designed for OMICRON Lab PML 111O High Impedance Passive Probe Instruction Manual

Similar documents
PML 791-RO Low-Z Passive Probe. Instruction Manual

PMT 201A-RO High Impedance Passive Probe. Instruction Manual

PMT 221A High Impedance Passive Probe. Instruction Manual

38 MHz Passive Voltage Probe R&S RT-ZP1X

TA MHz Oscilloscope Probe USER S GUIDE

TETRIS 2500 High Impedance Active Probe. Instruction Manual

TETRIS 1000 / High Impedance Active Probe Order-No: Features:

KHT 6000 C HV-Probe Calibrator. Instruction Manual

Instruction Manual LeCroy PP007-WR / PP007-WS Passive Probe

LeCroy PP009 Passive Probe Instruction Manual

LeCroy PP008 Passive Probe Instruction Manual

PP007-WR-1 PP007-WR-2 PP007-WS-1 PP007-WS-2. Operator s Manual. PP007 Passive Probe

N2870A Series Passive Probes and Accessories

N2870A Series Passive Probes and Accessories

Keysight N2870A Series Passive Probes and Accessories. Data Sheet

Instructions. P MHz 10X Passive Probe

Agilent 34401A 6½ 桁マルチメータ ユーザーガイド

P5200A Series High Voltage Differential Probes. Installation and Safety Instructions & Product Documentation CD

MTP INSTRUCTION MANUAL

User's Guide. Extech AM A AC Analog Clamp Meter

TT-SI 50 50MHz DIFFERENTIAL PROBE USER S MANUAL

Mini Digital Multimeter

TCP305A & TCP312A AC/DC Current Probes Instructions

custom test and measuring environments.

Model P4017 Single Channel USB Oscilloscope. Quick Start Guide

User's Guide. MiniTec TM Series Model MN25 MultiMeter

ENGLISH. User manual.

User s Guide. 600A True RMS AC/DC Clamp Meter. Model 38389

DM3058/DM3058E Digital Multimeter

DM-918 OPERATIONS MANUAL AUTORANGING MULTIMETER

User s Guide. RP7000S Series Single-Ended Active Probe. Nov RIGOL Technologies, Inc.

Mini Digital Multimeter

Mini Digital Multimeter

User s Guide. 600A AC Clamp Meter. Model 38387

User's Guide. Phase Sequence and Motor Rotation Tester Model

9040/9040UK. Users Manual. Phase Rotation Indicator

Instructions. P GHz 10X Active Probe

700 Series 200 Amp Clamp Meters

TVAC25100 TVAC25110 User manual

HV-CS kv Edge Mount Triaxial Jack

DC 100 A Current Probe

Mini Digital Multimeter Model MN15. User's Guide

CLAMP MULTIMETER METRACLIP 85 ENGLISH. Start Guide

User Guide True RMS Multimeter Extech EX205T

General Warranty. For more details, please refer to the user manual on the supplied CD, it can also be downloaded at

ELV12 Series. Instruction Manual

Part No. Z , IA Mar OPERATION MANUAL. High Voltage Digitalmeter A

Part No. Z , IA Jul OPERATION MANUAL. High Voltage Digitalmeter A

USER MANUAL. Mini Multimeter with Non-Contact Voltage Detector (NCV) Model EX310

Owner's Manual. True RMS Multimeter. Model No Safety Operation Maintenance Español

User s Manual Model PBL100 Logic Probe IM E. 4th Edition

Part No. Z , IA Nov OPERATION MANUAL. High Voltage Digitalmeter A

Model 8010 High Power Device Test Fixture Interconnection Reference Guide

PCT2000. User Manual. Precision current transducer 2000 A

2016 SIGLENT TECHNOLOGIES CO.,LTD

Automated Tuner System Power Distribution Hub

Autoranging Multimeter plus IR Thermometer Extech 450 Patented

374 FC/375 FC/376 FC. Clamp Meter. Safety Information

User's Guide. Digital Multimeter. Model MN42

Installation manual plugs and connectors with screw connection (16/32 A)

SLA Battery Capacity Analyzer

POCKET MULTIMETER 5115 ENGLISH User Manual

INSTRUCTION MANUAL. Model True RMS AC/DC 30A Mini Clamp-on Meter. Introduction. True RMS AC Current and Voltage

Safety and Radio-Frequency Interference

CVU-3K-KIT. 3 kv Bias Tee Kit. Description. Parts list / October 2014 *P * 1

AC/DC Current Probe Model SL201

Model 7701 Multiplexer Module

Model 4200-CVU-PWR. Parts Package. Introduction. PA-977 Rev. C / September 2016 *PPA-977C* 1

DS1000B Series Digital Oscilloscope

GPS Synchronization Module

50 Amp AC/DC Current Probe PA-655 INSTRUCTION MANUAL 安培交流 / 直流電流探測鉗. DC 500KHz. 5mA 50A.

Autoranging Mini Multimeter

BS 181 SINGLE CHANNEL POWER SUPPLY USER MANUAL

DC 100 A Current Probe

Operating instructions. Switching amplifier DN0210 DN / / 2015

1-36V, 0-3A DC Power Supply

CAEN. Electronic Instrumentation. NIM slot 5U CERN Compliant NIM Crate. Rev July Tools for Discovery

CVU-200-KIT. 200 V Bias Tee Kit. Description. Parts list / October 2014 *P A* 1

Contents. HP E1586A Rack Mount Terminal Panel User s Manual

2 in 1 LAN Tester and Multimeter Model:

Autoranging Mini Multimeter Model MN16A

ETHOS Auto Ranging Digital Multimeter

DVI Extender over Single CAT5 Mini SET

Model 8020-KHV. Kelvin Keithley Triaxial Connector Card. Description / October 2014 *P * 1

User's Guide. Model High Precision Quad Output DC Power Supply

User Manual. 400Amp AC Clamp Meter + NCV. Model MA430. Additional User Manual Translations available at

Keysight 42941A Impedance Probe Kit

CM-220 True RMS AC CLAMP METER INSTRUCTION MANUAL

ATK-2040 AC/DC TRMS Watt Clamp Meter Users Manual

Line Impedance Stabilization Network (LISN)

BENCH-TOP DIGITAL MULTIMETER INSTRUCTION MANUAL

PRODUCT SPECIFICATION. PC Board Relays. Series.

Agilent U2941A Parametric Test Fixture

Conductive Level Controller

S-14 S-14. Compact Digital Multimeter. Compact Digital Multimeter

Variable-Speed Vortex Mixer

Agilent 16442B. User s Guide. Agilent Technologies

HITACHI. EH-150 series PLC EH-RTD8 Resistance Temperature Detective input module Instruction manual. Safety precautions

1103 Power Supply (SN B and Above) Instruction Manual

General Warranty. For more details, please refer to the user manual on the supplied CD, it can also be downloaded at

Transcription:

designed for OMICRON Lab PML 111O High Impedance Passive Probe Instruction Manual

Copyright 2017 PMK GmbH All rights reserved. Information in this publication supersedes that in all previously published material. Specifications are subject to change without notice. Manufacturer PMK Mess- und Kommunikationstechnik GmbH Königsteiner Str. 98 65812 Bad Soden, Germany Internet: www.pmk.de Tel: +49 (0) 6196 5927-930 E-mail: sales@pmk.de Fax: +49 (0) 6196 5927-939 Warranty PMK GmbH warrants this measurement accessory for normal use and operation within specifications for a period of two (2) years from date of shipment and will repair or replace any defective product which was not damaged by negligence, misuse, improper installation, accident or unauthorized repair or modification by the buyer. This warranty is applicable only to defects due to material or workmanship. PMK GmbH disclaim any other implied warranties of merchantability or fitness for a particular purpose. PMK GmbH will not be liable for any indirect, special, incidental, or consequential damages (including damages for loss of profits, loss of business, loss of use or data, interruption of business and the like), even if PMK GmbH has been advised of the possibility of such damages arising from any defect or error in this manual or product. 2

Declaration of Conformity (EC conformity marking) The manufacturer declares the conformity of this product with the actual required safety standards in accordance with the Low Voltage Directive (LVD) 2006/95/EC: CEI/IEC 61010-031:2008 Safety requirements for electrical equipment for measurement, control and laboratory use - Part 031: Safety requirements for hand-held probe assemblies for electrical measurement and test WEEE/ RoHS Directives (EC conformity marking) This electronic product is classified within the WEEE/ RoHS* category list as monitoring and control equipment (category 9). Category 9 products are exempted from the restrictions under the scope of the RoHS directive. Your help and efforts are required to protect and keep clean our environment. Therefore return this electronic product at the end of its life either to the Service Department of PMK Mess- und Kommunikationstechnik GmbH or take care of separate WEEE collection and professional WEEE treatment yourself. Do not dispose as unsorted municipal waste. * EC Directives: WEEE Directive 2002/96/EC - Waste Electrical and Electronic Equipment RoHS Directive 2002/95/EC - Restriction of the use of certain Hazardous Substances in Electrical and Electronic Equipment 3

IEC Measurement Categories Definitions and Examples (Clause 6.5.2) Measurement Category I Definition: Measurement category I is for measurements performed on circuits not directly connected to a mains supply. Examples: Measurements in circuits not derived from a mains supply and specially protected (internal) circuits derived from a mains supply. In the latter case, transient stresses are variable; for that reason it is required that the transient withstand capability of the equipment is made known to the user. Measurement Category II Definition: Measurement category II is for measurements performed CAT II on circuits directly connected to the low voltage installation. Examples: Household appliances, portable tools and similar equipment. Measurement Category III Definition: Measurement category III is for measurements CAT III performed in the building installation. Examples: Measurements on distribution boards, circuit breakers, wiring including cables, bus-bars, junction boxes, switches, socket-outlets in the fixed installation and equipment for industrial use like for example stationary motors with permanent connection to the fixed installation. Measurement Category IV Definition: Measurement category IV is for measurements CAT IV performed at the source of the low-voltage installation. Examples: Electricity meters and measurements on primary over current protection devices and and ripple control units. IEC Pollution Degrees Definitions (Clause 3.5.6 ) Pollution Degree 1 No POLLUTION or only dry, non conductive POLLUTION. NOTE The POLLUTION has no influence. Pollution Degree 2 Only- non conductive POLLUTION. Occasionally, however, a temporary conductivity caused by condensation must be accepted. 4 Pollution Degree 3 Conductive POLLUTION occurs or dry, non-conductive POLLUTION occurs which becomes conductive due to condensation which is to be expected.

IEC Safety Symbols The following symbols may appear on the product or in this instruction manual: Caution, risk of danger. Refer to manual. Caution, risk of electric shock. Earth (ground) TERMINAL. Safety Information To avoid personal injury and to prevent fire or damage to this product or products connected to it, review and comply with the following safety precautions. Be aware that if you use this probe assembly in a manner not specified the protection this product provides may be impaired. Only qualified personnel should use this probe assembly. Use only grounded instruments. Do not connect the probe ground lead to a potential other than earth ground. Always make sure the probe and the measurement instrument are grounded properly. Connect and disconnect properly. Connect the probe output to the measurement instrument and connect the ground lead to earth ground before connecting the probe to the circuit under test. Disconnect the probe input and the probe ground lead from the circuit under test before disconnecting the probe from the measurement instrument. Observe probe and probe accessory ratings. Do not apply any electrical potential to the probe input which exceeds the maximum ratings of the probe or the accessories connected to it. In a combination always the lower rating / measurement category applies to both probe and accessories connected to it. Make sure to comply with the voltage versus frequency derating curve on page 8. Keep away from live circuits. Avoid open circuitry. Do not touch connections or components when power is present. Do not operate with suspected failures. Refer to qualified service personnel. Indoor use only. Do not operate in wet/damp environment. Keep product surfaces dry and clean. Do not operate the product in an explosive atmosphere. 5

Specifications Specifications that are not defined to be guaranteed are typical and are published as general information to the user. The instrument should have warmed-up for at least 20 minutes and the environmental conditions do not exceed the probe's specified limits. Electrical specifications Attenuation Ratio (1) 10:1 ± 2 % at DC Voltage Coefficient 0.00025 %/V at DC System Bandwidth 50 MHz (passband < -1dB) Probe Risetime 7 nsec (10 % - 90 %) Maximum Rated Input Voltage (2) Measurement category I: 400 V rms 1250 V transient overvoltage Measurement category II: 300 V rms CAT II Pollution Degree (2) 2 Voltage Derating Typical Voltage Derating PML 111O Note that the max. input voltage rating of the probe decreases as the frequency of the applied signal increases. 0 100k 1M 10M 100M Frequency [Hz] (1) Connected to grounded measurement equipment with an input impedance of 1 MΩ ± 1 %. (2) As defined in IEC 61010-031. See definitions explained on page 4 and 5. Amplitude AC rms [V] Sinus 400 300 200 100 Electrical Characteristics Input Resistance (System) 1 MΩ ± 1 % Input Capacitance (System) 12.5 pf Compensation Range 40 pf - 55 pf Input Coupling of the Measuring Instrument 1 MΩ AC / DC Input Impedance 10M 1M Typical Input Impedance PML 111O Note that the input impedance of the probe decreases as the frequency of the applied signal increases. Z [Ohm] 100k 10k 1k 100 6 10 10 100 1k 10k 100k 1M 10M 100M Frequency [Hz]

Specifications Mechanical Characteristics Weight (probe only) Cable Length Probe Tip Diameter 48 g 1.3 m 2.5 mm Environmental Specifications Altitude operating up to 2000 m non-operating up to 15000 m Temperature Range operating 0 C to +50 C non-operating -40 C to +71 C Maximum Relative Humidity operating 80 % relative humidity for temperatures up to +31 C, decreasing linearly to 40 % at +50 C Adjustment Procedures The probe can be adjusted for low frequency (LF) compensation and for high frequency (HF) compensation, as shown in the following two pictures. LF Compensation HF Compensation 7

Probe Accessories Accessory available from PMK GmbH: www.pmk.de 018-292-055 IC-Cap 2.5 0.5 mm pitch; green 018-292-056 IC-Cap 2.5 0.65 mm pitch; blue 018-292-058 IC-Cap 2.5 0.8 mm pitch; gray 018-292-060 IC-Cap 2.5 1.0 mm pitch; brown 018-292-061 IC-Cap 2.5 1.27 mm pitch; black 018-292-052 Insulating Cap 2.5 018-292-053 Protection Cap 2.5 Ø 0,8 [ 0.0315 ] Ø 0,85 [ 0.0335 ] 5,5 [ 0.2165 ] 3,89 [ 0.1531 ] R 0,75 [ 0.0295 ] 890-700-017 PCB Adapter 2.5 HQ 890-700-027 PCB Adapter 2.5 90 HQ 018-210-005 BNC Adapter 2.5 890-320-007 Sprung Hook 2.5 890-702-000 Adapter 2.5 to 2 mm Bananaplug 890-710-000 Adapter 2.5 to 4 mm Bananaplug 890-700-007 PCB Adapter Kit 2.5 890-710-700 Adapter 2.5 to 0.8 mm Socket 890-500-13X QFP IC-Clip 13 mm long down to 0.5 mm pitch ( X : 4 = yellow; 5 = green ) P25-2 / P25-0 Pico hook red /black 890-720-701 Dual Adapter 2.5 to 0.8 mm Sockets 890-500-00X QFP IC-Clip short down to 0.5 mm pitch ( X : 4 = yellow; 5 = green ) 8

Probe Accessories 018-292-007 Adjustment Tool T 890-010-912 Set Coding Rings 3x4 Colors 890-450-220 HF Compensated Ground Lead 22 cm 890-400-015 Ground Lead 15 cm 890-501-500 Set 5 Spring Tips gold-plated 0.5 mm 893-250-001 2 Footer Positioner 890-005-013 Set 5 solid Tips CuBe 0.5 mm 890-400-004 Ground Spring 2.5 890-400-104 Ground Lead 22 cm to 4 mm Bananaplug 890-100-150 10 self-adhesive Copper Pads ( 2 x 2 cm ) 018-291-101 Ground Blade 2.5 DEVICE UNDER TEST 890-400-701 Ground Lead 2.5 to Mini Alligator Clip 890-400-102 Ground Lead 22 cm to 2 mm Bananaplug 890-400-703 Ground Lead 2.5 to 0.8 mm Socket 890-400-011 Ground Lead 11 cm to Miniclip 890-400-013 Ground Lead 11 cm to 0.8 mm Socket 9

Scope of Delivery The following items are included in the scope of delivery. Please check the delivery for completeness. If any item is missing, send a message to our service department and we will send you this item immediately. Item Qty BNC Adapter 1 Coding Rings (set) 3x4 Colors 1 Ground Lead 15 cm 1 Ground Spring 2.5 1 Instruction Manual 1 Insulating Cap 2.5 1 PCB Adapter Kit 2.5 1 Probe 1 Protection Cap 2.5 1 (1) Solid Tip CuBe 0.5 mm 1 Spring Tip gold plated 0.5 mm 1 (2) Sprung Hook 2.5 1 (1) plugged on probe (2) installed in probe Use ground lead only for connections to earth ground. The BNC Adapter is rated: 42 V pk AC + DC The accessories provided with the probe have been safety tested. Do not use any other accessories than those originally provided. Handling Handle with care especially when fitted with the extra thin and sharp spring contact tip to avoid any injury. Note that the probe cable is a sensitive part of the probe. Do not damage through excessive bending or pulling. Avoid mechanical shock to this product in general to guarantee accurate performance and protection. 10 Maintenance Cleaning To clean the exterior of the probe use a soft cloth moistened with either distillated water or isopropyl alcohol. Before use allow the probe to dry completely.

Maintenance Changing the Probe Tip To change the probe tip use pliers to grip and pull it carefully straight out of its contact socket, along the axis of the probe. Do not grip the white plastic insulator or the housing with pliers, because the tip could be squeezed and cannot be removed and respectively the probe could be damaged. If the probe tip is removed, the new tip can be inserted with pliers into the contact socket, along the axis of the probe. In order to insert the probe tip completely into the housing, press the probe tip against a hard surface carefully. Use pliers to grip and pull the probe tip carefully out of its contact socket. Do not grip the white plastic insulator or the probe housing with pliers. About PML Probe Series The compact design with only 2.5 mm housing diameter at the probe tip is ideal for measurements of SMT components. It provides a much better visibility over of the DUT (device under test) as conventional 5 mm probe housing designs. A true PMK GmbH feature the exchangeable probe tip is also available for the PML series. The gold plated spring contact or the rigid tip are only 0.5 mm in diameter. The tip replacement is easy and gives the engineer the best choice. Particularly for HF measurements on IC s, a short as possible ground connection is recommendable. Due to long ground leads most conventional adaptations bring additional inductance and resonances into the measurement which will result in false or inaccurate readings. The innovative IC contacting system of the PML with 5 different IC adapters from 0.5 to 1.27 mm pitch in combination with the ground blade and IC ground copper pad is the ideal solution for short-circuit-safe, reproducible, and authentic measurements. These great advantages and over 30 accessories parts for the new PML probe series will offer various configuration to solve most adaptation desires. IC contacting system with IC adapter, ground blade and IC ground copper pad. Accessory shown in this picture could be obtained from PMK and is not in the scope of delivery. 11

12 M55-111-O00 Revision B - October 2017