Technical specifications

Similar documents
RE17LAMW on-delay timing relay - 1 s..100 h V AC/DC - solid state output

RE17LAMW on-delay timing relay - 1 s..100 h V AC/ DC - solid state output

RE17LCBM off-delay timing relay - control - 1 s..100 h V - solid state output

RE22R1QMQ star-delta timing relay - 230VAC/440VAC - 1 C/O

RE22R1QMQ star-delta timing relay - 230VAC/440VAC - 1 C/ O

RE22R2AMR On-delay Timing Relay s 300h V AC/DC - 2C/O

02/11/2015

Electronic timer CT-ERD.12

Electronic timer CT-AHD.22

RE22R2AMR On-delay Timing Relay s 300h V AC/DC - 2C/O

RE22R2CMR Off-delay Timing Relay s 300h V AC/DC - 2C/O

RE48ATM12MW on-delay timing relay s..300 h V AC - 2 OC

Type VRLTC tap changer

RE22R2KMR Off-delay Timing Relay s 10min V AC/DC - 2C/O

02/11/2015

Electronic timer CT-ERS.21

RE22R2QGMR Star-Delta Timing Relay s 300h V AC/DC - 2C/O

08/07/2015

RE11RAMU on-delay timing relay - 1 s..100 h V AC - 1 OC

RE22R2QTMR Star-Delta Timing Relay s 300h V AC/DC - 2C/O

Electronic timer CT-ERS.12 ON-delayed with 1 c/o contact Data sheet

RE48ATM12MW on-delay timing relay s..300 h V AC - 2 OC

TM3DI16 module TM3-16 inputs

Electronic timer CT-ARS.11

TM3AI4 module TM3-4 analog inputs

RE Product data sheet Characteristics. time delay relay for star-delta starter ms - 230/380 V AC - 1 contact. Main.

Syr-line TMR48D Digital Timer

Conforms to VDE0435/2021 C/250, VDE0110, VDE0106/P100 Conforms to EN , pren

Electronic timer CT-ARS.21 OFF-delayed without auxiliary voltage with 2 c/o (SPDT) contacts

TM3TM3 module TM3-2 temperature inputs and 1 analog output

Relion 611 series. 611 series Type Test Certificate

TM3TI8T module TM3-8 inputs temperature

RE Product data sheet Characteristics. universal plug-in timing relay - flashing s..60 mn V AC - 2 OC. Main.

RE22R1AMR On-delay Timing Relay s 300h V AC/DC - 1C/O

TM3TI4 module TM3-4 inputs temperature

TM3DI16G module TM3-16 inputs spring

Output Voltage* (nom.)(adjustable)

RTU500 series Data Sheet Power Supply CP-E 24/2.5

Output Voltage* (nom.)(adjustable)

Electronic timer CT-APS.21 OFF-delayed with 2 c/o (SPDT) contacts

Solid-state Timer. Ordering Information. Miniature Timer with Multiple Time Ranges and Multiple Operating Modes H3YN- - Accessories (Order Separately)

Syr-line TMR48D Digital Timer

Electronic timer CT-AHS OFF-delayed with 2 c/o contacts Data sheet

Solid-state Timer H3YN

NOVOHALL Rotary Sensor non-contacting. Series RSC2800 digital SSI, SPI, Incremental

TF501, TF521 Terminal Bases

Electronic timer CT-ARS.11 OFF-delayed without auxiliary voltage with 1 c/o (SPDT) contact

Vert-X 05E 5V / % Ub. Application Access control systems Forklift

RM22TG. Product data sheet Characteristics. three-phase control relay Vac, 2 C/O. Main. Complementary. Network number of phases

Control Panel CP600-eCo CP604, CP604-B

Vert-X 32E - 24V / CANopen, redundant. Applications Forklifter Platformer Agricultural machine. Features. CiA approved CiA V402/

RTU511. Binary Output 23BO62. Characteristics. Application. Data Sheet Binary Output 23BO62. The binary output is made via relay contacts.

TM3TI4 module TM3-4 inputs temperature

Energy Management Modular DC Energy analyzer Type VMU-E and VMU-X

Appearance Size (mm) Power supply voltage Model (W H D) 100 to 240 VAC K3SC to 240 VAC

General information. Display. Supply voltage. Input current. Encoder supply. Output current

General information. Supply voltage. Input current. Encoder supply. Power loss. Memory

Test and Measurements Automated Systems Component Device Testing Semiconductor Processing & Burn-in Aerospace & Satellite Testing

Model Number Structure

TU531, TU532 Terminal Unit

FL MC 2000E (SM40) LC

General information Engineering with Programming package. Display with display

Chrome DIN Rail Power Supply 5V 7.5W 1 Phase (Class II & NEC Class 2) / DRC-5V10W1AZ

G3PC. Model Number Structure. Solid State Relays with Failure Detection Function. Model Number Legend

Chrome DIN Rail Power Supply 12V 9.96W 1 Phase (Class II & NEC Class 2) / DRC-12V10W1A

General information. Display. Supply voltage. Input current. Encoder supply. Power losses

INSTRUCTION MANUAL TRIP CIRCUIT SUPERVISION RELAY GKAD1

Zelio Count - Counters RC87610

Display. Supply voltage. Input current. Encoder supply. Output current. Power losses. Memory

General information. Display. Supply voltage. Input current

General information. Display. Supply voltage. Input current. Encoder supply. Output current

SIPROTEC easy 7SJ45 Numerical Overcurrent Protection Relay Powered by CTs

93 SERIES. Timed socket for 34 series 93.68/93.69

Electronic timer CT-EAS ON-delayed and OFF-delayed with 1 c/o contact Data sheet

General information. Display. Supply voltage. Input current. Encoder supply. Output current

Voltage Current Front-mounting bracket

HMISBC Rear Module controller panel - Dig 8 inputs/8 outputs +Ana 4 In/2 Out

VER05 Series. xxx Series. 5 Watt. AC-DC Power Supplies. Models & Ratings. Input. Output

CD522 Encoder, Counter and PWM Module

TM221M16R controller M IO relay

TM3DI8A module TM3-8 inputs 120V AC

Combined Overcurrent and Earth-fault Relay SPAJ 140 C. Product Guide

Electronic timer CT-ERS.12 ON-delayed with 1 c/o (SPDT) contact

Control Panel CP600 CP635, CP635-B, CP635-WEB

Functional configuration Rated input voltage Power ratings Output voltage Output current Part number Non-PFC

CompactBlock Guard I/O EtherNet/IP Safety Modules

General information Engineering with Programming package. Display with display. Supply voltage 24 V DC Yes. Input current

PDD-300 pulsed diode driver

Control Panel CP600 CP651, CP651-WEB

Communication Gateway COM 610. Product Guide

HMISCU6A5 3 5 color touch controller panel - Dig 16 inputs/10 outputs

Electronic timer CT-EBD.12 Flasher starting with ON with 1 c/o (SPDT) contact

Part No. Description Product Life Cycle Phase *) unit, 24 VDC, spring terminals. unit, 24 VDC, spring terminals, XC version

General information. Display. Supply voltage

XPSMF40. Main. Safety module name. Monitoring safety detection discrete input Monitoring safety dialogue discrete output

AO523 Analog Input Module

HMISCU8A5 5 7 color touch controller panel - Dig 16 inputs/10 outputs

Protection and control. Sepam range Sepam 100 RT. Merlin Gerin Square D Telemecanique

Safety Standards. Model Number:

ICS Regent. Relay Output Modules. Low Power and High Power (T3446L and T3446H) PD-6017

Transcription:

Technical specifications General information Operating temperature -25 to 60 C Storage temperature -40 to 70 C Enclosure type Panel installation (DIN IEC 61554) Enclosure fixing Screw-type clamping technology Enclosure colour black (RAL9005) Enclosure front 72x72mm Panel cutout 68x68mm Installation depth 63mm (without connector) Degree of protection Front IP54 Rear IP20 Enclosure fire behaviour UL94 V0 Conformity EN 61812-1:2012 Rated voltage 250VAC Electrical isolation all inputs, outputs and power supply Behaviour in case of power failure Time remanence, parameterisable Supply Voltage range Rated frequency AC Rated power consumption Inputs Voltage range Rated frequency AC Rated current Minimum pulse duration Input functions Outputs Contact configuration Contact use (changeover contacts) Instantaneous contact, parameterisable 90 to 265V AC/DC 50/60Hz 2W 20.4 to 265V AC/DC 50/60Hz <2mA 100ms Start; Stop/; time range changeover 2 changeover contacts, floating 2 time closing contacts or time closing contact / instantaneous contact for all time functions Page 1

Rated voltage Contact rating Minimum contact load Life 250VAC 5A ohmic 5VAC/DC, 100mA ohmic >100,000 cycles Controls Time setting Incremental encoder, 360 Manual time control joint button for the Start / Stop / functions Function parameterisation DIP switch (rear of device) Instantaneous contact DIP switch (rear of device) parameterisation Time range parameterisation DIP switch (rear of device) Remanent response parameterisation DIP switch (rear of device) Display elements Runtime Response time Time range display Switched status display Time functions Time ranges, parameterisable Setting ranges Time control Switching functions, parameterisable 7-segment display WxH: 50x19mm, red 7-segment display WxH: 32x10mm, red green LED red LED hh:mm / mm:ss 0:01-99:59 hours 0:01-99:59 minutes manual and external - Operate delay - Release delay - Passing make contact - Passing break contact - Clock pulse generator starting with pause - Clock pulse generator starting with pulse Terminal assignment K1 relay output with changeover contact K2 relay output with changeover contact Max. 250VAC, 5A External control inputs 20.4-265V AC/DC Start: Pulse min. 100ms Stop: Pulse min. 100ms : Pulse min. 3s Time base: Continuous signal Supply voltage 90 265 V AC/DC DIP1 Instantaneous contact configuration on K2 = instantaneous contact off K2 = time closing contact DIP1-3 time function configuration Bit1 Bit2 Bit3 Function off off on Operate delay off on off Release delay off on on Passing make contact on off on Passing break contact on on off Clock pulse generator starting with pause on on on Clock pulse generator starting with pulse Page 2 DIP5 Remanence configuration on Storage of the time setting off no remanence DIP6 Time base configuration on Time base mm:ss

Page 3

Functional description Operation - Time setting The time is preset uniformly for all time functions using a rotary knob/incremental encoder. Turning clockwise increases the time with each latching of the incremental encoder depending on the set time range hh:mm - increase by 1 minute mm:ss - increase by 1 second Turning anti-clockwise reduces the time with each latching of the incremental encoder depending on the set time range hh:mm - reduce by 1 minute mm:ss - reduce by 1 second The time can only be set if the time sequence is inactive. If the time sequence is active or paused, actuating the rotary knob/incremental encoder has no effect. - Button The optional button or push function of the incremental encoder included in the default configuration starts the time sequence with inactive time sequence (Start). Actuating while the time sequence is active (Stop) freezes the runtime. The time sequence pauses. The time sequence can be continued by actuating the button during paused time sequence (Start). Pressing the button continuously without interruption for a period of at least 3 seconds in each operating case results in resetting of the time sequence with the following consequence: Cancellation of the time sequence and updating of the runtime display with the preset target runtime All outputs switched to the initial state Switching off the status LED - START input The START input starts the time sequence with a high pulse of at least 100ms and inactive time sequence. A high pulse with minimum length 100ms at the START input during paused time sequence continues the active time sequence. In all other operating states the input has no effect. - STOP () input A high pulse with minimum length 100ms at the STOP input freezes the runtime if the time sequence is active. In all other operating states the input with pulse length < 3 s has no effect. A high pulse with minimum length 3 seconds at the STOP input in each operating case causes resetting of the time sequence with the following consequence: Cancellation of the time sequence and updating of the runtime display with the preset target runtime All outputs switched to the initial state Switching off the status LED Page 4

- Time changeover input Loading of the time changeover input with a high signal results in changeover to the second time range not preselected at the coding switch for the duration of the signal.! If the time sequence is active the time sequence is continued to the end with the time base existing at the start time. Set times are deleted on changing over. Behaviour on failure of the power supply The system monitors the level of the secondary voltage of the power adapter. If it falls below a defined minimum voltage, all loads in the system (displays, outputs, etc) are switched off and the time and switched status of the flare TIME relay is saved in the EEPROM. Saving the time and switched status requires the remanence DIP switch to be set to ON. If the voltage returns the time status (response time and (remaining) runtime) of the flaretime relay before the failure is restored. If the relay was in the active time sequence the remaining time is restored and the relay is placed in the pause state. In this case the operator can deliberately continue the time sequence or reset the relay and start a new time sequence. Time switch diagrams - Overview of the time functions Figure 7: Overview of unclocked time functions Page 5

Figure 8: Overview of the clocked time functions - Time functions in detail Figure 9: Operate delay function setting Page 6

Figure 10: Passing make contact function setting Figure 11: Release delay function setting Page 7

Figure 12: Passing break contact function setting Figure 13: Clock pulse generator starting with pause function setting Page 8

Figure 14: Clock pulse generator starting with pulse function setting EMC/Climate/Shock tests Apart from the basic tests to maintain conformity with the EN 61812-1 standard, the following tests are performed by external service providers on behalf of EAW. - Basic insulation, 2kV, 1.2/50µs, not in operation, preloading 96h 40 C, 90-95% humidity - Insulation resistance measurement, 500VDC, 1 min, >=20MOhm, not in operation, preloading 96h 40 C, 90-95% humidity - Static discharge, 8 kv air or 4 kv contacting, not in operation - High-frequency electromagnetic fields, 10 V/m 80.0 MHz-1.0 GHz, 10 V/m 1.4 MHz-2.0 GHz, 3 V/m 2.0 MHz-2.7 GHz, in operation - Magnetic fields 30 A/m, in operation - Burst 2 kv / 5/50ns, 5 khz (contacts), 1 kv / 5/50ns, 5 khz (control connections), in operation - Surge 1 kv line to line, 2 kv line to PE (contacts), 2 kv line to PE (control connections), in operation - conducted disturbance 10V 150 khz 80 MHz, in operation - noise radiation, 30-230 MHz 40 dbµv 10 m, 230 MHz-1.0 GHz 47 dbµv 10 m, in operation - Single shock, half-sine 15 g / 11 ms, in operation - Vibration, 5 150 Hz, 3.5 mm, 1 g, in operation - Dry heat, storage, 55 C +/-2K, 48:00h, not in operation - Damp heat, steady state, 25 C +/-2K, 93% +/-2% rh, 48h, not in operation - Damp heat, cyclical, 25 C/55 C, 95% rh, 2x24h, not in operation Types / Options - Manual Start/Stop/ using separate button or using the push function of the incremental encoder - Operating instructions as data matrix code for type without separate button - Supply voltage range 18-36VDC Page 9