USER MANUAL. Longo programmable controller LPC-2.CH1M Card Holder module. Version 3

Similar documents
USER MANUAL. Longo programmable controller LPC-2.CA1M Card Reader module. Version 2

USER MANUAL. Longo programmable controller LPC-2.CR1 Card Reader module. Version 5

USER MANUAL. Longo programmable controller LPC-2.AQ1 Air Quality module. Version 1

USER MANUAL. Longo programmable controller LPC-2.ID2 RFID Card holder. Version 8

USER MANUAL. Longo programmable controller LPC-2.IR2V Multisensor. Version 4

USER MANUAL. Longo programmable controller LPC-2.SM6 Multisensor. Version 4

USER MANUAL. Longo programmable controller LPC-2.EO1 EnOcean Wireless module. Version 1

USER MANUAL. Longo programmable controller LPC-2.MC8 Main module. Version 10

USER MANUAL. Longo programmable controller LPC-3.IOR.001 Input Output Relay PLC. Version 2

USER MANUAL. 7" Touch Screen LPC-2.PC2. Version 0

Transponder card reader

Operating instructions AS-i SmartLine module AC3200 AC /00 06/2016

Transponder card holder

Installation Instructions Model LFMWLT450, Class 1 Series AC-DC Power Supply

Table of Contents SMARTEH ACCESS SYSTEM DESCRIPTION SMARTEH ACCESS 2

GENERAL BUILDING AUTOMATION CATALOGUE. Product Overview

1 IF-810 or IF-811 Terminal (Slave) 2 Intended Use. 3 Assembly and Installation _V IF-810/IF-811

User Manual. Printer P-52RUE

IF-80x Outdoor Terminal

Line reactors SINAMICS. SINAMICS G130 Line reactors. Safety information 1. General. Mechanical installation 3. Electrical installation

ATS-16 HV USER MANUAL. Automatic Transfer Switch 16A / 230Vac V090318

Operating Manual. English. Digital-Analog Converter DACON8-UMB.

Operating instructions. Switching amplifier DN0210 DN / / 2015

GENERAL BUILDING AUTOMATION CATALOGUE. Product Overview

TRC-190 User s Manual

BS 287 DUAL CHANNEL POWER SUPPLY. User Manual. January 2017 V1.0

Communication Interface for SMA Inverters SMA BLUETOOTH PIGGY-BACK

Industriefunkuhren. Technical Manual. Signal Converter. for DIN Rail Mounting Series 4800xx-yy ENGLISH

ABB Drives. User s Manual I/O Module Adapter AIMA-01

CoolPlug CooLinkHub HVAC Bridge. Quick Installation Guide

1 IF-812 or IF-815 Terminal (Slave) 2 Intended Use. 3 Assembly and Installation _V IF-812/IF-815

HPS-M -2 DIFFERENTIAL PRESSURE TRANSMITTER. Mounting and operating instructions

Blitzer Strobe. User Manual. Order code: EQLED366

BS 181 SINGLE CHANNEL POWER SUPPLY USER MANUAL

Microbar COB System. User Manual. Order code: EQLED137

Operating instructions. Speed monitor D / / 2014

Gobo Projector XP 80W

CoolPlug CooLinkHub HVAC Bridge. Quick Installation Guide

REX F-0-9 Standalone or Access Controller

UV Power Flood. User Manual. Order code: EQLED029

CS2 DMX Distribution Splitter

RGB Power Batten. User Manual. Order code: EQLED032

M-Bus Central Unit. Use

ATS22D75S6U. Main. Range of product Altistart 22. Component name. Factory setting current. Utilisation category. IP degree of protection

8 Button RS232/IR. Control Panel. MuxLab Inc A / SE A

ATS22D88S6U. ATS22D88S6U soft starter-ats22-control110v-power 208V(25hp)/230V(30hp)/460V(60hp)/575V(75hp) Product data sheet Characteristics.

PF LED Profile. User Manual

PHOENIX CONTACT - 07/2006

Blitzer RGB Strobe. User Manual. Order code: EQLED365

FEATURES FEATURES. Macro Function Usage Supports strong Visual Basic script language which includes more than 500 built-in functions.

ATS22D47S6U. Main. Range of product Altistart 22. Component name. Factory setting current. Utilisation category. IP degree of protection

Installation Guide. QBox-V6. Standalone/Spare V6 SDI QBox. Standalone/Spare V6 SDI QBox. Part No. A

REDUNDANCY MODULE TSP-REM360 AND TSP-REM600

MOXA EtherDevice Switch & PoE Splitter

Kinetix 300 Memory Module Programmer

CMU 100 RS485 to 7x, 6x, 5x, 4x Multimode Fiber Optic Star Coupler User Manual

HITACHI. EH-150 series PLC EH-RTD8 Resistance Temperature Detective input module Instruction manual. Safety precautions

Serial PROFIBUS Interface

USERS GUIDE ASP-18H-4K. HDMI 4K2K 1x8 Splitter with EDID Management. Manual Number:

LASERMET SLIMJIM LED SIGN INSTRUCTION MANUAL LEDS-SJ XXX

Rhino Redundancy Module PSM24-REM360S. Operating Instructions

ATS22D75S6 soft starter-ats22-control 220V-power 230V(18.5kW)/ V(37kW)/500V(45kW)

INJ-24A Series Quick Installation Guide

ATS22D17Q soft starter-ats22-control 220V-power 230V (4kW)/ V(7.5kW)

Installation- and Operating instructions for CU Ethernet Controller with USB Input. Version: 1.4 Date:

Access Terminal IF-800

Crossfire. User Manual. Order code: EQLED061

LED Pixel Rail Drive 640 controller. user manual

Display Panel BAT 100 LSN. en Operation Guide

BS 181 SINGLE CHANNEL POWER SUPPLY USER MANUAL

Flexoled FTP3HP RGB LED DMX Driver

ATS22C21S6U softstarter-ats22-control110vpower208v(60hp)/230v(75hp)/460v(150hp)/575v(200hp)

MGate 5105-MB-EIP Quick Installation Guide

ATS22D17Q soft starter-ats22-control 220V-power 230V(4kW)/ V(7.5kW)

USER MANUAL. RC-74DL Master Room Controller MODEL: P/N: Rev 4

The power behind competitiveness. Delta Infrasuite Power Management. Power Distribution Unit. User Manual.

Technical Datasheet clima RCM-FC 1. Product description

CEM M-RS485 INSTRUCTION MANUAL (M014B A)

Accessories for Sunny Central COMMUNICATION CABINET (COM-C)

Solar Combiner Enclosure

Operating instructions. Standstill monitor A / / 2011

ATS22D62Q soft starter-ats22-control 220V-power 230V(15kW)/ V(30kW)

USER MANUAL. SL-10 Master Room Controller MODEL: P/N: Rev 4

KRAMER ELECTRONICS LTD. USER MANUAL MODEL: RC-76R/RC-78R Room Controllers. P/N: Rev 5

CU USB-Extender-Rx (USB and DVI Extender) Version: 0.3 Date:

SAFETY PRECAUTIONS CAUTION WARNING CAUTION. Thank you for purchasing ig5a Series Profibus Communication Module

CONFIGURATION HANDBOOK

TECHCONNECT TC2-HDMI14 OWNERS MANUAL

QUINT-BUFFER/24DC/24DC/40

LED Commander 16/2 DMX controller. user manual

CPCI System Subrack 1 U

ABB Drives. User s Manual. Digital I/O Extension Module RDIO-01

LED W RGBA User Manual

ADC7520 SERIES. 1600W Battery Chargers and Power Supplies

ABB Drives. User s Manual. Analogue I/O Extension Module RAIO-01

Installation instructions Ethernet switch EC / / 2011

User Manual Gateway component for EtherNet/IP

Wristband Capturer Technical Manual

3/4 U CPCI Serial Case System

RAD-DO8-IFS. I/O extension module, eight digital transistor outputs. Data sheet. 1 Description

Transcription:

USER MANUAL Longo programmable controller LPC-2.CH1M Card Holder module Version 3 SMARTEH d.o.o. / Poljubinj 114 / 5220 Tolmin / Slovenia / Tel.: +386(0)5 388 44 00 / e-mail: info@smarteh.si / www.smarteh.si

Written by SMARTEH d.o.o. Copyright 2017, SMARTEH d.o.o. User Manual Document Version: 3 May, 2017 i

STANDARDS AND PROVISIONS: Standards, recommendations, regulations and provisions of the country in which the devices will operate, must be considered while planning and setting up electrical devices. Work on 100.. 240 V AC network is allowed for authorized personnel only. DANGER WARNINGS: Devices or modules must be protected from moisture, dirt and damage during transport, storing and operation. WARRANTY CONDITIONS: For all modules LONGO LPC-2 if no modifications are performed upon and are correctly connected by authorized personnel in consideration of maximum allowed connecting power, warranty of 24 months is valid from the date of sale to the end buyer, but not more than 36 months after delivery from Smarteh. In case of claims within warranty time, which are based on material malfunctions the producer offers free replacement. The method of return of malfunctioned module, together with description, can be arranged with our authorized representative. Warranty does not include damage due to transport or because of unconsidered corresponding regulations of the country, where the module is installed. This device must be connected properly by the provided connection scheme in this manual. Misconnections may result in device damage, fire or personal injury. Hazardous voltage in the device can cause electric shock and may result in personal injury or death. NEVER SERVICE THIS PRODUCT YOURSELF! This device must not be installed in the systems critical for life (e.g. medical devices, aircrafts, etc.). If the device is used in a manner not specified by the manufacturer, the degree of protection provided by the equipment may be impaired. Waste electrical and electronic equipment (WEEE) must be collected separately! LONGO LPC-2 complies to the following standards: EMC: EN 61000-6-3:2007 + A1:2011, EN 61000-6-1:2007, EN 610003-2:2006 + A1:2009 + A2: 2009, EN 61000-3-3:2013 LVD: IEC 61010-1:2010 (3rd Ed.), IEC 61010-2-201:2013 (1st Ed.) Smarteh d.o.o. operates a policy of continuous development. Therefore we reserve the right to make changes and improvements to any of the products described in this manual without any prior notice. MANUFACTURER: SMARTEH d.o.o. Poljubinj 114 5220 Tolmin Slovenia ii

1 DESCRIPTION...1 2 FEATURES...2 3 OPERATION...3 3.1 Parameters...3 4 INSTALLATION...4 4.1 4.2 4.3 4.4 Connection scheme...4 Mounting frame selection...6 Mounting instructions...7 Module labeling...8 5 TECHNICAL SPECIFICATIONS...9 6 CHANGES...10 7 NOTES...11 iii

1 DESCRIPTION LPC-2.CH1M RFID reader is intended to be used as presence registering device and key-card holder. Module also provides push buttons (PB) for activating requested messages. This messages are convenient to notify personnel (e.g. occupied, do not disturb). Once a person has entered to the room, the key-card should be inserted to the CH1M card slot 1. If card ID for correspondent room is valid, several actions can be started (e.g. room light and air conditioning switched on). CH1M module features two PB with which customer is able to activate notification to the personnel. One PB activates DO NOT DISTURB message and the other PB activates ROOM SERVICE request. LPC-2.CH1M module can be modified on customer request: custom front label, push buttons changed, LEDs added, housing color. Please contact manufacturer for more information. LPC-2.CH1M reads unique ID (UID) from standard ISO/IEC 14443 A/MIFARE. 1 To achieve most reliable RFID card reading results use Smarteh RFID Mifare cards. RFID Mifare card must be inserted at least 40 mm deep into LPC-2.CH1M card slot in a time period between 1.. 3 seconds. 1

2 FEATURES Figure 1: LPC-2.CH1M. Table 1: Features RFID reader RFID card slot Adjustable LED intensity LEDs for showing activated messages & requests: do not disturb, room service 2 push buttons for activating messages & requests: do not disturb, room service OK LED FAULT X LED Power LED Internal fault LED Internal built-in buzzer 2

3 OPERATION Operation of the CH1M module is also dependent on parameters received on RS-485 communication channel. If RFID card is inserted into slot, reader tries to resolve RFID tag code. If code is read successfully, module activates status iidnew and sends RFID code in iidw1-iidw7 status fields. Code is send out until key-card is removed from slot. While iidnew status is active and ook or ofault is activated, corresponding LED is turned on. (LED3 OK or LED4 fault respectively). This state is sustained until key-card is removed. Each press on a PB1 or PB2 toggles status idndist or irserv respectively. By activating commands ookld, ofaultld odndist, orserv corresponding LED is turned-on (LED3, LED4, LED1, LED2). CH1M module LED's intensity can be adjusted from main module application also. By default their intensity is set to 75%. While oenints status is active, LED's intensity can be adjusted by changing oldints parameter. 3.1 Parameters If parameter is set to logical 1, is considered to be active, enabled or set. If parameter has logical value 0 is considered to be inactive, disabled, or cleared. Parameter can be status or command. Parameter as status means that CH1M module is sending information to main module. On the other hand, command represents request from main module to module. icomm: Normal state is 0. If set, there is communication error or no communication established. iidnew: When new RFID tag is recognized while inserted into CH1M slot, this status is set active till RFID card is not removed from the CH1M slot. idndist: Active status denotes user has requested do not disturb message to be displayed - LED1 irserv: Active status denotes user has requested room service message to be displayed - LED2 obuzz: While this command is active, buzzer is active. ook: Command for authorization of RFID code. ofault: Command for rejecting authorization of RFID code. odndist: Command for activation of do not disturb message, do not disturb LED1 is toggled orserv: Command for activation of room service request, room service request LED2 is toggled ookld: While this command is active, OK LED4 is set. ofaultld: While this command is active, fault LED3 is set. oenints: Enables changing LED's intensity together with oldints value. oldints: Command for setting LED intensity. Only valid while oenints active. iidw1: Upper (most significant) third of RFID code (UID0, UID1) iidw2: Middle third of RFID code (UID2, UID3) iidw3: Middle third of RFID code (UID4, UID5) iidw4: Lower (least significant) third of RFID code (UID6, UID7) 3

4 INSTALLATION 4.1 Connection scheme Figure 2: Connection scheme 4

Table 2: K1 K1.1 GND Ground K1.2 10.. 24 V DC Power supply input K1.3 RS-485 A Data receive/send line A K1.4 RS-485 B Data receive/send line B Table 3: LEDs & Buttons LED1: blue do not disturb On: request active Off: no request LED2: blue room service On: request active Off: no request LED3: red FAULT X On: RFID key standard NOK or ID card number wrong Off: No tag in proximity LED4: green OK On: RFID key standard OK and ID card number valid Off: No tag in proximity LED5: red Communication On: RS-485 communication fault Off: RS-485 communication OK LED6: green Power supply On: power supply OK Off: power supply missing or power off PB1 do not disturb each press toggles request on/off PB2 room service each press toggles request on/off Table 4: S1 RS-485 ADDRESS Switch 1 Switch 2 0 OFF OFF 1 OFF ON 2 ON OFF 3 ON ON 5

4.2 Mounting frame selection Frame, suitable for CH1M module insertion, should be modular one at least 3 gang wide. Be careful to have corresponding flush-mounting box provided on the place where module will be positioned. Smarteh has verified following lines to be compatible with LPC-2.CH1M module: Bticino Living, Light Gewiss Playbus, System Vimar Plana, Idea Tem Modul Soft, Modul Line Master Frames of other vendors most probably suits as well, but they were not verified by Smarteh. Before installation verify compatibility of non listed frames. Module housing has a fin on each side, which can be easily removed with knife cutter or pliers. This adaptation enables housing to be build in various frame formats with two different depths. With regard to frame used you may remove fin for housing to fit in. RFID module should not be positioned close to conductive areas (e.g.: metal frames and metal cover plate). Figure 3: Module with removable fin. 6

4.3 Mounting instructions Figure 4: Housing dimensions Dimensions in millimeters. All connections, module attachments and assembling must be done while module is not connected to the main power supply. Module should not be mounted outdoors. Several RFID panels should not be mounted close to each other. Minimum distance to next panel is at least 30 cm. This restriction also applies in case of mounting panels on both sides of the same wall. Adequate shielding material and provisions could be used to avoid interference between panels. RFID panel should not be positioned close to conductive areas (e.g.: metal frames and metal cover plate). Mounting instructions: 1. Set the correct RS-485 address (S1 switch) for LPC-2.CH1M (refer to the Table 4). 2. Connect interconnection cable to the connector K1. Max. allowed tractive force is 30 N. 3. Put the LPC-2.CH1M in mounting frames. 4. Cover LPC-2.CH1M with cover plate. LPC-2.CH1M connects to the main module on its RS-485 port using interconnection cable. When more special modules (e.g. LPC-2.CR1, LPC-2.CH1, LPC-2.DP1) are connected to main module, splitter is also required (e.g. SPL-2). NOTE: Signal wires must be installed separately from power and high voltage wires in accordance with general industry electrical installation standard. 7

4.4 Module labeling Table 5: Labels Label 1 (sample): Label 2 (sample): LPC-2.CH1M P/N:225CH1130V02002 D/C: 01/10 S/N: CH1-S9-1000000003 Label description: LPC-2.CH1M is the full product name P/N: 225CH113V02002 is the part number 225 general code for LPC-2 product family, CH1M short product name, 10 year of code opening V - denotes flush frame mounting module 01 derivation code 001 version code (reserved for future HW and/or SW firmware upgrades). D/C: 10/10 is the date code. 01 week and 10 year of production S/N: CH1-S9-1000000003 is the serial number. CH1 short product name, S9 user code (test procedure, e.g. Smarteh person xxx), 10 year (last two cyphers) 00000003 current stack number; previous module would have the stack number 00000002 and the next one 00000004. 8

5 TECHNICAL SPECIFICATIONS Table 6: Technical specifications 2 Power supply from main module Interconnection connector type RJ-12 6/6 Power consumption 1W RFID type ISO/IEC 14443 A/MIFARE2 Max. reading distance RFID card must be inserted into LPC-2.CH1M2 Dimensions (W x H x D) 75 x 49 x 29 mm Weight 40 g Ambient temperature 0 to 50 C Ambient humidity max. 95 %, no condensation Maximum altitude 2000 m Mounting position horizontal Transport and storage temperature -20 to 60 C Protection class IP 20 To achieve most reliable RFID card reading results use Smarteh RFID Mifare cards. RFID Mifare card must be inserted at least 40 mm deep into LPC-2.CH1M card slot in a time period between 1.. 3 seconds. 9

6 CHANGES The following table describes all the changes to the document. Date V. Description 30.05.17 3 Technical data update. 23.12.15 2 Pictures update. 01.06.14 1 The initial version, issued as LPC-2.CH1M module UserManual. 10

7 NOTES 11