Installation and User Manual. version 1.00 MODWF 2014/53/UE EN : /30/UE EN55022:2010 EN :2005 EN :2007

Similar documents
ENGLISH ENGLISH ENGLISH ENGLISH

ENGLISH ENGLISH ENGLISH ENGLISH. Installation and User Manual. version 1.00 MODWF 2014/53/UE EN :2016

Installation and User Manual version 1.04 TLM8 2014/30/UE EN55022:2010 EN :2005 EN :2007 SYSTEM IDENTIFICATION

Thank you for your purchase USER MANUAL

Multi-Function Smart Indicator User Manual

Pen Drive USB Datalogger!

USER MANUAL FOR GS100/GS1003G

INSTALLATION MANUAL. LC 200 Electronic Overload Guard. Software versione PW0501 R 0.3

Operating Manual UMB ISO Converter ISOCON Order Number: 8160.UISO

Danfoss commercial compressors Secop compressors produced for Danfoss Bluetooth Gateway

USER S MANUAL. PH232Ex1. #1 RS-232 Serial Port to Ethernet, Terminal Server/Client. Doc No: PH232Ex1-UM-001 IPEX. (IP Electronix)

Strain Gauge Converter

Bluetooth TO Serial CONVERTER E-P132-B

Bluetooth to RS-232 Converter. RT-132B Bluetooth Adaptor Operation Manual

BASE LOAD UNLOAD 3 PRODUCTS 6 PRODUCTS 14 PRODUCTS Multiprogram

isma-b-mg-ip User Manual Global Control 5 Sp. z o.o. Poland, Warsaw

WiFi to RS-232 adapter user manual

User Manual Revision English

Operating and Installation Manual. EASYLAB Expansion modules Type EM-TRF for 230 V AC mains voltage

Real/Virtual COM. JetPort Commander

VirtualSCADA VSU-485G USB to RS422/485 Isolated Converter User Manual

Operating Instructions SECUTEST SI /12.10

Serial to Ethernet Converter

T1-transmitter. 4-20mA 0-20mA 0-10V 0-5V +/-5V +/-10V 2014/30/EU EN55022:2010 EN :2005 EN :2007

IP67 VERSION BOX (on request) 8+3 PG9 cable glands-plugs. 8+3 PVC fittings for sheath

T1-CANopen 2014/30/EU EN55022:2010 EN :2005 EN :2007

IDS-141A/181A. Industrial 4-port/8-port slim type serial to Ethernet device server. Features. Introduction. DS-Tool

T1-transmitter. 4-20mA 0-20mA 0-10V 0-5V +/-5V +/-10V 2014/30/EU EN55022:2010 EN :2005 EN :2007

1.03 TLB ETHERNET TCP/IP 2004/108/EC EN55022 EN EN SYSTEM IDENTIFICATION

MXPLC. Compact PLC process station. Summary. Application HVAC control systems, data acquisition, interfacing 3 rd party systems.

PV Remote Unit A 1378 Instruction manual Version 2.1, Code no

DSTHM-2 COMBINED T AND RH DUCT TRANSMITTER. Mounting and operating instructions

F1000 User's Manual. (Version: V1.01)

Features and Benefits. Certifications

M-610 USER MANUAL PLEASE TAKE THE TIME TO READ THESE INSTRUCTIONS BEFORE STARTING TO USE THE SCALES

RTD-NET Installation Instructions

Procon A1M. INSTALLATION MANUAL Version MITSUBISHI ELECTRIC FOR INSTALLERS

RTD-W Installation Instructions

S SENECA. Installation Manual Z-TWS4. Z-PC Line. Web Multifunction Controller Straton / Linux

RXTP ROOM TEMPERATURE

ETHM-2. Ethernet Module. SATEL sp. z o.o. ul. Schuberta Gdańsk POLAND tel

APP 700 Technical Specification

Installation & User Manual

Power TracKer VII. User s Manual 2006 AVID. Multi Mode Reader. Manufactured under one or more of the following Patents:

Vgraph Hardware manual ver Code 114VGRAHWE01. Vgraph CANBUS USER INTERFACE WITH LCD GRAPHIC DISPLAY ENGLISH. HARDWARE MANUAL ver. 1.

Technical Specification & Warranty mypos Europe Ltd. mypos Mini EN

LC-ON THE GO TM Wireless WiFi Adapter P/N 81538

WiFi to RS-232 adapter user manual

DMW. Digital Weighing Meter. Model Number Legend SALIENT FEATURES. Sensing

Druck DPI 620 advanced modular calibrator

Industrial Serial Device Server

Installation & User Manual V2.08

DXTH DUCT SENSOR / SWITCH FOR TEMPERATURE AND HUMIDITY. Mounting and operating instructions

CHAPTER 1. Introduction Introduction 3

Bluetooth to RS-232&RS422/485. EX-9132B/BI Bluetooth Adapter Operation Manual

Adam Equipment ADAM THERMAL PRINTER. (P.N Revision A1, June 2011)

DMT345 and DMT346 Dewpoint Transmitters

RS485 MODBUS Module 6RO

MMT330 Series Moisture and Temperature Transmitters for Oil

TLS. Installation and User Manual version mA 0-20mA 0-10V 0-5V +/-5V +/-10V 2004/108/EC EN55022 EN EN

Size: 84 x 118.4mm * 100P

Digital Sound Level Meter with USB Model:

Operating Guide MODBUS (RTU) Communications Option IM/L150 MOD_2. Level Indicator L150 and L160

INSPECTION TOOL. Inspection Video Camera with Color LCD Monitor. EU Environmental Protection. Model: 8802LE,8803LE. Model: 8802LE,8803LE

RS-232 and IP Router. Vanco Part Number: RS232-IP. Technical Support

Instruction Manual. T3110 T3110L T3110Ex

TLB4 TLM8. ERDE-Elektronik AB - Spikgatan Vellinge TLM8den.

SDM-6RO. Expansion Module 6 relay outputs. Manufactured for

APC100. User Manual.

Bluetooth RS232 Serial Adapter

T1-Profinet-IO. 4-20mA 0-20mA 0-10V 0-5V +/-5V +/-10V 2014/30/EU EN55022:2010 EN :2005 EN :2007

Dual channel temperature logger with two voltage inputs 0-5V Instruction Manual

HDMI Extender over Ethernet, with RS232, POE

UNIVERSAL CURRENT CONVERTER

Technical Specification & Warranty mypos Europe Ltd. mypos Mini Ice EN

User Manual A08. User Manual

Quick Start. Appearance and pin assignments

converter Tel: Fax:

BASE LOAD UNLOAD 3 PRODUCTS 6 PRODUCTS 14 PRODUCTS Multiprogram

Product Manual. USB BAY-4 Port Serial DB- 9 RS-232 Adapter with FTDI Chipset. Coolgear, Inc. Version 1.1 September 2017 Model Number: USBG-BAY4

WI-I/O 9 Multi I/O Units

TVAC25100 TVAC25110 User manual

dedicated KVM switch and rackmount screen technology User Manual CV-801 PS/2 DB-15 KVM Designed and manufactured by Austin Hughes

EM4594 Mini Wifi Repeater with WPS

User Manual version 1.4 PROG DB. DATA STORAGE PROGRAM for W SERIES weight indicators (Options: OPZWUSB_ ; OPZWDATIPC)

SURGE PROTECTION DEVICE RECOMMENDED

Embedded Modbus TCP Module GS11-MT. User Manual REV 1.1. SST Automation.

The LT1300 wall mount load cell indicator is a precision digital indicator for load cell and strain gauge applications.

Interface WI-FI CODE: INTW. v.1.0. Edition: 2 from Supersedes the: 1 from edition

Serial Communications Accessories SITRANS RD200/300. Operating Instructions 05/2013 SITRANS

P USB 2.0 (Type B) Port - Programming - Online monitoring

7. Cleaning and maintenance Disposal What if there are problems? Technical data... 21

INSPECTION CAMERA MODEL NO: CIC2410 OPERATION & SAFETY INSTRUCTIONS PART NO: GC0116

Before Installing a PC software upgrade use Control Panel/Programs/Uninstall to uninstall the existing MULTiLOG2 software.

MGate 5105-MB-EIP Quick Installation Guide

Bluetooth RS-232 Dongle. User s Manual BTS-100

INSPECTION TOOL. Wireless Inspection Camera with Recordable Monitor. EU Environmental Protection. Model: 8802AL, 8803AL. Model: 8802AL, 8803AL

Document Name: User Manual for SC10MK, Modbus RTU to Modbus TCP Converter

UWE-1707 SERIES CONTENTS OPERATION MANUAL ELECTRONIC WEIGHING INDICATOR 1. SPECIFICATIONS 2. INSTALLATION

HD 2013 HD 2013-D AA-26 AA-27

Transcription:

Installation and User Manual version 1.00 MODWF 2014/53/UE EN300 328:2016 2014/30/UE EN55022:2010 EN61000-6-2:2005 EN61000-6-4:2007 SYSTEM IDENTIFICATION Load Cell Systems reserves the right to change specifications without notice. 2018 Web: https://loadcellsys.com Email: sales@loadcellsys.com Phone: 607-426-1467

KEY TO SYMBOLS Below are the symbols used in the manual to draw the reader's attention: Warning! Risk of electrocution. Warning! This operation must be performed by skilled workers. Read the following indications carefully. Further information. GUARANTEE 24 months from the delivery document date. The guarantee covers only defected parts and includes the replacement parts and labour. All shipping and packing costs are paid by the customer. It is possible to have the repair in guarantee on condition that the returned product has not been transformed, damaged or repaired without authorization. No guarantee is applicable on returned products without the original label and/or serial number. No guarantee against misuse. Batteries: LCS provides 1 year guarantee from the date of delivery note, against material defects or battery manufacturing faults. Disposal of Waste Equipment by Users in Private Households in the European Union This symbol on the product or on its packaging indicates that this product must not be disposed of with your other household waste. It is your responsibility to dispose of your waste equipment by handing it over to a designated collection point for the recycling of waste electrical and electronic equipment. The separate collection and recycling of your waste equipment at the time of disposal will help preserve natural resources and protect human health and the environment. For more information about where you can drop off your waste equipment for recycling, please contact your local waste disposal Authority or the equipment retailer.

TABLE OF CONTENTS USER WARNINGS... 1 MAIN SPECIFICATIONS OF THE INSTRUMENT... 1 TECHNICAL SPECIFICATIONS... 1 ELECTRICAL CONNECTIONS... 2 WIRING DIAGRAM... 2 LED AND KEY FUNCTION... 3 MENU MAP... 3 SYSTEM PARAMETERS... 3 INSTRUMENT COMMISSIONING... 4 PROGRAMMING OF SYSTEM PARAMETERS... 4 WIFI COMMUNICATION SETTING... 4 SERIAL COMMUNICATION SETTING... 9 RS232 SERIAL COMMUNICATION...9 RS485 SERIAL COMMUNICATION...9 CONNECTION TO PC BY VIRTUAL WIFI/ETHERNET PORT... 10 ENERGY SAVING... 11 ALARMS AND MESSAGES CONCERNING THE WIFI MODULE... 11 OPTIONS... 12 OPZBATTWF: INTERNAL BATTERY... 12 BATEXT: EXTERNAL BATTERY... 13 CONNECTING THE BATTERY TO THE INSTRUMENT... 13 OPZWFIP67: IP67 VERSION... 13 RESERVED FOR THE INSTALLER... 14 KEYPAD OR DISPLAY LOCKING... 14

USER WARNINGS RECOMMENDATIONS FOR THE PROPER USE OF WEIGHING INSTRUMENT - Keep away from heat sources and direct sunlight - Repair the instrument from rain (except special IP versions) - Do not wash with water jets (except special IP versions) - Do not dip in water - Do not spill liquid on the instrument - Do not use solvents to clean the instrument - Do not install in areas subject to explosion hazard (except special Atex versions) MAIN SPECIFICATIONS OF THE INSTRUMENT WiFi/serial transceiver. Protection rating IP65 (optional: IP67). Dimensions: 170x80x65 mm; four fixing holes Ø 4 mm (centre distance 120x60 mm). Backlit alphanumeric LCD display, 38x16 mm viewing area, two-line by eight-digit (5 mm height). Six indicator LEDs. 4 key membrane keypad. Two serial ports (RS485 and RS232) for connection to PC/PLC up to 32 instruments (max 99 with line repeaters) by LAUMAS and Modbus RTU protocols. WiFi connectivity: allows the Wi-Fi communication between two serial devices. The MODWF can communicate in a bidirectional way with: - Existing WiFi networks. - Other MODWF instruments. - Other Load Cell Systems instruments equipped with WiFi communication. TECHNICAL SPECIFICATIONS POWER SUPPLY and CONSUMPTION 12/24 VDC ±10%; 1 W SERIAL PORTS RS485, RS232 BAUD RATE 2400, 4800, 9600, 19200, 38400, 115200 WIRELESS WiFi module with serial protocols in tunnel mode RANGE about 100 meters line of sight HUMIDITY (non condensing) 85% STORAGE TEMPERATURE -30 C +80 C WORKING TEMPERATURE -20 C +60 C - 1 -

RS485 RS485 GND VDC RS232 TXD RS232 RXD GND - + ELECTRICAL CONNECTIONS TERMINAL 1 GND 2 +SUPPLY (12/24 VDC) 3 RS232: TXD 4 RS232: RXD 5 GND 6 RS485-7 RS485 + WIRING DIAGRAM 1 2 3 4 5 6 7 12/24 VDC supply - 2 -

LED AND KEY FUNCTION LED 1 reception by RS232 port 2 reception by RS485 port 3 reception by WiFi network 4 transmission by RS232 port 5 transmission by RS485 port 6 transmission by WiFi network Function KEY Function Cancel or return to previous menu Select figure to be modified or go to previous menu item. Modify selected figure or go to next menu item Confirm or enter in submenu Into menus LEDs light up in sequence to indicate that it is not displaying a weight. MENU MAP Into menus changes are applied right after pressing the ENTER key (no further confirmation is required). SYSTEM PARAMETERS + - 3 -

INSTRUMENT COMMISSIONING Upon switch-on, the display shows in sequence: - instrument model (e.g.: ); - followed by the software code (e.g.: ); - program type: (base); - followed by the software version (e.g.: ); - followed by the hardware code (e.g.: ); - serial number (e.g.: ); Setting the parameters related to: - serial communication (see section SERIAL COMMUNICATION SETTING) - WiFi communication (see section WIFI COMMUNICATION SETTING) PROGRAMMING OF SYSTEM PARAMETERS From the weight display, press simultaneously keys MENU and ESC to access the parameter setting. MENU/ENTER: to enter a menu/confirm the data entry. : to modify the displayed figure or menu item. : to select a new figure or modify the displayed menu item. ESC: to cancel and return to the previous menu. WIFI COMMUNICATION SETTING The instrument can operate as access point or client. WARNING: both operating modes (access point and client) use communication port 10001. In point-to-point communication, an instrument configured as access point generates the network to which the instrument configured as client connects itself. If the client is correctly connected to the network, it shows the message LINKED, otherwise it shows the message READY!; the access point always shows the message READY!. When the device connected to the client communicates and the one connected to the access point replies, on both displays the message TX<-->RX appears. - 4 -

For the connection you can use both a web-socket and a virtualization software of the serial ports on ethernet (see section CONNECTION TO PC BY VIRTUAL WIFI/ETHERNET PORT). If the connection to the network fails, make sure that the distance between the instruments does not exceed 100 meters in open air and/or ensure that no shield or noise affect the antennas. It is recommended to place the client instrument in an easily accessible position, in case an operator needs to check any communication problems. OPERATION AS CLIENT connecting the instrument to an existing network + - : enables the operation of the instrument as a client in a CLIENT/SERVER or CLIENT/ACCESS POINT network. - : network name (it must consist of only numbers; e.g.: 123456). - : instrument IP address. - : access point IP address. - : login password of the access point; if no password is required, set 0. Any password must be an 8-digit number that starts with two zeros; e.g.: 00123456 (only the underlined digits can be displayed and modified by the instrument). In order to apply the changes, turn the instrument off, wait for 10 seconds and turn it back on. OPERATION AS ACCSS POINT connecting other devices to the network created by the instrument + - : network name (it must consist of only numbers; e.g.: 123456). - : access point IP address. - : login password of the access point; in order to leave the connection open set 000000. Any password must be an 8-digit number that starts with two zeros; e.g.: 00123456 (only the underlined digits can be displayed and modified by the instrument). In order to apply the changes, turn the instrument off, wait for 10 seconds and turn it back on. - 5 -

EXAMPLES OF COMMUNICATION PARAMETERS SETTING Instrument connection to an existing WiFi network (with password). WiFi network SSID 123456 Access point address (HOST) 192.8.0.1 Password 00123123 Instrument configured as client YES 123456 192.8.0.137 123123 Direct connection (point-to-point) between pc and instrument (without password). Instrument configured as access point NO 654321 192.8.0.1 000000 Pc configured as client SSID 654321 Access point address (HOST) 192.8.0.1 Password - 6 -

Direct connection (point-to-point) between two instruments (with password). Instrument configured as access point NO 654321 192.168.0.4 112233 Instrument configured as client YES 654321 192.168.0.1 192.168.0.4 112233-7 -

Direct connection (point-to-point) via Modbus RTU between instrument and other Load Cell Systems devices equipped with WiFi option (without password). LCS device equipped with WiFi option configured as access point NO 654321 192.168.0.1 000000 MODBUS Instrument configured as client YES 654321 192.167.0.4 192.168.0.1 000000-8 -

RS485 + RS485 - GND RS485 + RS485 - GND RS485 + RS485 - GND - / : communication port. SERIAL COMMUNICATION SETTING + - : it disables any type of communication (default). - : enables the tunnel mode on the selected serial port (communication parameters: data bit: 8, parity bit: none, stop bit: 1). - : transmission speed (2400, 4800, 9600, 19200, 38400, 115200; default: 9600). The communication parameters set on the instruments connected via serial port must be the same. RS232 SERIAL COMMUNICATION INSTRUMENT RS232 TXD RS232 RXD GND 2 3 5 PC DB9-F RS485 SERIAL COMMUNICATION RS485 DEVICE RS485 DEVICE RS485 DEVICE max 500 m WIFI MODWF RS485 + RS485 - GND - 9 -

CONNECTION TO PC BY VIRTUAL WIFI/ETHERNET PORT A PC, by a virtual serial port, can be connected to the MODWF via WiFi. To install the virtual COM port, use the CPR Manager included in the supply: - run the file CPR.exe on the CD; - add a serial port; - set an IP address (host) and a TCP port (10001); - save. Use the just created virtual COM port to communicate with the instrument connected to the MODWF using the selected protocol. Alternatively connect to the MODWF using a socket (e.g.: Winsock) on port 10001. - 10 -

ENERGY SAVING + - : energy saving mode disabled (default). - : the display enters energy saving mode after two minutes of keypad inactivity; by pressing a key normal operations will be restored. - (only if relays are not in use): the display, the WiFi module and the load cells enter energy saving mode after two minutes of keypad, serial ports or WiFi module inactivity; normal operations will be restored by pressing a key or when data are received by the serial ports. The energy saving mode is activated also if an outgoing monodirectional protocol is set. (e.g.: or ). Note: the energy saving options turn off the devices involved. ALARMS AND MESSAGES CONCERNING THE WIFI MODULE The bottom line of the instrument display shows the WiFi module status and the battery option. : : READY!: LINKED: TX<-->RX: the instrument is storing and checking the entered settings; wait until the message has disappeared to proceed. during the settings storage and check some error occurred; verify and enter the last settings again. the instrument is ready to comunicate. the instrument configured as client is connected to the access point. the device connected to the instrument is communicating via WiFi. - 11 -

OPTIONS OPZBATTWF: INTERNAL BATTERY - Battery pack made up of eight 1.2 V NiMH rechargeable elements, type AA, 2450 mah capacity, supplied already installed in the instrument, with dedicated external switch (overall size: 190x80x65 mm). - To achieve maximum battery efficiency, run three full charge/discharge cycles on new batteries and keep working temperature within 45 C. - The battery is automatically recharged every time the instrument is powered by an external 24 VDC power source; a full charge takes about 20 hours. - The instrument is battery powered only when not mains powered. - Battery power supply may be disabled through the dedicated switch. - The bottom line of the instrument display shows the battery status: : charging in progress. : charging finished. : charging problems, replace the battery pack. - Use the functions of the menu to optimize battery lifetime (see section ENERGY SAVING). Mode Maximum operating time (hours) 4 load cells (350 ohm), energy saving: 24 4 load cells (350 ohm), energy saving: 11 4 load cells (350 ohm), energy saving: 10 Approx. maximum operating time for typical use with fully charged battery. - 12 -

BATEXT: EXTERNAL BATTERY - 12 V rechargeable lead battery, 2200 mah capacity, supplied in IP67 box (dimensions: 160x80x85 mm). - The battery is automatically recharged every time the instrument is powered by an external 24 VDC power source; a full charge takes about 8 hours. - The instrument is battery powered only when not mains powered. - Two LEDs inside the IP67 box show the battery status: green LED lit: charging in progress. red LED lit: charging problems, replace the battery pack. Use the functions of the menu to optimize battery lifetime (see section ENERGY SAVING). Mode Maximum operating time (hours) 4 load cells (350 ohm), energy saving: 26 4 load cells (350 ohm), energy saving: 13 4 load cells (350 ohm), energy saving: 12 Approx. maximum operating time for typical use with fully charged battery. CONNECTING THE BATTERY TO THE INSTRUMENT Attach the connector on the left to the instrument and the connector on the right to the power supply. Two flying connectors are supplied for the connections, which must be wired as follow (outer diameter of the cable: 6 10 mm): Male connector Instrument 1 GND 2 +SUPPLY Female connector Power supply 1 GND 2 24 VDC OPZWFIP67: IP67 VERSION The instrument is not equipped with the side hinge; a flying connector is supplied for the power supply, which must be wired as follow (outer diameter of the cable: 6 10 mm): Flying connector Power supply 1 GND 2 24 VDC - 13 -

RESERVED FOR THE INSTALLER KEYPAD OR DISPLAY LOCKING Press ESC immediately followed by hold them down for about 5 seconds (this operation is also possible via the MODBUS and ASCII protocols): - : no lock. - : keypad lock: if active, when a key is pressed the message is displayed for 3 seconds. - : keypad and display lock: if active, the kaypad is locked and the display shows the instrument model; by pressing a key the display shows for 3 seconds. Load Cell Systems reserves the right to change specifications without notice. 2018 Web: https://loadcellsys.com Email: sales@loadcellsys.com Phone: 607-426-1467