Multi-Point Gas Detection and Control System

Similar documents
Multi-Point Gas Detection and Control System

Multi-Point Gas Detection and Control System

Carbon Monoxide (CO) Gas Detection and Control System

Multi-Point Digital Gas Detection and Control System

Gas Controller System DGC-06

Sensor for car parks and tunnels

Iso DIN. User Manual. 1 channel Earth Fault Monitoring

CDD Carbon Dioxide Transmitter

MODEL CIO-EN MODBUS/TCP, MODBUS/RTU I/O MODULE

Trident and Trident X2 Digital Process and Temperature Panel Meter

12-36 VDC/12-24 VAC Power Option 4-Digit Display, 0.56 (14.2 mm) or 1.20 (30.5 mm)

PM174 PM174 IEEE1159 ADVANCED POWER QUALITY ANALYZER. Features

TPE 1464 Series Pressure Transducer

CDD4 Duct Carbon Dioxide Transmitter

Power Meter PowerMonitor 500

TABLE OF CONTENTS INTRODUCTION. 3. Analog Input Analog Output Digital Input Digital Output OPERATIONAL DESCRIPITON.. 7 PROGRAMMING AND INITIAL SETUP.

Output Signal Active Note DC V. Electrical Data Power Supply DC V, ±10%, 1.4 W

HIGH-VOLTAGE DC METER

MIC-2 MKII, Multi-instrument DATA SHEET

PLEASE READ INSTRUCTIONS CAREFULLY BEFORE INSTALLATION!

Operating instructions. Standstill monitor A / / 2011

PGR-3200 MANUAL INSULATION MONITOR

1/32-DIN TEMPERATURE CONTROLLER INSTALLATION, WIRING AND OPERATION MANUAL FORM 3882

High Voltage DC Meter

Temperature Controller E5C4

Suitable for a wide range of installations with wall-mount, flush-mount and hand-held remote control options.

Installation and User Guide

CurrentWatch Current Sensors. EGF Series Ground Fault Sensors. Ground Fault Sensors with Solid-State or Mechanical Relay Outputs.

CDD4 Series Room CO2 Transmitter Installation Instructions

Field selectable application type and room module series, via dip-switches on controller

MIC-2 MKII & MIC-2 MKII DIN, Multi-instrument DATA SHEET

A0-10 ANALOG OUTPUT. Instruction Manual April 2001 NALOG OUTPUT

ISOMETER isoev425 with coupling device AGH420

Energy Management Modular DC Energy analyzer Type VMU-E and VMU-X

DTM Distributed Transmitter Monitor

Communication Module BAC-06 for DGC-06 System

LAUREL ELECTRONICS, INC.

MIC-2 Multi-instrument DATA SHEET

Communication Module BAC-06 for DGC6 System

D7000 SERIES MODBUS TCP/IP ETHERNET INTERFACE MODULES

Andover ContinuumTM Infinet II

EMS467 Monitoring System. Installation and Operations Manual Section 40

TC Type Range Conformity Error. J -210 C to +760 C (-347 F to F) ±0.09 C (±0.16 F) K -244 C to C (-408 F to F) ±0.1 C (±0.

PTU300 Combined Pressure, Humidity and Temperature Transmitter

dual-line 6-dIGIt process MeteR

General information. Display. Supply voltage. Input current

The IQ300 wall mount load cell indicator is a precision digital indicator for load cell and strain gauge applications.

Dräger Polytron 8200 Stationary gas detector (CatEx)

Thermocouple Input Module Product Specifications and Installation Data

2 Table of Contents 1. TABLE OF CONTENTS. 1. Table of Contents Introduction Wiring Diagram Terminals Review...

UDC 1000 and UDC 1500 MICRO-PRO SERIES UNIVERSAL DIGITAL CONTROLLERS

General information. Display. Supply voltage. Input current. Encoder supply. Power losses

PGR-4300 MANUAL GENERATOR GROUND-FAULT RELAY

PanelView Plus/VersaView CE Terminals and Display Modules

LAUREL. Laureate RTD Temperature Panel Meter / Controller ELECTRONICS, INC. Features. Description. Specifications

ISOMETER isoev425/isoev425hc with coupling device AGH420

Signet Pressure Transmitter

EC07 EC63. Compatible actuators: ERL2 ESD2. How to order EC 07 B. Series. B Installation. method

BACnet/IP Web Interface

FX Input/Output (I/O) Modules XM07 and XM14

Functional data Communicative control Cloud: (call for clientapi ) Angle of rotation 90

General information. Supply voltage. Input current. Encoder supply. Power loss. Memory

For full product information, visit Use the SpeedSpec code or scan the QR Code for quick access to the specific web page.

General information. Display. Supply voltage. Input current. Encoder supply. Output current

DWYER INSTRUMENTS, INC. Series AVUL Air Velocity Transmitter. Specifications - Installation and Operating Instructions.

PGR-4700 MANUAL SENSITIVE GROUND-FAULT RELAY

INSTRUCTION MANUAL. Universal AC Input Switching Power Supply 24 Vdc Output DIN-Rail Models PSD1000, PSD1000F PSD PSD1000F

DMT345 and DMT346 Dewpoint Transmitters

PD765 TRIDENT. Trident Series Process & Temperature Meters.

SERIES CMT CARBON MONOXIDE GAS TRANSMITTER

BA/BS4S Temperature Sensor Installation & Operating Instructions

TAC I/NETTM 1284, 1280, Security Control Unit

TS InteliSwitch Digital Time Switch 24VDC/VAC

Energy Management Modular Universal Utility Meter and Power Analyzer Type WM24-96

Powermite 599 MT Series SAS Electronic Valve Actuator 24 Vac or 24 Vdc, Proportional Control

Process & Temperature Digital Panel Meter

MODEL: R1M-A1. PC Recorders R1M Series. SPECIFICATIONS OF OPTION: Q COATING (For the detail, refer to M-System's web site.)

MAXIOM. Data Sheet. Lighting Relay Panel. Overview Leverage the Power of BAS Integration

InteliLite MRS17 Click Here to Learn More

PD765 TRIDENT. Trident Series Process & Temperature Meters.

MOD-RI Room Interface Modules with Modbus

Zone Pressure Touch Sensor - Standard Range

Process displays For current and voltage

General information. Display. Supply voltage. Input current

MMT330 Series Moisture and Temperature Transmitters for Oil

INSTALLATION DKM-409 NETWORK ANALYSER WITH HARMONIC MEASUREMENT AND SCOPEMETER. Before installation:

F1000 User's Manual. (Version: V1.01)

Compact Coded Magnetic Safety Interlock Switch and Control Units

Measure & Control Temperature & CO2 levels with analog & digital I/O

TRACKER 220 SERIES. Digital Panel Indicators. A Complete Range of Universal Input Digital Panel Indicators for Temperature and Process Measurement

Data Sheet T 6493 EN. TROVIS 6400 Automation System TROVIS 6493 Compact Controller. For panel mounting (front frame 48 x 96 mm/1.89 x 3.

Level-Lance Model 5400A

The Tracker 220 Series A Complete Range of Universal Input Digital Panel Indicators for Temperature and Process Measurement

Functional data Nominal torque min. 180 in lb [20 NM] Communicative control Cloud: (call for clientapi )

Amplifiers, Counters, Timers & Controls

RXM39.1. PL-Link IO Block. Desigo TRA. Use with PXC3 series room automation station

DPST-NO None 2 channels Auto-reset Inverse (+/-) 24 VAC/VDC 4 G9SB-2002-A 1 channel or 2

Model OI x82 ProSafe

SED2 Variable Frequency Drives with Electronic (E) Bypass Options

MAKING MODERN LIVING POSSIBLE AK-255 CO 2. Controller On-Site Installation Guide DANFOSS ELECTRONIC CONTROLS & SENSORS

Transcription:

Multi-Point Gas Detection and Control System Specifications subject to change without notice. USA 40804 Page of 7 DESCRIPTION Wall mounted, microprocessor-based, multi-point, analog electronic control system for various gas, temperature and humidity detection, control and alarm. PolyGard APPLICATION To control and alarm upon the presence of any toxic, combustible and refrigerant gases. Any combination of the AT-/3300 series or other 4-20 ma transmitters can be connected to the control unit. The controller can interface via binary outputs, a signal, and/or an optional BACnet or Modbus port with any compatible electronic analog control, DDC/PLC control or automation system. FEATURES Continuous monitoring Twelve (2) analog inputs, Four (4) digital inputs Fifteen (5) relay outputs: - Five-stage control - Fail-safe assignable Six (6) analog outputs, - Selectable for low, high or averaging One () supply output Built-in horn Accepts combination of toxic or combustible gases, refrigerants, temperature or humidity sensor inputs Liquid Crystal Display (LCD) Optional BACnet or Modbus upwards communication to BAS LED status indicators Keypad user interface Simple menu-driven programming RFI/EMI protected Modular technology Overload & short-circuit protected Resettable breaker NEMA 4X enclosure Easy maintenance City of Los Angeles Approved NRTL Tested & Certified Conforms to STD UL 207 UL 2075 certified PolyGard Carbon Monoxide & Combustible Gas Transmitters are recommended for maximum system performance and reliability Upwards Options BACnet, Modbus SPECIFICATIONS Electric Power supply Power consumption RF/EMI protected Type of Control General Analog inputs Analog reading Stage level / setpoint - hysteresis/ switching differential 20 VAC (90...230 VAC), 50/60 Hz resettable breaker, 24 VAC on request 40 VA, max. 4.0 W @ 3 ft. ( m) radiated Five-stage (S to S5) control, assignable up to fifteen (5) binary/relay output, i.e. Low-med-high-fault/fail-horn*, or low-low2-med-med2-high, or any other combinations (* = horn/audible alarm built-in and factory pre-configured to relay output R5 ) Twelve (2) Current and mean (average) value Field adjustable over full range, five (5) per analog input, assignable to current or mean (average) value Selectable for each sensor point Digital inputs Four (4), each can be individually assigned to any relay (R...R5). - application Remote audio/visual alarm reset or override function Relay outputs (R-R5) w/ status LEDs Fifteen (5) SPDT, 8 A 24 VAC/VDC-250 VAC contact resistance 00 mω, max. - each stage level (S-S5) Assignable to any relay - sensor fail-safe Assignable to any stage level Time delay switching Selectable for make and brake of each sensor point (SP to SP2) 0-9,999 seconds VDC output supply, 0.5 A fused Analog output Six (6) independent signal, 500 Ω max. load, selectable as low, high or averaging of sensor inputs Audible alarm 85 db (0 ft), enabled or disabled, selectable; assignable to stage level S, S2, S3, S4 or S5 Alarm acknowledgment Menu-driven and system reset function for latched relays

Specifications subject to change without notice. USA 40804 Page 2 of 7 SPECIFICATION User Interface Keypad type Refer to section User Interface & Controller Touch buttons Six (6) Status LED s Yellow: Fault (fail) Red: Alarm Digital display Liquid Crystal Display (LCD), two lines, 6 characters per line, digit resolution, backlit - unit display Menu selectable, per sensor; ppm, %LEL, Vol%, F, %RH, %, ppk, C BACnet Interface, optional* Read status information via BACnet coupler and BACnet- Profile, BACnet-Services and BACnet BIBBs Input scaling 0-250 ppm CO Coupler option B 0-00% Coupler option P TCP/IP 0/00 Mbits/sec Connector Ethernet RJ45 Interface BACnet-Profile Description BACnet-Services Who-is (execute) I-am (initiate) ReadProperty WriteProperty Object types Version B.2, B2.2 Modbus Interface, optional* Read status Information via Modbus interface and Modbus function 6 and 03 Module Integrated at Controller module 9200 baud start-bit, 8 data-bits stop-bit, no parity Interface Function 6 Description Function 03 Addresses - 000 to 098 Current value internal, sensor -98-2000 to 2048 Current value external, sensor -98-3000 to 3098 Average value internal, sensor -98-0 to 6 Relay bits, relay to 30-8 to 9 Analog outputs to 2 Environmental Permissible ambient - working temperature 23 F to 04 F (-5 C to 40 C) - storage temperature -4 F to 04 F (-20 C to 40 C) - humidity 5 to 95% RH, non-condensing - working pressure Atmospheric + 0% Physical Enclosure (panel) - material Polycarbonate, impact resistance EN 5002/IK08, flammability rating UL 94-5V - conformity UL Type, UL 508 / UL 50 standards - color Light gray, smoked gray for cover - protection NEMA 4X (IP65) - installation Wall (surface) mounted Dimensions (H x W x D) - base 6.9 x 2.0 x 5.7 in. (430 x 306 x 45 mm) Cable entry 0 holes for /2 in. conduit, covered Wire connection Terminal blocks, Push-on connect and screw type for lead wire Wire size - input Min. 22 AWG (0.34 mm 2 ) Max. 6 AWG (.50 mm 2 ) - output Min. 24 AWG (0.25 mm 2 ) Max. 4 AWG (2.50 mm 2 ) Weight 2.0 lbs (5.5 kg) Approvals / Listings - unit rating NRTL Perf. Tested & Certified Conforms to STD ANSI/UL 207 City of Los Angeles CE VDI 2053, C-No. 4879 EMC-Compliance 89/336/EWG - enclosure (panel) UL Listed, E75645 Warranty Two years material and workmanship (*) BACnet Interface: NRTL Certification to UL STD 600- Pending

Specifications subject to change without notice. USA 40804 Page 3 of 7 ORDERING INFORMATION MGC2-2 - 500 US 00 0 B0 P0 M0 Options No options Key Lock w/2 keys BACnet Upwards Coupler C5-BAC-98 for AT Transmitters (0-250 ppm CO) BACnet Upwards Coupler C5-BAC-98- for AT Transmitters (0-00%) Modbus Upwards Port (integrated) Standard control system, ordering part number: MGC2-2 - 500 US, configuration includes: Digital, programmable controller with menu-driven key-pad user interface, LCD & LEDs, 20 VAC (90...250 VAC) 50/60 Hz, NEMA 4X enclosure Inputs: (2) (4) Digital Outputs: (5) Relays, SPDT, 8 A (6) (), 0.5 A

Specifications subject to change without notice. USA 40804 Page 4 of 7 USER INTERFACE & CONTROLLER Keypad User Interface Alarm Power INTEC 3.06.3 :45am Exits programming; returns to the previous menu level. Main Page & Main Menu INTEC 3.06.3 :45am System Errors Stage Status Relay Status Sensor Readings Relay Setup SP Setup Data Logger System Setup Alarm 2 - n Enters sub menus; saves parameter settings. Scrolls up & down within a menu; changes a value. Moves the cursor position. Fault System Operation All programming is made via the keypad user interface in combination with the display screen. Security is provided via two password levels. The lower level password (234) allows to override or to reset system status functions. The upper level password (900) allows all programming and override functions. Main Page Display After powered on, displays INTEC and Date/Time and changes to sensor reading display unless a system error occurs; then the error is displayed. Main Menu Displays headings of System Errors, Stage Status Relay Status, Sensor Readings, Relay Setup, SP (Sensor Point) Setup, Data Logger and System Setup. Sub Menu System Errors Displays errors, reset corrected errors, and historical error summary. Sub Menu Stage Status Displays status of each SP sensor point, stage level/setpoint exceeded. Sub Menu Relay Status Displays status and manual control of each output relay. Sub Menu Sensor Readings The current or average values are displayed for each SP sensor point with sensing type and engineering unit (ppm, %LEL, Vol%, F, %RH, %, ppk, C). Sub Menu Relay Setup Enter and/or change parameters of each relay. - Assign de-energized or energized normal operation - Select steady or flashing function - Select latching or non-latching mode - Select horn re-annunciation interval - Select digital input usage, and assign to any output relay - Set ON/OFF time delay Sub Menu SP Setup Enter and/or change parameters of each sensor point. - Activate/deactivate sensor point - Lock/unlock sensor point - Alarm on rising or falling value - Select sensor point type (gas, temperature, humidity) - Select full scale measuring range - Select sensor signal - Select stage/setpoint to 5 - Select hysteresis - Set delay ON/OFF time - Select current or average mode - Assign sensor point fault to stage level activation - Assign setpoint to 5 to any output relay - Assign to analog output Sub Menu Data Logger - Set data logger ON/OFF - Set sensor data logging ON/OFF - Set sensor data logging interval - Set alarm ( stage status ) logging ON/OFF - Set system error logging ON/OFF Sub Menu System Setup Enter and/or change system parameters. - Select service mode ON/OFF - Set next maintenance date - Select service phone number - Select averaging function, time and overlay, of any SP - Set date, time and time format - Change customer password - Select analog output function - Set failure relay - Select power ON time (alarm suppression) - Select appropriate hardware configuration - Assign relay multiplication

Specifications subject to change without notice. USA 40804 Page 5 of 7 FIELD WIRING CONFIGURATION Green/Ye G Gray X Gray H Blue N Green/Ye G (see ill. ) (see ill. 4) (see ill. 2) X 20 VAC Input Power 2 2 3 4 5 6 7 8 9 0 2 3 4 5 Fault Alarm INTEC Controls 05.07.0 0: 28am X0 X 2345678902 2345678902 Sensor Inputs Binary - Relay Outputs R06 R07 R08 R09 R0 Binary - Relay Outputs R0 R02 R03 R04 R05 Digital Analog Inputs Outputs (see ill. 5) (see ill. 6) (see ill. 2) (see ill. 2) DIN Rail Optional: Modbus Interface (see ill. 8) Binary - Relay Outputs RR2 R3 R4 R5 2 3 4 5 6 7 8 C5 Comm. Coupler Optional: BACnet X 2 3 4 (see ill. 7) Recommended Twisted, shielded wire for analog inputs (Shield to be terminated and connected only at the sensor/transmitter location or controller) Grounded housing Do not ground at both ends! Caution: The non-metallic enclosure does not provide grounding between conduit connections. Use grounding bushings and jumper wires. The enclosure is to be mounted using the mounting holes located in the base external to the equipment cavity, or the equivalent. The conduit hubs must be connected to the conduit before connected to the enclosure. When connecting conduit to the enclosure use only UL listed or UL recognized conduit hubs that have the same environmental type rating as the MGC2 enclosure. 2 2 3 4 5 6 7 8 9 0 2 3 4 5 2 2 3 4 5 6 7 8 9 0 2 3 4 5 X X EP-02- EP-02-2 X0 X X0 X DIN Rail C5 BACnet Coupler, optional (see ill. 4) 2345678902 2345678902 2345678902 2345678902 Sensor Inputs Analog Outputs Sensor Inputs Analog Outputs (see ill. 6) (see ill. 4) (see ill. 6) Terminal block X 2 Output Circuit breaker F (see ill. 3) 8 7 6 5 4 3 2 Power Unit Top L N G V- V+ Bottom Horn RJ45 Upwards BACnet communication to BAS ill. 7 20 VAC Input Power Supply ill. 8 Modbus Interface, optional (Located at Controller module) H N G Gray Blue Green/Yellow AC hot AC neutral Earth ground Terminal block 20 VAC (90...230 VAC), 50/60 Hz Min wire size 6 AWG (.5 mm 2 ) Resettable breaker, max 0 A, rated current approx. 2 A ill. 2 3 4 5 6 7 8 9 0 2 X MOD_A MOD_B 0 VDC

Specifications subject to change without notice. USA 40804 Page 6 of 7 FIELD WIRING CONFIGURATION (cont...) Binary - Relay Outputs R0 to R5 (Located at Controller module, EP-02- & EP-02-2 modules) Stage-level control & alarming #5 #4 #3 #2 # 2 3 4 5 6 7 8 9 0 2 3 4 5 R0 R02 R03 R04 R05 Normal condition (factory default) D D2 D3 D4 D5 = Relay status LEDs D to D5 located below terminal connection of sensor inputs (X0) Stage-level control & alarming #0 #9 #8 #7 #6 EP-02-2 3 4 5 6 7 8 9 0 2 3 4 5 R06 R07 R08 R09 R0 Normal condition (factory default) D D2 D3 D4 D5 = Relay status LEDs D to D5 located below terminal connection of sensor inputs (X0) Built-in horn alarming*** factory wired, Fault (fail) alarming Stage-level control & alarming ( ) (+) *** #3 #2 # H EP-02-2 *** Factory pre-configured horn and fault (fail-safe), can be reassigned/converted for remote control, stage-level #4 and/or #5 2 3 4 5 6 7 8 9 0 2 3 4 5 R R2 R3 R4 R5 Normal condition (factory default) D D2 D3 D4 D5 = Relay status LEDs D to D5 located below terminal connection of sensor inputs (X0) ill. 2

Specifications subject to change without notice. USA 40804 Page 7 of 7 FIELD WIRING CONFIGURATION (cont...) Output Supply 2 (+) (-) max 0.5 A for remote alarm display units Terminal block X ill. 3 Sensor Inputs SP0 to SP2 (Located at Controller module, EP-02- & EP-02-2) 2 3 4 5 6 7 8 9 0 X0 SP0 SP0/02- ( ) SP02 SP03 SP03/04- ( ) SP04 2-wire sensor / transmitter 3-wire sensor / transmitter ( ) EP-02-2 3 4 5 6 7 8 9 0 X0 EP-02-2 2 3 4 5 6 7 8 9 0 X0 SP05 SP05/06- ( ) SP06 SP07 SP07/08- ( ) SP08 SP09 SP09/0- ( ) SP0 SP SP/2- ( ) SP2 ill. 4 Digital Inputs DI0 to DI04 (Located at Controller module) 2 3 4 5 6 7 8 9 0 2 X ill. 7 & ill. 8, see page 5 ill. 5 Analog Outputs AO0 to AO06 (Located at Controller module, EP-02-, EP-02-2 modules) 2 3 4 5 6 7 8 9 0 2 Keypad User Interface signal to remote control or BAS, selectable low, high or averaging of (8) analog (sensor) inputs, 500 Ω max. load The current signal is sourced by the MGC system X (AO02) Com (AO0) 2 3 4 5 6 7 8 9 0 2 EP-02-2 3 4 5 6 7 8 9 0 2 EP-02-2 X (AO04) Com (AO03) X (AO06) Com (AO05) ill. 6