Installation Manual. Alpha 4000 RGB Signs. Before you begin

Similar documents
InView Marquee Message Display

Perle MCR200 Installation Guide

SPECIAL APPLICATION MANUAL PART NUMBER: TNP121UL. Tilt N Plug Jr. Table Top Interconnect Box USER'S GUIDE

PNP415/417 POP 'N PLUG WITH CUSTOM TABLETOP SURFACE USER'S GUIDE

FCC Regulatory Information

LS8000 USER MANUAL. Kitchen Display Station Controller. with Android TM

4170 POS System Installation Guide

Network Camera. Quick Guide DC-B1203X. Powered by

Installation Job Aid for Ethernet Routing Switch 3600 Series

ENCELIUM EXTEND Manager Wiring and installation manual Light is OSRAM

Cube Camera with Fixed Lens Hardware Manual D11, D12. Ver. 2013/05/17

SERIES 4600 Ethernet Visual-Pager Display INSTALLATION and SPECIFICATION GUIDE. Manual No. D Revision Date: 08/2016 Control: 1.

EZ Switch EZ Connect N SMCFS1601/SMCFS2401

DDW36A Advanced Wireless Gateway - Safety and Installation Product Insert. Federal Communications Commission (FCC) Interference Statement

AlphaVision PC Series III

Under the Table Interconnect Solutions

dedicated KVM switch and rackmount screen technology User Manual CV-1201D DVI-D KVM Designed and manufactured by Austin Hughes

MONOPRICE. Blackbird 4x4 HDMI Matrix/Extender with 4 Receivers. User's Manual P/N 21905

AUD-340 Installation Guide

Product Documentation

Fixed Network Camera Hardware User Manual

Welcome. Touch 1 (844) LIGHTCLOUD

Polycom RealPresence Video Protect 500

CNK600 Cable-Nook Interconnect Box

MC 11 EB-2 Power supply cabinet with external bus, AC version

ClearCube F6151 Media Converter Chassis System with 10/100BaseTX to 100BaseFX Converter

PR3400 Series 1.4Mp USB Cameras Hardware Guide

DVI KVM Switch user manual Model

DP-222Q Color Video Door Phone Manual

INSTRUCTION MANUAL DISTRIBUTION UNIT. Please read this manual thoroughly before use, and keep it handy for future reference.

DP-222Q Color Video Door Phone Manual

Model DMX24DIM Installation and Operations Manual

User s Manual. LumiVision series. A Designer s X-ray film illuminator. Walnut, CA U.S.A. By LCD TV Technology

Bluetooth Shielding Instructions

Toll Free: Tel: Fax:

PanelView Plus/VersaView CE Terminals and Display Modules

MONOPRICE. ShowPony 12-Watt LED Derby FX Light (RGBW) User's Manual P/N

DC-D4213RX DC-D4213WRX

HDMI and USB KVM Extender

+Cam Quick Start Guide

D12. 1MP Cube with Fixed lens Hardware User s Manual. (PoE) Ver. 2013/05/07

B-33. Hardware and Install Manual. (DC 12V / PoE)

4. 4 x Foot Pads 5. Rack-Mount Kit

Indoor Mini Dome. Hardware Manual D91, D92, E91, E92. Ver. 2013/06/14

DC-V3213XJ-4.3mm DC-V3213XJ-2.5mm

MONOPRICE. Blackbird 4K 2x7 HDBaseT Splitter Kit. User's Manual P/N 24178

Wireless Lighting Control. On/Off. Outdoor Module.

MT /12-Slot Digital MultiTasker

Mercury Helios ASSEMBLY MANUAL & USER GUIDE

USER MANUAL 10 Multi-Touch Panel PC

This simple chassis houses one media-converter module and features an external AC power supply and also a terminal block for DC power input.

MONOPRICE. Blackbird 4K Pro 1x2 Ultra Slim HDMI Splitter. User's Manual P/N 21612

888385_01 Install.book Page 1 Wednesday, November 11, :45 PM. SMDR6 Installation Guide

Models DMX12DIM ELV Installation and Operations Manual

UT UNDER TABLE 4X1 HDMI SWITCHER

Thank you for selecting UTC RETAIL s innovative Model 1170 Point of Sale solution!

Bullet Camera. Hardware Manual E44, E45, E46. Ver. 2014/05/05

Alternative B Type Mid-Span Power Sourcing Equipment. User s Guide

MONOPRICE. Blackbird 4K HDMI 1x8 Splitter/Extender. User's Manual P/N 18787

Megapixel IP D/N Vandal Proof PoE Outdoor Fixed Dome ACM Ver

TRC-190 User s Manual

Juice Mobile Power. Quick Start Guide. ! Stay in touch. Register your product, and find additional accessories at: bretford.com

AUD-220 Installation Guide

Network Camera. Quick Guide DC-T3243HRX. Powered by

*520886* IntelliTouch Pool & Spa Control System MobileTouch Wireless Controller. User s and Installation Guide. P/N Rev A

TFT-LCD VIDEO MONITOR USER MANUAL

The following symbols are used to show dangerous operation or handling. Make sure you understand them before reading the guide.

RS-422/485 to Fiber Industrial Converter

OV-MCR116. Media Converter Chassis System. User s Manual

IP Outdoor Rugged Dome ACM-75x1 series. Ver Hardware User s Manual

User Guide PCT Multi Touch Monitor Display OF17T100-A1-PCT

Satellite INSTALLATION GUIDE

VBAR 270. User Manual. Version 1.2

User Guide TL-SG1024D 24-Port Gigabit Desktop/Rackmount Switch

MONOPRICE. Blackbird 4K 5x1 HDMI Presentation Switch. User's Manual P/N 21906

Network Camera. Quick Guide DC-D1223WX. Powered by

TECHNICAL DATA. V-PIX Quad Bar. Product code CL-VPIX-4-40 Light colour Full spectrum 8 / 480 (see above)

VM2210BE V- MATRIX BASIC ENCLOSURE

ATOM. Instruction Manual. Head. from software version: 8.

Product names mentioned in this manual may be trademarks or registered trademarks of those products and are hereby acknowledged.

QUICK SETUP GUIDE. BCM2 Series Branch Circuit Monitors. Safety Information. Equipment Maintenance and Service. Raritan DANGER!

LVN5200A-R2, rev. 1, Hardware Installation Guide

KRAMER ELECTRONICS LTD. USER MANUAL MODEL: RC-76R/RC-78R Room Controllers. P/N: Rev 5

CLIQ.mini Installation and Setup Guide

Industrial 5-Port Fast Ethernet Switches with SFP Slot and optional 4 PoE PSE Ports. Basic Model: KSD-541 PoE Model: KSD-541-P. Installation Guide

KEYBOARD and MOUSE TO FIBER OPTIC TRANSMITTER USER S GUIDE

Mid-span 802.3af PoE Injector. Installation Guide KPOE-100

USER MANUAL. RC-76R/RC-78R Room Controllers MODEL: P/N: Rev 2

User Guide CPSMP VAC Power Supply Module: PointSystem CPSMC Accessory CPSMC Accessory. Contents.

Network Camera. Quick Guide DC-D3C33HRX. Powered by

210 SERIES WEBSMART NETWORK SWITCHES Quick Start Guide AN-210-SW-F/R-8-POE AN-210-SW-F/R-16-POE AN-210-SW-F/R-24-POE AN-210-SW-F-48-POE

4-port 10/100TX + 1 or 2-port 100FX Industrial Switch. User Manual

AcquiSuite Ally 12 & 48 Advanced Multi-Circuit Meter

MONOPRICE. Blackbird 4K HDBaseT Wall Plate Scaler Transmitter. User's Manual P/N 21816

Owner s Manual. DVI/USB + Audio & Peripheral Sharing KVM Switch

LED Maintenance Instructions

Daily use. indicating that the loud speakers

60W Power over Ethernet Waterproof Adapter PoE IEEE BT Single Port Injector for Outdoor Application

Hypercable injecteur HPOE - Industrial IEEE 802.3at Gigabit PoE Injector. User Manual. v.1.0 Jun Mail :

Transcription:

Installation Manual Alpha 4000 RGB Signs signs are indoor, two-line, full matrix LED displays. These signs can display both text and graphics and can be networked together. Before you begin 1. This manual explains how to physically install your sign. 2. For information about connecting your sign to your network and communicating with your sign, please read the related documentation listed below which can be found at the Adaptive web site http://www.adaptivedisplays.com Document name Part number Description AlphaNET User Manual 97088081 Allows the creation and scheduling of messages for display on signs. Messaging Software User Manual 97010202 Basic sign messaging with a PC. ActiveX Developer s Reference 97092054 Explains how to use the Alpha ActiveX Marquee Control software. Alpha Sign Communications Protocol 97088061 Used to create custom messaging solutions. 3. Determine your network connection: Wireless network + Requires Wi-Fi kit. Uses Ethernet for communication and USB for power. Wired network Ethernet or RS485 Located on side of the sign. Access is via the removal panel on the bottom of the sign. Requires hard wiring directly to the sign. 4. Determine how you will mount the sign, either mounted on a wall or hung from a ceiling. Notice: Hardware for attaching to the mounting surface is not included. Hardware and mounting surface must be able to support four times the weight of the sign. See Sign weights and measurements on page 5. 5. AC power requirements maximum 1 amp at 85 264 VAC Notice: Power consumption will vary depending on the display size and content. PN 1777610201 REV. A

Copyright 2016 Adaptive Micro Systems LLC. All rights reserved. Adaptive Micro Systems 7840 North 86th Street Milwaukee, WI 53224 USA 414-357-2020 414-357-2029 (fax) http://www.adaptivedisplays.com Adaptive is a registered trademark of Adaptive Micro Systems. All other brand and product names are trademarks or registered trademarks of their respective companies.

SIGN OVERVIEW Sign Overview A Side view B C Top view D D Back view E F G Bottom view Item Name Description Item Name Description A USB PORT Provides power to Wi-Fi kit (number 1780230101). Can be used to update the display content using a flash drive. E SCREWS Attach wall mounting bracket here. B ETHERNET JACK Ethernet connection to communicate with sign. F REMOVABLE RS485 WIRING PANEL Remove plate to access wiring. Requires hard wiring (factory installed option only). C AUDIO JACK Plug in external speakers here. Speakers will need to have their own power source. G POWER PLUG LOCATION Provides power to the sign. D HANGING HARDWARE LOCATION Attach hanging brackets here. Bracket width can be adjusted with a 1/16 in. hex key (not included). Tighten the 6-32 hex set screw to 10 in-lb. ALPHA 4000 RBG INSTALLATION MANUAL (PN 1777610201 REV. A) 1-3

INSTALLATION Temperature protection The Alpha 4000 RGB sign includes automatic temperature controls to determine when the internal temperature of the sign is too hot to continue normal operation. The temperature controls are based on the internal temperature of the sign, which is influenced by the ambient temperature, the sign's display load, and the duration the sign is on. If the internal temperature rises above the temperature limit, the LED output is forced into a reduced power mode which dims the brightness of the LEDs. If the internal temperature rises above the highest limit, the display will blank to prevent damage to the sign. If the temperature falls below the auto-dimming threshold level, then auto-dimming stops and the LED brightness returns to normal level. EMI compliance This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with installation guidelines, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference, in which case the user will be required to correct the interference at his own expense. WARNING: This is a Class A product. In a domestic environment this product may cause radio interference, in which case the user may be required to take adequate measures. Installation Notice: Sign installation must be performed by qualified personnel. Notice: Any modifications made to the sign housing will void the warranty. Notice: Always disconnect the communication cable before disconnecting the power cord. Environmental requirements Care must be taken to observe these considerations when selecting a location for the sign. Signs: Are for indoor use only and should not be continuously exposed to direct sunlight. Are not designed to be hung in a window. Hanging the sign in a window will void the warranty. Should only be used in an environment where the temperature is between 0 and 50 degrees Celsius (32 and 122 F). Should only be used in an environment where the humidity (non-condensing) does not exceed 95%. Must be connected to an earth-grounded electrical outlet. Must be installed with at least 1 in (2.5 cm) clearance on each end of the case and at least 2 in (5.1 cm) clearance above the case. Reducing electrical noise Adaptive recommends the following to decrease the amount of electrical emissions and noise with the Alpha 4000 RGB signs: Connect the sign to its own branch circuit. Protect the input power source with a circuit breaker rated at no more than 20 amperes. Do not exceed a power load more than 80% of the circuit breaker rating that is used. Route incoming power to assign a path separate from a sign s serial communication wires. Do NOT run the power and communication wires in the same conduit or directly next to one another. Where power and serial communications wires must cross, the intersection should be perpendicular. Shield all serial communication wires. Connect the shield to ground at the controller only. 1-4 ALPHA 4000 RBG INSTALLATION MANUAL (PN 1777610201 REV. A)

INSTALLATION RS485 connection (optional, factory installed only) To connect your sign to your network using an RS485 connection, remove the plate on the bottom of the sign to access the hard wire connections and terminate the network. Adaptive recommends performing these steps before mounting the sign. Remove this plate When an Alpha 4000 RGB sign is on an RS485 network, an End of Line (EOL) terminator is required at the beginning of the RS485 network and at the end of the RS485 network. The beginning of the network can be a device such as an RS232 to RS485 converter or an Alpha 4000 RGB sign. In either case, it must be terminated. The end of the network is typically an Alpha 4000 RGB sign and should also be terminated. Termination on the Alpha 4000 RGB sign is achieved by jumping pin 4 (D-) to pin 5 (term) on the customer interface terminal block on the controller. Notice: The jumper wire is customer supplied. Sign weights and measurements Customer interface terminal block Sign model number Pitch LED rows LED columns LED colors Dimensions Weight (approx) 4080 4120 4160 4200 4240 16 80 16 120 16 160 16 200 16 240 RGB 4096 colors 25.2 x 3.2 x 7.4 (in) 64.0 x 8.1x 18.8 (cm) 37.2 x 3.2 x 7.4 (in) 94.5 x 8.1x 18.8 (cm) 49.2 x 3.2 x 7.4 (in) 126.7 x 8.1x 18.8 (cm) 61.2 x 3.2 x 7.4 (in) 155.4 x 8.1x 18.8 (cm) 73.2 x 3.2 x 7.4 (in) 185.9 x 8.1x 18.8 (cm) 8 (lb) 3.6 (kg) 11 (lb) 5.0 (kg) 14 (lb) 6.4 (kg) 17 (lb) 7.7 (kg) 19 (lb) 8.6 (kg) ALPHA 4000 RBG INSTALLATION MANUAL (PN 1777610201 REV. A) 1-5

INSTALLATION Wall mounting Anti-lift-off bracket. Larger signs will have two brackets. Ceiling mounting Wall mount bracket Cable clips Clear standoff Left ceiling bracket Clear standoff Guidelines Wall-mounting brackets are provided with the sign. Fasteners are supplied to attach the brackets to the sign. Tighten the fasteners to 15 in-lb. Hardware to secure the brackets to the wall will vary based on the type of material (e.g., concrete, brick, wood) and is not included. The hardware for attaching to the mounting surface must be rated for the mounting surface. Do NOT install directly to drywall, plasterboard, or other fragile supports. Hardware for attaching to the mounting surface must be capable of supporting four times the weight of the sign. The wall (or a wall-mounted support system) must be capable of supporting at least four times the weight of the sign. Guidelines Ceiling brackets are provided with the sign. Fasteners are supplied to attach the brackets to the sign. Tighten the provided fasteners to 10 in-lb. Hardware to secure the sign to the ceiling will vary based on the type of ceiling material (e.g., concrete, brick, wood) and is not included. Hanging chains are not included. The hardware for attaching to the mounting surface must be rated for the mounting surface. Do NOT install directly to drywall, plasterboard, or other fragile supports. Hardware for attaching to the mounting surface, including hanging chains, must be capable of supporting four times the weight of the sign. The ceiling (or a ceiling-mounted support system) must be capable of supporting at least four times the weight of the sign. 1-6 ALPHA 4000 RBG INSTALLATION MANUAL (PN 1777610201 REV. A)

START-UP Start-up After installing a sign according to the previous sections, make sure the unit is installed properly by applying power to it. It may take up to 30 seconds for the loading icon to appear. Then, information similar to the following should display on the sign if Alpha Net Player is installed. Sign display ALPHA controller 1199663011 1.2.10 Sign Serial Number JY00000000 Serial Address V 01 Serial 9600 8N1 IP 10.11.11.254 SUBNET 255.255.0.0 Gateway 0.0.0.0 Port 3001 Meaning Software part number including revision and build AMS Product serial number Alpha Protocol Type code character serial address in hexadecimal Serial baud rate data bits parity stop bits Current IP address of sign (default will be listed on the sign) Current SUBNET of sign (default will be listed on the sign) Current Gateway of sign (default will be listed on the sign) Current Sign Port (default will be listed on the sign) The following information should display on the sign if ooh! Media Player is installed: Sign display LNXv1.5.7 10.11.11.254 Meaning Operating system type and version with IP seen below, one octet at a time. Maintenance Notice: Always disconnect the communication cable before disconnecting the power cord. Routine cleaning Use only a soft, lint-free cotton cloth to clean the sign. Do not use soap and water, alcohol, cleaners with alcohol, or any other strong solvent. Service and Repair There are no user serviceable parts in this sign. Contact Adaptive Displays for service and repair information. ALPHA 4000 RBG INSTALLATION MANUAL (PN 1777610201 REV. A) 1-7

PART NUMBER 1777610201 REV. A Adaptive Display Systems 7840 North 86th Street Milwaukee, WI 53224 USA 414.357.2020 www.adaptivedisplays.com