Indicomp 4 Bargraph Indicator

Similar documents
Digital Indicator DS 48/24 E

LineMaster 100 Continuous-line Recorder

LineMaster 200 Continuous-line Recorder

C160 Wall-/Pipe Mounted Universal Process Indicator

PointMaster 100. Multipoint Recorder 10/ EN

LineMaster 200. Continuous-line Recorder. ABB Instrumentation 10/ EN

LineMaster 100. Continuous-line Recorder. ABB Instrumentation 10/ EN

DINALOG A 144 x 36 A1400 Light-Strip Indicator

TEPI11 P/I signal converter

Data Sheet T 6493 EN. TROVIS 6400 Automation System TROVIS 6493 Compact Controller. For panel mounting (front frame 48 x 96 mm/1.89 x 3.

DS 96/48 PK. Digital indicator. Manual 42/33-90 EN Rev. 00 DIM

FICHA TÉCNICA DE PRODUTO

Wall-/Pipe Mounted Universal Process Indicator

/8 DIN Universal Process Indicator

/8 DIN Motorized Valve Controller

Process displays For current and voltage

Process controllers for the meat processing industry

FICHA TÉCNICA DE PRODUTO

Measuring transducers MI4x0 series Programmable transducers for RTD sensors MI450

KS 3012 PMA GENERAL DESCRIPTION

ABB i-bus KNX HCC/S Heating/cooling circuit controller

Plug-in module SIRAX TV 808, 2 channels Isolating Amplifier unipolar/bipolar

100mm Process Indicator Recorder

SM2000 Videographic recorder Spare parts and upgrade kits

Electronic timer CT-SDD.22 Star-delta change-over with 2 n/o contacts

v v PMA isolated by means of opto-couplers.

ABB i-bus KNX BCI/S Boiler/Chiller Interface

ABB Instrumentation. Specification DataFile COMMANDER 100. the-easy-to use 1. /8 DIN controller with extensive application capabilities

JUMO safetym TB/TW 08 Temperature limiter, monitor as per DIN EN

Inform IT Single Pen Circular Chart Recorder

LME620-AI/-AN (Contrac) Electrical Linear Actuator

ControlMaster CM15 Universal process indicator, 1 /8 DIN. Making process control easy

Messaging module CP-C MM

SM1000 Videographic recorder Spare parts and upgrade kits

Electronic timer CT-EBD.12 Flasher starting with ON with 1 c/o (SPDT) contact

Introduction. For more information. HART Protocol 7.0 Valid for software levels from 05.00

JUMO Quantum PID100/PID200/PID300

Dual Channel Monitor for Measurement of Speed and Ratio with SIL1 requirements Series D224.xx

Electronic Temperature Controller. Instruction Manual Version

Voltage monitoring relays CM-ESS.1 For single-phase AC/DC voltages

Electronic timer CT-SDS.23 Star-delta change-over with 2 n/o contacts

INDI BOY DSP Load limitation electronics

Pluggable interface relays CR-P Pcb relays

QUINT-PS/ 1AC/24DC/ 5

JUMO ctron 04/08/16 Compact controller with timer and ramp function

J itron DR 100 Microprocessor Controller

MINI MCR-SL-PT100-UI(-SP)(-NC)

RMZ782B RMZ783B. Extension Modules. Building Technologies HVAC Products. Synco 700. for heating controller RMH760B

Pluggable interface relays CR-M Miniature relays

Bargraph for quick range overview The digital indicators provide a bargraph in addition to the digital display. This gives you all information

Redundancy unit CP-D RU Accessory for CP range power supplies (e.g. switch mode power supplies CP-D range)

Pluggable interface relays and optocouplers CR-P Pcb relays, optocouplers and accessories

Controller module. Brief description. Features. Block structure. Page 1/7. Data Sheet

RTU511. Binary Output 23BO62. Characteristics. Application. Data Sheet Binary Output 23BO62. The binary output is made via relay contacts.

Strip Chart Recorders Specification Sheet

TRIO-PS/1AC/24DC/20. Extract from the online catalog. Order No.:

Product and Applications Description. Note. Example of Operation. Installation Instructions. Application Programs WARNING

JUMO ecotrans ph 03 Microprocessor transmitter/ switching device for ph/redox voltage and temperature

Electronic timer CT-ARE OFF-delayed without auxiliary voltage, 1 c/o (SPDT) contact

Duct Sensors. Building Technologies HVAC Products. Symaro. for relative humidity and temperature with calibration certificates

Crane-Boy / Crane-BoyP Load limitation electronics

APPLICATIONS. Furnaces and ovens Burners and boilers Weighing and batching Process control Plastics processing... DESCRIPTION

JUMO diraview 104/108/116/132

A2000 Multifunctional Power Meter

Adapter Plates for continuous Part-Turn Actuators (Contrac)

Electronic Preset Counter with 2 Presets and Print interface. NE213 Prog Features

AMC 8 & IOC 8T. Analog Monitoring Card Type AMC 8 and Input / Output Card Type IOC 8T FEATURES

Electronic timer CT-ARS.21 OFF-delayed without auxiliary voltage with 2 c/o (SPDT) contacts

Bus Connection Unit 560BCU04

Switching relay CT-IRE with 1 c/o (SPDT) contact

T M. IRDH375 Series. Digital Ground Fault Monitor / Ground Detector For Ungrounded (Floating) AC/DC Systems. Technical Bulletin NAE / 09.

Electronic timer CT-ERS.12 ON-delayed with 1 c/o (SPDT) contact

Compact Universal Controllers

QUINT-PS AC/24DC/10

SIMOCODE 3UF Motor Management and Control Devices

Room sensors QFA4160 QFA41 D AQF4150 AQF3153. Symaro. for relative humidity and temperature with calibration certificates

ControlMaster CM10 Universal process controller, 1 /8 DIN. Making process control easy

Compact universal controllers

Product and Applications Description. Application Programs. Note. instabus EIB Technical Product Information. June 2005

C1900 Series Circular Chart Recorder. C1900 a rugged, reliable recorder with the full capability to meet your needs

LineMaster 200. Continuous-line recorder. Parameter setting instructions 42/43-28 EN Rev. 03

Indicators. Hazardous-Area Indicators. 830 X R Loop-Powered 16 Process Indicator. 830 X S1 Loop-Powered 16 Process Indicator

Immersion Temperature Sensors

JUMO itron 04/08/16/32 Compact microprocessor controllers

THM501 PT100 MODBUS TEMPERATURE TRANSMITTER

ST 200 M data sheet System pro M compact miniature circuit breakers for supplementary protection acc. to UL 1077

Process Indicator PA308

I/O module, analogue outputs and universal inputs

Indicating Digital Transmitter for Differential Pressure and Flow. Media 6 with LCD Media 6 with LED

Redundancy unit CP-A RU

MINI MCR-SL-UI-2I(-SP)(-NC)

C1300 Advanced Circular Chart Recorder. C1300 dependable recording in a rugged, functional instrument

itemp TMT180 Technical information

DINALOG A 96 x 24. Programmable quasi-analogue bar graph meters. Technical characteristics DINALOG A 96 x 24

ABB MEASUREMENT & ANALYTICS DATA SHEET. C1300 Advanced circular chart recorder

Digital Indicator Solutions

ISOMETER isopv with coupling device AGH-PV

MINI MCR-SL-UI-REL(-SP)

1/32-DIN TEMPERATURE CONTROLLER INSTALLATION, WIRING AND OPERATION MANUAL FORM 3882

Thermocouples Resistance thermometer Resistance transmitter Potentiometer Voltage Current. for floating contacts or PLC level Functions:

Transcription:

Data Sheet 10/30-2.16-EN Indicomp 4 Bargraph Indicator Display is optionally LCD active: self-luminuous green on black self-luminuous green on blue LCD passive: self-luminuous black on light grey 2 input channels Direct current, direct voltage Thermocouple Resistance thermometer Maximum 4 alarm values Fully configurable via keys or PC Modular design Dimensions 36 mm x 144 mm Arbitrary characteristics

Technical data Display section Technology (optional) active: LCD, self-luminuous green on black or passive: LCD, self-luminuous black on light grey Analog display 2 bars each with 101 segments; 93 mm long Numerical display 4-digit; 12 segments; 10 mm high Range: -9999...0...(+)9999 digits Measurement section Measurement deviation (at 23 C ± 2 C) at mv, V, ma: < ± 0.1 % of measured value ± 0.025 % of upper-range value ±1 digit additionally with internal reference junction: ± 2 C Interference immunity CMR: > 120 DB for DC > 100 db for 50/60 Hz SMR: > 60 db for 50/60 Hz ( 1/10 of the upper-range value) Permissible common-mode voltage Circuit/circuit: isolating voltage (rms) 3 V Measuring circuit/ protective conductor: isolating voltage 25 V Scanning rate: Approx. 3/s per channel; measurement time: 100 ms Mean value calculation Can be parameterized (via 1...32 measurements) Measuring ranges DC Inputs Direct current -24...0...+24 ma; R i = 100 Ω Overload rating: 100 ma continuously Direct voltage -12...0...+12 V; Ri = > 100 kω Overload rating: 50 V continuously Any lower-range and upper-range values can be selected within the limits. Sensor Inputs Direct voltage 75...0...+75 mv; Ri = > 100 kω Overload rating: 50 V continuously Thermocouple (TC) Type Range limits Max. deviation J -200...+ 800 C ± 0.13 % of upper-range value K -100...+1300 C ± 0.16 % of upper-range value S 0...+1750 C ± 0.2 % of upper-range value R 0...+1750 C ± 0.2 % of upper-range value B +400...+1800 C ± 0.2 % of upper-range value T +100...+ 400 C ± 0.16 % of upper-range value E 0...+ 800 C ± 0.13 % of upper-range value N -100...+1300 C ± 0.15 % of upper-range value Temperature coeffizient: < 0.1 %/10 K in the range 0...50 C Resistance thermometer (RTD) Type Range limits Deviation Pt 100 IEC -200...+800 C ± 0.15 % of upper-range value Ni 100 DIN -60...+180 C ± 0.22 % of upper-range value Temperature coeffizient: < 0.1 %/10 K in the range 0...50 C 2, 3 or 4-wire connection (can be parameterized) with or without break monitoring (can be parameterized) Display in C or F (can be parameterized) Any lower-range and upper-range values can be selected within the limits. The resolution of the numerical display for spans within the range ± 999.9 digits is 0.1 C. Alarm value section Number of alarm values 4, freely assignable to the input channels Alarm value setting Internally: Externally: via keys with 0...20 ma or 0...10 V without electrical isolation Switching function Separate MIN or MAX, can be parameterized Hysteresis Can be parameterized jointly in the range 0...20 % Response time Can be parameterized jointly in the range 0...20 s Switching action Can be parameterized jointly, NO or NC contact operation Output Relay output 4 floating changeover contacts Operating values 18 V/10 ma DC min.; 250 V/1 A AC max. Transistor output 4-fold electrical isolation by means of opto-electronic couplers. Compatible for switch amplifier to DIN 19234 Operating values 30 V/40 ma Interface RS 232 C Accessible on the front after removal of the display RS 485 Routed on the rear to terminals Power supply 24 V universal current (UC) AC -15 %...+10 %; DC ± 25 % 0/48...62 Hz, 10 W/15 VA 115/230 V alternating voltage (AC) -20 %, + 10 %, 48...62 Hz, 10 W/16 VA External fuse protection (acc. to DIN 41662): T 0.8 A at 24 V AC/DC (UC) / T 0.25 A at 115/230 V AC Page 2 of 8

Technical data General and safety data Environmental capabilities Ambient temperature 0...50 C Transportation and storage temperature -25...65 C Relative humidity up to 95 %, no condensation Corresponds to climatic class KWF to DIN 40040 Climatic class 3K3 to DIN IEC 721 Part 3-3 Application field: industrial gas environments Electromagnetic compatibility (EMC) Immunity Tested to IEC 801, DIN VDE 0843 inter alia Protection objectives of the EMC guideline 89/336 EEC are fulfilled basic standard: pren 50082 Part 2, August 1992 The standard requirements of the NAMUR recommendations NE21 Teil 1, May 1993 are fulfilled. Radio interference suppression Alarm value class B based on Postal Service Ordinance VfG 243/1991 Mechanical features Tested to DIN IEC 68-2-27 and 68-2-26 Shocks 30 g/11 ms, vibration 2 g/5...150 Hz General and safety data Protection class I with protective conductor connection Connection Plug-in screw terminals for conductors up to 1.5 mm 2 (signal/control inputs) for conductors up to 2.5 mm 2 (power supply/signal outputs) Degree of protection acc. to DIN 40050; IEC 529 IP 50 Front panel IP 20 Terminals Colour Bezel Front film Grey RAL 7032 Grey RAL 7032 Grey RAL 7037 Grey RAL 7032 Mounting In a panel with screw clamps Close-packed, side by side mounting permitted Weight Approx. 1.4 kg Basic delivery 1 Indicomp 4 1 Operating Manual 42/30-26 EN Parameter definition Parameters can be defined for the following functions (via keys or via interface): Input Input variable Measuring range (start and end) Scaling (linear or any) Supplementary functions Alarm values Assignment to the inputs Function (MIN; MAX) Activation (internal/external) Operating principle (operating/quiescent current) Hysteresis, response time Display Bar beginning (bottom, top, center) Display on channel 2 (normal, sum, difference) Password Interlock of parameter definition Linearization In the dialog with level measurement (only via keys) Instrument alignment Supported by software (only via keys) 08.00 Page 3 of 8

Technical data Measured value and alarm value display Standard Absolut sum 1) Absolut difference 1) Floating difference Constant difference E2 / E1 1) E/2 1) Z1 Numerical display channel 1 E1 Input 2 K1 Channel 1 1) Special display on channel 2 Z2 Numerical display channel 2 E2 Input 2 K2 Channel 2 GW Alarm values (max. 4 values) Functions available as plug-in modules Display activ Transistor output Display passive Motherboard Relay output External alarm value activation Interface RS-232 C RS-485 Channel 2 Sensor input Z - 17508 EN Page 4 of 8

Ordering informations Catalog No Code DM LZ / deliv. V30615A- 1060,00 ** 2 W Display version passive: no illumination 1 - active: with illumination (black background) 2 206,00 ** with illumination (blue background) 3 206,00 ** Input channels single-channel 1 - two channels 2 196,00 ** Input signals 5) DC (ma, V) supplement measuring range(s) with Code Nos. 1 - DC (ma, V) + sensor inputs (mv, TC, RTD) provide measuring range(s) with Code Nos. 2 175,00 ** Alarm values (4 values) none 0 - Relay output internal activation 1 196,00 ** Relay output external activation (see Code No. 61) 2 350,00 ** Transistor output internal activation 3 196,00 ** Transistor output external activation (see Code No. 61) 4 350,00 ** Interface none 0 - Serial interfaces RS 232 and RS 485 1 144,00 ** Power supply 115/230 V alternating voltage (AC) 1-24 V alternating/direct voltage (UC) 2 201,00 ** Bezel grey (RAL 7032) 1 - grey (RAL 7037) 2-5) with no specification, default setting 20 ma, scale 0...100 %, figures 0...100,0 08.00 Page 5 of 8

Supplementary ordering information Code DM LZ / deliv. Input 1 (E1) Measuring ma (clear text) 310 - range 1) mv (clear text) 311 - V (clear text) 312 - Thermocouple 2) (clear text) 320 - Resistance thermometer 2) (clear text) 330 - with thermocouple (TC) internal reference junction 321 - external reference junction (clear text) 322 - with resistance thermometers (RTD) 2-wire circuit 332-3-wire circuit 333-4-wire circuit 334 - numerical display for DC measuring ranges 3) (clear text) 340 15,50 ** Scale according to standard series 4) (clear text) 350 31,00 ** according to specification 4) (clear text) 351 62,00 ** 0...100 % 352 - Input 2 (E2) 5) Measuring ma (clear text) 410 - range 1) mv (clear text) 411 - V (clear text) 412 - Thermocouple 2) (clear text) 420 - Resistance thermometer 2) (clear text) 430 - with thermocouple (TC) internal reference junction 421 - external reference junction (clear text) 422 - with resistance thermometers (RTD) 2-wire circuit 432-3-wire circuit 433-4-wire circuit 434 - numerical display for DC measuring ranges 3) (clear text) 440 15,50 ** Scale according to standard series 4) (clear text) 450 31,00 ** according to specification 4) (clear text) 451 62,00 ** 0...100 % 452 - special display on channel 2 (standard: value for input 2) Sum E1 + E2 510 - Difference E1 - E2 511 - Difference E2/E1 floating 512 - Difference E2/constant 513 - Value for constant (specification as percentage; standard: 50 %) (clear text) 514 - external alarm value setting 0...20 ma 610-0...10 V 612 - Inscription 3 mm character height (max. 14 characters) (clear text) 710 38,00 ** 2,5 mm character height (max. 17 characters) (clear text) 712 38,00 ** 2 mm character height (max. 22 characters) (clear text) 714 38,00 ** Operating Manual 5) German Z1D 8,00 English Z1E 8,00 French Z1F 8,00 1) observe measuring range alarm values 2) specify sensor type, temperature range (lower-range and upper-range values and decimal point position) and dsplay ( C or F) 3) specify lower-range and upper-range values and decimal point position 4) specify lower-range and upper-range values and dimension 5) with no specification, default setting 20 ma; scale 0...100 %; figures 0...100,0 6) 1 copy in German included in the basic supply; no specification required; extra Operating Manuals must be paid (please specify number) Page 6 of 8

Ordering information accessories Catalog No. Code DM LZ / deliv. Software Indicomp 4 Configuration program diskette 3,5" 30695-3100395 165,00 * 1 W diskette 5,25" 30695-3100396 165,00 * Connecting cable for RS 232 with 9-pin Sub-D socket connector 30804-0761781 92,00 * (2 m long) Mounting frame for Mauell grid (144 mm x 48 mm) 30604-0783518 41,00 * Fastening element for Siemens grid 30604-0783504 15,30 * Ordering information spare parts Display module passive, complete; RAL 7032 (no front film) 30604-0761976 313,00 * 2 W Display module passive, complete; RAL 7037 (no front film) 30604-0761977 313,00 * 2 W Display module active, with illumination module complete 30604-0761979 499,00 * 2 W RAL 7032 (no front film) 2 W Display module active, with illumination module complete 30604-0761980 499,00 * 2 W RAL 7037 (no front film) 2 W Illumination module, separate, for active display 30604-0761950 82,00 * 2 W 2nd input channel module (no sensor input) 30604-0761927 209,00 * 2 W Sensor input module (thermocouples, resistance thermometer) 30604-0761975 187,00 * 2 W Relay output module (4 modules) 30604-0761929 209,00 * 2 W Transistor output module (4 modules) 30604-0761928 209,00 * 2 W External alarm value setting module, 20 ma 30604-0761974 165,00 * 2 W External alarm value setting module, 10 V 30604-0761973 165,00 * 2 W Interface module RS 232 / RS 485 30604-0761958 153,00 * 2 W Front film for display module passive 30604-0780083 38,00 * 2 W Front film for display module active (green on black) 30604-0780084 38,00 * 2 W for display module active (green on blue) 30604-0780095 38,00 * 2 W with scaling for channel 1 acc. to standard series 1) (clear text) 350 33,00 * 2 W with scaling for channel 1 acc. to specification 1) (clear text) 351 66,00 * 2 W with scaling for channel 1 0...100 % 352-2 W with scaling for channel 2 acc. to standard series 1) (clear text) 450 33,00 * 2 W with scaling for channel 2 acc. to specification 1) (clear text) 451 66,00 * 2 W with scaling for channel 2 0...100 % (clear text) 452-2 W Insription plate RAL 7032, blank (5 plates) 4,40 * 2 W or in each case piece inscribed with 3 mm (14 charcters) (clear text) 710 40,40 * 2 W or in each case piece inscribed with 2.5 mm (14 charcters) (clear text) 712 40,40 * 2 W or in each case piece inscribed with 2 mm (14 charcters) (clear text) 714 40,40 * 2 W 1) specify lower-range and upper-range value and dimension 2) The scaling is independent of the dimension. The right scaling (channel 2) can be affected with max. 3 figures including sign. Figures with more digits are expressed as factor. Standard series for scaling 2) 0...10 200...300-50...0...+50 0...50 300...600-100...0...+100 0...100 400...500-30...+150 0...200 400...800-10...+40 0...250 800...1300 0...400 900...1200 0...600 1000...1600 0...900 1000...1750 0...1000 1400...1800 0...1200 0...2500 0...4000 08.00 Page 7 of 8

Connection diagram Input Channel 1 Channel 2 Resistance thermometer (RTD) E1 E2 4 - wire 3 - wire 2 - wirer mv / thermocouple (TC) V ma 11 19 13 21 14 22 15 23 17 25 12 20 + mv - + TC + + - V ma - - External alarm value setting Alarm signal output Relay Transistor Power supply 91 +L1 93 +L2 95 +L3 97 +L4 99 ACKN 92 - GND 56 54 55 46 44 45 L4 L3 1 2 1 2 L N PE L1 N PE U H U H = 115/230 V AC = 24 V UC Interface RS-485 86 DGND (PE) 85 DGND (PE) 84 RxD / TxD-B 83 RxD / TxD-B 82 RxD / TxD-A 81 RxD / TxD-A 53 51 52 43 41 42 L2 L1 Contact position of the relays in the de-energized state Transistor is blocked in the case of NC contact operation and alarm value inringement Interface RS-232 TxD RxD SELECT GND Z - 17507 Dimensional drawing (dimensions in mm) +1 138 144 +0,6 33 36 331 8,9 136,2 Panel cutout Z - 16781 307 ABB Automation Products GmbH Höseler Platz 2 D-42579 Heiligenhaus Phone +49(0)20 56-12 51 81 Fax +49(0)20 56-12 50 81 Subject to technical changes. Printed in the Fed. Rep. of Germany 10/30-2.16 EN 08.00

Contact us ABB Ltd. Process Automation Howard Road, St. Neots Cambridgeshire, PE19 8EU UK Phone: +44 (0)1480 475321 Fax: +44 (0)1480 217948 ABB Inc. Process Automation 125 E. County Line Road Warminster PA 18974 USA Phone: +1 215 674 6000 Fax: +1 215 674 7183 Note We reserve the right to make technical changes or modify the contents of this document without prior notice. With regard to purchase orders, the agreed particulars shall prevail. ABB does not accept any responsibility whatsoever for potential errors or possible lack of information in this document. We reserve all rights in this document and in the subject matter and illustrations contained therein. Any reproduction, disclosure to third parties or utilization of its contents in whole or in parts is forbidden without prior written consent of ABB. Copyright 2011 ABB All rights reserved 3KXJ200001R1001 10/30-2.16-EN 01.2011 ABB Automation Products GmbH Process Automation Borsigstr. 2 63755 Alzenau Germany Phone: +49 551 905-534 Fax: +49 551 905-555 www.abb.com