Copyright December 2017 Nidec Issue: D

Similar documents
- 15G0078B130 - USB MODULE INSTRUCTIONS FOR ASAC-0/ASAC-1/ASAB

1. Introduction. 2. Installation INSTALLATION INSTRUCTIONS: MCD USB MODULE

Copyright: December 2017 Nidec Issue: E

Copyright: December 2017 Nidec Issue: E

User Guide. Modbus Module. For Digistart soft starters. Part Number: Issue: 3.

ETHERNET/IP & PROFINET MODULE

MODBUS RTU MODULE INSTRUCTIONS. for use with WSIQ2/WSE

PROFINET MODULE. Communications module. User Guide. This manual is to be given to the end user en / a. Power. Error. Status.

It is the installer's responsibility to follow all instructions in this manual and to follow correct electrical practice.

ASTAT XB/XBm Remote Operator

It is the installer's responsibility to follow all instructions in this manual and to follow correct electrical practice.

DeviceNet Module. User Manual. 1 Important User Information. 2 Installation

Observe all necessary safety precautions when controlling the soft starter remotely. Alert personnel that machinery may start without warning.

- 15G0078B110 - PROFIBUS MODULE INSTRUCTIONS FOR ASAC-0/ASAC-1/ASAB

Observe all necessary safety precautions when controlling the soft starter remotely. Alert personnel that machinery may start without warning.

MODBUS TCP MODULE INSTRUCTIONS. for use with WSIQ2/WSE

Profinet Module. User Manual. Contents

- 15G0078B120 - DEVICENET MODULE INSTRUCTIONS FOR ASAC-0/ASAC-1/ASAB

Instructions. Modbus RTU Card (WSIQ-COM-MB)

Ethernet/IP Module. User Manual. Contents

Install the DeviceNet Module using the following procedure:

Update for Acceptor Head V4.10. MD-100 Acceptor Head EBA-34

USB485 USB to RS485 Converter Card

MCD 200 MCD 500. Remove the Profibus Module using the following procedure: 1. Remove power from the module.

Dot Matrix Indicator Programming

MachineShop Supplemental Installation

USB485. USB to RS485 Converter Card. User Manual for connecting with Windows Vista Version 1.01

G-MAX TM. ATX Series User s Manual

1. Installation DEVICENET INTERFACE. Install the DeviceNet Interface using the following procedure:

MISUMI SUPPORT SOFTWARE. RS-Manager. User s Manual C1 / C21 / C22 / P1 EXWM KE114. Ver. 2.00

Procedures to Install Eye Com's ImageMouse and ImageMouse Plus using Windows XP platform

1. Introduction. 2. Installation MODBUS INTERFACE

Network USB over IP Server With 1-USB2.0 Port. User Manual V1.0

STOP! Read these instructions before connecting the PR3 to your Computer

Controller Setting Kit Installation Manual (For Windows 8.1 )

USB DRIVER INSTALLATION GUIDE

3700 SERIES USER MANUAL

USB RS485/RS422 Converter INTRODUCTION USB-i485 USB-i485 SPECIFICATIONS USB-i485 USB-i485 NOVUS AUTOMATION 1/8

Introduction. 1 available USB type A (downstream) port. Windows 98, Windows ME, Windows 2000, Windows XP,

TRP-C08S. USB To 1* RS232 and 1*RS422/485 Isolated Converter. User s Manual. Printed Jun Rev 1.2

Opal Pro to DeviceNet. Opal Pro MS6 SERIES. DeviceNet Interface Users Manual. Revision Page 1

tiptel 545/570 office tiptel 545/570 SD PC Software and Driver Installation in Windows XP/Windows 7 (32/64 Bit)

Soft Starter Remote Operator. Section 1.0 Introduction 1.1 Important user information General Manual description...2.

Serial 2-Port ExpressCard

ASSAN ESC PC Interface Software User s Guide

Option H10, Multi-line 2 unit with USB service port. To be used when the multi-line 2 unit service port is USB type

Serial PCi Card user manual

PumpDrive DPM. Installation and Operating Instructions Dual Pump Module (DPM) /4--10

TRP-C08S. USB to 1 RS232 and 1 RS422/485 Isolated Converter. User s Manual

Cyber 2S1P 950 PCI Quick Installation Guide

PIN Pad: Installation

Series 3700 Screw Terminal Assemblies Installation Instructions

Parallel PCi Card user manual

Cyber 2S1P 950 PCI Quick Installation Guide

Installation Guide UD70 MD29. Second Processor Options for Unidrive and Mentor II. Part Number: Issue Number: 3.

SIMATIC. Communications processor CP First Steps in Commissioning. Getting Started 09/2008 A5E

Serial PC Card. guide. Model MAN QIG

TRP-C08X. USB To 4 RS232/422/485 Converter. User s Manual

Windows XP Software Installation Instructions GCC Elite Series Printers

FX-USB-AW/FX3U-USB-BD. USER'S MANUAL USB Driver Installation Edition

Serial/Parallel Combo PCI

The SC812/SC812L Chassis Series Installation Guide

TRP-C08M. USB To 4 RS232/422/485 Isolated Converter. User s Manual. Printed Jun Rev 1.0

1. Installing the Drivers for Windows

Power Xpert Meter 2000 Gateway Card Kit

2-Port RS232 Serial PCIe with UART Quick Installation Guide

Power Xpert Meter 2000 Gateway Card Kit

USB TO SERIAL CONVERTER

USER MANUAL for USB 2.0 Card Bus

USB to Serial Converter manual

CellSync Manager. User Manual F8V7D006-SS F8V7D008-SS. Get online and synchronize anywhere. Web Access. Phone Book Manager

TigerStop Ethernet-to-Serial Converter Installation & User s Guide v4.2

MF9300. Software setup guide

User s Manual. PC-Based Measurement Instruments. Setup Guide for Windows Vista IM E. 1st Edition

PC9/P9 Floppy Drive Replacement

Magnetek Material Handling IMPULSE LINK 4.1 Basic Instruction Manual

Opal Pro AB Ethernet IP. Opal Pro MS6 SERIES. AB Ethernet IP Interface Users Manual. Revision Page 1

Parallel PCI 1P. Quick Installation Guide. Introducing the Parallel PCI 1P. Features and Benefits. System Requirements.

CyberSerial Dual PCIe Quick Installation Guide

USB-Link Technical Guide

1S1P Mini PCIe with UART Quick Installation Guide

Version S Cincinnati, Suite 105 Tulsa, OK (918) Fax (918)

SENSORLESS-BLDC-MOTOR-RD

Windows XP - MVX Printer Driver Installation

H4 Series Hardware Replacement Guide

Quick Start Guide. Variable Speed Drive. Part Number: Issue: 3

Adaptec AUA Multi-Card Media Reader. Installation Guide

Cyber 1S1P PCI Quick Installation Guide

EPS 06 in rear housing type A1

Bellatrix Systems, Inc. Maintenance Test Station For Windows XP Version 1.0. User Manual

10 How to Setup a Home or Small Network

8 TS4-DDH T i g e r S t o p M a n u a l D a t a D o w n l o a d i n g. May 2006 Version 3.5 ~ 4.72 Hardware

CyberParallel Dual PCIe

MC-12 Software Installation Instructions

Serial PCI MODEL MAN UM

Printer Driver. User Guide. Macintosh

User s Manual Printed Sep Rev 1.2

MSI MP54GS (MS-6818) Wireless 11g MiniPCI Card. (For OEMs use only) User s Guide

Cyber I/O PCI Quick Installation Guide

USB Serial Converter

Transcription:

General Information The manufacturer accepts no liability for any consequences resulting from inappropriate, negligent or incorrect installation or adjustment of the optional parameters of the equipment or from mismatching the starter with the motor. The contents of this guide are believed to be correct at the time of printing. In the interests of commitment to a policy of continuous development and improvement, the manufacturer reserves the right to change the specification of the product or its performance, or the content of the guide without notice. All rights reserved. No parts of this guide may be reproduced or transmitted in any form or by any means, electrical or mechanical including, photocopying, recording or by an information storage or retrieval system, without permission in writing from the publisher. Copyright December 2017 Nidec

Contents 1. Introduction... 4 2. Important User Information... 4 3. Installation... 4 3.1 Installation Procedure... 4 3.2 Physical installation... 4 4. Connection... 5 5. Configuration... 6 6. Specifications... 7 USB Module: User Guide 3

1. Introduction The USB Module can be used in conjunction with Digistart-Soft to manage Nidec soft starters. These instructions detail the installation, set-up and configuration of the USB Module. For details on using Digistart-Soft, refer to the Digistart-Soft help file. NOTE For Digistart Soft to communicate with a soft starter via the USB Interface, Digistart Soft must be configured to use the AP ASCII or AP Binary protocols. 2. Important User Information Observe all necessary safety precautions when controlling the soft starter remotely. Alert personnel that machinery may start without warning. It is the installer's responsibility to follow all instructions in this manual and to follow correct electrical practice. 3. Installation CAUTION Remove mains and control voltage from the soft starter before attaching or removing accessories. Failure to do so may damage the equipment. 3.1 Installation Procedure 1. Remove control power and mains supply from the soft starter. 2. Attach the module to the soft starter as illustrated. 3. Apply control power to the soft starter. 3.2 Physical installation 1. Fully pull out the top and bottom retaining clips on the module. 2. Line up the module with the comms port slot. 3. Push in the top and bottom retaining clips to secure the module to the starter. Figure 3-1 Attach the module to the starter 1 2 3 10178.B Figure 3-2 Remove the module from the starter Remove the module using the following procedure: 1. Remove control power and mains supply from the soft starter. 2. Take the module off-line. 3. Disconnect all external wiring from the module. 4. Fully pull out the top and bottom retaining clips on the module. 5. Pull the module away from the soft starter. 03550.B 4 USB Module: User Guide

4. Connection Figure 4-1 USB Module connections Digistart D2 Digistart D3 1 1 2 2 3 09528.A 3 09529.A Digistart D2 Digistart D3 (Remote mode) CSL, DI2: Stop input DI2, +24V: Stop input DI3, +24V: Reset input USB Module USB Module USB port USB port Digistart D2: For the USB Module to accept serial commands, a link must be fitted across terminals CSL-DI2 on the soft starter. Digistart D3: Input links are required across the stop and reset inputs if the soft starter is being operated in Remote mode. In Local mode, links are not required. If the Starter Disable function is not required, change the setting of Pr 3A or connect a link across DI4, +24V. NOTE Digistart D3: Control via the serial communication network is always enabled in local control mode, and can be enabled or disabled in remote control mode (Pr 3O Comms in Remote). See the soft starter user manual for parameter details. USB Module: User Guide 5

5. Configuration To bring the USB Module on-line: 1. Remove control power and mains supply from the soft starter. 2. Attach the module to the soft starter as illustrated. 3. Connect the module to the PC via a USB cable. The PC should detect the module and the Hardware Update Wizard will open. 4. Install the USB driver to operate the module as follows. The driver can be downloaded from. Welcome to the Found New Hardware Wizard Windows will search for current and updated software by looking on your computer, on the hardware installation CD, or on the Windows Update Web site (with your permission). Read our privacy policy This wizard helps you install software for: FT232R USB UART Can Windows connect to Windows Update to search for software? Yes, this time only Yes, now and every time I connect a device No, not this time If your hardware came with an installation CD or floppy disk, insert it now. What do you want the wizard to do? Install the software automatically (Recommended) Install from a list or specific location (Advanced) Click Next to continue. Click Next to continue. 08588.A Please choose your search and installation options. Search for the best driver in these locations. Select the folder that contains drivers for your hardware. Use the check boxes below to limit or expand the default search, which includes local paths and removable media. The best driver found will be installed. Search removable media (floppy, CD-ROM...) Include this location in the search C:\Documents and Settings\user\Desktop\USB Comm Don t search. I will choose the driver to install. Browse My Documents My Computer My Network Places USB Comms Drivers Win98_ME WinXP_Vista amd64 i386 Choose this option to select the device driver from a list. Windows does not guarantee that the driver you choose will be the best match for your hardware. To view any subfolders, click a plus sign above. OK Cancel 08589.A < Back Next > Cancel Click on Ok, then Next. The software will install. If you see a prompt, click Continue Anyway. Once installation is complete, click Finish. 5. The PC will prompt you to install serial port driver software. Repeat the procedure in Step 4. You may need to restart your PC once the driver software is installed. 6. Identify the USB Serial Port assignment by checking Control panel > System > Hardware > Device Manager > Ports (COM & LPT). 6 USB Module: User Guide

Computer Disk drives Display adapters DVD/CD-ROM drives Floppy disk controllers Floppy disk drives Human Interface Devices IDE ATA/ATAPI controllers IEEE 1394 Bus host controllers Keyboards Mice and other pointing devices Monitors Network adapters Ports (COM & LPT) Communications Port (COM1) ECP Printer Port (LPT1) Intel(R) Active Management Technology - SOL (CO USB Serial Port (COM5) Processors 08590.A NOTE If the USB port is not shown, disconnect then reconnect the cable. If the problem persists, restart your PC. 7. Open Digistart-Soft and change the settings as follows: Protocol: Digistart D2 Series = ASCII; Digistart D3 = Binary Baud rate: 9600 Address: 20 Port: Use the serial port number identified above 8. Apply control voltage to the soft starter and bring the Master on-line. NOTE The starter may trip on Starter Comms while the Master is off-line. Reset the soft starter and place the Master on-line. NOTE The drivers will configure the USB port that the module is connected to. You must use the same physical USB port every time you connect the module to the PC. 6. Specifications Enclosure Dimensions... 40 mm (W) x 166 mm (H) x 90 mm (D) Weight... 250 g Protection... IP20 Mounting Spring-action plastic mounting clips (x 2) Connections Soft starter... 6-way pin assembly Network... USB-B Maximum cable length... 3 metres (not supplied) Settings Protocol... AP Binary or AP ASCII Address... 20 Data rate (bps)... 9600 USB Module: User Guide 7