SCN 848 Release Notes

Similar documents
MassLynx TM 4.1 SCN 916 Release Notes

MassLynx 4.2 SCN 989 Release Notes

Agilent 7890 GC Instrument Control Software Version 2.5

MassLynx 4.1 SCN 804. Release Notes. SQ Detector 2

Agilent 7890 GC Instrument Control Software Version 2.6

Waters Empower Software A1100 System Configuration Instructions for Ethernet Control

Waters 2707 Autosampler ICS v1.20 Installer

Agilent Instrument Control Framework (ICF) Update A Driver Update 1 (DU1) Hot Fix 2 (HF2)

For additional information, see these documents on the Breeze 2 software DVD:

Agilent GC Drivers A

A. About this Manual

The minimum version of Microsoft's Internet Explorer is version If you need to upgrade, install version 6.0, service pack 1.

Samples Preparing the GC to run samples Running samples - Manual Injection Running samples - GC ALS or Valve Injection

Procedure to set up an HPIB 82350B card on an M57. M58 or C20x PC. Table 1: Parts required. Part Number Description Qty

Waters Headspace Control Option, Version 3.0

Agilent 7890 GC Instrument Control Software Version 2.01

Agilent 68xx Agilent 68xx

Data Acquisition with 3800 GC Control

Waters ACQUITY QDa Instrument Component Software version 1.54

Agilent ICF Support v3.0

Agilent 7890GC. Firmware Bulletin. Revision B and A External use only

Agilent OpenLAB CDS Waters Alliance HPLC Instrument Control Add-On. Installation, Upgrade and Migration Guide

Waters Driver Pack 2016 Release 1

Agilent Instrument Control Framework for Agilent LC/CE and GC instruments in Non-Agilent Chromatography Data Systems A.02.

Customer Information. Service Engineer s Responsibilities. Additional Instruction Notes. System Information. Agilent Technologies

Agilent ChemStation for GC Systems

Agilent 7820A Gas Chromatograph

Agilent OpenLAB CDS. Version 2.2. Release Notes. OpenLAB CDS Release Notes 1

The instrument drivers and firmware in Driver Pack 4 support these ACQUITY UPLC systems: ACQUITY UPLC Systems with 2D Technology

Windows 7 Professional 64 bit Installation and Configuration for MassLynx or Empower Controlled Ethernet Instrument Communication

Agilent OpenLAB Chromatography Data System

MetQuest 1.4 Installation Instructions

Empower 3 Installation, Configuration, and Upgrade Guide /Revision A Copyright Waters Corporation All rights reserved

M8240BA Shimadzu LC Control Driver 1.51 for OpenLAB CDS

Agilent MassHunter Easy Access Software

Network Setup 2.0

Waters Fraction Collector III with Empower Instrument Control Software Version 1.00

Agilent OpenLAB CDS. ChemStation Edition Instrument Configuration. Guide. Agilent Technologies

Nortel Media Application Server 5.1. Installation NN

NEC PowerMate ES SlimLine Series Release Notes. Contents

CTC Sampler Implementation in the GC/MSD ChemStation. Technical Overview. Introduction

HITACHI LACHROM ELITE

Bridge Cable User s Guide

Installing and Using VeritiLink Software Quick Reference Card

Breeze 2 Installation and Configuration Guide

Installation Instructions for JMP Genomics 4.1 for SAS 9.2

Agilent MassHunter Workstation Software 7200 Accurate-Mass Quadrupole Time of Flight GC/MS

Data Acquisition with 3400/3600 GC Control

Upgrade Notes. Star Chromatography Workstation Version What is New in Version What was New in Version 6.30

NEC PowerMate CT Release Notes. Contents

6820 GC (G1176A & G1180A) RS-232/TCP/IP

ChromQuest 4.2 Chromatography Data System

OPERATION MANUAL. MV-410HS Layout Editor. Version higher. Command

ACQUITY UPLC Systems June 2011 Driver Pack and Firmware Updates

Release Notes. Analyst TF Software

Agilent 7890 Series Gas Chromatograph

PAL Sample Control. Edition Date Version

WinMarkpro v6 for the FH Marking Head Quick Start Guide

Novell ZENworks Asset Management 7

Waters Driver Pack 2018 Release 1

Jupiter / Saturn / AccuSwitch Release 7.3.1

LabChip EZ Reader V3.0 SP2 Software Release Notes

User Manual. Unpacking and Setup

Agilent OpenLAB Chromatography Data System (CDS) ChemStation Edition

EZChrom Elite Supported Modules and Firmware Updated 8/12/2009

MachineShop Supplemental Installation

Networking the printer

DCP585CW Windows Network Connection Repair Instructions

OPERATION MANUAL. MV-410HS Web Browser. Version Rev.2

Display Manager Version 1.0

Windows Vista Manual Update Service Pack 2

Longshine Technologie Europe GmbH LCS-MFP101-2 Multifunction Printserver

DI-704P Ethernet Broadband Router. Ethernet (Straight Through) Cable. 5V DC Power Adapter

Varian Modular HPLC System Galaxie Driver Installation and Configuration Instructions

Agilent 7890B Gas Chromatograph

Software Manual Net Configuration Tool Rev. 1.01

Release Notes for Agilent Drivers for Thermo Scientific Chromeleon 7 (Rev. 1.1)

OUTDOOR IR NETWORK CAMERA Series

EasyMP Network Updater Operation Guide

Installation of Hot Disk v 7.3 and later on a PC with Windows 7, 8 or 10

AW-HE40 / HE65 Firmware Update Procedure

TABLE OF CONTENTS COPYRIGHT INTRODUCTION...3 PRODUCT OVERVIEW...3 COMPONENTS AND FEATURES...3 HARDWARE INSTALLATION

EasyMP Network Updater Operation Guide

Installation Procedure Windows 95/98/ME with Internet Explorer 5.x & 6.0

Cover. MATWorX Installation Guide NWA ISSUE 2.1

Upgrading the Cisco D9887B HDTV Modular Receiver Technical Reference

DSL-G624T. Wireless ADSL Router. If any of the above items is missing, please contact your reseller. This product can be set up using any

Agilent G1701DA MSD Productivity ChemStation Software

Lab IP Addresses and Network Communication

Soprane II Documentation

Agilent 1290 Infinity II Evaporating Light Scattering Detector (ELSD) in Empower Environment

Spectrometer Visible Light Spectrometer V4.4

Software Release Notice TimeScan For Windows 2000/XP/Vista Release 8.7

User's Manual V 32.0

8100 Mobile Device System. Radio Access: Call Reliability Product Update

P964 APR 964 Cable Router with 11g AP Quick Installation Guide VER. 1.0

Parallels Desktop 4.0 Switch to Mac Edition. Migrate your PC Tutorial.

Print Server. User s Manual. Rev. 01 (April, 2004) Made In Taiwan

Data Acquisition with CP-2002/2003 Micro-GC Control

Agilent G2070BA GC ChemStation

Transcription:

R E L E A S E N O T E S SCN 848 Release Notes 43198 Rev 1 Copyright Waters Corporation 2011. All rights reserved. 43198 Rev 1. Waters is a registered trademark, Waters the Science of What s Possible and MassLynx are trademark of Waters Corporation All other trademarks are the sole property of their respective owners Copyright 2011 Waters Corporation

Table of Contents MassLynx 4.1 SCN 848... 3 Introduction... 3 Applies to... 3 Fault Fixes... 3 Installation... 3 Notes... 4 Files Updated... 4 Concessions in SCN 848... Error! Bookmark not defined. Agilent 7890 Systems... 5 Supported Computers, Operating systems, Hotfixes and Anti-Virus software... Error! Bookmark not defined. Instrument Software... Error! Bookmark not defined. Applications Software... Error! Bookmark not defined. Antivirus... Error! Bookmark not defined. Page 2 of 8 43198 Rev 1.

MassLynx 4.1 SCN 848 Introduction Software Change Note #848 fixes an issue when using Masslynx with CTC Pal system on MassLynx SCN 689 with SCN730 small update. This SCN replaces SCN 730. Applies to MassLynx 4.1 SCN 848 applies to the following hardware configurations: MS GCT-P CTC Combi PAL GC Agilent 7890 GC Version 2.0.0.18 Operating Systems Microsoft Windows XP Professional SP3 Security Masslynx Security module is not supported in this SCN. Fault Fixes Sample list pausing when running CTC-Combi-PAL (GCT-P + 7890 GC + CTC Combi-PAL) with HS_inj or SPME methods has been resolved. Installation MassLynx 4.1 SCN 848 is a small update based on SCN 689. 1. Close MassLynx and any other software applications. 2. If any instrument drivers - such as Waters Pump Control, ACQUITY drivers, Waters 2777 / CTC drivers or Agilent LC or 7890 GC drivers - have been installed they must be removed using Windows Add/Remove programs before installing SCN 848. 3. If MassLynx (including V4.1 SCN 689) is installed, it must be removed using Windows Add/Remove programs and the PC rebooted after the removal is complete. 4. If the "C:\Program Files\Micromass Utilities\ICOP" folder still exists after uninstalling existing MassLynx versions it must be manually deleted prior to installation of SCN848. Install MassLynx V4.1 SCN 848 following the installation instructions. Page 3 of 8 43198 Rev 1.

1. Insert the MassLynx SCN 689 DVD into the DVD ROM drive 2. Select Start >Run from the windows start menu and type: <DVD Drive>:\setup <return> Where, <DVD DRIVE> is the drive letter of the DVDROM. 3. Follow the instruction of the program. 4. Click Finish to complete the installation of the SCN 689 5. Reboot the instrument embedded PC. 6. Insert the Masslynx SCN 848 DVD into the DVD-ROM drive 7. Select Start >Run from the windows start menu and type: <DVD Drive>:\setup <return> Where, <DVD DRIVE> is the drive letter of the DVDROM. 8. Follow the instruction of the program. 9. Click Finish to complete the installation of the SCN 848 10. Reboot the instrument embedded PC. If an inlet system is being used: 11. Launch MassLynx and open the Inlet Editor. Select Instrument Configuration from the Tools menu. 12. Install any required Waters instrument drivers (ICS) using the Deployment Manager by clicking Setup Instruments. If any drivers are installed it is recommended that the PC is rebooted afterwards before continuing the inlet system configuration. 13. Click Configure to launch the Inlet Configuration Dialog to complete the configuration of the inlet system. Notes Modifying or repairing an installation is not supported. Files Updated SCN 848 updates the following files: C:\Masslynx\InletKernel.exe C:\Masslynx\ScriptHelper.dll C:\Masslynx\WatersGenPlugInCtrl.dll C:\Masslynx\WatersGenPlugInViews.dll C:\windows\system32\Waters2777MgrService.exe C:\Masslynx\Waters2777MgrServiceps.dll C:\Masslynx\Default.pro\acquadb\Default.a7890 Page 4 of 8 43198 Rev 1.

Agilent 7890 Systems Supported Hardware Agilent 7890 GC system PTV, COC, Split/Splitless, Purged Packed Volatile Interface and Multimode inlets. Agilent 7683B Autosampler Agilent 7693A Autosampler GC PAL and Combi PAL Autosampler Agilent 7890GC Dean Switch and 2-way splitter by EPC Agilent 7890 GC detectors supported are: Flame Ionization Detector (FID) Thermal Conductivity Detector (TCD) Micro-Electron Capture Detector (micro-ecd) Other options: PCM control of Dean Switch via GC panel only Gerstel CIS-4 injector pneumatic control only. Installation of 7890 GC Systems 1. Follow the general installation instructions for installing the 7890 driver and configuring the inlet system. 2. Close MassLynx. 3. If using one LAN card and a hub go to step 4. If using two LAN cards instead of a hub, follow the steps below. a. Make a note of the IP address of the A7890 GC instrument connected to the host PC. The IP address of the instrument is available on the A7890 instrument control panel. Use <Options> key and scroll to the Communications section and press <Enter>. The IP address should be in the form of 192.168.000.xxx. b. Launch Control Panel from the Windows Start Menu c. Double click on the Network Connections application listed in Control Panel d. In the Network Settings window right click on the Ethernet device connected to the GC instrument and select the Properties option. The LAN properties dialog pops up. e. Select Internet Protocol (TCP/IP) option on the LAN properties dialog and click on the Properties button. Internet Protocol (TCP/IP) Properties dialog pops up f. Ensure that the IP address and sub-net mask on the Internet Protocol (TCP/IP) Properties dialog are set as defined below: i. Select Use the following IP address. ii. Set the IP Address: 192.168.000.xxx (Doesn't have to be specifically this value, but must not be the same as the IP address of the GC instrument). The IP address of the GC instrument was obtained in step 13(i). iii. Set up Subnet mask: 255.255.255.000 g. Click on Ok button to close Internet Protocol (TCP/IP) Properties dialog. h. Click on the OK button on the LAN Properties window to complete the LAN configuration set up. i. Go to step 4. Page 5 of 8 43198 Rev 1.

4. Configure the Waters DHCP for the A7890 as shown in the steps below. a. Ensure MassLynx is closed. b. Ensure that A7890 GC instrument is connected to host PC. c. Make a note of the GC IP address, MAC address and serial number of the A7890 GC instrument connected to the host PC. These details can be obtained as follows:- i. The IP address and MAC address of the instrument are available on the A7890 instrument control panel. Use <Options> key and scroll to the Communications section and press <Enter>. The IP address should be in the form of 192.168.000.xxx and the MAC address should be in the form of 00-XX-XX-XX- XX-XX. ii. A7890 instrument serial number is seen on the bottom left of the instrument front body panel. (Below the control panel). d. Run C:\Program Files\Waters Instruments (x86)\waters DHCP Server Configuration.exe. Waters DHCP Server configuration window pops up. e. Click on Add button to add a new DHCP entry for A7890 instrument. The Add IP Address dialog pops up. f. Update the Add IP Address dialog with the below details: i. Update the IP Address and MAC Address fields with the corresponding values noted in Step 14(iii). ii. Select the Instrument Type as A7890 from drop down option. iii. Enter the serial number noted in Step 14(iii) into the Serial Number/Unique Name field. g. Click on OK button to complete the Waters DHCP configuration for A7890 GC instrument. 5. Start Masslynx, open the Inlet Editor and reset the GC communication. Notes for Agilent 7890 Systems Any new inlet file must be based either on the default inlet file, or on another inlet file that itself is based on the default inlet file. Otherwise the method may not download successfully. The default inlet file, default.a7890, must not be deleted from the system. If any changes are made to the default.a7890 file then it is recommended that the changes are saved with a different file name. If a new MassLynx project is created, it must be based on the default MassLynx project (or on another MassLynx project that is itself based on the default MassLynx project). If not, any necessary files (e.g. default.a7890, CTC autosampler macros) must be manually copied into the new MassLynx project. The A7890 method editor can be used to edit existing A7890 methods or to create new A7890 methods. The A7890 method editor can be invoked from inlets buttons (Pump, Autosampler or Detector button) available on the left side of the Inlet Method Editor. To print an A7890 method, the A7890 method file must be opened once in the A7890 method editor. Sampler offset must not be activated in dual injection tower mode. Otherwise the autosampler parameters will not download. On the Agilent 7683 and 7693 ALS, the Allow Sampling Offset option available in the Front/Back Injector tab of the A7890 method editor does not work as expected. Even when the sample offset option is disabled in the A7890 method editor, a static value of 10mm is downloaded to the instrument. If the sample offset is not required to be used in routine sample Page 6 of 8 43198 Rev 1.

analysis, then the Allow Sample Offset option should be enabled in the method editor and should be set to value 0.0mm. This will ensure that the offset option is switched off on the instrument. AutoPrep functionality is not supported with MassLynx. To stop the current inlet method, the run must be manually stopped from the GC instrument front panel. However, when using a GC PAL, do not stop the method until after the Running LED has changed to green, otherwise the next sample will go straight to Acquire and the inlet method will not be run. The Running LED is on the inlet method editor. There are two versions of A7890 ICS supported in MassLynx:- A7890 Phase 1 ICS (ICS Rev No: 1.0.1.2) which comes with SCN 714. An upgraded version, A7890 Phase 2 ICS (ICS Rev No: 2.0.0.19), supported as part of this SCN 848. Only one version of the ICS can be used at any one time. The ICS version can only be used with the specific SCN, i.e. Phase 1 ICS with SCN 714; Phase 2 ICS with SCN 848. If the ICS is to be downgraded from the A7890 Phase 2 ICS (ICS Rev No: 2.0.0.19) to A7890 ICS Phase 1 (ICS Rev No: 1.0.1.2) by reinstalling MassLynx SCN 714, then the steps below must be followed to ensure that the proper ICS version is installed. Uninstall MassLynx 4.1 via Windows Add/Remove program. Uninstall A7890 ICS 2.0.0.19 via Windows Add/Remove program Delete the C:\Program Files\Micromass Utilities\ folder. Reboot PC. Install MassLynx 4.1 SCN 714 Install A7890 Phase 1 ICS (ICS Rev No: 1.0.1.2) by running Setup.exe file from C:\Program Files\Micromass Utilities\ICOP\A7890. When the A7890 ICS Phase 2 (ICS Rev Number: 2.0.0.19) is uninstalled as part of the downgrade process, the host registry keys shown below must be manually deleted prior to installation of A7890 Phase 1 ICS. HKEY_LOCAL_MACHINE\SOFTWARE\Waters\Instruments\A7890\ To control a GC PAL or Combi PAL with the 7890 GC, the PAL must be configured with an Out signal called Prep. The sample list may randomly stop with Waiting for Prep Run status when using a CTC PAL. The inlet method is not run, and there is no error message. The sample batch can be restarted by pressing Prep on the GC. The workaround is to increase the length of the Pulse Times for the Prep signal on the PAL to 500 ms. The Pulse Times for CTC PAL can be set on CTC PAL instrument control panel through: Setup/Objects/Out Signals/Prep menu. If an FID, TCD or micro-ecd detector is connected on the A7890 GC instrument and data is to be acquired from the detector, the detector must be configured as A7890 from the Inlet Method editor ->Tools -> Instrument Configuration menu option. When the detector is configured, the Channel 1 or Channel 2 option must be enabled. Also, Front Detector or Back Detector must be selected as the Output channel in the Channel 1 tab of the A7890 method file (or Channel 2 tab if Channel 2 is selected). Attempting to acquire data with a detector configured but the Channel 1 or Channel 2 option disabled in the A7890 method, will result in the sample list pausing at the end of each sample with the error No data was acquired on detector. If an FID, TCD or micro-ecd detector is connected on the A7890 GC instrument but there is no intention to acquire the detector data, de-configure the detector from the Inlet Method editor - >Tools -> Instrument Configuration menu option and ensure the Channel 1 and Channel 2 option is disabled in the A7890 method file. Page 7 of 8 43198 Rev 1.

Alternatively, the Channel 1 or Channel 2 option can be left enabled but a valid source option (such as Oven Temperature or Front Inlet Pressure etc) must be selected in the Channel 1 or Channel 2 tab accordingly. Note that in a new A7890 method file the Channel 1 option is enabled and, on the Channel 1 page, the Source field is configured to Front Detector Output by default. The Channel 1 option will need to be disabled or a valid source option must be selected. If an FID, TCD or micro-ecd detector is not connected on the A7890 GC instrument and there is no intention to acquire the detector data, de-configure the detector from the Inlet Method editor ->Tools -> Instrument Configuration menu option and ensure the Channel 1 and Channel 2 option is disabled in the A7890 method file. If the A7890 GC column is connected to the MS then ensure that the output of the column is set to MSD in the A7890 method. It allows the column to maintain proper backing pressure If the outlet of the A7890 GC column is connected to the MS through an APGC interface, then ensure that the outlet of the column is set to the Other option in the A7890 method file. The A7890 GC instrument supports different hardware configurations as stated in the Supported Hardware Configurations section above. The parameters that are configured in the A7890 method file should match the hardware configurations that are available on the A7890 GC system. Failing to do so will cause an error in the Inlet Method editor. Selecting Reset Communication from the Inlet Method tools menu will reset the error. Page 8 of 8 43198 Rev 1.