning EMP protectors Quarter-wave stub technology

Series PC 3.5 precision subminiature connectors

SERIES MCX 50 MICRO MINIATURE CONNECTORS

SMA Series. Specification. Description. Applications Civil & Military Telecommunication Instrumentation SMA SMA. Interface Mating Dimensions

The Custom Interconnect Leader

SMP. Description. Compatibility. Content. Interface dimensions (mm/inches) SMP female. Interface dimensions conformable to the following standards:

SECTION 12 SSMA/SSMB/SSMC R121/R203/R202 SIMPLIFICATION IS OUR INNOVATON. Visit for more information

Cannon 50 Ohm Connectors

SMA - 50 Ohm Connectors

Mating Interfaces 1,63 (.064) 3,45 (.135) Ø3,71 (.146) MAX Ø6,61 (.260) MAX Ø3,71 (.146) MAX

Corona 70,000 Ft. Permeability Risetime Degradation (Mated Pair) 2.0 max MH z

SMA - 50 Ohm Connectors

Board-to-Board connections

Operating voltages up to 40 kvdc Operating current up to 30 Amps Advanced contact technology Silver plated and gold plated contacts available High

Series SMPM-T. Description. Compatibility. Content. Interface dimensions (mm/inches) SMPM-T male (pin contact), smooth bore

SMA Connectors Series

Prices, specifications, statement of warranty, and other terms and conditions are subject to change without notice by Lighthorse Technologies, Inc.

MCX Connectors. Alphabetical Index. Johnson Components P.O. Box 1732 Waseca, MN Fax:

INFORMATION TECHNOLOGY SYSTEMS SPDs FOR COAXIAL CONNECTION. DEHNgate Lightning current and surge arresters

SMA SERIES COAXIAL CONNECTORS

The Custom Interconnect Leader

TNC SERIES Miniature Coaxial Connectors

Our Most Important Connection is with You. SECTION 3. Board-to-Board: MMBX / SMP-MAX R223 / R222M

ndl-q & ndl-t SerieS CONNECTORS

In-Series and Between-Series Adapters SMA


SMP / SMP-COM / SMP-MAX series R222

SMA Series - Crimp Plug and Jack

Ganged Board to Board SMP Solutions. Catalog. belfuse.com/cinch

TT-2-PE- 24DC. Extract from the online catalog. Order No.:

SMP connectors. the easy connection. Products overview. Applications

Directory chapter 05. D-Sub Filter subminiature D connectors, 2.54 mm pitch

N Connectors Specifications Flexible Cable Semi-Rigid Cable Panel Mount Bulkhead In Series Adaptors...

TT-2-PE-M-24DC. Extract from the online catalog. Order No.:

PERFORMANCE SPECIFICATION ADAPTER, CONNECTOR, COAXIAL, RADIO FREQUENCY, (BETWEEN SERIES SMA TO SERIES TNC), CLASS 2, STRAIGHT PLUG

AXOMACH E-16. High data rate links for faster data transmission. Microwave coaxial cables. Panel mount connector QUASI-FLEX. Cable mount connector 2

spinner Getting started with

SMA Connectors. RF Coax Connectors. Product Facts

GMS Interconnect Series Product Information

Product Specification. Mezza-pede SMT Connector Low Profile 1.0mm Pitch

SMA. Precision 26.5GHz Connectors

Applications & Features, Type SSMP When using blind mate connectors in an application, careful consideration has to be given to choosing the right con

INCHES (MILLIMETERS) CUSTOMER DRAWINGS AVAILABLE ON REQUEST

PAGE 1/6 ISSUE SERIES Micro-SPDT PART NUMBER R516 X3X 10X R 516 _ 1 0 _

ASSEMBLY, INSTALLATION, AND REMOVAL OF CONTACTS AND MODULES

PT 2X2-24DC-ST. Extract from the online catalog. Order No.:

OSMP Microminiature Push-On Coaxial Connectors

Attachment plug with surge protection for coaxial signal interfaces. Connection: N connector, male/female

Product Performance Specification Mini Coaxial Connector

SPECIFICATION AND PERFORMANCE CHARACTERISTICS OF DVI MALE AND FEMALE CONNECTOR SERIES

2.92mm (SMK) Connectors

SMK Connectors. General Description. Contents (Click on any line to go to the indicated page) Test Data

CONTA-ELECTRONICS. CONTA-PROTECT overvoltage protection

160 PHOENIX CONTACT Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA Main Office: (650) Outside Local

SECTION 7 SMA/SMA-COM/BMA R125/R124/R128 SIMPLIFICATION IS OUR INNOVATON. Visit for more information

FISCHER MINIMAX TM SERIES

VITA 67 Series. Ideal For Blind Mate Applications. Electrical, Mechanical & Environmental Specifications

Standard Series Standard

Connectors. High Performance to 65 GHz. Applications. PDF Volume 1. Click Here for Table of Contents Click Here for Specifications

TT-ST-M-2-PE-24DC. Extract from the online catalog. Order No.:

Extract from the online catalog SFP 1-5/120AC Commercial data Product description Technical data Standards

SW IP67 Waterproof Series - Part Numbering

SECTION 1 IMP / UMP R107

PT 2X2-HF-24 DC-ST. Extract from the online catalog. Order No.:

HIGH AMPERAGE, SEALED/NON-SEALED, LOCKING/ NON-LOCKING POWER JACKS & PLUGS

PT 3-PB-ST. Extract from the online catalog. Order No.:

TT-UK5/ 24DC. Extract from the online catalog. Order No.:

FILTERS FOR DATA LINES

Rotary Position Technology Incremental Encoders

16 way 19 1½U enclosure with rear cable management tray NPGZM-16-NJ. ½U high front mounting cable management tray

>> Very good intermodulation performance SPECIFICATIONS. 3-way unbalanced 3DSS3U 3DSS3U-B. 3-way 3DSS3 3DSS3-B 3DSV

Modular Connector System with High Power, Signal, Fibre-Optic, Coaxial Contacts and Pneumatic Valves

M ISCELLANEOUS A CCESSORIES O BSTRUCTIONS LIGHTS MISCELLANEOUS ACCESSORIES OBSTRUCTION LIGHTS

Elma Bustronic CompactPCI Reference Sheet

SPECIFICATIONS ELECTRICAL SPECIFICATIONS - 3D-LINE SPLITTERS 3DSV3. unbalanced 3DSS3U

Fork light barriers SOOF

U7100 Pressure Transducer

HEMP & IEMI PROTECTION FILTERS FOR MAINS POWER LINES

Datamate High-Reliability Connectors

07. har-link Interface Connectors

RF Connectors Technical Data Sheet. Gold over Nickel Plated Brass Contact. Size 0.5 in [12.7 mm] . Weight lbs [2.27 g].

EN3 SERIES WEATHERTIGHT CONNECTORS NEW PRODUCT BULLETIN 602

Overvoltage Protection Devices

PT 5-HF- 5 DC-ST. Extract from the online catalog. Order No.:

LIGHTNING SIMPLY EXCEPTIONAL FILTER PROTECTION SERIES PRODUCT INFORMATION. Global BE PREPARED, BE PROTECTED.

11525A 11524A

RE22R1QMQ star-delta timing relay - 230VAC/440VAC - 1 C/O

Product Information. ECN 1023 EQN 1035 Rotary Encoders with EnDat 2.2 for Safety-Related Applications

PERFORMANCE SPECIFICATION SHEET CONNECTORS, COAXIAL, RADIO FREQUENCY, SERIES C (UNCABLED-RECEPTACLE, FEMALE, JAM NUT MOUNTED, HERMETIC SEAL, CLASS 2)

Surge Protection Devices Ex9UE2

Lightning Protection for Wireless Networks

RTX series EN

Absolute Encoders Multiturn

07. har-link INTERFACE CONNECTORS

PC Board Sockets. Specifications SOCKETS. Surface Mount, Single Piece construction. Throughboard, Two Piece construction. Materials.

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

Section 7: Contents. Section Item Pages. Connectors Thermocouple Power, Push-on and In-line MS Circular Power, High Voltage Coaxial

RE17LAMW on-delay timing relay - 1 s..100 h V AC/ DC - solid state output

RF Power Feed-Through Capacitors with Conductor Rod, Class 1 Ceramic

Features wideband, 10 to 4200 MHz low insertion loss, 0.6 db typ. feed through terminal per DC port

Transcription:

lightning EMP protectors Gas discharge tube (GDT) technology up to 2.5 GHz Description HUBER+SUHNER gas discharge tube protectors make the best of the traditional spark gap protection principle for general applications in electronics and adapt it perfectly to RF coaxial line applications. At their heart are specially designed gas discharge tubes. The available product range of GDT's enables a selection according to the RF transmission power with an optimum protection performance. A very important feature of the GDT protectors is the possibility to DC/AC power outdoor equipment via coaxial cable. products can be used broadband from DC to 2 GHz or even higher. They are generally designed as coaxial feed-throughs which allow the customer to build up a protected area according to the recommended and well-proven protection zone principle of IEC 62305. HUBER+SUHNER GDT protectors are designed such that the gas discharge tubes can be easily exchanged for new operation conditions or replaced in the case of a necessary service. Features Broadband DC to 2.5 GHz DC transmission Gas discharge tube replaceable Easy maintenance SEMPER self-extinguishing functionality optional (see page 113) Specifications Electrical data Requirements RF: Impedance 50 or 75 Ω Frequency range DC 2.5 GHz (some types different according to shown specification, but 2 GHz min.) RL* 20 db min. (exception F connectors) IL* 0.2 db max. (exception F connectors) RF power transmission according to selected gas discharge tube refer to page 134 Protection: Surge current handling capability Residual pulse voltage and energy 30 ka once and 20 ka multiple (8/20 µs test pulse) 8 ka (10/350 µs test pulse) for typical values refer to the following diagram * With 230 V gas discharge tube (9071.99.0547) 68 HUBER+SUHNER

Typical residual pulse for series 3402*, test pulse acc. to IEC 61000-4-5 1.2/50 µs 4 kv; 8/20 µs 2 ka: Residual pulse voltage: typ. 650 V Residual pulse energy: typ. 350 µj Residual Voltage [V] 800 700 600 500 400 300 200 100 0 * With 230 V gas discharge tube (9071.99.0547) -100-50 0 50 100 150 200 250 300 Time [ns] Mechanical data Requirements Coupling nut torque force according to IEC/MIL (refer to page 30) Durability (matings) Bulkhead mounting torque force: Mounting hole diameter 19 mm/ 3/4 " max. Larger than 19 mm 500 min. 20 Nm (14.7 ft-lb) min. / 25 Nm (18.4 ft-lb) max. 35 Nm (25.8 ft-lb) min. / 44 Nm (32.3 ft-lb) max. Environmental data Requirements/test conditions Operation temperature range 40 C...+ 85 C/ 40 F...+ 185 F Waterproof degree (IEC 60529) according to shown product specification, data refer to the coupled state Temperature shock MIL-STD-202, Meth. 107, Cond. B Moisture resistance MIL-STD-202, Meth. 106 Vibration MIL-STD-202, Meth. 204, Cond. D The product is designed to meet the cited test procedures. Any additional or different requirements arising from specific applications or environmental conditions not covered by the test specifications mentioned above are subject to request and need to be confirmed by the single product detail specification. We recommend additional taping for long term outdoor applications in any case. Material data Component part Material Plating Housings brass SUCOPLATE Male contacts brass gold or silver plating Female contacts CuBe2 gold or silver plating Insulators PTFE Gaskets elastomer rubber HUBER+SUHNER 69

Characteristic impedance 50 Ω Gas discharge tube normally to be selected and ordered separately refer to page 134-137 H+S type Frequency range (MHz) Connectors Unprotected/protected side* If bulkhead mount version, side of bulkhead marked «b». Mounting/ grounding MH - hole for «b» M - screw RL min. IL max. Waterproof Weight 3402.00.0032 DC 2000 7/16(f)-N(f), b MH12, M8 20 db 0.2 db IP65 190 g Fig. 1 Figure 3402.17.0043 DC 2500 N(m)-N(f), b MH12, M8 20 db 0.2 db IP65 230 g Fig. 2 3402.17.0044 DC 2500 N(f)-N(f), b MH12, M8 20 db 0.2 db IP65 230 g Fig. 3 3402.17.0072-EX** DC 2500 7/16(f)-7/16(f) MH25 20 db 0.2 db IP65 126 g Fig. 4 3402.17.A DC 2500 N(f)-N(f), b MH25 20 db 0.2 db IP65 126 g Fig. 5 3402.17.C DC 2500 N(m)-N(f), b MH25 20 db 0.2 db IP65 155 g Fig. 6 3402.41.0037 DC 2500 7/16(m)-7/16(f), b MH74, M8 20 db 0.2 db IP65 450 g Fig. 7 3402.41.0038 DC 2500 7/16(f)-7/16(f), b MH74, M8 20 db 0.2 db IP65 450 g Fig. 8 3402.41.0056-EX** DC 2500 7/16(f)-7/16(f) MH72 20 db 0.2 db IP65 390 g Fig. 9 3402.41.A DC 2500 7/16(f)-7/16(f), b MH72 20 db 0.2 db IP65 387 g Fig. 10 3402.99.0003 DC 2500 N-R(f)-N-R(f)*** MH25 20 db 0.2 db IP65 126 g Fig. 11 * Recommendation only, reverse installation possible without any impact on performance ** SEMPER type, GDT unit included for detailed information see page 113 *** Reverse interface (inner conductor pin, outer conductor as standard N(f)) All mounting holes are shown on pages 34 35. 70 HUBER+SUHNER

All dimensions in mm Fig. 1 Fig. 2 Fig. 3 Fig. 4 Fig. 5 Fig. 6 Fig. 7 Fig. 8 Fig. 9 Fig. 10 Fig. 11 HUBER+SUHNER 71

Characteristic impedance 75 Ω Gas discharge tube normally to be selected and ordered separately refer to page 134-137 H+S type Frequency range (MHz) Connectors Unprotected/protected side* If bulkhead mount version, side of bulkhead marked «b». Mounting/ grounding MH - hole for «b» M - screw RL min. IL max. Waterproof Weight 3402.18.A DC 1500 N(f)-N(f), b MH25 16.5 db 0.2 db IP65 126 g Fig. 1 1500-2000 15.5 db 0.2 db Figure 3402.27.0001 DC 1500 TNC(f)-TNC(f), b MH25 16.5 db 0.2 db IP65 195 g Fig. 2 1500-2000 15.5 db 0.2 db 3402.99.0004 0 1500 F(f)-F(f), b MH25 -- 0.5 db IP54 126 g Fig. 3 * recommendation only, reverse installation possible without any impact on performance All dimensions in mm Fig. 1 Fig. 2 Fig. 3 All mounting holes are shown on pages 34 35. 72 HUBER+SUHNER

Space for your notes HUBER+SUHNER 73