The specifications for the Cisco 7304 router are listed in Table A-1.

Similar documents
Cisco ASR 1001-X Router Specifications

Cisco ASR 1000 Series Router Specifications

E1 and T1 RJ-48 Cable Pinouts on page 208. Fast Ethernet 12-port Cable Pinouts on page 211

Connector and Cable Specifications

Cable Pinouts. SRP I/O Module

Connector and Cable Specifications

NPE-G2 Overview. Supported Platforms CHAPTER

Appendix A Cable Pinouts

Cisco - Ethernet 100BaseTX and 10BaseT Cables: Guidelines and Specifications

Introducing the Cisco NAM 2220 Appliance

Cable Specifications. Interface Specifications. Fiber-Optic Specifications APPENDIXB

NPE-G2 Overview. Supported Platforms CHAPTER

Overview. Port Adapter Overview CHAPTER

Installing the Cisco 2524 and Cisco 2525 Routers

Connector and Cable Specifications

Note: For BANDIT II, BANDIT III, or VSR-1200 specifications, see the BANDIT II, BANDIT III, and VSR-1200 Document Set. Function

Installing the Cisco AS5400XM Universal Gateway

Overview of the Cisco 2524 and Cisco 2525 Routers

Cable and Port Specifications

Installing and Removing SDRAM and DRAM

RS-232 Connector Pin Assignments

Arm-based DIN-rail industrial computers with 4 serial ports, 2 LAN ports, 8 DI/DO, and VGA. Features and Benefits. Certifications

Cable and Port Specifications

Installing the Cisco ATA

Introducing the Cisco 1121 Secure Access Control System Hardware

EDR-G902/G903 Quick Installation Guide

Frame Relay Cabling This section describes the cabling and connector pinouts for the Frame Relay cards.

VL BPC 100. Valueline configurable box PC. Data sheet 3063_en_E. 1 Description. 2 Features

Route Processor. Route Processor Overview. This chapter describes the route processor (RP) card. The following sections are included:

Connector and Cable Specifications

Cable and Port Specifications

Perle SMI Media Converter Installation Guide

JetBox 9300/9310 User Manual. Hardware

Perle SMI Media Converter Installation Guide

FastHub Ports and Cabling Information

EPC-APL. Quick Reference Guide. Intel Pentium /Celeron Processor Fanless Tiny System. Copyright Notice. 1 st Ed 12 September 2017

Select a Data Communication Interface

Overview. Features CHAPTER

VL BPC MINI. A configurable industrial computer platform. Data sheet 2930_en_F. 1 Description. 2 Features

Cisco MCS 7815-I2 Unified CallManager Appliance

Junos WebApp Secure 5.0 Hardware Guide

VL BPC MINI. A configurable industrial computer platform Intel Atom Z510PT CMAT IPC Module Option [I28] AUTOMATION Data Sheet 2930_en_A.

GEU Port Gigabit Switch

EDR-810 Series Quick Installation Guide

Arm-based palm-sized industrial computers with 2 serial ports and 2 LAN ports. Features and Benefits. Certifications

Preparing to Install the Cisco AS5350XM Universal Gateway

Catalyst 2960-X and 2960-XR Switch Hardware Guide

Connector and Cable Specifications

iopac 8020 Series Rugged modular RTU controllers Overview Programmable RTU Controllers Ethernet bypass feature for seamless data transmission

GT- IRDM-9603 Product description Rev. 2 17/06/2014

Carrier Board Socket Modem CAB/MOD1

iopac 8020 Series Rugged modular RTU controllers Overview Programmable RTU Controllers Ethernet bypass feature for seamless data transmission

Overview of the Cisco MWR 1941-DC Router

Cisco MCS 7815-I1 Unified CallManager Appliance

Low Profile Hub. User Manual

DeviceMaster RTS 16-Port Hardware Installation

High Power over Ethernet Midspans PD Port Model PD Port Model

Cabling Guide for Console and AUX

Extension module for graphic Web functions for one automation station

Matrix-700 Linux-Ready Cortex-A5 Industry IoT Gateway Hardware Guide

Enhanced Mini-Chansim Model VCS-232

Extension module for BACnet over Ethernet / IP and graphic Web functions

Overview. Port Adapter Overview CHAPTER

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

Cisco MCS 7845-H1 Unified CallManager Appliance

UC-7400 Plus Hardware User s Manual

Extension module for Web functions generic

Cisco MCS 7815-I2. Serviceable SATA Disk Drives

Cisco MCS 7825-I1 Unified CallManager Appliance

NPort 6600 Series Quick Installation Guide

NPE-300 and NPE-400 Overview

SFP-GIG-T-LEG. 1.25Gbps SFP Copper Transceiver

Cisco 7200VXR Series NPE-G2 Network Processing Engine

BlueTooth Carrier Board CAB/BT1

Industrial PC IPC191V2. General Operating, Maintenance and Installation Manual. Hardware Platform Protocol Converter

QUICK START GUIDE Cisco 7301 Router

IES User Manual. 6 GE + 2 SFP Unmanaged Switch -20 to 60C, DIN-rail. v

4 10/100/1000T Mini-GBIC with 4 IEEE 802.3at High Power PoE Industrial Wide Temperature Switch. User Manual SISTP LRT

Product Overview. Switch Model

Industrial 5-Port Fast Ethernet Switches with SFP Slot and optional 4 PoE PSE Ports. Basic Model: KSD-541 PoE Model: KSD-541-P. Installation Guide

USER S MANUAL. PH232Ex1. #1 RS-232 Serial Port to Ethernet, Terminal Server/Client. Doc No: PH232Ex1-UM-001 IPEX. (IP Electronix)

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

C H A P T E R Figure 1-1 Modular Stacked Network System 1-1

General Operating, Maintenance and Installation Manual

16/24 Port 10/100 Auto-Sensing Dual Speed Ethernet Switch

3.1 I-7560 Pin Assignment and Specifications: Introduction

Fast Ethernet Interface Processor (FEIP) Installation and Configuration

Industrial 5-Port Fast Ethernet Switches. with SFP Slot and optional 4 PoE PSE Ports. Basic Model: KSD-541. PoE Model: KSD-541-HP. Installation Guide

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

Cisco ONS CL Shelf Assembly Hardware

AI port High Speed Asynchronous Line Card Installation Guide

Installing the IPS 4345 and IPS 4360

IES User Manual. 8 FE + 1 MM SC Unmanaged Switch -40 to 75, DIN-rail. v

Cisco MCS 7845-I2 Unified Communications Manager Appliance

Technical Specifications

HEC. General Operating, Maintenance and Installation Manual

Integrated Ultra320 Smart Array 6i Redundant Array of Independent Disks (RAID) Controller with 64-MB read cache plus 128-MB batterybacked

Overview of the Cisco VG224 Voice Gateway

F1000 User's Manual. (Version: V1.01)

Installing Power Modules

Transcription:

APPENDIX A This appendix provides system and component specifications for the Cisco 7304 router. The following topics are found in this appendix: System, page A-1 Processor and Memory and Configurations, page A-2 Gigabit Ethernet SFP Port and Cabling Information, page A-4 Gigabit Ethernet SFP Port and Cabling Information, page A-4 Gigabit Ethernet RJ-45 Port Pinouts, page A-4 NSE-100 and NSE-150 Fast Ethernet RJ-45 Port Pinouts, page A-5 Console and Auxiliary Port Signals and Pinouts, page A-7 System The specifications for the Cisco 7304 router are listed in Table A-1. Table A-1 Cisco 7304 System Description Specification Dimensions (H x W x D) 6.94 in. x 17.6 in. x 20.5 in. (17.63 cm x 44.70 cm x 52.07 cm) Weight 28 lbs. (12.73 kg) (Chassis without line cards) Heat dissipation 700W (2387 BTU) maximum AC-input power 800 VA maximum (single supply configuration) AC-input voltage rating 100-240 VAC 1 wide input with power factor correction AC-input current rating Rated for 8A when Vin = 100 VAC or 4A when Vin = 200 VAC. AC-input frequency rating 50 60 Hz 2 AC-input cable 18 AWG 3 three-wire cable, with a three-lead IEC-320 receptacle on the power supply end, and a country-dependent plug on the power source end DC-input power 750 VA maximum configuration DC-input voltage ratings 48 VDC nominal, maximum range 48 VDC to 60 VDC ( 40.5 to 72 VDC supply tolerance) A-1

Processor and Memory and Configurations Table A-1 Cisco 7304 System (continued) Description DC-input current ratings DC-input cable Specification 16A at 48 VDC (18.5A at 40.5 VDC, 10.4A at 72 VDC supply tolerance) 12 AWG only 1. VAC = volts alternating current 2. Hz = hertz 3. AWG = American Wire Gauge Processor and Memory and Configurations Table A-2 NSE-100 Processor and Memory Memory Type Memory Size Quantity Description Location SDRAM 1 256 or 512 MB 1 256-MB or 512-MB SODIMM U19 Non-upgradeable boot ROM Upgradeable boot ROM Flash memory disk 0: 64 MB, 128 MB, or 256 MB bootdisk: 32 MB Primary cache 16 KB (instruction), 16 KB (data) 512 KB 1 OTP 2 ROM for the ROM monitor program (ROMmon) 1 MB 2 Programmable ROM U14, U34 1. On November 3, 2003, the 512 MB SDRAM memory option became the default SDRAM memory option for the NSE-100 Processor. The 256 MB SDRAM memory option is still available as a spare, but the 128 MB SDRAM memory option that was once available for the NSE-100 Processor became unavailable for the NSE-100 Processor. 2. OTP = one-time programmable. Although the OTP ROMmon cannot be upgraded, the boot code can be upgraded using the Cisco IOS software. If the boot code is upgraded, the updated boot code is stored in upgradeable boot ROM. U11 2 CompactFlash Disks P2 (bootdisk:), P3 (disk0:) RM7000 processor; internal cache U2 Secondary cache 256 KB RM7000 processor; internal unified instruction U2 and data cache Tertiary cache 1 MB (fixed) RM7000 processor; external cache U5, U32, U33 Table A-3 NSE-150 Memory Memory Type Memory Size Quantity Description SDRAM 2GB 1 Built-in 2GB SDRAM Non-upgradeable boot 512 KB 1 OTP ROM for the ROM monitor (ROMmon) ROM Upgradeable boot 2 MB 2 Programmable ROM ROM NVRAM 2 MB 1 Stores the system configuration and environmental monitoring logs A-2

Processor and Memory and Configurations Table A-3 NSE-150 Memory Memory Type Memory Size Quantity Description Flash Disk memory (internal Compact Flash slot; bootdisk:) Flash Disk memory (external Compact Flash slot; disk0:) 256 MB 1 Stores images, configurations, or other files. 256 MB Compact Flash Disks 256 MB 1 Stores images, configurations, or other files. 256 MB Compact Flash Disks Table A-4 NPE-G100 Processor and Memory Memory Type Memory Size Quantity Description Location on NPE-G100 Board SDRAM 1 GB 2 2 512 MBSODIMMs J3, J4 Non-upgradeable boot ROM 512 KB 1 OTP 1 ROM for the ROM monitor (ROMmon) U15 NVRAM 512 KB 2 Configuration and crash information files U1, U7 Upgradeable 1 MB 2 Programmable ROM U26, U64 boot ROM Flash memory disk0: 256 MB 1 CompactFlash Disks External bootdisk: 32 MB (disk0:) Primary cache 16 KB BCM 1250 processor system, internal cache U24 (instruction), 16 KB (data) Secondary cache 512 KB BCM 1250 processor system; internal, unified instruction and data cache Memory Type Memory Size Quantity Description 1. OTP = one-time programmable. Although the OTP ROMmon cannot be upgraded, the boot code can be upgraded using the Cisco IOS software. If the boot code is upgraded, the updated boot code is stored in upgradeable boot ROM. U24 Location on NPE-G100 Board Table A-5 NSE-100 SODIMM Configurations Configurable Memory Total SODIMM Quantity Product Number 128 MB U19 1 128-MB SODIMM 7300-MEM-128= 256 MB U19 1 256-MB SODIMM 7300-MEM-256= 512 MB U19 1 512-MB SODIMM 7300-MEM-512= A-3

Gigabit Ethernet SFP Port and Cabling Information Table A-6 NPE-G100 SODIMM Configurations Configurable Memory Total SDRAM SDRAM SODIMMs Quantity Product Number 1 GB J3 and J4 2 512-MB SODIMMs 7304-MEM-G100-1GB= Table A-7 CompactFlash Disk Configuration Memory Size Processor Engine Product Number 64 MB NSE-100, NSE-150, or 7300-I/O-CFM-64MB= NPE-G100 128 MB NSE-100, NSE-150, or 7300-I/O-CFM-128MB= NPE-G100 256 MB NSE-150 or NPE-G100 7300-I/O/-CFM-256MB= Gigabit Ethernet SFP Port and Cabling Information For information on the GBICs that are supported on the NSE-100 and the SFPs that are supported on the NSE-150, see the Cisco 7304 Network Services Engine Installation and Configuration Guide. For information on the SFPs that are supported on the NPE-G100, see the SFP Port and Cabling Information section of the Cisco 7304 Network Processing Engine Installation and Configuration Guide. Gigabit Ethernet RJ-45 Port Pinouts The Cisco 7304 router has RJ-45 ports for either two or three 10/100/1000 Ethernet/Fast Ethernet/Gigabit Ethernet connections, depending on whether you have an NSE-100 or NPE-G100 installed (the NSE-150 only uses SFPs for Gigabit Ethernet connectivity). The RJ-45 ports support IEEE 802.3ab (Gigabit Ethernet) and IEEE 802.3u (Fast Ethernet) interfaces compliant with 10BASET, 100BASETX, and 1000BASET specifications. The RJ-45 ports support standard straight-through and crossover Category 5 UTP cables with RJ-45 connectors. Cisco Systems does not supply Category 5 UTP cables; these cables are available commercially. Warning To avoid electric shock, do not connect safety extra-low voltage (SELV) circuits to telephone-network voltage (TNV) circuits. LAN ports contain SELV circuits, and WAN ports contain TNV circuits. Some LAN and WAN ports both use RJ-45 connectors. Use caution when connecting cables. Figure A-1 shows an RJ-45 port and connector. Table A-8 lists the pinouts and signals for the RJ-45 port. A-4

NSE-100 and NSE-150 Fast Ethernet RJ-45 Port Pinouts Figure A-1 RJ-45 Port and Connector 12345678 1 57574 1 RJ-45 connector Table A-8 RJ-45 Receptacle Pinouts Pin FE Signal GE Signal 1 TX DATA+ 1 Tx A+ 2 TX DATA Tx A 3 RX DATA+ 2 Rx B+ 4 N/C Tx C+ 5 N/C Tx C 6 RX DATA Rx B 7 N/C Rx D+ 8 N/C Rx D 1. TX DATA = Transmit Data 2. RX DATA = Receive Data NSE-100 and NSE-150 Fast Ethernet RJ-45 Port Pinouts The Cisco 7304 router NSE-100 has RJ-45 ports for the one Fast Ethernet connection. The RJ-45 ports support IEEE 802.3,( Ethernet), and IEEE 802.3u (Fast Ethernet) interfaces compliant with 10BASET and 100BASETX specifications. The RJ-45 port supports standard straight-through and crossover Category 5 UTP cables with RJ-45 connectors. Cisco Systems does not supply Category 5 UTP cables; these cables are available commercially. Warning To avoid electric shock, do not connect safety extra-low voltage (SELV) circuits to telephone-network voltage (TNV) circuits. LAN ports contain SELV circuits, and WAN ports contain TNV circuits. Some LAN and WAN ports both use RJ-45 connectors. Use caution when connecting cables. Figure A-2 shows an RJ-45 port and connector. Table A-9 lists the pinouts and signals for the RJ-45 port. A-5

NSE-100 and NSE-150 Fast Ethernet RJ-45 Port Pinouts Figure A-2 RJ-45 Port and Connector 12345678 1 57574 1 RJ-45 connector Table A-9 RJ-45 Receptacle Pinouts Pin 1 Description 1 TxD+ 2 2 TxD 3 RxD+ 3 6 RxD 1. Any pin not referenced is not connected. 2. TxD = Transmit Data 3. RxD = Receive Data Note With reference to the RJ-45 pinout in Table A-9, proper common-mode line terminations should be used for the unused Category 5 UTP cable pairs 4/5 and 7/8. Common-mode termination reduces electromagnetic interference (EMI). Use the pinouts shown in Figure A-3 for straight-through and crossover twisted-pair cable connections for your RJ-45 interface cabling requirements. Figure A-3 Ethernet Pinouts Straight-Through or Crossover Cable 1 TxD+ 2 TxD 1 2 3 4 3 5 1 RxD+ 2 RxD 1 TxD+ 2 TxD 1 TxD+ 2 TxD 3 RxD+ 6 RxD 3 TxD+ 6 TxD 3 RxD+ 6 RxD 3 RxD+ 6 RxD 57607 1 Straight-though cable pinout, Ethernet port to a hub or repeater 2 Crossover cable pinout, Ethernet port to a DTE 3 Ethernet port 4 Hub 5 DTE A-6

Console and Auxiliary Port Signals and Pinouts To determine whether a UTP cable is a crossover cable or a straight-through cable, hold the two RJ-45 connectors next to each other so you can see the colored wires inside the ends. Examine the sequence of colored wires to determine the type of cable, as follows: Straight-through The colored wires are in the same sequence at both ends of the cable. Crossover The first (far left) colored wire at one end of the cable is the third colored wire at the other end of the cable. Console and Auxiliary Port Signals and Pinouts The Cisco 7304 router does not support Data Carrier Detect (DCD). Table A-10 lists the RJ-45 console port signals. Table A-10 Console Port Signals Pin Signal Direction Description 1 CTS Out Clear To Send (tracks RTS) 2 DTR Out Data Terminal Ready (always on) 3 TXD Out Transmit Data 4 GND Signal Ground 5 GND In Signal Ground 6 RXD Out Receive Data 7 DSR Out Data Set Ready (always on) 8 RTS In Ready To Send Table A-11 lists the RJ-45 auxiliary port signals. Table A-11 Auxiliary Port Signals Pin Signal Direction Description 1 RTS Out Ready To Send 2 DSR Out Data Set Ready 3 RXD In Receive Data 4 GND Signal Ground 5 GND Signal Ground 6 TXD In Transmit Data 7 DTR In Data Terminal Ready (always on) 8 CTS In Clear To Send (tracks RTS) A-7

Console and Auxiliary Port Signals and Pinouts A-8