IF-80x Outdoor Terminal

Similar documents
Access Terminal IF-800

1 IF-810 or IF-811 Terminal (Slave) 2 Intended Use. 3 Assembly and Installation _V IF-810/IF-811

1 IF-812 or IF-815 Terminal (Slave) 2 Intended Use. 3 Assembly and Installation _V IF-812/IF-815

Zeiterfassungs- und Zutrittsterminal IF-57xx

Technical Manual - Part 2

GAT NET.Controller 7000 Control unit for the GAT NET.Lock 7000

Switched Mode Power Supply Operating manual PAP800

ADC7520 SERIES. 1600W Battery Chargers and Power Supplies

Product Details. Contents. Features and Mounting Options for SUNNY STRING-MONITOR SSM24-11

MC 11 EB-2 Power supply cabinet with external bus, AC version

Interflex operates as part of Allegion plc. For more information on Allegion, please visit

Interflex operates as part of Allegion plc. For more information on Allegion, please visit

DXTH DUCT SENSOR / SWITCH FOR TEMPERATURE AND HUMIDITY. Mounting and operating instructions

Safety Switching Devices SNO 4003K. Basic device for Emergency-Stop and Safety Gate Applications PI E

RST ROOM TEMPERATURE TRANSMITTER. Mounting and operating instructions

BMF400 Input/output module

QXA2000 QXA2001. Condensation Monitor QXA2001 QXA2000 AQX2000

RTT2 ROOM TEMPERATURE SWITCH. Mounting and operating instructions

Single Door Standalone Access Control User Manual

RXTP ROOM TEMPERATURE

USER MANUAL. Longo programmable controller LPC-2.ID2 RFID Card holder. Version 8

RТTH DUAL ROOM SWITCH

Expansion Module HZS 541-1S

Operating and mounting instructions

Operating instructions. Standstill monitor A / / 2011

RXTH DUAL ROOM SENSOR / SWITCH

sonnen Installation Practical

SINAMICS G130. Terminal Module 150 (TM150) Operating Instructions 03/2013 SINAMICS

BMCS CCX Cabinet. BMCS_CCX Cabinet is secured via a switchable 6A circuit breaker. Note the right selectivity ratio of your feeding.

200 VA bis VA 10 V bis 80 V 2 A bis 320 A. Source-Sink NL

MU110-6U. Analog output module 6 channel. User guide

User Manual. Item no.: Otto Graf GmbH Carl-Zeiss-Str. 2-6 Tel.: +49(0) Kunststofferzeugnisse D Teningen Fax: +49(0)

RCN420-B Room controller

RAD-DOR4-IFS. I/O extension module, 4 digital relay outputs. INTERFACE Data sheet. 1 Description

Installation manual plugs and connectors with screw connection (16/32 A)

Standalone Keypad Access Control. User Manual. SS-TS2000 Size:120*80*25 mm

Power supply module, bus connection module

PHOENIX CONTACT - 01/2008

I/O module (Expansion module)

RAD-DO8-IFS. I/O extension module, eight digital transistor outputs. Data sheet. 1 Description

Display Panel BAT 100 LSN. en Operation Guide

Controlesta RCO-Compact

Assembly Instructions scancontrol 2700/2750 (500)

RXM39.1. PL-Link IO Block. Desigo TRA. Use with PXC3 series room automation station

CV-110SPK Standalone Keypad/Prox Access Control Installation Instructions

BreezeMAX Wi² and BreezeACCESS Wi² Quick Installation Guide

CM-110SK Standalone Keypad Installation Instructions

Nokeval. FD100 series. User Manual

TEC100 USER/INSTALLER MANUAL V2.0 REV. 03/2018

Network nodes with gateway

TCNM-ACBB1 Installation Manual

PSR-SCP- 24DC/URM4/4X1/2X2/B PSR-SPP- 24DC/URM4/4X1/2X2/B

Supplementary operating instructions for your air curtain system Controller TMC 500

Standalone Keypad Access Control. User Manual. Please read the manual carefully before use this unit

Elo-1145-MSS-Zentraleinheit 471 M41 H31.book Page 1 Tuesday, September 6, :10 PM, Datum:

DESIGO RX Individual room controllers. for fan-coil systems, chilled ceilings and radiators, with LONMARK-compatible bus communications

INSTALLATION INSTRUCTIONS

PHOENIX CONTACT - 05/2007

PHOENIX CONTACT - 06/2007. DANGER OF EXPLOSION! Remove an item only when it is not connected to power or if it is located in the non-explosive area.

XDBKITS5 Bus / DB Terminal Kit (Size 5) Installation Manual DPD00116

CMU 100 RS485 to 7x, 6x, 5x, 4x Multimode Fiber Optic Star Coupler User Manual

PI-EX-ME-2NAM/COC-120VAC

Industriefunkuhren. Technical Manual. Signal Converter. for DIN Rail Mounting Series 4800xx-yy ENGLISH

9.5 nominal torque 4.5 W 16 VA. Min. 30 nominal voltage Min. 30 Nm. Reversible with switch By mounting. MIN (minimum position)

1 Safety instructions. 2 Device components. 3 Function. Smart Control IP. Art. No. SC 1000 IP. Operating instructions

M-bus web server. Meters and Energy Cost Allocation WTV676-HB6035

Operating and Installation Manual. EASYLAB Expansion modules Type EM-TRF for 230 V AC mains voltage

6173 AG GJB A0138

ALPHA SIMBOX Small Distribution Boards

Overview of types. Technical data

OBELUX MID SERIES. Medium-intensity aviation obstruction light. Manual - Obelux MID series. Version 1.4

2M IR Mini Dome Quick Installation Guide

PHOENIX CONTACT - 08/2009. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.

Accessories for stand-alone gird inverter SMART LOAD 6000

USER MANUAL VIBRATION CONTROL RMA-POWER-BOX 107/230

Control unit SG-EFS 104/4L. EN Operating instructions. Innovative by tradition. Version SG-EFS 104/4L AC/DC 24 V

OT EASY 60 II. LED control unit Operating instructions

MAXIMA + Series ROTARY LEVEL CONTROL

English. Operating manual. Universal transmitter UT125. Save for later reference. Companies / brands of GHM

RMZ782B RMZ783B. Extension Modules. Building Technologies HVAC Products. Synco 700. for heating controller RMH760B

ETD-BL-1T-230(-PT) Multifunctional time relay with various functions and adjustable times. Data sheet. 1 Description

Interface Relay CRINT-1x

VR 71. Installation instructions. Installation instructions. For the competent person GB, IE. Publisher/manufacturer Vaillant GmbH

Operating Instructions VEGAMET 381

Phone: Fax: Web: -

TruPortal Dual Door Interface Module Quick Reference

Structure of the device. Push-button sensor module. Ref.-no.: 4008 TSM Safety instructions

Electromotoric actuators

The sensor fulfills the specifications of the EMC requirements, if the instructions in the manual are followed.

STEP-PS/1AC/24DC/1.75

IPassan Installation guide

POE084824B. PoE 54V/8x0,3A/4x7Ah PoE buffer power supply for up to 8 IP camera. v.1.1 EN* Edition: 7 from

SAFETY RELAY YRB-4EML-31S MAIN FEATURES

Documentation KL channel Digital Output Terminal, 24 V DC, 2 x 4 A/1 x 8 A. Version: Date:

Emergency power supply NV2.1-12iaE

Safegard V4 Panel. Installation Datasheet. Safegard V4 Panel Installation Instructions and Datasheet release 1.7 August 2016

Waterproof. Keypad/Reader/Controller

Product and Applications Description. Application Programs. Note. instabus EIB Technical Product Information. June 2005

Demonstration Case BENNING DB 1

User Manual HMI Linkbox HL01 DP/MPI

Transcription:

95-10330_IF-800 V2016-10-20 Outdoor Terminal IF-80x Outdoor Terminal 1 IF-800 Outdoor / IF-801 We are pleased that you have decided to use a terminal of the IF-80x series for recording access data. Scope of delivery: IF-80x terminal (slave) I/O controller board for controlling locking devices Material for fastening 8-pin terminal strip Blue wire for grounding the back panel Mortise lock Plastic strips for sealing the mortise lock Please check the completeness and condition of the shipment upon receipt. 2 Function of the IF-80x Terminal Terminals of the IF-80x series are part of an access control system. They are preferably installed directly next to locking devices. They are generally connected to a master terminal, access manager or terminal controller via an RS485 data cable. These terminals are designed for controlling the access of persons, who identify themselves with RFID credentials, as well as for controlling and monitoring locking devices. We recommend: installing a separate, fuse-protected circuit. keeping a minimum distance of 30 cm between the terminal and other systems with RFID readers. keeping a distance of 10 cm between connecting cables and power lines. 3 Danger Due to Electric Current Electric shock can cause severe injuries or death. De-energize the device. Please observe the accident prevention regulations and take all precautionary measures to ensure the safe installation of the devices. Connection to power supply voltage and initial operation may therefore only be carried out by people trained in electrical engineering. The electrical installation, in which the device is to be operated, must comply with national standards. To guarantee trouble-free operation, we recommend carrying out the electrical installation according to the principles of a TN-S system, which means using separate neutral and grounding conductors. Secure the power cable with a strain relief. The device must be equipped with an external separator to ensure that the device can be de-energized. The device must be equipped with an external fuse protection with a maximum nominal current of 16 A. Interflex Datensysteme GmbH 1/13

4 Intended Use Terminals of the IF-80x series are designed for controlling access as well as for controlling and monitoring locking devices. Any other use is not in accordance with the intended purpose and is therefore not permitted. 5 Shielded Cables To guarantee trouble-free operation, we recommend the use of shielded cables. Operation, however, is also possible with unshielded cables. Data transfer problems must be examined on a case-by-case basis. Where necessary, a shielded cable must be used for the corresponding devices. 6 Assembly and Installation Please carry out all of the following steps in sequence: Install all cables. Mount the IF-80x terminal. Make the electrical connections and switch on the power. Adjust the reader. Set the hardware address. Start initial operation and test. 6.1 Laying the Cables 1 Power supply to mounting rail power supply unit (41-10106) 4 Ethernet data cable from switch to IF-4070 controller or IF-5735 terminal. Cable length maximum 100 m. Power is supplied to the master terminal shown here via PoE or from an external power supply unit. 2 Power supply to I/O controller board 5 Data cable from the I/O controller board to the IF-80x terminal 3 Patch cable from PC to switch or hub 6 RS485 data cable from an IF-4070 controller to an I/O controller board Please refer to the table "Function of Cables and Cable Types" for detailed information on the cable lengths, cable types and their diameters. Interflex Datensysteme GmbH 2/13

6.2 Connecting the I/O Controller Board 1 Cable to IF-80x terminal 5 RS485 data cable 2 Address switch 6 Control line with 2 floating inputs and 1 relay output. Max. switching power: 30 V, 2 A 3 Here, the power supply is connected with one line pair each. 4 Cable to power supply. Connection voltage: 18 to max. 24 V AC/DC 7 Relay output. Here, the cable is connected with one line pair each. 8 Functional grounding and shield are connected to a terminal together. Since the cable run to the IF-80x terminal is usually very long, we recommend connecting the power supply and the relay contact with one cable pair each. 6.3 Function of the Cables and Cable Types Function of Cable Max. Length Recommended Cable Type 1 230 VAC power supply to 20 VAC, 1.5 A power transformer (order no. 41-10106) NYM 3 x 1.5 mm² 2 Low-voltage cable J-Y(ST) Y 4x2x 0.6 mm 3 Ethernet/patch cable from server to switch/hub max. 100 m Category 5 4 Ethernet/patch cable from switch/hub to controller/master terminal 5 Shielded cable from IF-80x terminal to controller/master terminal max. 100 m Category 5 max. 100 m J-Y(ST) Y 4x2x 0.6 mm 6 RS485 bus cable max. 1200 m J-Y(ST) Y 4x2x 0.6 mm Interflex Datensysteme GmbH 3/13

6.4 I/O Expansion If more than 2 inputs or more than 1 relay is required, you can connect a second I/O controller board (order no. 75-500-0141). Please consider the following when planning a second I/O controller board: For technical reasons, the length of the COM cable is limited to 100 m. Reduce the length of the COM cable to ensure that a total length of 100 m is not exceeded. Example: The IF-80x terminal is connected to the I/O controller board 1 via a 30-meter-long cable. Then, the cable for the connection to I/O controller board 2 may only have a length of 70 m. In the example, bridge (1) on I/O controller board 2 must be removed. 6.5 Please Perform the Following Steps in the Specified Order 1. Strip approx. 8 cm of the data cable. 2. Wrap the drain wire (6) around the end of the insulation of the data cable. 3. Feed the connection cable through the strain relief. 4. Install the strain relief in such a way that the end of the insulation with the drain wire is electrically connected to the back panel of the housing (10). 5. Clamp the blue wire under a nut of the strain relief (12). 6. Now, connect all of the cables coming from the I/O controller board to the terminal strip of the IF-800 Outdoor/IF-801 terminal. 7. Then, connect the blue wire from the back panel of the housing to the PE terminal. 8. Connect the terminal strip to the IF-800 Outdoor/IF-801 terminal. 9. Attach the IF-800 Outdoor/IF-801 terminal to the top and press it down until it rests against the wall. 10. Screw down the IF-800 Outdoor/IF-801 terminal on the bottom left side (11) using the M2x6 countersunk screw included in the delivery. 11. Insert the mortise lock on the bottom right side and lock the IF-800 Outdoor/IF-801 terminal (13). 12. Use the enclosed plastic strips to seal the mortise lock. Interflex Datensysteme GmbH 4/13

6.5.1 Mounting the IF-800 Outdoor/IF-801 Terminal Recommendation: Install the terminal at a height of approx. 125 cm (distance from floor to bottom edge of the terminal). 1 Mounting holes 5 Vertical mounting option with DIN appliance case 2 Alternative mounting hole for wall-mounted cable inserted from the bottom 6 Mounting holes for US standard 3 Cable gland 7 Hole for adjusting the reader 4 Horizontal mounting option with DIN appliance case 8 Foam rubber Interflex Datensysteme GmbH 5/13

6.5.2 Fastening the Back Panel of the Housing Using an Appliance Case Using a level, fasten the back panel of the housing by installing the 3 screws included in delivery in the holes marked (1). If the cable is to be inserted from the bottom, use mounting hole (2) instead of the bottom mounting hole (1). Depending on how the appliance case is installed, you can additionally secure the back panel of the housing by installing screws in the two horizontal (4) or vertical (5) holes. For further steps, please refer to: Attaching the IF-800 Outdoor/IF-801 Terminal. 6 This is how the drain wire is wrapped around the insulation. 7 The blue wire is connected to the strain relief. 9 Terminal strip 8 The blue wire and the PE wire from the I/O controller board are connected to terminal 8 on the terminal strip. Interflex Datensysteme GmbH 6/13

6.5.3 Fastening the Back Panel of the Housing with Cable Feed from the Bottom Using a level, screw in the back panel of the housing by installing 2 screws in the holes marked (1). In addition, secure the back panel of the housing by installing a screw in the bottom left hole (2). For further steps, please refer to: Attaching the IF-800 Outdoor/IF-801 Terminal 10 The drain wire must have an electrical connection to the back panel of the housing. 11 Lug for fastening the wall reader with the M2x6 mm screw 12 The cable lug of the blue wire is connected to the strain relief. 13 Lug for mortise lock 6.6 Important Points to Note Regarding the Mounting Please observe the following when mounting the terminal: Do not make any changes to the back panel. Fastening elements in other places can collide with the circuit board. Interflex Datensysteme GmbH 7/13

Check for any unevenness in the panel. The back panel of the device must be level and flush with the wall. Mechanical stresses can damage the device. Use only the original screws and do not use any washers. Screws placed too high can cause collisions with other components and damage the device. Ensure short cable routing. Cable loops can damage the device due to mechanical stresses. Tighten the screw only slightly or leave it out. Tightening the screw too tightly can result in mechanical stresses which can damage the device. Interflex Datensysteme GmbH 8/13

6.7 Electrical Connections 1 IF-80x terminal 5 Circuit example: Control of an actuator (door opener). The actuator may only be operated with max. 30 V and 2 A. 2 I/O controller board 6 Circuit example: Connection of both inputs. 3 Circuit example: Power Supply 7 Address switch on the I/O controller board 4 Circuit example: RS485 connection. The spur line may not be longer than max. 100 m. Bridges: BR1: When an I/O controller board is used, bridge 1 is always plugged in. If an additional I/O controller board is used, bridge 1 on the second I/O control board must be removed. BR2: With bridge 2, the switching contacts of the relay are changed from NO to NC. BR3: Instead of bridge 3, an anti-tamper switch can be connected. Interflex Datensysteme GmbH 9/13

6.8 Adjusting the Reader Structural conditions may make it necessary to fine-tune or readjust the reader. For this purpose, there is a hole (10) on the back panel of the housing. Adjust the reader while the back panel is attached. 1 Anti-tamper switch 3 Adjusting screw for readjusting the reader 2 Terminal clamps 4 2-pin DIP switch for setting the LEDs Switch on the power supply and adjust the reader using the adjustment set (order no. 75-99-0004). Turn the adjusting screw (3) until the field indicator reaches maximum. Setting the LEDs You can use the 2-button DIP switch (4) to set the LEDs according to the color of the display. The switch setting is usually factory preset. Check the setting of the DIP switches by referring to the table. Design 1 /white 2 /blue Glass, white OFF ON Glass, black ON ON Other settings are reserved for additional designs. 6.9 Setting the Hardware Address Switch 1 2 3 4 Address 1 OFF OFF OFF OFF (not required if connected to a master terminal) Address 2 ON OFF OFF OFF Address 3 OFF ON OFF OFF Address 4 ON ON OFF OFF Address 5 OFF OFF ON OFF Address 6 ON OFF ON OFF Address 7 OFF ON ON OFF Address 8 ON ON ON OFF There is a four-way DIP switch on the I/O controller board for setting the hardware address. Interflex Datensysteme GmbH 10/13

6.10 Setting the Address without an I/O Controller Board The address of the IF-80x terminal is set via the RS485 data cable when an I/O controller board without an address switch is used. Once the terminal is connected to the controller, it responds with host address 8. Set the address of the terminal with a Telnet connection via the controller as follows: Set up the connection to the controller with Telnet. 1. Use the command cfg to retrieve the terminal number. Example: cfg -> address 8 has been set. Enter the command: etp <address> -cx The controller responds with TC-->ET(8)= Then, the command 34xxyy is sent directly to the terminal. Example: Address 1: xx = New address A (uppercase) corresponds to 41(Hex) xx = New address a (lowercase) corresponds to 61(Hex) The command for setting address 1 is: 344161 Correspondingly for address 2: 344262 (see table). Via a warm boot (command 55), the terminal then recognizes its new address. After approximately 10 seconds, the terminal is ready for operation and can be checked via the cfg command. Make sure that an address is not used twice. The address must be within the address range of the controller (IF-4070). Interflex Datensysteme GmbH 11/13

This table applies to a controller with 8 possible terminals on bus 1. Old Address Old HA Controller Command Command New Address New HA Bus H 8 etp 8 -cx 344161 A 1 1 H 8 etp 8 -cx 344262 B 2 1 H 8 etp 8 -cx 344363 C 3 1 H 8 etp 8 -cx 344565 E 5 1... 8 etp 8 -cx........... A 1 etp 1 -cx 344868 H 8 1 A 9 etp 9 -cx 344262 B 2 2 7 Initial Operation Once you have connected the IF-80x terminal and set the address, lock it using the mortise lock and screw it down with the M2x6 countersunk screw included in delivery. Define the terminal in your time & attendance/access control software, e.g. IF-6020 or IF-6040. Check the device using a Mifare or LEGIC credential (depending on the order). Interflex Datensysteme GmbH 12/13

8 Technical Specifications Technical Specifications Power Supply Power consumption Protection Interfaces Reader Sensor inputs Outputs User information 12-24 V AC /DC Max. 4 VA Via PTC resistor RS485, 9600/19200 baud (automatic recognition) MIFARE or LEGIC Advant, depending on the order. 2 Floating sensors 1 relay with floating NO/NC contact. Max. switching capacity 30 V, 2 A Buzzer; green/red LEDs and, depending on the display color, blue or white General Data Ambient temperature -25 C to +55 C Humidity Max. 95%, non-condensing Product safety EN 60950-1 Compatibility (EMC) Protection category Degree of protection Dimensions (L x W x D) Weight ETS 300330-1/-2, EN 301489-1/-3, CE III IP54, provided that the cables are installed according to instructions. 130.5 x 87 x 24 mm 0.32 kg 9 Disposal Once its service life comes to an end, the device must be disposed of properly as electronic waste. The owner can dispose of the device himself or return it to the supplier. Copyright 2016 Version Date: October 31, 2016 Interflex Datensysteme GmbH Zettachring 16, D-70567 Stuttgart, Germany Tel.: +49 (0711) 1322 0 Internet E-Mail: interflex.info@allegion.com Websites: www.interflex.de www.allegion.com Interflex Datensysteme GmbH 13/13