icp installation guide

Similar documents
OMNI-4000 hardware installation manual

ECC-2 user manual and installation guide

Warning Before Installation. Package Contents EN - 1. Refer to your user's manual for the operating temperature.

Chore-Tronics Mobile Server

Warning Before Installation

VSD-1MC MANUAL 0-10V / 4-20mA Variable Speed Module with Manual Override

NT1-220 Rack. Installation Instructions. Specifications. Contents of Shipping Box. Important Safety Instructions. NT1-220 Rack

IRB-RET O P E R A T I N G I N S T R U C T I O N S UNIVERSAL SAFETY RETROREFLECTIVE PHOTOEYE U L MONITORED DEVICE

RTD SAMPLER OPERATOR S MANUAL

Secured Series: Hub Plus Kit Single Door Controller Package Installation Manual

IRB-RET O P E R A T I N G I N S T R U C T I O N S UNIVERSAL SAFETY RETROREFLECTIVE PHOTOEYE U L M O N I T O R E D DEVICE

Quick Installation Guide

IRB-MON O P E R A T I N G I N S T R U C T I O N S UNIVERSAL SAFETY PHOTOEYE U L M O N I T O R E D DEVICE

Debitek Card Revalue Station Installation Manual

CC186 AND CC186/2 STAND-ALONE OR SYSTEM CLOCK

OMNI Select troubleshooting guide

EDG Port Industrial 10/100 Mbps Ethernet Switch. User Manual

NT1B-300 Rack Installation Instructions

HDMI Extender over Cat5e/6

CMSA-100 Manual. Cinema Media Server Automation

Sonic Ruptor 400. User Manual

PMDX-105. I/O Option Riser Board User s Manual. Document Revision: 1.1 Date: 7 September 2004 PCB Revision: PCB-443A

MT8050iE series. Installation Instruction (1) (2)

IRB-MON UNIVERSAL SAFETY PHOTOEYE OPERATING UL MONITORED DEVICE

The power behind competitiveness. Delta Infrasuite Power Management. Power Distribution Unit. User Manual.

Eco Sensors OZONE CONTROLLER Model OS-6 Instructions for Use. General and New Features

FE8171V. 3MP 360 Panoramic View Vandal-proof

Eco Sensors OZONE CONTROLLER Model OS-6 Instructions for Use. General and New Features

ES-600 Ozone Controller Operation Manual

BTU-4D/BTU-4D-I Digital Temperature Unit & Sensors. Installation and Operation Manual

CA-A480-A Elevator Controller. Reference & Installation Manual

Warning Before Installation. Package Contents EN - 1. Refer to your user s manual for the operating temperature.

Kramer Electronics, Ltd. USER MANUAL. Model: WP-210E. XGA Line Driver

Enclosure TS-530 User Manual

ControlKeeper 4. General Information. Connecting Relay Loads. Installation Sheet. Getting Started. Power Supply Wiring. Mounting the Cabinet

CubePro. Main PCB Replacement Guide. Prosumer 3D Printer. Original Instructions

PMDX-108-Output. 8-Channel Isolated Output Board for PC parallel port pins 2-9. User s Manual

AE21 SERIES DISPLAY CONTROL TERMINAL

Instruction Sheet ICLS-COOL TM. Quiet-Cool Series Closet Cooler ICLS-COOL1 ICLS-COOL2

Owner s Manual. TSD-DCPDV DC Power Distribution with Fixed & Variable Outputs. TSD-DCPDV DC Power Distribution. AtlasSound.com

Installation Guide V290 (Color) This guide provides basic information for Unitronics LCD color touchscreen models V C30B and V T40B.

WARRANTY & LIMITATION OF LIABILITY

USB 2.0 CAT5E/6/7 EXTENDER

AEXX-349 SERIES REMOTE DISPLAYS

WARRANTY & LIMITATION OF LIABILITY

Quad-Relay Delay Switch (QRDS) User Manual (v1.0)

DP-222Q Color Video Door Phone Manual

ADSL Central Splitter Quick Setup Guide

SVP110 SURGE VOLTAGE PROTECTOR INSTRUCTION MANUAL

USB 2.0 Ranger Port USB m CAT 5e/6/7 Extender System. User Guide

This guide provides basic information for Unitronics Models 230/260/280/290 (Non-color Screens).

OPLC Installation Guide

AEXX SERIES MULTI-FUNCTION CLOCK/TIMERS

Instruction Manual. Balanced Audio Upgrade Installation. iport IW-21/IW-22 Upgrade Kits. Balanced Audio Upgrade Kit. (iport IW-21)

Owner s Manual. TSD-DCPDV DC Power Distribution with Fixed & Variable Outputs. TSD-DCPDV DC Power Distribution. AtlasIED.com

MTX-A Temperature Gauge User Manual

E2KQ-X. Fluororesin-coated Capacitive Sensor with Sensitivity Adjuster. Chemical-resistant Proximity Sensor. Ordering Information

MC 11 EB-2 Power supply cabinet with external bus, AC version

BTU 4 & Sensors. Installation and Operation Manual

Contents 1. Introduction Hardware Operation Software Operation Technical Data 5. IAdea Limited Warranty 6

DP-234Q (NTSC) DP-734Q (PAL) Hands-Free Video Door Phone Manual

Vision OPLC V TR6/V350-J-TR6

DP2 DOOR PHONE. For Technical Assistance Please Phone: (07)

VIP-804 QUAD ENHANCED NETWORK AUDIO PORT

IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS

User Manual CV-87K. PS/2 extender over cat.x. rev: Made in Taiwan

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

DP-222Q Color Video Door Phone Manual

Kramer Electronics, Ltd. USER MANUAL. Model: VP-200XLN. XGA Line Amplifier / DA

Canopy Surge Suppressor

INTELLIGENT DOCKING STATION USERS MANUAL

Chapter 1 : FCC Radiation Norm...3. Chapter 2 : Package Contents...4. Chapter 3 : System Requirements...5. Chapter 4 : Hardware Description...

AC4G-D User s Manual

Icron USB Raven Port USB 3.1, 100m CAT 6a/7 Point-to-Point Extender System User Guide

Installing the Camera

INSTRUCTION MANUAL DIGI-LOCK. Keyless Entry System. Installation. Programming. Troubleshooting. BASE Industries

VIP-480AL IP One-Way Horn

Digital Overhead Stirrer

PRO REMOTE 25 LV CAPACITANCE PROBE

IMS-9000 Intelligent Modem Switch USER S MANUAL. Document Part #: RDC-HDWIMS9K100

OZONE SWITCH Model OS-6. OS-6 Features

MAXIMA + Series ROTARY LEVEL CONTROL

User Guide. Control Box. RoscoLED TM.

SVP48 SURGE VOLTAGE PROTECTOR INSTRUCTION MANUAL

232iLM Keypad Installation and Programming Instructions

ARIENSE SENSE YOUR WORLD. 3-Axis Force Sensor FSE103. User Guide. Version 2.1. July VARIENSE INC.

VIP-148AL IP Talkback Horn

4300 WINDFERN RD #100 - HOUSTON TX VOICE (713) FAX (713) web: IMPORTANT!!!

PMDX-103. Parallel Port Isolator Board. User s Manual. Document Revision: 1.2 Date: 20 February 2007 PCB Revision: PCB-447B

SP x4 DVI over Single CAT5 Distribution Amplifier. User Manual. Made in Taiwan

SD1306. Speed Dome IP Camera. Quick User Guide

user s manual Battery case model #: IPB3500S Battery Case Charger for iphone 6

USB 2.0 Ranger Port USB m Cat 5e Extender System. User Guide

Kramer Electronics, Ltd. USER MANUAL. Rack Adapter Model: RK-1

4300 WINDFERN RD #100 HOUSTON TX VOICE (713) FAX (713) web: IMPORTANT!!!

MAXIMA+ Series Rotary Level Indicator

Operation Manual MODEL 2TX. 2-wire Isolated ph/orp Transmitter

Active UTP Transceiver Hub with Integral Isolated Camera Power

OPERATIONS MANUAL PCM-I/O48

PMDX-170 Slotted Optical Sensor

Transcription:

The Information Control Point (icp) is the latest SmartFarm Technology by Inc. The icp is the ultimate on-farm data-management tool. The icp has all the power of a basic personal computer, but instead of using a standard monitor, keyboard, and mouse to interact with it, the icp can be accessed remotely over a phone line or through wireless transfer. The icp s no-direct-interface design makes it ideal for applications where direct human interaction is not necessary or desired. The icp is adaptable. If you decide you require a keyboard, mouse, and monitor, you can easily connect them. icp features No-direct-interface design ideal for applications where no direct human interaction is desired Available keyboard, mouse, and monitor connections Automatic power-failure and auto-reset response Built-in RS-232/485 communication converter 56K voice/fax/data modem for optional remote access and management Network interface connector (10/100 Ethernet) for optional wireless access and management Status LEDs Rugged enclosure (non-vented, corrosion resistant, water resistant, and fire retardant) Windows XP Home Symantec pcanywhere 11.0 host Ratings The required power supply is the AC Transformer (ACT). One ACT can provide power for one icp. For more information, see the ACT installation guide or contact your dealer. Input power: Alarm relay: 24 VAC 0.2 A at 250 VAC, 0.4 A at 24 VAC, 2.0 A at 30 VDC 300450 rev 2 1

icp layout A J5 E H F I G C D J 1 A B C D E COM AC 24V CC CA OA ALARM COM colors E - green D - white/orange C - orange B - white/blue A - blue 1 - white/green M ASSY: 300050 S/N: YYYYMMDD-NNN WO# NNNNN S H 1 2 N K L 2 2006-09-29

A B C D E F G H I J K L M N Auto-reset jumper if you want to use the auto-reset feature, place the shunt on both pins. By default the shunt is on one pin and auto-reset is not enabled. Communication socket connect the communication wiring to this socket. See also K. Incoming power terminal connect the incoming power from the ACT to this terminal. See also K. Alarm relay terminal connect an external alarm system or alarm siren to this terminal. This is optional. See also K. PS/2 mouse port if you will be using a mouse or other pointing device, connect it to this port. PS/2 keyboard port if you will be using a keyboard, connect it to this port. Video port if you will be using a monitor, connect it to this port. Network interface (10/100 Ethernet) port if you will be using a router (wireless or other), connect it to this port. See also L. USB ports if you will be using a USB mouse or USB keyboard, connect it to one of these ports. Modem port if you will be using a remote phone line connection, connect the phone line to this port. See also L. Electrical knockouts use the strain reliefs provided to bring the communication, incoming power, and alarm wiring though these holes. Electrical knockouts if you are connecting a router or phone line, use the strain reliefs provided to bring the wiring though these holes. Cover plate if you are connecting a keyboard, mouse, and/or monitor, remove this plate and install the accessory plates. Serial number label if you need to contact Customer Support or require warranty service, you will need to provide this number. What you need to know before installing your icp The following items are included with the icp: Four strain reliefs Four mounting screws In addition to the items included with the icp, you need the following items: AC Transformer (ACT) Enough power cable to go from the incoming power supply (ACT) to the icp Unshielded twisted pair (UTP) communication cable, category 3 or category 5 for connecting devices (scale heads, controls, and so on) 300450 rev 2 3

Understanding power surges and surge suppression Power surges can be caused by external influences (outside the barn for example, lightning or utility distribution problems) or they can be caused internally (inside the barn for example, starting and stopping inductive loads such as motors). One of the most common causes of power surges is lightning. When lightning strikes the ground, it produces an enormously powerful electromagnetic field. This field affects nearby power lines, which transmit a surge to any device connected to it, such as lights, computers, or environmental controls like your icp. Lightning does not have to actually strike a power line to transmit a surge. Surge suppression devices offer some protection from power surges. Because it is not possible to internally protect this product completely from the effects of power surges and other transients, highly recommend that you install external surge suppression devices. For specific recommendations, see your electrical contractor. If you do not take these precautions, you acknowledge your willingness to accept the risk of loss or injury. If you do not install external surge suppression devices, you risk damage to the electronics inside your icp, which may cause your icp to fail. Because it is not possible to completely protect this product internally from the effects of power surges and other transients, we highly recommend that you install external surge suppression devices. For specific recommendations, see your electrical contractor. If you do not take these precautions, you acknowledge your willingness to accept the risk of loss or injury. Routing data wires Routing data wires in the same conduit as, or beside AC power cables, can cause electrical interference, erratic readings, and/or improper control. Data wires include all of the following: Temperature probe and humidity sensor cables Actuator feedback (potentiometer) wires Data communication wires, including RS-232/RS-485 Any cable or wire that does not provide AC power 4 2006-09-29

Guidelines for routing data wires Do not run the wires in the same conduit as AC power cables. Do not run the wires beside AC power cables or near electrical equipment. When crossing other cables or power lines, cross them at a 90-degree angle. If in doubt, do not run any wire or cable that is not an AC-power wire inside the same conduit or beside other AC-power wires. Mounting the icp When selecting a mounting location, follow the guidelines below. Select a location that is indoors and away from sources of moisture and heat. Do not mount the icp in a room or hallway containing animals. An office is an ideal location. Mount the icp on a solid, vertical surface with the electrical knockouts facing down. Mount the enclosure on a sheltered, vertical surface, with the electrical knockouts facing down. Use a screwdriver to tighten the screws in the enclosure. Do not use a drill or over tighten the screws; this can crack the enclosure and ruin the watertight seal. Use the electrical knockouts for bringing wires or cables into or out of the enclosure. Use watertight strain reliefs or conduit connectors at all cable-entry points. Do not make additional holes in the enclosure; this can damage the watertight seal or control components and void the warranty. Failure to follow the mounting guidelines will void the warranty. To mount the icp 1. Select a location. Make sure you have enough cable and wire to reach all the peripheral devices (router, keyboard, mouse, and so on if applicable). 2. Remove the screws from the front cover and then swing it open. 3. Mount the enclosure to a wall using the four screws provided with the control. Insert the screws into the large holes in each corner of the box and then tighten. 300450 rev 2 5

Connecting peripheral devices If you do not want to use remote (phone line) or wireless access as your only method of controlling the icp, you can connect a keyboard, mouse, and monitor. If you are connecting a keyboard, mouse, and/or monitor, you must remove the cover plate and route the cables through the accessory plates and gaskets. The order of the brackets and gaskets, as well as the suggested cable locations, is shown below. Insert the cables through the brackets and gaskets as shown below. Refer to the diagram on page 2 for the location of the modem port. enclosure inner gasket inner gasket outer gasket enclosure inner plate outer plate x12 inner plate narrowest slot outer gasket PS-2 mouse PS-2/USB keyboard, USB mouse monitor smallest hole outer plate narrowest slot USB keyboard or mouse network NOTE Use all the screws and nuts to fasten the brackets and gaskets to the enclosure. Cover any unused cable holes using electrical tape. Place the tape on the inside plate on the side that touches the outer gasket. 6 2006-09-29

Connecting a phone line If you want to use remote communications and pcanywhere over the phone line, you need to connect a phone line to the modem. Insert the phone cable through the strain relief noted in the diagram on page 2. Connect the phone line as shown below. Refer to the diagram on page 2 for the exact location of the modem port. Phone jack Connecting a router If you want to use wireless or network communications, you need to connect a router to the network interface port. Insert the network cable through the strain relief noted in the diagram on page 2 or through the accessory bracket shown on page 6. Connect the router as shown below. Refer to the diagram on page 2 for the exact location of the network interface port. NOTE Follow the router manufacturer s guidelines when installing the router. 300450 rev 2 7

Connecting the communications A communication channel is a continuous line of cable connecting all the devices on the channel. All the devices must be connected in series. uses two types of communication systems: Single-channel systems Multi-channel systems Single-channel systems All systems, except OMNI-4000 use single-channel communications. You can connect up to 32 devices in series on a single-channel system. Single-channel systems connect together as shown below. icp First device Second device Last device 1 A B C D E COM Multi-channel systems The multi-channel OMNI-4000 system requires an OMNI Server. An OMNI Server has 8 communication channels and can communicate with up to 32 devices on each channel, for a total of 256 devices. The OMNI-4000 system connects together as shown below. Channel 1 First device Channel 1 Second device Channel 1 Last device icp OMNI-Server Channel 2 Channel 2 First device Second device Channel 2 Last device 1 A B C D E COM Channel 3 First device Channel 3 Second device Channel 3 Last device 8 2006-09-29

Connecting the devices to the communication channel There are two steps to connecting the devices to the communication channel: 1. Connecting the communication wiring 2. Connecting the common reference wiring NOTE If you are using an OMNI-4000 system and OMNI Alarm Manager, see the OMNI Alarm Manager installation guide for additional installation information before connecting the communication wiring. Connecting the communication wiring Read Connector alignment below and Common mistakes in communication wiring on page 10 before connecting the communication wiring. For more information, see the installation guide for your controls. Connector alignment There are three possible connector types on devices. The four-positions, A B C D, are common to all models. Some models have five positions and include E for common reference wiring. The six-position connectors that include position 1 are included on the RS-485A and OMNI Alarm Manager (OAM) only. The proper connector alignment is shown below. Six-pin connector Five-pin connector Four-pin connector Alarm loop Communications Common reference Using consistent wiring helps eliminate communication connection errors and makes troubleshooting much easier. Use the following wire colors when connecting all devices to the communication system. 300450 rev 2 9

Wire function icp wire colors First device All remaining devices 1 alarm signal 1 white/green 1 white/green 1 white/green A communication A blue A blue A blue B communication B white/blue B white/blue B white/blue C communication C orange C orange C orange D communication D white/orange D white/orange D white/orange E common reference E green E green E green For OMNI systems with an OMNI Alarm Manager only Not available on all models See Common mistakes in communication wiring below. Common mistakes in communication wiring The following is a list of the most common communication wiring mistakes: Not using the correct type of communication cable the communication cable must be unshielded twisted pair cable (UTP), category 3 or category 5. does not recommend other types of wire. Not continuing the communication wiring properly all the devices on the communication channel must be connected in series and the wire must be continued properly from one device to the next. When continuing the communication wiring from one device to the next, the wires must be connected as shown below. correct A wire goes into each position on the connector and then goes out to the next device incorrect Do not use branches or T-connections. Not terminating the last device on the communication channel on all systems, the last device on the communication channel must have the termination resistors in place or a termination module installed. The termination resistors are located on the circuit board of all networkable devices, except the Supra (the Supra uses a Termination Module). You must remove the termination resistors from all devices, except the last one on the communication channel. 10 2006-09-29

The termination resistors on OMNI Power Blocks are in sockets on the Micro Board and can be removed and replaced if necessary. Termination resistors on all other models must be removed using wire cutters. For more information about the location of termination resistors, see the installation guide for your specific product. If you remove the termination resistors from the last device by mistake, you will have to install a Termination Module on that device. The Termination Module connects to the communication socket on the last device. For information about Termination Modules, contact your dealer or Customer Support. Running the communication cable in the same conduit as, or beside AC power cables routing communication cable in the same conduit as, or beside AC power cables, can cause electrical interference and communication failures. Follow the guidelines below when routing communication cable. Do not run the cable in the same conduit as AC power cables. Do not run the cable beside AC power cables or near electrical equipment. When crossing other cables or power lines, cross them at a 90-degree angle. To connect the communication wiring 1. Connect all the devices in series. For example, A on the icp to A on the first device, to A on the second device, and so on. Use the wires specified on page 9. 2. Remove the termination resistors from each device, except for the last one on the communication channel. The last device must have the termination resistors in place. For the location of the termination resistors, see the installation guide for that specific product. Connecting the common reference wiring The E position on the communication connector is used for common reference wiring. The common reference wire helps eliminate communication problems. Instead of using separate cable for the common reference wiring, we recommend using the green wire from the communication cable. Connect a wire from the E on the icp to E on the first device, to E on the second device, and so on. Use the wires specified on page 9. Follow the same guidelines for continuing the wiring properly as shown on page 10. 300450 rev 2 11

Using auto-reset and the alarm relay The icp alarm relay opens when there is a power failure. If the shunt is on both pins of jumper J5 (see item A in the diagram on page 2) the alarm relay also opens when there has been no serial communications for 12 hours. Serial communication is the method the icp uses to communicate with the devices. When the alarm relay opens, the icp power supply attempts to restart the icp. This is called the auto-reset feature. When the icp detects serial communications again, the alarm relay closes. The STS status LED on the side of the icp changes from green to red when there is an alarm condition. NOTE You do not need to connect the alarm relay to a siren or alarm system for the autoreset feature to function. If you want the auto-reset to restart the icp after there has been no serial communication for 12 hours, place the shunt on both pins of jumper J5 (see item A in the diagram on page 2). Connecting to a normally closed alarm system If you have an alarm siren or system that is normally a closed loop and opens on an alarm, connect the siren as shown below. For information about the type of alarm system you have: open on alarm or closed on alarm, see your alarm system s user manual. icp only icp and other devices icp other device icp CC CA OA ALARM CC CA OA ALARM CC CA OA ALARM 12 2006-09-29

Connecting to a normally open alarm system If you have an alarm siren or system that is normally an open loop and closes on an alarm, connect the siren as shown below. For information about the type of alarm system you have: open on alarm or closed on alarm, see your alarm system s user manual. icp only icp and other devices icp other device icp CC CA OA ALARM CC CA OA ALARM CC CA OA ALARM Connecting the incoming power The required power supply is the AC Transformer (ACT). One ACT can provide power for one icp. For more information, see the ACT installation guide. Connect the ACT as shown below. icp AC 24V AC 24V AC 24V 300450 rev 2 13

Limited warranty This warranty applies only to the Inc. () Information Control Point (icp). If you need warranty service, return the product and original proof of purchase to your dealer. warrants the icp subject to the following terms and conditions. This warranty is valid only to the original purchaser of the product, for 90 days from the manufacturing date. The manufacturing date is stated in the first eight digits of the serial number in the form year-month-day. hereby warrants that should this product fail because of improper workmanship, will repair the unit, effecting all necessary parts replacements without charge for either parts or labor. Conditions Installation must be done according to our enclosed installation instructions. The product must not have been previously altered, modified, or repaired by anyone other than. The product must not have been involved in an accident, misused, abused, or operated or installed contrary to the instructions in our user and/or installation manuals. 's opinion about these items is final. The person requesting warranty service must be the original purchaser of the unit, and provide proof of purchase upon request. All transportation charges for products submitted for warranty must be paid by the purchaser. Except to the extent prohibited by applicable law, no other warranties, whether expressed or implied, including warranties of merchantability and fitness for a particular purpose, shall apply to this product. Any implied warranties are excluded. is not liable for consequential damages caused by this product. does not assume or authorize any representatives, or other people, to assume any obligations or liabilities, other than those specifically stated in this warranty. reserves the right to improve or alter the icp without notice. Inc. 2 Terracon Place Winnipeg, Manitoba, Canada R2J 4G7 Phone: 204-233-1400 Fax: 204-233-3252 E-mail: support@phason.ca Web site: www.phason.ca 14 2006-09-29