QUICK START GUIDE. 2.4 Inch Finger Vein Terminal Time Attendance & Access Control

Similar documents
QUICK START GUIDE. 2.4 Inch TFT Terminal Time Attendance & Access Control

INSTALLATION GUIDE 2.4 Inch TFT Terminal Time Attendance & Access Control

Quick Start Guide. ProBio & ProFAC + ZKBioSecurity 3.0

Finger Vein Access Control device Quick Start Guide Version: 1.0 Date: June USB slot. USB slot

GENERAL QUICK START GUIDE

Safety Precautions How to place the finger Product Contents Product PIN Diagram Product Dimensions Cables and Connectors Installation of Back Plate

USER MANUAL. BioPro SA50 Fingerprint & Palm Terminal. Version: 1.0 Date: August Inch TFT Terminal User Manual 1

W Series. Color Screen Fingerprint & Card Time Attendance and Access Control W 1 W 2

INSTALLATION GUIDE. InBio Pro Series Access Control Panels. Date: June, 2016 Version: 1.3

SF200. Installation Guide & Quick Start Guide. 2 TFT AC Terminal Version: 1.0 Date: June 2014

C5S120 Installation and Connection Guide

Biometrics Device Access controller Fingerprint & Finger Vein V Connector Table () Cable: P Wire Application Anti-Tamper Switch Wire Color Red Orange

SCR100 User Manual. Version:1.1 Date:Dec 2009

Zodiac FR100 TM INSTALLATION MANUAL

F18. Fingerprint capacity 3,000 Transaction capacity 100,000 Hardware Platform ZK 6001, 400Mhz 64M Flash, 32MSDRAM. Identification speed

Operation manual For NG BIOSINGLE Version 1.1

Portals 14 What is a portal? 14 Hardware 15 RS232 to RS USB to RS TCP/IP to RS Add a Serial Portal 16 Add a Network portal 16

P4 P5 P6. Security trigger signal 2 Purple Security trigger signal Output 6 Thin Blue Wiegand DAT: 1 Input

User Manual. Before using this device, read and follow all instructions for safety

H2i. s u p p o r f i n g e r t e c. c o m. H2i. Simple Fingerprint Door Access & Time Attendance System. User Guide

Quick Installation Guide MAC1000/MAC1000SR STANDALONE BIOMETRIC CONTROLLER

ACCESS CONTROL QUICK INSTALL GUIDE. tel: +44 (0) fax: +44 (0) web:

CV-550SPK V2 Waterproof Keypad/Reader/Controller Installation Instructions

iclock Access control Installation

Installation & User Manual

Fingerprint Access Control F1. User Manual

Professional Access Control

iclock serial Time & Attendance and Access Control Terminal Installation Instructions

Instruction Manual. Vogue. Security. Technology. Innovation 2013-V01

Installation Instructions

Installation & User Manual V2.08

Akcess BioMetrics Corporation. Bio2Touch. Access Control Fingerprint Reader. User's Manual. Akcess BioMetrics Corporation

Webpass IP Reader Installation Guide

CM-110SK Standalone Keypad Installation Instructions

F6-Fingerprint. Access Control/Reader. User Manual. F6 - Simplified Instruction. (Master Code) # (Factory default:1234) Enter the Programming Mode

Fingerprint Access Standalone User s Manual

CV-110SPK Standalone Keypad/Prox Access Control Installation Instructions

2000 Series e/em Style Keypad Installation and Programming Manual

Installation Instruction

TFT screen Fingerprint Machine

GV-AS/EV Controller. User s Manual

KP2000E/EM Series Style Keypad

Two Door Controller GEN-045

Single Door Standalone Access Control User Manual

CA111x-series Arming Station

Installation Guide (ver 1.0)

BF-630X/BF-830X WEB SCREEN. Access Control/Time Attendance. User s Manual

uface800 Time Clock User Manual uface800

F11 Installation Guide. Version: 1.0 Date: Jul. 2010

EL-ST100 KEYPAD CONTROLLER

GV-AS Controller. Installation Guide

MorphoWave Tower. Quick User Guide V

Access control panel U-Prox IC E (Elevator control)

Connecting a Cisco Reader Module

5.5 AS Layout. GeoVision Technical Handbook 77

CRC220 and CRC221 INSTALLATION GUIDE. REF No.: DOC0014 ISSUE: 09

F7_F707_F708 Installation Instruction V1.0 F7_F707_F708. Access Control Terminal. Installation Instructions

F & SC Serial Access Control Station. Installation Guide

genesis TECHNICAL MANUAL Two-Door Controller GEN-045

CP150B Vandal & Weather Resistant Keypad Security Systems

BioPointe Reader Installation Guide

Digital Keypad Introduction

DOLXFD1000B. Waterproof Access Control/Reader

Partizan PAB-FC2. Fingerprint scan time Fingerprint identification time. <0.5 s < % <0.0198% Ingress protection rating

User Manual Version 1.1 Date: March 2012

Wiring Guide EP.NMINI. Version 1.02 Last Updated:

smartentry Wireless Video Doorphone User Manual

Function Menu. 1.Add/Delete. 1. Password 2. Access Mode 3. Extend Options 4. Single Floor 5. Multi Floors 6. Enroll FP 7.

ACCESS CONTROL SYSTEM

Simple Card Reader for Door Access & Time Attendance System. User Guide

User Manual. Split access control with intelligent secured power supply.

Waterproof. Keypad/Reader/Controller

iface Series Installation Guide

REX F-0-9 Standalone or Access Controller

Quick Start Guide. GV-CS1320 Camera Access Controller

GV-AS/EV Controller. User s Manual

Face & Fingerprint Recognition Product

Operation Manual. Thank you for selecting Keyking products. Please read this manual thoroughly before use. Models: TC418/419 Standalone Controller

W3-H Waterproof Keypad/Reader/Controller

This document mainly introduces the windows and operations of the F18 model 2.4 inch color TFT product.

INSTALLATION INSTRUCTIONS Model 930 EntryCheck

2.4 inch Color Screen Series User Manual

User Manual Version 1.1 Date: November 2011

INSTALLATION GUIDE BioLite Net English Version 2.10 EN BLN V2.10A

Standalone Keypad Access Control. User Manual. Please read the manual carefully before use this unit

Standalone Keypad Access Control. User Manual. SS-TS2000 Size:120*80*25 mm

Hardware. - (0191)

IP based Fingerprint Access Control. Installation Guide.

232iLM Keypad Installation and Programming Instructions

Pegasus Equipments Export Limited. Local Contact:

USER MANUAL. 4.3-inch Touch Screen & Palm Attendance Terminal. Version: 1.0 Date: August, 2017

A-1300 Biometric Access Control System USER'S MANUAL

AC-115 Compact Networked Single-Door Controller Hardware Installation and Programming

3 inches Facial & Fingerprint Recognition

Installation Instructions. i-net Access Control Units. Part Code: IA-PCB IA-ACB IA-ACU IA-KIT

3 Inches Color TFT Serials User Manual

IPassan Installation guide

Quick Start Guide V5.0

CC Series metal access control Manual

Connecting a Cisco Output Module

Transcription:

QUICK START GUIDE 2.4 Inch Finger Vein Terminal Time Attendance & Access Control Version: 1.0 Date: Apr., 2017

1

2.4-Inch TFT LCD USB Storage Device Port Keypad& Card Reader Doorbell & LED Indicator Fingerprint Sensor Security Screw holes (for securing the device onto the back plate) 2

485B 485A TXD RXD WD1 WD0 12pin Cable connectors Alarm Lock Exit Button Door Sensor Doorbell Auxiliary In 2 pin Cable connectors Power In 7 pin Cable connectors 8 pin Cable connectors Beep, LED Wiegand In Power Out RS485 Rs232 Wiegand Out Tamper alarm button AL+ BELL- AL- 1 1 1 BUT SEN BELL+ AUX Alarm Lock Bell RJ45-6 RJ45-3 RJ45-2 RJ45-1 Ethernet Button RS485 Door Sensor RS232 Auxiliary In Power Wiegand Out BEEP GLED RLED IWD1 IWD0 Wiegand In Output Power Out 3

Product Dimensions & Installation Product Dimensions (210.9mm) (80.1mm) (96.4mm) Mounting the device onto the wall Fix the back plate onto the wall using wall mounting screws Note: We recommend drilling the mounting plate screws into solid wood (i.e. stud/beam). If a stud/beam cannot be found, then use the supplied drywall plastic anchors. Inserting the device to backplate 4 Use security screws to fasten the device to back plate

Power Connection Recommended power supply 12V ± 10%, at least 500mA. To share the power with other devices, use a power supply with higher current ratings 5

Ethernet Connection LAN Connection Access Software Note: The device can be connected to PC directly by ethernet cable. 6

RS485 Connection PC Connection P DESCRIPTION WIRE 1 485B Yellow 2 485A Blue 3 Black 4 TXD Purple 5 RXD Gray 6 Black 7 WD1 White 8 WD0 Green Do not use Important Notes: 1.RS485 communication wires should be a shielded and twisted pair of cable. 2.RS485 communication wires should be connected in a bus cascade instead of a star form, to achieve a better shielding effect by reducing signal reflection during communications. 3.Adjust the communication speed as needed. The signal quality varies with wiring conditions, and it may be necessary to lower the baud rates. 4.The signal may be omitted if and only if the potential difference is less than ±5V. 7

Lock Relay Connection Device Does Not Share Power With The Lock + - Notes: 1. The system supports LOCK and LOCK. For example the LOCK (normally opened at power on) is connected with '1' and '1' terminals, and the LOCK (normally closed at power on) is connected with '1'and '1' terminals. 2. When electrical lock is connected to the Access Control System, you must parallel one FR107 diode (equipped in the package) to prevent the self-inductance EMF affecting the system.! Do not reverse the polarities.

Lock Relay Connection Device Shares Power With The Lock + -

PC 485+ 485- S SEN SEN SEN SEN V+ V- 485-485+ PWR RUN ACT GRD BEEP GLED WD1 WD0 BEEP GLED WD1 WD0 BEEP GLED WD1 WD0 BEEP GLED WD1 WD0 2 Wiegand Output Connection 2 LAN SWITCH PC AUXOUT1 AUXOUT2 AUXOUT3 AUXOUT4 LOCK1 LOCK2 LOCK3 LOCK4 LOCK POWER Advanced Access Control Best Security Solution for the World EXT RS485 RS485 CARD RUN POWER AUX 1 AUX 2 AUX 3 AUX4 EXT STATE READER 2 BUTTON 3 READER 3 BUTTON 4 READER 4 BEEP GLED WD1 WD0

Standalone Installation Access Software Access Software No Touch

Device Operations Date / Time Settings Press M/OK > System > Date Time to enter Date Time setting interface. Adding User Press M/OK > User Mgt. > New User to enter the adding New User interface. Settings include inputting user ID, choosing user role (Super Admin / Normal User), registering finger vein / fingerprint / badge number / password, taking user photo, and setting access control role. Adding a Super Admin: Select Super Admin in User Role to add a super admin. Adding a Normal User: Select Normal User in User Role to add a normal user. Ethernet Settings Press M/OK > Comm. > Ethernet to enter the Ethernet setting interface. The parameters below are the factory default values, please adjust them according to the actual network situation. IP Address: 192.168.1.201 Subnet Mask: 255.255.255.0 Gateway: 0.0.0.0 DNS: 0.0.0.0 TCP M. Port: 4370 DHCP: Dynamic Host Configuration Protocol, which is to dynamically allocate IP addresses for clients via server. If DHCP is enabled, IP cannot be set manually. Display in Status Bar: To set whether to display the network icon on the status bar.

Device Operations & Troubleshooting Access Control Settings Press M/OK > Access Control to enter the Access Control setting interface. To gain access, the registered user must meet the following conditions: 1. User's access time falls within either user's personal time zone or group time zone. 2. User's group must be in the access combo (when there are other groups in the same access combo, verifications of members of those groups are also required to unlock the door) Access Control Options: To set parameters of the lock and other related devices. Time Schedule: The smallest unit for access control. Holidays: To set dates of holiday and the access control time zone for that holiday. Access Groups: To divide and manage users in groups. Group members can either use the default group time zone or customize a personal time zone. Combined Verification: Combinations of verification methods Anti-passback Setup: To avoid unverified individuals from following the registered users to enter the door. Duress Options: If users unlock the door under threat, the device will open the door, meanwhile send signals to the backstage to trigger the alarm. Troubleshooting 1. Fingerprint cannot be read or it takes too long. Check whether a finger or fingerprint sensor is stained with sweat, water, or dust. Retry after wiping off finger and fingerprint sensor with dry paper tissue or a mildly wet cloth. If a fingerprint is too dry, blow on the finger and retry. 2. Fingerprint is verified but authorization keeps failing. Check whether the user is restricted by group or time zone. Check with administrator whether the enrolled fingerprint has been deleted from the device for some reasons. 3. Verification succeeds but door does not open. Check whether the lock open duration is set to appropriate time, which opens the lock. Check whether anti-passback mode is in use. In anti-passback mode, only the person who has entered through that door can exit. 4. The device displays system broken and the alarm is ringing. Check whether the device and back plate are securely connected to each other. If not, a tamper switch will be activated which triggers the alarm and keeps it rinng.