ANALYSIS AND COMPARISON OF SYMMETRY BASED LOSSLESS AND PERCEPTUALLY LOSSLESS ALGORITHMS FOR VOLUMETRIC COMPRESSION OF MEDICAL IMAGES

Similar documents
Compression of 3-Dimensional Medical Image Data Using Part 2 of JPEG 2000

Performance of Quality Metrics for Compressed Medical Images Through Mean Opinion Score Prediction

Image Quality Assessment Techniques: An Overview

Image Compression for Mobile Devices using Prediction and Direct Coding Approach

Lossless Predictive Compression of Medical Images*

Review and Implementation of DWT based Scalable Video Coding with Scalable Motion Coding.

Wavelet Based Image Compression Using ROI SPIHT Coding

Comparative and performance analysis of HEVC and H.264 Intra frame coding and JPEG2000

A Comparison of Still-Image Compression Standards Using Different Image Quality Metrics and Proposed Methods for Improving Lossy Image Quality

Reduction of Blocking artifacts in Compressed Medical Images

A COMPRESSION TECHNIQUES IN DIGITAL IMAGE PROCESSING - REVIEW

Perceptual Quality Assessment of Medical Images

Adaptive Quantization for Video Compression in Frequency Domain

Enhanced Hybrid Compound Image Compression Algorithm Combining Block and Layer-based Segmentation

SSIM based image quality assessment for vector quantization based lossy image compression using LZW coding

SSIM Image Quality Metric for Denoised Images

Features. Sequential encoding. Progressive encoding. Hierarchical encoding. Lossless encoding using a different strategy

ENHANCED DCT COMPRESSION TECHNIQUE USING VECTOR QUANTIZATION AND BAT ALGORITHM Er.Samiksha 1, Er. Anurag sharma 2

Optimized Progressive Coding of Stereo Images Using Discrete Wavelet Transform

CMPT 365 Multimedia Systems. Media Compression - Image

ISSN: An Efficient Fully Exploiting Spatial Correlation of Compress Compound Images in Advanced Video Coding

CHAPTER 6. 6 Huffman Coding Based Image Compression Using Complex Wavelet Transform. 6.3 Wavelet Transform based compression technique 106

International Journal of Emerging Technology and Advanced Engineering Website: (ISSN , Volume 2, Issue 4, April 2012)

A Novel Image Compression Technique using Simple Arithmetic Addition

No Reference Medical Image Quality Measurement Based on Spread Spectrum and Discrete Wavelet Transform using ROI Processing

A Comparative Study between Two Hybrid Medical Image Compression Methods

Image Gap Interpolation for Color Images Using Discrete Cosine Transform

CHAPTER 4 REVERSIBLE IMAGE WATERMARKING USING BIT PLANE CODING AND LIFTING WAVELET TRANSFORM

A Study of Image Compression Based Transmission Algorithm Using SPIHT for Low Bit Rate Application

Enhancing the Image Compression Rate Using Steganography

SIGNAL COMPRESSION. 9. Lossy image compression: SPIHT and S+P

Video Quality Analysis for H.264 Based on Human Visual System

A Image Comparative Study using DCT, Fast Fourier, Wavelet Transforms and Huffman Algorithm

Blind Measurement of Blocking Artifact in Images

IMAGE COMPRESSION USING HYBRID QUANTIZATION METHOD IN JPEG

CS 335 Graphics and Multimedia. Image Compression

DEEP LEARNING OF COMPRESSED SENSING OPERATORS WITH STRUCTURAL SIMILARITY (SSIM) LOSS

Efficient Color Image Quality Assessment Using Gradient Magnitude Similarity Deviation

BLIND QUALITY ASSESSMENT OF JPEG2000 COMPRESSED IMAGES USING NATURAL SCENE STATISTICS. Hamid R. Sheikh, Alan C. Bovik and Lawrence Cormack

A LOW-COMPLEXITY AND LOSSLESS REFERENCE FRAME ENCODER ALGORITHM FOR VIDEO CODING

EXPLORING ON STEGANOGRAPHY FOR LOW BIT RATE WAVELET BASED CODER IN IMAGE RETRIEVAL SYSTEM

Optimizing the Deblocking Algorithm for. H.264 Decoder Implementation

IMAGE COMPRESSION. Image Compression. Why? Reducing transportation times Reducing file size. A two way event - compression and decompression

Compression of Stereo Images using a Huffman-Zip Scheme

DCT Based, Lossy Still Image Compression

Fingerprint Image Compression

Lecture 5: Compression I. This Week s Schedule

PROBABILISTIC MEASURE OF COLOUR IMAGE PROCESSING FIDELITY

Center for Image Processing Research. Motion Differential SPIHT for Image Sequence and Video Coding

A combined fractal and wavelet image compression approach

WAVELET VISIBLE DIFFERENCE MEASUREMENT BASED ON HUMAN VISUAL SYSTEM CRITERIA FOR IMAGE QUALITY ASSESSMENT

REGION-BASED SPIHT CODING AND MULTIRESOLUTION DECODING OF IMAGE SEQUENCES

DENOISING OF COMPUTER TOMOGRAPHY IMAGES USING CURVELET TRANSFORM

Dicom Color Medical Image Compression using 3D-SPIHT for Pacs Application

Denoising of Fingerprint Images

REVIEW ON IMAGE COMPRESSION TECHNIQUES AND ADVANTAGES OF IMAGE COMPRESSION

DIGITAL IMAGE PROCESSING WRITTEN REPORT ADAPTIVE IMAGE COMPRESSION TECHNIQUES FOR WIRELESS MULTIMEDIA APPLICATIONS

CSEP 521 Applied Algorithms Spring Lossy Image Compression

Image Compression Algorithm and JPEG Standard

IMAGE PROCESSING USING DISCRETE WAVELET TRANSFORM

Context based optimal shape coding

International Journal of Computer Engineering and Applications, Volume XII, Issue I, Jan. 18, ISSN

JPEG 2000 vs. JPEG in MPEG Encoding

ISSN (ONLINE): , VOLUME-3, ISSUE-1,

DIGITAL IMAGE WATERMARKING BASED ON A RELATION BETWEEN SPATIAL AND FREQUENCY DOMAINS

Efficient Image Compression of Medical Images Using the Wavelet Transform and Fuzzy c-means Clustering on Regions of Interest.

Topic 5 Image Compression

FOR compressed video, due to motion prediction and

Differential Compression and Optimal Caching Methods for Content-Based Image Search Systems

CS 260: Seminar in Computer Science: Multimedia Networking

Video Compression An Introduction

Key words: B- Spline filters, filter banks, sub band coding, Pre processing, Image Averaging IJSER

INTERNATIONAL JOURNAL OF PURE AND APPLIED RESEARCH IN ENGINEERING AND TECHNOLOGY

A Novel Approach for Deblocking JPEG Images

Network-based model for video packet importance considering both compression artifacts and packet losses

Medical Image Sequence Compression Using Motion Compensation and Set Partitioning In Hierarchical Trees

Intra-Mode Indexed Nonuniform Quantization Parameter Matrices in AVC/H.264

Visually Improved Image Compression by using Embedded Zero-tree Wavelet Coding

Professor Laurence S. Dooley. School of Computing and Communications Milton Keynes, UK

MULTIMEDIA COMMUNICATION

VLSI Implementation of Daubechies Wavelet Filter for Image Compression

Reversible Blind Watermarking for Medical Images Based on Wavelet Histogram Shifting

Image Quality Assessment: From Error Visibility to Structural Similarity. Zhou Wang

Lossless and Lossy Minimal Redundancy Pyramidal Decomposition for Scalable Image Compression Technique

Image Compression Using BPD with De Based Multi- Level Thresholding

Reversible Wavelets for Embedded Image Compression. Sri Rama Prasanna Pavani Electrical and Computer Engineering, CU Boulder

Part 1 of 4. MARCH

CHAPTER 3 SHOT DETECTION AND KEY FRAME EXTRACTION

Modified SPIHT Image Coder For Wireless Communication

VIDEO DENOISING BASED ON ADAPTIVE TEMPORAL AVERAGING

2284 IEEE TRANSACTIONS ON IMAGE PROCESSING, VOL. 16, NO. 9, SEPTEMBER VSNR: A Wavelet-Based Visual Signal-to-Noise Ratio for Natural Images

Digital Image Representation Image Compression

A Video Watermarking Algorithm Based on the Human Visual System Properties

A New Modified Fast Fractal Image Compression Algorithm in DCT Domain

2014 Summer School on MPEG/VCEG Video. Video Coding Concept

Medical Image Compression Using Wavelets

MIXDES Methods of 3D Images Quality Assesment

The Standardization process

University of Mustansiriyah, Baghdad, Iraq

Statistical Image Compression using Fast Fourier Coefficients

Transcription:

JOURNAL OF MEDICAL INFORMATICS & TECHNOLOGIES Vol. 24/2015, ISSN 1642-6037 Bilateral symmetry, Human visual system, MRI and CT images, Just noticeable distortion, Perceptually lossless compression Chandrika B.K. 1, Aparna P. 2, Sumam DAVID S 2 ANALYSIS AND COMPARISON OF SYMMETRY BASED LOSSLESS AND PERCEPTUALLY LOSSLESS ALGORITHMS FOR VOLUMETRIC COMPRESSION OF MEDICAL IMAGES Modern medical imaging techniques produce huge volume of data from stack of images generated in a single examination. To compress them several volumetric compression techniques have been proposed. Performance of these compression schemes can be improved further by considering the anatomical symmetry present in medical images and incorporating the characteristics of human visual system. In this paper a volumetric medical image compression algorithm is presented in which perceptual model is integrated with a symmetry based lossless scheme. Symmetry based lossless and perceptually lossless algorithms were evaluated on a set of three dimensional medical images. Experimental results show that symmetry based perceptually lossless coder gives an average of 8.47% improvement in bit per pixel without any perceivable degradation in visual quality against the lossless scheme. 1. INTRODUCTION Volumetric medical image compression techniques have an important role in telemedicine and Picture Archiving and Communication Systems (PACS) as it minimizes the data storage requirement and the data transmission time leading to, saving in transmission and PACS implementation cost. Number of three dimensional (3D) image compression techniques for volumetric medical images have been proposed so far, for exploiting the redundancies among pixel values of the image in the 3D space. Most of the algorithms use 3D decorrelating transformations or prediction methods to remove slice redundancy in 3D medical images. Part-2 of Joint Photographic Experts Group (JPEG)-2000 [13] apply 1D reversible 5/3 wavelet transform across image slices, followed by JPEG 2000 on the resulting transformed slices to compress 3D data. Since most of the medical image slices are relatively symmetrical, V. Sanchez et. al. [11] implemented a compression algorithm which exploits the anatomical symmetries present in structural medical images. Same authors modified this algorithm [10] by adding a inter-slice Differential Pulse Code Modulation (DPCM) prediction method to exploit the 1 Department of Electrical and Electronics Engineering, Manipal Institute of Technology, Manipal University, 576104, India. e-mail: chandrika.bk@manipal.edu 2 Department of Electronics and Communication Engineering, National Institute of Technology Karnataka, Surathkal, Mangalore 575025, India

correlation between slices. They used 2D integer wavelet transform to decorrelate the data, an intraband prediction method to reduce the energy of the sub-bands exploiting inherent symmetry characteristics of medical image data and an embedded block coder to achieve high lossless compression gain and resolution scalability. S. Amraee et. al. [2] eliminates both intra-slice and inter-slice correlations with ing routines considering symmetrical characteristics of these images. The Context based Adaptive Lossless Image Codec (CALIC) use a large number of modeling contexts with non-linear predictor to make the codec adaptive for the varying texture patterns and local gradients in the image through an error feedback mechanism [16]. Embedded coding of Zero-trees of Wavelet coefficients (EZW) propose an efficient way of arranging the bits of the wavelet coefficients for progressive transmission and is a desirable property of image compression applications [3]. Its performance is improved in 3D Context Based EZW (CB EZW) by using context based adaptive arithmetic coding to encode image volumes by exploiting redundancies between image symbols [3]. Existing classical medical image data compression approaches achieve lossless compression ratio ranging from 2:1 to 4:1. Even though these methods provide perfect reconstruction of image, they are not efficient in terms of achieved compression ratio. Lossy compression methods are another class of solutions available for the compression of 3D medical images [9], [6] providing lower bit rate than that of lossless coders at the cost of degradation in image quality. Quality of the reconstructed image is very critical as it may affect the diagnosis. An alternative solution to both the compression schemes is Perceptually Lossless Coder (PLC), which discards visually irrelevant information along with other static redundancies present in 3D image space to improve the compression ratio at the same time maintaining the perceptual quality of reconstructed image. David Wu et al. used this approach to compress Magnetic Resonance Imaging (MRI), Computed Tomography (CT) and computed radiography medical image data sets [15]. They developed a novel algorithm for visual pruning (VP) function which is built on the JPEG 2000 coding framework. The VP function is combined with an advanced model of the Human Visual System (HVS) to identify and to remove visually insignificant/irrelevant information. Also this algorithm offers the benefits of simplicity and modularity. MRI, CT and ultrasound are commonly used volumetric medical image acquisition systems as they support in detecting diseases or abnormalities in the body even though they generate huge data volume. Basically human structural anatomy has approximate bilateral symmetry. This salient feature is reflected in axial and coronal view of MRI and CT images. Symmetry present in region of interest of MRI/CT image data and human visual perception feature can further improve the performance of algorithm. In this paper we have proposed symmetry based perceptually lossless compression technique with lossless methods for 3D MRI and CT medical images and compared with lossless schemes. Perceptually lossless coder uses inter-slice ing to remove inter-slice redundancies, symmetry based intra-slice ing to explore intra-slice correlations and HVS dependent Just Noticeable Distortion (JND) model to eliminate visually insignificant information. Experimental evaluations show that symmetry based perceptually lossless coder gives better efficiency compared to lossless compression for the same set of volumetric medical images. This paper is organized as follows: A brief discussion on lossless image compression, perceptually lossless image compression, symmetry based lossless image compression and symmetry based perceptually lossless image compression methods are given in Section 2. Experimental results are evaluated for the mentioned different methods in Section 3 and conclusions are given in Section 4. 148

2. VOLUMETRIC MEDICAL IMAGE COMPRESSION In this Section symmetry based PLC is developed from the basic lossless image compression scheme for 3D medical images by incorporating symmetry and perceptual qualities to improve the performance. 2.1. LOSSLESS IMAGE COMPRESSION This method attempts to remove the inter-slice redundancy present in the MRI and CT images by means of inter-slice ing algorithm followed by arithmetic coding technique as shown in Fig. 1. Inter-slice ing algorithm is applied on non-overlapping block of size 8 8 with a search window of size 16 16 in the reference frame. Sum of absolute difference is selected as the criterion for the best match. Adaptive arithmetic coding is applied on residuals of ing routine. Original 3D medical images Inter-slice Block match Arithmetic Coding Compressed slice Fig. 1. Block diagram of lossless image compression. 2.2. PERCEPTUALLY LOSSLESS IMAGE COMPRESSION l Original 3D medical images Quantizer Inter-slice Arithmetic coding Compressed slice JND profile Fig. 2. Block diagram of perceptually lossless image compression. Eliminating visually irrelevant information from the image data along with numerical redundancies not only improves compression ratio but also maintains the perceivable visual quality of the image. In order to achieve this, a model of HVS is added to encode the image at the feasible minimum bit rate such that it is indistinguishable from original image. So a HVS based spatial domain JND model which explores both edge and non edge regions along with luminance and texture masking is used to assess the perceptual redundancy [17] at each location of the image. Block diagram of perceptually lossless image compression is shown in Fig. 2. The visibility threshold for grey scale images depends on many factors. Here the JND threshold value is dependent on average background luminance, spatial luminance gradient and texture masking. It is established that human visual perception is sensitive to luminance contrast rather than the absolute luminance value [17]. Also the distortion in very dark regions tend to be less seen than that present in regions of better luminance. So high perceptibility threshold are assigned to either very bright or dark areas and low values in regions of medium grey values. The spatial luminance gradient indicates that the increase in the spatial heterogeneity in the background luminance reduces the visibility of stimuli. 149

Edge accommodative texture masking in spatial domain, is also added to meet the HVS characteristics better. An increase in the texture heterogeneity in the background will accommodate more reduction in the visibility of distortion. Accordingly textured area can mask more deformity than smooth regions. Also error present in edge regions is more prominent compared to non-edge areas due to the fact that edge texture drags more attention in a classic HVS. This model explores both edge and non-edge regions along with luminance masking and texture masking. Perceptually redundant information is eliminated from the image through JND dependent quantizer, restricting all the quantization errors below the distortion threshold value to maintain the visual quality of reconstructed image. 2.3. SYMMETRY BASED IMAGE COMPRESSION Human body has bilateral symmetry and this inherent feature is retained in most of the medical image slices. Symmetry based image compression method takes advantage of this bilateral symmetry in the medical images to improve the compression further. Symmetry detection determines the predominant axis of symmetry [8]. Block diagram of symmetry based lossless image compression and perceptually lossless image compression are shown in Fig. 3 and Fig. 4 respectively. Intra-slice ing is carried out on residual image after interslice ing by splitting it along the axis of symmetry. Intra-slice ing algorithm is similar to inter-slice ing algorithm. Symmetry detector Original 3D medical images Inter-slice Intra-slice Arithmetic coding Compressed slice Fig. 3. Block diagram of lossless image compression with symmetry. Symmetry detector Original3D medical images Quantizer JND profile Inter-slice Intra-slice Arithmetic coding Compressed slice Fig. 4. Block diagram of perceptually lossless image compression with symmetry. 3. PERFORMANCE ANALYSIS Medical image compression algorithms were evaluated on an 8 bit data set of volumetric symmetric MRI and CT images. Details of these image data sets are summarized in Table 1. 150

Volume 1 to 5 are from Mallinckrodt Institute of Radiology, Image Processing Lab [3] and Volume 6 is from BrainWeb: simulated brain database [4]. Table 1. Details of the volumetric medical images used in the assessment. Volume Image Resolution Slices Dynamic range number (W H ) (bpp) (in pixel) 1 CT Skull 256 256 192 8 2 CT Carotid 256 256 64 8 3 MRI Liver t1 256 256 48 8 4 MRI Liver t2 256 256 48 8 5 MRI Pedchest 256 256 64 8 6 MRI Brain 216 176 35 8 Simulation is carried out for all the discussed compression schemes. We implemented the proposed method in Matlab R 2015a 8.5.0 on an Intel R Core TM i7 Processor. Table 2 lists the average bit rate obtained by all compression methods for the test data sets. Lossless compression method of Fig. 1 removes only the redundancy between slices of volumetric medical data since ing algorithm is applied between successive image slices. The achieved lower bit rate in case of symmetry based lossless compression compared to lossless technique is due to removal of even redundancy present within the image slice using intra-slice ing routine for the symmetric image data sets as symmetry detection and intra-slice ing are added to lossless compression algorithm. Table 2. Bit per pixel (bpp) of volumetric image compression algorithms. Volume number Lossless Lossless PLC PLC without symmetry with symmetry without symmetry with symmetry 1 1.783 1.766 1.728 1.652 2 1.683 1.654 1.601 1.508 3 2.383 2.353 2.310 2.282 4 1.795 1.794 1.792 1.791 5 1.645 1.592 1.386 1.336 6 5.573 5.383 4.599 4.495 Even though symmetry property of medical images is not considered in perceptually lossless method, compression efficiency is better than lossless methods due to improved quantization of pixel values. Degradation in the perceivable visual quality is avoided by using a JND dependent quantizer, instead of uniform quantizer. JND model decides the amount of distortion that can be introduced at each pixel position of each image slice. It is due to the fact that human visual perception is less sensitive to distortion in very dark regions than that present in regions of better luminance and also textured area in an image can mask more deformity than smooth regions. Symmetry based perceptually lossless algorithm gives the best performance among all the four techniques since it considers symmetry based redundancy, redundancy between slices and perceptual redundancy. Results obtained are compared among different cases as follows: Case-1: Lossless compression without and with symmetry:- Bit rate is improved by 1.76% on an average in case of lossless compression with symmetry compared to lossless compression without symmetry. 151

Case-2: Perceptually lossless without and with symmetry:- Obtained percentage improvement in bit per pixel is 2.88% on an average in case of perceptually lossless compression with symmetry compared to perceptually lossless compression without symmetry. Fig. 5. Percentage improvement in bpp among different compression methods. Case-3: Lossless and perceptually lossless without symmetry:- An average 7.37% of improvement in bit rate is observed in case of perceptually lossless compression without symmetry compared to lossless compression without symmetry. Case-4: Lossless and perceptually lossless with symmetry:- Maximum improvement in bit rate is obtained as symmetry based perceptually lossless compression method exploits static, symmetry and perceptual redundancies. The bit rate is improved by 8.47% on an average in case of perceptually lossless compression with symmetry compared to lossless compression with symmetry. Percentage improvement in bit rate for test image data sets with all the cases is shown in Fig. 5. The efficiency of the PLC has been examined by comparing bit rate with other 3D lossless compression techniques available in the literature- namely CALIC [16], 3D JPEG [1], 3D EZW [3] and 3D CB EZW [3]. Table 3 compares bit rates of the 5 compression techniques. Table 3. Comparison of bit rates (bpp) of PLC with symmetry with other methods. Volume CALIC 3D EZW 3D CB EZW 3D JPEG PLC Number [16] [3] [3] [1] with symmetry 1 2.725 2.357 2.200 3.112 1.652 2 1.654 1.601 1.527 1.965 1.508 3 3.047 2.545 2.398 3.125 2.282 4 2.243 1.944 1.822 2.622 1.791 5 2.810 2.176 2.022 2.768 1.336 To assess the quality of reconstructed image Peak Signal to Noise Ratio (PSNR) and Relative Error (RE) are generally used, but they do not correlate closely with subjective quality sensed by HVS. HVS based performance metrics Visual Signal to Noise Ratio (VSNR) [5], Visual Information Fidelity (VIF) [12] and Structural Similarity index (SSIM) [14] are also used to 152

measure the quality. It has been proved through Receiver Operating Characteristic analysis that SSIM provides a closer match to subjective assessments [7]. Table 4 gives the evaluation metrics for the reconstruction quality metrics such as PSNR, VSNR, VIF, SSIM and RE. There is no perceivable degradation in the images reconstructed using the proposed coder (Fig. 6). Table 4. Quality metrics of reconstructed image in case of PLC with symmetry. Volume number PSNR (db) VSNR (db) VIF SSIM RE 1 51.42 47.94 0.9565 1 0.619 2 53.46 50.89 0.9710 0.999 0.511 3 42.67 46.69 0.8937 0.994 3.244 4 51.20 47.04 0.9597 1 0.703 5 43.32 54.28 0.8337 0.991 11.716 6 45.75 0.9468 0.998 1.429 (a) (b) (c) (d) (e) (f) (g) (h) Fig. 6. Visual clip of original and reconstructed images. (a) CT Skull original: Slice number 50 (b) CT Skull reconstructed (PSNR=51.4 db) (c) CT Carotid original: Slice number 30 (d) CT Carotid reconstructed (PSNR=53.5 db) (e) MR Liver t2 original: Slice number 30 (f) MR Liver t2 reconstructed (PSNR=51.3 db) (g) MR Brain original: Slice number 20 (h) MR Brain reconstructed (PSNR=45.7 db). 4. CONCLUSION Lossless compression techniques provide perfect reconstruction, but however fail to achieve good compression. In contrast, lossy compression techniques achieve good compression, but are unacceptable for medical images due to poor quality. Hence, this paper proposed a perceptually lossless coder for medical images, that promises good compression like lossy coder without losing any medically significant data. This work exploits symmetry property in the symmetric images thus neglecting spatially redundant information. Perceptually lossless coder considers a JND model based on HVS that eliminates visually insignificant information. The proposed method has been tested on standard datasets and its performance has been compared with lossless, symmetry based lossless and perceptually lossless schemes. This 153

explains the contribution of each technique to the proposed compression method. Observing the results, it can be concluded that combining them all together gives the best compression. Developed compression methods use pixel based visual model. It does not decorrelate image into different frequency levels to remove more redundancies like wavelet based approach. Embedding wavelet based visual model in the compression algorithm may offer significant improvement in compression performance. ACKNOWLEDGEMENT The authors would like to thank Prof Bilgin A., Department of Electrical and Computer Engineering, University of Arizona, Tucson, USA for providing us the medical image data sets. BIBLIOGRAPHY [1] AIT-AOUDIA S., BENHAMIDA F. Z., YOUSFI M. A. Lossless compression of volumetric medical data. Computer and Information Sciences, 2006. Springer, pp. 563 571. [2] AMRAEE S., KARIMI N., SAMAVI S., SHIRANI S. Compression of 3D MRI images based on symmetry in predictionerror field. IEEE International Conference on Multimedia and Expo, 2011. pp. 1 6. [3] BILGIN A., ZWEIG G., MARCELLIN M. W. Efficient lossless coding of medical image volumes using reversible integer wavelet transforms. Proceedings of Data Compression Conference, 1998. pp. 428 437. [4] BRAINWEB. Simulated brain database. 2014. [5] CHANDLER D. M., HEMAMI S. S. VSNR: A wavelet-based visual signal-to-noise ratio for natural images. IEEE Transactions on Image Processing, 2007, Vol. 16. IEEE, pp. 2284 2298. [6] GAUDEAU Y., MOUREAUX J.-M. Lossy compression of volumetric medical images with 3D dead-zone lattice vector quantization. Annals of telecommunications, 2009, Vol. 64. Springer, pp. 359 367. [7] KOWALIK-URBANIAK I., BRUNET D., WANG J., KOFF D., SMOLARSKI-KOFF N., VRSCAY E. R., WALLACE B., WANG Z. The quest for diagnostically lossless medical image compression: a comparative study of objective quality metrics for compressed medical images. SPIE Medical Imaging, 2014, Vol. 9037. pp. 1 17. [8] LOY G., EKLUNDH J. O. Detecting symmetry and symmetric constellations of features. Computer Vision, 2006. Springer, pp. 508 521. [9] RAMASWAMY A., MIKHAEL W. A mixed transform approach for efficient compression of medical images. IEEE Transactions on Medical Imaging, 1996, Vol. 15. IEEE, pp. 343 352. [10] SANCHEZ V., ABUGHARBIEH R., NASIOPOULOS P. 3D scalable lossless compression of medical images based on global and local symmetries. 16th IEEE International Conference on Image Processing, 2009. pp. 2525 2528. [11] SANCHEZ V., ABUGHARBIEH R., NASIOPOULOS P. Symmetry-based scalable lossless compression of 3D medical image data. IEEE Transactions on Medical Imaging, 2009, Vol. 28. IEEE, pp. 1062 1072. [12] SHEIKH H. R., BOVIK A. C. Image information and visual quality. IEEE Transactions on Image Processing, 2006, Vol. 15. IEEE, pp. 430 444. [13] TZANNES A. Compression of 3-dimensional medical image data using part 2 of JPEG 2000. Aware. Inc, Nov, 2003. [14] WANG Z., BOVIK A. C., SHEIKH H. R., SIMONCELLI E. P. Image quality assessment: from error visibility to structural similarity. IEEE Transactions on Image Processing, 2004, Vol. 13. IEEE, pp. 600 612. [15] WU D., TAN D. M., BAIRD M., DECAMPO J., WHITE C., WU H. R. Perceptually lossless medical image coding. IEEE Transactions on Medical Imaging, 2006, Vol. 25. IEEE, pp. 335 344. [16] WU X., MEMON N. CALIC-a context based adaptive lossless image codec. IEEE International Conference on Acoustics, Speech, and Signal Processing, 1996, Vol. 4. pp. 1890 1893. [17] YANG X., LING W., LU Z., ONG E. P., YAO S. Just noticeable distortion model and its applications in video coding. Signal Processing: Image Communication, 2005, Vol. 20. Elsevier, pp. 662 680. 154