RMCN22BD Analog Converter ma - for Zelio Analog

Similar documents
RE9RA21MW7 off-delay timing relay s V AC -

RM4TA32 three-phase network control relay RM4-T - range V

RM4TR31 three-phase network control relay RM4-T - range V

RE7YA12BU time delay relay for star-delta starter s - 24 V AC DC - 2OC

RM17TG. Main. Product or component type. Product specific application. Relay monitored parameters. Switching capacity in VA

RE8TA31BU industrial timing relay s - type A - 24 V AC/DC, V AC - 1 C/O

RE7RB13MW adjustable off-delay timing relay s V AC DC - 2OC

RM17TG. Main. Product or component type. Product specific application. Relay monitored parameters. Switching capacity in VA 250 V AC

TM3TI4 module TM3-4 inputs temperature

RE7RM11BU off-delay timing relay with control contact s - 24 V AC DC - 1OC

RE8YG31BUTQ industrial timing relay s - type Qc - 24 V AC/DC, V AC - 1C/O

RM4LA32M liquid level control relay RM4-L V AC

TM3DI16G module TM3-16 inputs spring

ABS2EC01EB input interface module mm - solid state - 24 V DC

RE22R1QMQ star-delta timing relay - 230VAC/440VAC - 1 C/ O

RE17LAMW on-delay timing relay - 1 s..100 h V AC/DC - solid state output

RE22R2QTMR Star-Delta Timing Relay s 300h V AC/DC - 2C/O

RE7YA12BU. Main. Contacts type and composition Component name Time delay type. 24 V AC/DC at 50/60 Hz V AC/DCat 50/60 Hz

RM4JA31M current measurement relay RM4-J - range ma V AC

RE22R2AMR On-delay Timing Relay s 300h V AC/DC - 2C/O

RM35TF. Main. Product or component type. Product specific application. Relay monitored parameters 250 V AC 5 A AC

RM22LA32MR Level control relay RM22-L V AC/DC - 2 C/O

RE11RAMU on-delay timing relay - 1 s..100 h V AC - 1 OC

RM35LM33MW liquid level control relay RM35-L V AC/DC

RE48ATM12MW on-delay timing relay s..300 h V AC - 2 OC

RM35LM33MW liquid level control relay RM35-L V AC/DC

OTB1S0DM9LP I/O distributed module OTB - Modbus non isolated serial link m

ABE7R16S210 sub-base - soldered electromechanical relays ABE7-16 channels - relay 10 mm

ABL1RPM24100 regulated SMPS - single phase V input - 24 V output W

TM5C12D6T6L compact I/O expansion block TM5-24 I/0-12 DI - 6 DO transistor - 4 AI - 2 AO

TM258LD42DT4L compact base M I/O - 24 V DC

ABL1REM24100 regulated SMPS - single phase V input - 24 V output W

OTB1E0DM9LP I/O distributed module OTB - Ethernet TCP/IP m

XMLK006B2C21 pressure sensor XMLK bar - G 1/4A mA - DIN - set of 1

SR2B121BD compact smart relay Zelio Logic - 12 I O - 24 V DC - clock - display

OTB1C0DM9LP I/O distributed module OTB - CANopen bus m

SR2B121B compact smart relay Zelio Logic - 12 I O - 24 V AC - clock - display

SR2B202BD compact smart relay Zelio Logic - 20 I O - 24 V DC - clock - display

ABL8BBU24200 battery control module V DC - 24 V - 20 A - for regulated SMPS

TM258LF42DT compact base M I/O - 24 V DC - CANopen

RM4JA01F current measurement relay RM4-J - range ma V AC

SR3B261FU modular smart relay Zelio Logic - 26 I O V AC - clock - display

SR3B261FU modular smart relay Zelio Logic - 26 I O V AC - clock - display

ATSU01N209LT soft starter for asynchronous motor - ATSU01-9 A V KW

RPM42P7 power plug-in relay - Zelio RPM - 4 C/O V AC - 15 A - with LED

ATS01N232RT soft starter for asynchronous motor - ATS01-32 A V

RM4JA32MW current measurement relay RM4-J - range A V AC DC

OTB1C0DM9LP. Main , length of segment <= 185 m , length of segment <= 160 m. 3.4 kohm for I8...I kohm I0...I1 5.7 kohm I6...

RM22TG. Product data sheet Characteristics. three-phase control relay Vac, 2 C/O. Main. Complementary. Network number of phases

OTB1E0DM9LP I/O distributed module OTB - Ethernet TCP/IP m

XB7EV07BP round pilot light Ø 22 - clear - integral LED - 24 V - screw clamp terminals

SR3XT43BD analogue I/O extension module - 4 I O - 24 V DC - for Zelio Logic

LMC058LF42 compact base - 42 I/O - 24 V DC supply

ABL1REM Main. Rated power in W. Power supply output current V. <= 100 Aat 230 V AC. 2.5 Aat 240 V

ATS01N103FT soft starter for asynchronous motor - ATS01-3 A V KW

RM4UA33M voltage measurement relay RM4-U - range V V AC

TM241CE24T controller M IO transistor PNP Ethernet

XMLP200PD730 pressure transmitter - XMLP - 200psi - 1/4"18NPT V - M12 - set 1

ABL4RSM24050 regulated SMPS - 1 or 2 phase V AC - 24 V - 5A

TM7BDM8B. Main. Enclosure material. Input/output number 8 Input/output number of splitter box

ATV12P037F1 variable speed drive ATV kW hp V - 1ph - on base plate

TWDLMDA40DUK extendable PLC base Twido 24 V - 24 I 24 V DC - 16 O solid state

TM3DI16 module TM3-16 inputs

TM3TM3 module TM3-2 temperature inputs and 1 analog output

RPM13F7 power plug-in relay - Zelio RPM - 1 C/O V AC - 15 A - with LED

RM35JA32MR Current control relay 0.15A 15A, 2 C/O

TM241CE40R controller M IO relay Ethernet

TM3TI4 module TM3-4 inputs temperature

TM221CE40T controller M IO transistor PNP Ethernet

TM7BDI16B. Main. Enclosure material. Input/output number 16 Input/output number of splitter box

TM3AI4 module TM3-4 analog inputs

TM221M16R controller M IO relay

RSB1A160JD interface plug-in relay - Zelio RSB - 1 C/O - 12 V DC - 16 A

SR2D101BD compact smart relay Zelio Logic - 10 I O - 24 V DC - no clock - no display

RXM4AB1BD miniature plug-in relay - Zelio RXM - 4 C/O - 24 V DC - 6 A

RE22R2KMR Off-delay Timing Relay s 10min V AC/DC - 2C/O

K1D011B body for BCD encoded output switch - 1 pole A - for Ø 22 mm

RM17UAS. Product datasheet Characteristics. voltage control relay RM17-U - range V DC. Main. Complementary. Price* : 70.

RE22R2QGMR Star-Delta Timing Relay s 300h V AC/DC - 2C/O

K1F006ALH cam switch - 6-pole A - screw mounting

ATV12H018M2 variable speed drive ATV kW hp V - 1ph

SR3B261BD modular smart relay Zelio Logic - 26 I O - 24 V DC - clock - display

TM3SAF. Main. Device short name

ZBRN1 access point- 2 RJ V AC/DC-4 displays-5 LEDs-Eth-Modbus-wireless radio

K1K015NZ4 cam stepping switch - 2-pole A - screw mounting

TM3TI8T module TM3-8 inputs temperature

SR2B121BD compact smart relay Zelio Logic - 12 I O - 24 V DC - clock - display

XMLR400M1P25 Pressure sensors XMLR 400bar - G 1/4-24VDC ma - PNP - M12

XGCS491B201 Standalone panel smart antenna

TWDLCDA16DRF compact PLC base Twido - 24 V DC supply - 9 I 24 V DC - 7 O relay

XXA18P1AM12 Ultrasonic sensor cyl. 90 deg M18 - Sn=1m - analog 4-20mA - SYNC - connector M12

RE22R2AMR On-delay Timing Relay s 300h V AC/DC - 2C/O

TM221CE24R controller M IO relay Ethernet

RE22R2CMR Off-delay Timing Relay s 300h V AC/DC - 2C/O

XCKJ10559H7 limit switch XCKJ - thermoplastic round rod lever 6 mm - 1NC+1NO - snap - 1/2NPT

TM221ME32TK controller M IO transistor PNP Ethernet

SR2A201BD. Main. <= 0.5 ma for IB...IG used as discrete input circuit. <= 5 Vfor IB...IG used as discrete input circuit V

RE8YG31BUTQ industrial timing relay s - type Qc - 24 V AC/DC, V AC - 1C/O

SR3XT101BD discrete I/O extension module - 10 I O - 24 V DC - for Zelio Logic

ATV12H075M3 variable speed drive ATV kW - 1hp V - 3ph - with heat sink

Transcription:

Characteristics Analog Converter - 4..20 ma - for Zelio Analog Main Commercial Status Range of product Product or component type Analogue input type Analogue output type Commercialised Zelio Analog Voltage/Current converter Voltage 0...10 V DC Current 4...20 ma Voltage 0...10 V >= 100 kohm by cabling Current 4...20 ma <= 500 Ohm by cabling Complementary Protection type Overvoltage protection on output (+/- 30 V) Reverse polarity protection on output Short-circuit protection on output Abnormal analogue output voltage Abnormal analogue output current [Us] rated supply voltage Current consumption Local signalling Measurement error < 0 V when no input wired or wire broken < 0.004 A when no input wired or wire broken 24 V DC +/- 20 %, non isolated <= 60 ma for current output <= 40 ma for voltage output LED green (power ON) Repeat accuracy +/- 0.6 % full scale at 60 C +/- 0.2 % full scale at 20 C Temperature coefficient Clamping connection capacity Tightening torque Marking +/- 10 % of full scale at 20 C (electromagnetic interference of 10 V/m) +/- 1 % of full scale at 20 C 200 ppm/ C 1 x 2.5 mm² 2 x 1.5 mm² 0.6...1.1 N.m Surge withstand 0.5 kv for 1.2/50 µs conforming to IEC 61000-4-5 [Ui] rated insulation voltage Fixing mode Product weight Environment CE 2 kv Clip-on, 35 mm symmetrical DIN rail By screws, mounting plate 0.12 kg Standards IEC 60584-1 IEC 60947-1 Product certifications IP degree of protection Fire resistance CSA GL UL IP50 housing IP20 terminal block 850 C conforming to UL 850 C conforming to IEC 60695-2-1 Shock resistance 50 gn for 11 ms conforming to IEC 60068-2-27 Vibration resistance 5 gn (f = 10...100 Hz) conforming to IEC 60068-2-6 Resistance to electrostatic discharge 8 kv (in air) conforming to IEC 61000-4-2 level 3 6 kv (in contact) conforming to IEC 61000-4-2 level 3 The information provided in this documentation contains general descriptions and/or technical characteristics of the performance of the products contained herein. This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications. It is the duty of any such user or integrator to perform the appropriate and complete risk analysis, evaluation and testing of the products with respect to the relevant specific application or use thereof. Neither Schneider Electric Industries SAS nor any of its affiliates or subsidiaries shall be responsible or liable for misuse of the information contained herein. Jun 23, 2014 1

Resistance to fast transients 2 kv on power supply conforming to IEC 61000-4-4 1 kv on input-output conforming to IEC 61000-4-4 Disturbance radiated/conducted CISPR 11 CISPR 22 group 1 - class B Ambient air temperature for storage -40...85 C Ambient air temperature for operation 0...60 C (2 cm spacing) 0...50 C (mounting side by side) Pollution degree 2 conforming to IEC 60664-1 2

Dimensions Drawings Analog Interface (Converter) Dimensions (1) Terminal block AB1TP435U or AB1RRNTP435U2 3

Mounting and Clearance Mounting Mounting on Rails AM1 Panel Mounting 4

Connections and Schema Analog Interface: Voltage/Current Converter Wiring Diagrams Current input signal Voltage input signal The input, output and power supply lines must be kept away from the power cables to avoid effects due to induced interference. The input and output cables must be shielded as indicated in the schemes and must be kept away from each other. 5