Actuators for modulating control AME 13SU, AME 23SU - safety function (spring up)

Similar documents
Actuators for modulating control AME 55, AME 56

Modulating controlled actuators AME 10, AME 20, AME 30 AME 13, AME 23, AME 33 - with DIN EN certified safety function (spring down)

Modulating controlled actuator AME 11

Actuators AMV 655, 658 and 659 can be controlled by electronic controllers with 3-point output.

24V, Motorized Actuators

Actuators for three point control AMV 655 without safety function AMV 658 SU, AMV 658 SD with safety function (spring up/down)

Electrical actuator AME 855

Actuators AME 655, 658 and 659 can be controlled by electronic controllers with modulating or 3-point control output.

AME 658 SU/ SD with safety function Motorized actuators for AB-QM valves

Actuators for modulating & 3-point control

Data Sheet A200 Series Electric Actuators

Electrical Actuators

Products no longer available

Electrical actuators

Electrical Actuators

Electromotoric actuators

Electrical Actuators

AV24-MFT AV24-MFT2 AV24-MFT2-C105. Power consumption In operation For wire sizing N 1700 N Control Control signal Y Operating range

Motorised actuator 0-10V EAC

ASI Systems ML5740A Series

ASI Systems ML5720A Series

NovoCon S Digital/Hybrid - High Accuracy Actuator

Products no longer available

Electromotoric actuators

SRQ24A. Technical data. Safety notes. Rotary actuator for ball valves Torque 16Nm Nominal voltage AC/DC 24V Control: Open-close Running time 9s

Overview of types. Technical data

VA-7700 Series. Electric Valve Actuators. Product Bulletin

Technote. Frese OPTIMA Compact actuators DN10-DN32. Application. Features thermic actuators. Features motoric actuators. Approval.

Electromotoric actuators

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

ML7421A,B Electric Linear Valve Actuators

Power consumption In operation At rest For wire sizing. Torque Inhibiting torque. 150 s / C Sound power level Motor

Technical data sheets

Power consumption In operation At rest For wire sizing. Torque Inhibiting torque. 150 s / C Sound power level Motor

B. AVM321S/AVM322S: 1000N Actuator with analog SUT positioner

See «Overview of types» 90 s / 60 mm 150 s / 100 mm Manuelle Auslösung der Adaption durch Drücken der Taste «Adaption» oder mit dem PC-Tool

9.5 nominal torque 4.5 W 16 VA. Min. 30 nominal voltage Min. 30 Nm. Reversible with switch By mounting. MIN (minimum position)

TXM1.8T. Triac module Used for Thermic and motor-driven actuators (AC 24 V) TX-I/O

Actuator ABNM A5 LOG/LIN for AB-QM, 0-10 V Proportional

Technical data sheet. Technical data

Functional data Factory settings Variable Setting Torque Inhibiting torque

Powermite 599 MT Series SAS Electronic Valve Actuator 24 Vac or 24 Vdc, Proportional Control

Functional data Nominal torque min. 180 in lb [20 NM] Communicative control Cloud: (call for clientapi )

UC102 basic version with display and knob UC102BL version with display, knob and backlight UC102DK version without knob and display

s Spring return C / max C

ECM3000. Control Motor

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency. Draft

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

MVE5xxR. Globe Valves Actuators with Emergency Fail Safe Function DESCRIPTION POWER SUPPLY [N] APPLICATION AND USE OPERATION

Rotary actuator for ball valves KNX / PL-Link

N20010-SER. NON-SPRING RETURN DAMPER ACTUATOR 20 Nm (177 lb-in) FOR ADJUSTABLE MODULATING CONTROL SPECIFICATIONS GENERAL FEATURES PRODUCT DATA

Semi flush-mounted room temperature controllers with LCD

Power consumption In operation At rest For wire sizing

N20010, N NON-SPRING RETURN DAMPER ACTUATOR 20/34 Nm (177/300 lb-in) FOR MODULATING CONTROL SPECIFICATIONS GENERAL FEATURES PRODUCT DATA

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

ILEA_IOM. Installation Instructions for ILEA electric actuators ILEA-Ax ILEA-Bx ILEA-Px ILEA-Qx TABLE OF CONTENTS

Electric Actuators Type 5824 (without fail-safe action) Type 5825 (with fail-safe action)

VA Electric Terminal Unit Actuator. Benefits. Technical Specifications. Double colour LED. Low and line voltage.

Control Motor ECM3000

I ntroduction. RA Fast Running Electric Actuator. Features and Benefits

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

M3P..G/A, M3P..F/A Modulating control valves (PN16) for chilled and hot water systems

AVM 321, 322: Valve actuator

Functional data Communicative control Cloud: (call for clientapi ) Angle of rotation 90

SAX.. ACVATIX Electromotive actuators for valves. with a 20 mm stroke

Electromotoric actuators

Powermite 599 MT Series SSC Electronic Valve Actuator, 24 Vac Floating Control

VLT Line Filter MCC 107 EMC Filter Series VLT Midi Drive FC 280 (K1 K3)

Brief description. Type overview

MVE5xx. Globe Valves Actuators POWER SUPPLY FORCE (N) MODEL DESCRIPTION APPLICATION AND USE OPERATION. long yoke, modulating/floating control

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Cables. U.S. Registered Trademark EN0B-0341GE51 R0402 Copyright 2002 Honeywell Inc. All rights reserved

RTT2 ROOM TEMPERATURE SWITCH. Mounting and operating instructions

Manual Control Unit GFC 32

TA-MC Actuators. Actuators High performance proportional actuators

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Non-communicating room controllers

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

COMMERCIAL. VAM24-90-(A) Series

Functional data Position indication reflective visual indicator (snap on) Communicative control Cloud: (call for clientapi )

Electromotive actuators for combi valves

ACTUATOR SERIES 90 3-POINT ROTARY MOTORIZED VALVES

Ball valve Metal. Sectional view. * see information on working medium on page PED/97/23/EC Category III Module H TA-LUFT

VAV compact controller GDB181.1E/3 GLB181.1E/3

599 Series Zone Valve Actuator SF Series Electronic Valve Actuator, 2-position Control

Actuator Zone 1 Mar 2004

M6410A, M7410F Small Individual Room Controller (IRC) Electric Linear Valve Actuators

Manual Control Unit GFC 16

Power supply module, bus connection module

Semi flush-mounted room temperature controllers with LCD

Power supply. Interface technology in modular housing DIN rail devices, IM series. Features

Preliminary ILEA A/B SERIES IOM. ILEA A/B Series electric actuators ILEA-Axx ILEA-Bxx TABLE OF CONTENTS. ILEA-A/B_IOM_NoRev_ No Rev

Room Temperature Controller

M7410G LINEAR VALVE ACTUATOR WITH LON CAPABILITIES

Electromotoric actuators for stroke valves

RXM39.1. PL-Link IO Block. Desigo TRA. Use with PXC3 series room automation station

Non-communicating room controllers

MVS RAIL ELECTRONIC FAN SPEED CONTROLLER. Mounting and operating instructions

FXVMA Variable Air Volume (VAV) Box Controller

Functional data Communicative control Cloud: (call for clientapi ) Angle of rotation 90

Transcription:

Actuators for modulating control AME 13SU, AME 23SU - safety function (spring up) Description AME 13SU AME 23SU The actuators with safety function are mainly used with VZ valve (AME 13SU) or with VS, VM and VB valves (AME 13SU, AME 23SU). Safety version is activated automatically in case of power failure or if the power supply is switched off by the safety thermostat. The actuator has some special features: The advanced design incorporates load related switch-off to ensure that actuators and valves are not exposed to overload; The advanced design incorporates a diagnostic LED, operational data capture and self stroking feature; Low weight and robust; Sefety function (spring up). Main data: Nominal voltage: - 24 VAC, 50 Hz/60 Hz Control input signal: - 0(4) 20 ma - 0(2) 10 V Force: 300 N (13SU); 450 N (23SU) Stroke: 5,5 mm (13SU); 10 mm (23SU) Speed: 14 s/mm (13SU); 15 s/mm (23SU) Max. medium temperature: 130 C Self stroking Ordering Type AME 13SU AME 23SU Supply voltage (V) 24 Code No. 082H3044 082G3042 Technical data Type AME 13SU AME 23SU Power supply V 24; +10 to 15 %; AC Power consumption VA 9 Frequency Hz 50/60 Control input Y V 0-10 (2-10) ma 0-20 (4-20) Output signal X V 0-10 (2-10) Closing force N 300 450 Max. stroke mm 5,5 10 Speed s/mm 14 15 Max. medium temperature Ambient temperature C 0 55 Storage and transport temp. 40 70 Grade of enclosure IP 54 Weight kg 0,8 1,45 - marking in accordance with standards 130 Low voltage directive (LVD) 2006/95/EC: EN 60730-1, EN 60730-2-14 EMC Directive 2004/108/EC: EN 61000-6-2, EN 61000-6-3 DEN-SMT/SI VD.AB.U4.02 Danfoss 03/2014 1

Installation AME 13 SU AME 23 SU Mechanical The actuator should be mounted with the valve stem in either horizontal position or pointing upwards. The actuator is fixed to the valve body by means of a mounting nut which requires 32 mm screw key. The nut should be tightened with a torque of max. 25 Nm. Electrical Electrical connections can be accessed by removing the cover. Two M16 1,5 cable entries are provided. However, in order to maintain the enclosure IP rating an appropriate cable gland must be used. Disposal The actuator must be dismantled and the elements sorted into various material groups before disposal. 2 VD.AB.U4.02 Danfoss 11/2013 DEN-SMT/SI

DIP switch setting The actuator has a function selection DIP switch under the removable cover. In particular, if SW3 is set to ON, the actuator will perform as 3-point actuator. The switch provides the following functions: SW1: U/I - Input signal type selector: If set to OFF position, voltage input is selected. If set to ON position, current input is selected. SW2: 0/2 - Input signal range selector: If set to OFF position, the input signal is in the range from 2-10 V (voltage input) or from 4-20 ma (current input). If set to ON position, the input signal is in the range from 0-10 V (voltage input) or from 0-20 ma (current input). SW3: D/I - Direct or inverse acting selector: If set to OFF position, the actuator is direct acting (stem lowers as voltage increases). If actuator is set to ON position the actuator is inverse acting (stem raises as voltage increases). SW5: 0-5 V/5-10 V - Input signal range in sequential mode: If set to OFF position, the actuator is working in sequential range 0(2)-5(6) V or 0(4)-10(12) ma. If set to ON position, the actuator is working in sequential range; 5(6)-10 V or 10(12)-20 ma. SW6: Prop./3-pnt - Modulating or 3-point mode selector: If set to OFF position, the actuator is working normally according to control signal. If set to ON position, the actuator is working as 3-point actuator. SW7: LOG/LIN - Not in use. SW8: 100 % k VS/Reduced k VS - Not in use SW9: Reset: Changing this switch position will cause the actuator to go through a self calibration cycle. SW4: /Seq - Normal or sequential mode selector: If set to OFF position, the actuator is working in range 0(2)-10 V or 0(4)-20 ma. If set to ON position, the actuator is working in sequential range; 0(2)-5 (6) V or (0(4)-10 (12) ma) or (5(6)-10 V) or (10(12)-20 ma). DEN-SMT/SI VD.AB.U4.02 Danfoss 11/2013 3

Wiring Wiring length Recommended square of the wiring 0-50 m 0,75 mm 2 > 50 m 1,5 mm 2 24 VAC SP SN Y X 24 Vac...Power supply 0 V...Common 0-10 V...Input signal (2-10 V) 0-20 ma (4-20 ma) 0-10 V...Output signal (2-10 V) Automatic self stroking feature When power is first applied, the actuator will automatically adjust to the length of the valve stroke. Subsequently, the self stroking feature can be re-initialised by changing position of DIP SW9. Diagnostic LED The red diagnostic LED is located on the pcb under the cover. It provides indication of three operational states: Actuator Healthy (Permanently ON), Self Stroking (Flashes once per second), Error (Flashes 3 times per second - seek technical assistance). Commissioning Complete the mechanical and electrical installation and perform the necessary checks and tests: Isolate control medium. (e.g. self stroking in a steam application without suitable mechanical isolation could cause a hazard). Apply the power. Note that the actuator will now perform the self stroking function. Apply the appropriate control signal and check the valve stem direction is correct for the application. Ensure that the actuator drives the valve over its full stroke, by applying the appropriate control signal. This action will set the valve stroke length. The unit is now fully commissioned. Commissioning/testing feature The actuator can be driven to the fully open or closed positions (depending on valve type) by connecting SN to terminals 1 or 3. 4 VD.AB.U4.02 Danfoss 03/2014 DEN-SMT/SI

Manual override AME 13 SU AME 23 SU On spring versions manual override is achieved by disconnecting the power supply, removing the cover and inserting a 6 mm Allen key for AME 13 SU, a 5 mm Allen key for AME 23 SU (not supplied) into the top of the positioning spindle and turning the key against the spring. Observe the direction of rotation symbol. To hold a manual override position, the key must be wedged. If manual override has been used then X and Y signal are not correct until the actuator reaches its end position. If this is not accepted reset the actuator. Safety function The safety function will fully open or close the valve when the power is removed, depending upon the spring action selected. Valve selection will also affect the spring action. The safety function unit is factory fitted to the rear of the actuator. or = SU Valve type VZ VS VM VB If safety version is activated than port A-AB will be CLOSED OPENED OPENED OPENED DEN-SMT/SI VD.AB.U4.02 Danfoss 03/2014 5

Dimensions AME 13 SU AME 23 SU Actuator - valve combinations - which close port A-AB if safety version is activated AME 13 SU + VZ (DN 15-20) - which open port A-AB if safety version is activated) AME 13 SU + AME 13 SU + AME 23 SU + AME 23 SU + VM2 (DN 15-25) VB2 (DN 15-20) VM2 (DN 15-25) VB2 (DN 15-20) VS2 (DN 15-25) VS2 (DN 15-25) 6 VD.AB.U4.02 Danfoss 03/2014 DEN-SMT/SI

DEN-SMT/SI VD.AB.U4.02 Danfoss 03/2014 7

8 VD.AB.U4.02 Produced by Danfoss A/S 03/2014