PLC HMI. One Integrated Solution for Control & Automation ALL IN ONE. Powerful Software Full Range of PLCs Complete Line of VFDs Outstanding Support

Similar documents
PLC HMI ALL IN ONE. Powerful Software Outstanding Support Complete Range of PLCs

PLC HMI. Powerful Software Outstanding Support Complete Range of PLCs ALL IN ONE

PLC HMI ALL IN ONE. Powerful Software Outstanding Support Complete Range of PLCs

PLC HMI ALL IN ONE. Powerful Software Outstanding Support Complete Range of PLCs

PLC HMI ALL IN ONE. Powerful Software Outstanding Support Complete Range of PLCs

PLC HMI VISION SAMBA JAZZ. Powerful Software Outstanding Support Complete Range of PLCs ALL IN ONE

PLC HMI VISION SAMBA JAZZ. Powerful Software Outstanding Support Complete Range of PLCs ALL IN ONE

PLC HMI. UniStream. Powerful Software Outstanding Support Complete Range of PLCs ALL IN ONE TM

PLC HMI Powerful Software Outstanding Support Complete Range of PLCs ALL IN ONE

PLC + HMI in One Unit

PLC HMI Powerful Software Outstanding Support Complete Range of PLCs ALL IN ONE

350 TM. Features: V350-J Flat Panel. V350 Classic Panel HMI PLC. Communication

PLC HMI ALL IN ONE. Powerful Software Outstanding Support Complete Range of PLCs

1210 TM /1040 TM. Features: V1210 Flat Panel. V1040 Classic Panel HMI PLC. Communication

350 TM. Features: V350-J Flat Panel. V350 Classic Panel HMI PLC. Communication

Jazz-J. Jazz. Features:

Jazz-J. Jazz. Features:

Vision570 TM /560 TM. Color OPLC TM. Color Vision570 TM /560 TM Series Featuring:

Power Supply Input voltage 20.4VDC to 28.8VDC with less than 10% ripple Max. current consumption See Note 1

From single machine automation to wide distributed remote concepts

Wide Ladder Nets Ladder nets are now wide, and reach completely across your PC screen - no empty areas. This gives you twice the editing space

Vision OPLC. Technical Specifications. V T34 Technical Specifications

All Analog Outputs, voltage/current 10mA 35mA 5mA 48mA/30mA* *If the analog outputs are not configured, then subtract the higher value.

All Analog Outputs, voltage/current 20mA 35mA 5mA 48mA/30mA* *If the analog outputs are not configured, then subtract the higher value.

Power Supply Input voltage 20.4VDC to 28.8VDC with less than 10% ripple Max. current consumption See Note 1

Power Supply Input voltage 20.4VDC to 28.8VDC with less than 10% ripple Max. current consumption See Note 1

Power Supply Input voltage 20.4VDC to 28.8VDC with less than 10% ripple Max. current consumption See Note 1

V430J-TR34 V350-TR34 V350J-TR34. pnp inputs

Vision OPLC. Distributed by: M.A. Selmon Company, Inc 4 Oxford Rd. Milford, CT V R34/V350-J-R34 Technical Specifications

V350-T38 V350J-T38.

20.4VDC to 28.8VDC with less than 10% ripple Max. current consumption See Note 1 npn inputs

V350-RA22 V350J-RA22.

Samba OPLC SM35-J-T20

20.4VDC to 28.8VDC with less than 10% ripple Max. current consumption See Note 1

Item SM35-J-TA22 SM43-J-TA22 SM70-J-TA22

V350-RA22 V350J-RA22.


Vision OPLC. V TR6 Technical Specifications. Technical Specifications.

Samba PLC+HMI SM35-J-RA22

Vision OPLC. V T38 Installation Guide. General Description

20.4VDC to 28.8VDC with less than 10% ripple Max. current consumption See Note 1 npn inputs

UniStream. Built-in. Installation Guide: US7-B5-B1, US7-B10-B1, US7-B5-TR22, US7-B10-TR22, US7-B5-T24, US7-B10-T24

This guide provides basic information for Unitronics controllers V C30B and V T40B.

Installation Guide V1210-T20BJ This guide provides basic information for Unitronics controllers V1210-T20BJ.

Vision OPLC V TR20

Vision OPLC V TR20

Item SM35-J-T20 SM43-J-T20 SM70-J-T20

20.4VDC to 28.8VDC with less than 10% ripple. Input impedance 10mSec typical, when used as normal digital inputs

Installation Guide V1210-T20BJ This guide provides basic information for Unitronics controllers V1210-T20BJ.

Distributors News. December, 2004 Unitronics has announced a major market release. The release includes:

1500ct Pump Controller

1500ct Pump Controller

Micro-Modular Programmable Controller

U90 Ladder Software Manual. Version 3.50, 6/03

PLC HMI. UniStream. Powerful Software Outstanding Support Complete Range of PLCs ALL IN ONE

10 x Digital inputs, 24VDC, sink/source 2 x Analog inputs, 0 10V / 0 20mA, 12 bits

PostgreSQL support, in addition to SQL Server and MySQL. UniApps localization for Korean & Italian, plus a new Korean virtual keyboard

U90 Ladder Software Manual

URB Remote IO: occasionally raised compilation errors, although functionality was not affected

This guide provides basic information for Unitronics controller model V T2.

Vision OPLC. General Description. Installation Guide V T34.

V TU24 V350-J-TU24

RENU ELECTRONICS Control, Visualisation and Communications

3 Digital, 3 Digital/Analog, 3 PT1000/NI1000 Inputs, 5 Relay, 1 pnp/npn Outputs

UniLogic UniStream OS , January 2016

VersaMax Micro and Nano Technical Product Presentation

Select a Micro800 Controller

Screen 2.4" 3.5" Color Touch 4.3" Color Touch. RS232/485 Yes Yes Yes* Yes* Yes* USB device, mini-b Com Ports, separate order, user-installed

Micro800 Family of PLCs. Featuring Allen-Bradley Connected Components Workbench Programming and Configuration Software

T29 - New PanelView TM 800 HMI Family

Z-GPRS2-SEAL THE SIMPLEST REMOTE MANAGEMENT SYSTEM FOR UNIVERSAL APPLICATIONS GSM/GPRS DATALOGGER WITH BUILT-IN I/O S AND TELECONTROL FUNCTIONS

Advantages for the MicroLogix 1500 Controller (in addition to MicroLogix 1200 controller features)

JUMO mtron T. Measuring, Control, and Automation System. Features. Brief description. Systembus LAN. Data Sheet Page 1/12. Com1.

This guide provides basic information for Unitronics Models V230/260/280/290 (Non-color Screens).

An HMI for Every Application

Once you have added I/O Expansion Modules to your project, you can create variations called 'IO Module Configurations'.

This guide provides basic information for Unitronics Models V230/260/280/290 (Non-color Screens).

Vision OPLC. General Description.

NEW RELEASE UNILOGIC V UNISTREAM OS

A Next Generation OCS. XL Series OCS

22 Digital Inputs, including 2 Analog, 2 HSC/Shaft-encoder inputs 16 Transistor Outputs

Programmable Logic Controllers

Micro800 PLC Family. Featuring Allen-Bradley Connected Components Workbench Design and Configuration Software

Micro800 Programmable Logic Controller (PLC) Family

NG14R L 24 VDC, 9.6 Watts Max. inclusive of expansion 0.3 µs for Bool Instruction, 0.6 µs for Word Instruction 128 K bytes Flash NG1

ex700 Field Beautiful Power

Intelligent Control Station

USP-070-B08 USP-104-B10, USP-104-M10 USP-156-B10

This document contains 89 FAQ for Brainchild HMI products.

Industrial Control SE-607

UniStream HMI Panel. CPU-for-Panel

If a project set to Samba includes a Socket Init function set to protocol HTTP, a compilation error now results. (Samba does not support web server)

Vision OPLC V TR20/V350-J-TR20

This guide provides basic information for Unitronics Models V230/260/280/290 (Non-color Screens).

Screen 2.4" 3.5" Color Touch 4.3" Color Touch. RS232/485 Yes Yes Yes Yes Yes* USB device, mini-b Com Ports, separate order, user-installed

Advantages for the MicroLogix 1400 Controller

SOFTWARE MANUAL VISILOGIC - GETTING STARTED. V G23 Rev: 3:00

Ver. 01. FnIO S-Series. Integrated Systems for the Speed and Quality

UniStream CPU-for-Panel

UA-5200 IIoT Communication Server

Transcription:

PLC HMI ALL IN ONE One Integrated Solution for Control & Automation Powerful Software Full Range of PLCs Complete Line of s Outstanding Support

About Unitronics Unitronics designs, manufactures, and markets advanced control and automation solutions. Our extensive offering includes a complete line of PLCs with integrated HMI, full line of s, a broad array of I/Os and complementary devices, as well as programming software for all aspects of control, motion, HMI, and communications. Unitronics PLCs range from micro-plc + HMI units for simple machine control, to complex controllers with advanced functions, a variety of onboard IOs and multiple communication options including support for Industry.0 (smart factory) technology. Easy to use, efficient, and affordable, our products have been automating processes, systems and standalone applications since 99. Today, our field-proven products automate hundreds of thousands of installations in diverse fields, including petrochemicals, automotive, food processing, plastics & textiles, energy & environment, water & waste water management anywhere automated processes are required. Unitronics is represented by more than 60 distributors in over 55 countries around the globe, providing our customers with local support in their local languages. UniStream Series Table of Contents Page One Integrated Solution for Control and Automation... UniStream Series...6 UniLogic All-in-One Software... UniStream Modular Features...0 UniStream Built-in Features... UniStream Built-in I/Os... Local I/O Modules...5 Remote I/O Modules via Ethernet...6 Bridge the Gap between OT and IT...7 Unitronics Benefits: Full Product Range: PLC + HMI controllers, I/Os, and s to meet all application needs. All software and utilities are provided at no additional charge All-in-One Software: Configure and program PLC, HMI,, and all other components in one easy environment Industry.0: SNMP, FTP, e-mail, SMS, GPRS/GSM, Remote Access via VNC Client / built-in Webserver, SQL & MQTT Rich Features: Auto-tuned PID, datalogging, Recipes, HMI Trends & Gauges, Alarms, multi-level passwords, multi-language support, Datacom via CANopen, CAN Layer, MODBUS, EtherNetIP and more Outstanding Support: Unitronics exceeds the industry standard for customer care. You benefit from personalized, expert sales and technical support without fees or tiers Customized Solutions: Products tailored-made according to specifications Vision Series Samba Series VisiLogic All-in-One Software... Software Utilities...9 Vision 0 / 00...0 Vision 700... Vision 570 / 560... Vision 0...6 Vision 50... Vision 0...0 Samba... Jazz Series Jazz... I/O Expansion Modules & Accessories: Vision Series...6 Snap-in I/O Modules...7 Variable Frequency Drives Variable Frequency Drives (s)... Specification...9 Product Offering...0 This catalog provides a general overview of Unitronics products. Before you place an order, please check the complete technical specifications for each product, located in the Unitronics website.

One Integrated Solution for Control and Automation Complete Range of PLC+HMI Powerful, Multi-function Controllers Up to 0 I/Os per controller Quality HMI Field-hardened Award-winning Full Range of s Easy to Program Simple to Use Setup & Program via Software or Keypad All-in-One Programming Software Program Ladder Logic Design HMI & Web pages Configure s Hardware & Communication Configuration One Easy Environment Total Solution for Industry.0 MQTT SQL FTP SNMP Built-in Web Server Remote Access via VNC Smart Factory Technology NEW 5

UniStream Series Powerful Award-winning Programmable Logic Controllers For high-end automation projects, available in two All-in-One series: Modular & Built-in. UniStream Modular Create a custom control solution, perfectly matched to your requirements Uniquely designed to enable you to create a customized controller in three steps: select an HMI panel, snap in a CPU, and add any I/O or communication modules necessary for your specific application. UniStream Built-in Space-saving PLC that delivers the functionality to control complex machines PLC+HMI+I/O built into a single, superbly compact unit in a range of built-in I/O configurations. Available in two versions: Built-in and Built-in Pro. Vision TM Series Audio Out Mini USB (Programming) Samba TM Series Jazz Series MicroSD card x USB (Host) Mini USB (Programming) x Ethernet TCP/IP Ethernet TCP/IP USB (Host) MicroSD card Built-in I/Os Built-in speaker CPU I/O & COM Modules I/O Expansion Adaptor CANbus COM Modules RS5 6 7

UniLogic - UniStream All-in-One Programming Software Ultimate All-in-One programming environment: configure hardware & communications, program Ladder, design HMI & web pages, configure & control s and more. Design Beautiful HMI Displays - Stream Video, Audio, PDF UniLogic s extensive free graphics library & HMI widgets enable you to be a graphic artist. The easy HMI editor supports layers, image transparency, overlap, rotation--plus drag & drop widgets, Video & Audio players, Data Tables, Trend graphs & Gauges to display run-time values, and more. New! Configure & Operate... Unitronics s using the same, efficient software Build-it-Once... Reuse Library: Functions, HMI & Webpages Context-sensitive... Toolbox for Ladder, HMI & Web Elements Build-it-Once, then Reuse - the Ultimate Time Saver Add your UDFBs, HMI screens, HMI Custom Controls, and Web Pages to the Library--then drag & drop them where needed; UniLogic takes care of the tags. Import your Library into any project, and share it with others. Languages - from Italian to Chinese at the Touch of a Button UniLogic supports any language that you can type - including Asian languages such as Chinese, Japanese, and Korean. Instantly switch HMI language via user actions or program events. Power from C... Structs & C Functions Built-in Alarms - Easily Boost Application Safety Compliant with ISA. standard guidelines for Alarm Management systems in the process industries. Detect & analyze Alarms, and take action. Export Alarm Logs via FTP to send via email, or copy directly from the controller via DOK. Alarms feature full multi-language support. MQTT Via MQTT, UniStream bridges between the production floor all the way up to the MES. Supports MQTT as a 'client' that can both publish and subscribe to messages. Power Data Tools - Data Sampler, Data Tables, Recipes, SQL Data Samplers record dynamic application data, such as output values, at fixed intervals into files and display it as Trend graphs on the HMI. Data Tables organize and manipulate data via Ladder, create data logs, implement Recipes, import/export values from/to Excel, allow users to enter/edit data into Data Tables via HMI panel, and more. NEW SQL Connector: Access SQL databases, run Queries, connect Data Tables to SQL. Structs - Tag Database on Steroids You create Structs - groups of data tags of different types organized into a single, logical unit - and reuse them across programs, especially with UDFBs (User Defined Function Blocks). UniLogic s built-in Structs enable you to configure and control hardware and complex functions such as Communications and PID. Speed Ladder Programming - plus C Power Build your Ladder: drag & drop elements that snap into place, error-free. Use the built-in C Function editor to write C functions. UniLogic means you write-it-once : create code to use, reuse, and export across projects. Create UDFBs (User Defined Function Blocks) - self-contained functions for tasks such as oven control. Web Server: Web Pages No HMTL Required Design elegant web pages via a drag & drop interface, identical to the HMI editor. A rich graphic library is at your disposal. The Web toolbox offers user controls and widgets, enabling the end user to view and enter application data via any web browser. Communications - Configuration not Programming Incredibly fast, easy to configure and implement, UniStream data communications run independently of Ladder. A single PLC can contain multiple slave definitionsand multiple master definitions. Communicate with any device: plug-and-play protocols such as MODBUS, CANopen, SNMP, MQTT,and EtherNet/IP. Use Message Composer to communicate with devices such as frequency converters and bar-code readers via any Ethernet, CANbus or serial rd -party protocol. Also supports CANLayer, FTP Client/Server, SMS, email, GSM/ GPRS modem. 9

Samba TM Series Vision TM Series UniStream Series Features: HMI Modular Size: 7, 0. or 5.6 High quality color touchscreen. UniStream 0. is also available with Multi-Touch screen Multi-language display Built-in Alarm Screens Media support: Video, Audio and PDF viewer Multi-level password protection easy and fast PLC I/O options include digital, analog, high speed, temperature, and weight measurement Expand locally: up to 0 I/Os Expand remotely: via UniStream Ethernet-based I/O Auto-tune PID, up to 6 independent loops Recipes & data logging via data tables & sampling MicroSD card - log, backup, clone & more Function Blocks & Structs steps to an All-in-One controller: select HMI panel, add the powerful CPU, and snap on any I/O and COM modules. Expands up to 0 I/Os. UniStream 7" UniStream 7 UniStream 0. UniStream 5.6 Article Number USC-P-B0 USP-070-B0/ USP-070-B0 USC-P-B0 USP-0-B0/USP-0-M0 USC-P-B0 USP-56-B0 I/O Options Total supported I/Os 0 (See I/O Expansion Modules- page 5) Onboard I/O modules Fit up to slim or wide I/Os Fit up to 5 slim or wide I/Os I/O Expansion Use Local Expansion Adapters to add up to 0 slim or 50 wide modules Remote I/O via Ethernet Use UniStream Ethernet-based Remote I/O adapters to add I/Os via Ethernet (See I/O Expansion Modules - page 6) Add-on COM modules Supports up to COM modules Supports up to COM modules Program Application Memory HMI Panel Color Touchscreen Resistive, Analog Resistive, Analog / Multi-Touch Resistive, Analog Viewing Area Height x Width (mm) Cut Out Height x Width (mm) USP-070-B0: 5. x 9. USP-070-B0: 5.0 x 5.9 MB. x 5.. x 9.5.0 x 96.0.0 x.0 9.0 x 95.0 Resolution 00 x 0 (WVGA) 00 x 600 (SVGA) 66 x 76 Keys Virtual Keyboard Jazz Series Communication Built-in ports: CANbus Ethernet TCP/IP RS5 USB host Mini USB for programming Add-on ports: Up to RS (Using UAC-0RS) Up to RS + RS5 (Using UAC-0RSC) UniStream 0." Available with Multi-Touch Environment Protection IP66, IP65 and NEMAX when panel-mounted Operating Temperature -0 C to 55 C 0 C to 50 C Standard UL, CE, EAC, UL Hazardous Locations, Class I, Division General Battery Clock years typical at 5 C, battery back-up for memory and RTC Real-time clock functions (date and time) Power Supply /VDC Protocols: MQTT Client EtherNet/IP MODBUS: Serial & TCP/IP CANopen, CANlayer, UniCAN SNMP BACnet, KNX and M-Bus via gateway Message Composer for rd party protocols Local Expansion Adapters UAG-XK5 Short Range Kit, 5 cm UAG-XKP5 Short Range + embedded Power Supply Kit, 5 cm UAG-XK00 Short Range Kit, 00 cm UAG-XKP00 Short Range Kit + embedded Power Supply, 00 cm UAG-XKPLXXXX Long Range + embedded Power Supply, lengths: 600, 00, 500, 000, 000cm Uni-COM Communication Modules UAC-0RS x RS UAC-0RS UAC-0RSC x RS x RS port and x RS5 port General Features: SQL Client Web Server FTP server & client E-mail & SMS Remote access via VNC G Modem support 0 UniStream 5.6" Add-on Modules, I/O and COM: the total number of modules, both I/O and COM that you can snap onboard an HMI panel is limited by the size of the panel. I/O modules are "Slim" &" Wide". Wide I/O module =.5 Slim or COM module. UniStream complies with IP66 and NEMAX only if audio-jack seal is installed. Refer to HMI panel installation guide. V applies to PLC power supply only, and not to the I/O. For a list of relevant models, contact Unitronics

Jazz Series Samba TM Series Vision TM Series UniStream Series Features: HMI Size: 5", 7" High quality color touchscreen Multi-language display Built-in Alarm Screens Media support: Video*, Audio* and PDF viewer Multi-level password protection easy and fast PLC I/O options include digital, analog, high speed, temperature, and weight measurement Expand locally: up to 0 I/Os Expand remotely: via UniStream Ethernet-based I/O Auto-tune PID, up to 6 independent loops Recipes & data logging via data tables & sampling MicroSD card - log, backup, clone & more Function Blocks & Structs Communication Built-in ports: Ethernet TCP/IP USB host Mini USB for programming Built-in Powerful PLC in a superbly compact hardware profile: PLC+HMI+I/Os built into one single unit. Available in two versions: Built-in and Built-in Pro. Expands up to 0 I/Os. UniStream 5" I/O Options UniStream 5 UniStream 7 Total supported I/Os 0 Built-In I/O Expansion Remote I/O via Ethernet According to model (See Built-in I/Os configurations- page ) Add Local I/O via expansion port (See I/O Expansion Modules - page 5) Use UniStream Ethernet-based Remote I/O adapters to add I/Os via Ethernet (See I/O Expansion Modules - page 6) Add-on COM Modules Add up to COM modules Program Application Memory HMI Panel Color Touchscreen Viewing Area Height x Width (mm) Cut Out Height x Width (mm) Resolution Height x Width (mm) Keys Environment Protection MB Resistive, Analog 0 x 6. 9. x. 00 x 0 (WVGA) Virtual Keyboard IP66, IP65 and NEMAX Operating Temperature -0 C to 55 C Add-on ports:** CANbus RS5 RS Protocols: MQTT Client EtherNet/IP MODBUS TCP CANopen, CANlayer, UniCAN SNMP BACnet, KNX and M-Bus via gateway Message Composer for rd party protocols General Features: SQL Client* Web Server* E-mail & SMS Remote access via VNC FTP server & client G Modem support * Pro version only. Model numbers including B5 refer to Built-in, B0 to Built-in Pro. ** Up to serial modules and one CANbus module. UniStream 7" Standard CE, UL, EAC General Battery Clock Local Expansion Adapters UAG-CX-XKP5 UniStream CX IO Exp.Kit.5m UAG-CX-XKP00 UniStream CX IO Exp.Kit m years typical at 5 C, battery back-up for memory and RTC Real-time clock functions (date and time) Uni-COM Communication Modules UAC-CX-0RS Uni-COM: x RS port UAC-CX-0RS Uni-COM: x RS5 port UAC-CX-0CAN Uni-COM: x CANbus port UniStream 5" I/O Expansion: the first unit plugged into the I/O expansion jack must be from the CX series I/O expansion - UAG-CX-XKP5 or UAG-CX-XKP00. The CX end unit may be followed by Uni-I/O modules or UAG-XKPLxxxx adapters. Up to serial modules and one CANbus module. For a list of relevant models, contact Unitronics.

UniStream Built-in I/O Configurations * Article Summary Digital (Isolated) Inputs Operating HSC/Shaftencoder Analog Temperature inputs, RTD/TC Transistor (Isolated) PWM Relay Analog Voltage Expand Locally via Uni-I/O UniStream Modular & Built-in - Expand up to 0 I/O via Uni-I/O modules. Inputs US5-B5-B US5-B0-B US7-B5-B US7-B0-B No built-in I/Os - - - - - - - - /VDC Article Number UID-600 Digital (Isolated) 6 Sink/Source HSC/Shaftencoder Analog Temperature Measurement Transistor 5 (Isolated) PWM/ HSO 5 Relay Analog Jazz Series Samba TM Series Vision TM Series UniStream Series * US5-B5-TR US5-B0-TR US7-B5-TR US7-B0-TR US5-B5-T US5-B0-T US7-B5-T US7-B0-T US5-B5-RA US5-B0-RA US7-B5-RA US7-B0-RA US5-B5-TA0 US5-B0-TA0 US7-B5-TA0 US7-B0-TA0 US5-B5-R US5-B0-R US7-B5-R US7-B0-R US5-B5-T US5-B0-T US7-B5-T US7-B0-T 0 Digital Inputs, Analog Inputs, Transistor,, including PWM. Relay 0 Digital Inputs, Analog Inputs, Transistor,, including PWM Digital Inputs, including HSC, Analog Inputs, Temperature Inputs, Relay, Analog Digita Inputs, including HSC, Analog Inputs, Temperature Inputs, 0 Transistor outputs,, including PWM, Analog Digital Inputs, including HSC, Analog Inputs, relay Digital Inputs, including HSC, Analog Inputs, 6 Transistor,, including PWM 0 Sink/ Source 0 Sink/ Source Sink/ Source Sink/ Source Sink/ Source Sink/ Source - - 90kHz -bit 90kHz -bit 90kHz -bit 90kHz -bit Models R+T, as well as all standard (B5) models will be soon UL certified. Note that the high-speed inputs are included in the total number of digital inputs. Note that the PWM outputs are included in the total number of transistor outputs. 0-0V, 0-0mA, -0mA -bit 0-0V, 0-0mA, -0mA -bit (isolated) 0-0V, 0-0mA, -0mA -bit (isolated) 0-0V, 0-0mA, -0mA -bit 0-0V, 0-0mA, -0mA -bit 0-0V, 0-0mA, -0mA -bit - - (isolated) Thermocouple, PT00/NI00/ NI0/ PT000/NI000 (isolated) Thermocouple, PT00/NI00/ NI0/ PT000/NI000 Sink () Source () 0kHz khz - - 0 Source () khz - VDC - - VDC - 0-0V -bit, ±0V, -bit+sign 0-0mA, -0mA -bit 0-0V -bit, ±0V -bit+sign 0-0mA, -0mA -bit VDC VDC - - - - VDC - 6 Source () khz - - VDC Digital Analog and Temperature Digital/Analog UID-00T Sink/Source 6 UID-W66T Sink/Source UID-00THS Sink/Source 50kHz -bit UID-006T UID-00R Sink/Source 6 UID-W66R Sink/Source Source() 6 Source() Source() 6 Source() 50kHz khz 6 UID-006R 6 UIA-0006 UIA-00N UIA-000N UIA-000NH (coming soon) 0-0V, 0-0mA, -0mA -bit UIS-0PTN UIS-0PTKN UIS-0TC UIS-WCB, 0 Sink/Source UIS-WCB, 0 Sink/Source 0kHz bit 0kHz bit 6 (Isolated) 0-0V -bit, ±0V -bit+sign, 0-0mA, -0mA -bit 0-0V -bit, ±0V -bit+sign, 0-0mA, -0mA -bit 0-0V, 0-0mA, -0mA -bit 0-0mA, -0mA With HART communication PT00/NI00/NI0 PT000/NI000/NI00 (Isolated) Thermocouple (Isolated) 0-0V, 0-0mA, -0mA -bit (Isolated) 0-0V, 0-0mA, -0mA -bit (Isolated) Thermocouple, PT00/NI00/NI0 (Isolated) Thermocouple, PT00/NI00/NI0 6 Sink () Source () 6 Sink() 50kHz 50kHz (Sink outputs only) 0-0V -bit, ±0V -bit+sign, 0-0mA, -0mA -bit 0-0V -bit, ±0V -bit+sign, 0-0mA, -0mA -bit This module utilizes two high speed blocks that can each be assigned either to the inputs or to the outputs. outputs are high-speed, up to 50KHz: function as normal or high-speed PWM (same freq. and different duty-cycles). outputs are normal speed: function as normal-speed PWM outputs (same freq. and same duty cycle). Width: wide I/O module =.5 slim I/O modules Note that the high-speed inputs are included in the total number of digital inputs. 5 Note that the high-speed outputs are included in the total number of digital outputs. 6 Not isolated DIN Rail Power Supplies UAP-VW W V A UAP-V60W 60W V.5A UAP-V96W 96W V A Modems GSM-KIT-7J-G Cinterion GPRS modem, EHS6T, G 5

Remote I/O Ethernet based Up to 6 I/O modules per adapter Slim modules - only mm 6--bit Analog Resolution NEW! From OT to IT Bridge the Gap with series Operating temperature:-0 C to 70 C Remote I/O Adapter UniStream Series Input Modules Article Number Description URB-TCP UniStream Remote IO Ethernet Adapter Article Description Digital HSC/Shaft encoder Analog Temperture Mesurements URD-000 Digital inputs (sink or source), 0RTB - - - URA-000O Analog Current Inputs bit, 0RTB - - - IT FTP SNMP EMAIL SQL MQTT Vision TM Series URA-000O Analog Current Inputs bit, 0RTB - - - URA-000P Analog Voltage Inputs bit, 0RTB - - - URA-000P Analog Voltage Inputs bit, 0RTB - - - URA-000T Analog Current Inputs 6bit, 0RTB - - - Remote Access URA-000U Analog Voltage Inputs 6bit, 0RTB - - - Samba TM Series Jazz Series URS-0TC (Coming soon) Thermocouple, 0RTB - - - URS-0RT (Coming soon) RTD, 0RTB - - - URD-000C (Coming soon) Digital inputs, 0VAC, 0RTB - - - URD-000B (Coming soon) Digital inputs, 0VAC, 0RTB - - - URD-000D (Coming soon) Shaft Encoder, 0RTB - - - URD-000E (Coming soon) High Speed Counter, 0RTB - - - Output Modules Article Description Transistor Relay Analog URD-000RH Relay, 0RTB - - - URD-000NH Digital (Sink), 0RTB (Sink) - - OT GSM/GPRS Modem RS I/O Expansion, Local & Remote Ethernet SCADA USB WEBSERVER Ethernet VNC URD-000CH Digital (Source), 0RTB (Source) - - URA-000W Analog Current bit, 0RTB - - URA-000W Analog Current bit, 0RTB - - CANbus RS5/ URA-000X Analog Voltage bit, 0RTB - - URA-000X Analog Voltage bit, 0RTB - - URA-000Y Analog Current 6bit, 0RTB - - URA-000Z Analog Voltage 6bit, 0RTB - - Local Expansion CANopen SAE J99 UniCAN FB PROTOCOL MODBUS RTU EtherNet/IP MODBUS TCP FB Protocol URD-000SN (Coming soon) Solid State Relay, VDC/VAC, A, 0RTB - - URD-000SM (Coming soon) Solid State Relay, 0VDC/VAC, A, 0RTB - - URD-000SK (Coming soon) Solid State Relay, 0VDC/VAC, 0.5A, 0RTB - - CANopen Slaves J99 Devices Remote High Speed I/O MODBUS RTU Slaves Ethernet IP (scanner & adaptor) MODBUS IP Slaves Power Module Article Number URP-PSV To be used when the required system current exceeds.5a Description Input VDC, Output system Power 5VDC/A Remote IO via Ethernet NEW! ProfiBus ProfiBus Slave Barcode Printer Barcode Reader BACnet, KNX, M-bus Via rd -party gateway Open Protocol 6 7

VisiLogic - Vision and Samba All-in-One programming software A single, intuitive environment for all your application needs Smart Utilities Remote Access, Efficient Data Management, and more Utility Name Function Key Features Targeted Users Remote Access View and control a PLC directly from PC, via local or remote connection View an HMI panel: use the PC keyboard + mouse to run the HMI application Operand and Data Table values: view values during runtime, import and export values to/ from Excel/.csv files Operators requiring Remote Access System integrators: remote debugging, troubleshooting, fault-finding Jazz Series Samba TM Series Vision TM Series UniStream Series Hardware Configuration Intuitive set up: controller, I/Os, and COM channels Ladder Programming Rapidly drag & drop elements and Function Blocks HMI Application Create beautiful HMI displays includes rich image library Remote Operator DataXport UniDownload Designer Download Manager & UniDownloader SD Card Suite Simultaneously view and operate the HMI panels of multiple PLCs in multiple locations Create Data Logs from Data Tables and operand values in PLCs Create compressed VisiLogic / U90Ladder applications(.udc files) for secure installation in local or remote PLCs Securely install.udc applications in local or remote PLCs Remotely access and manage SD cards and their data Easily place HMI panels side-by-side to monitor distributed systems or applications in several locations Run the HMI applications via PC keyboard + mouse Harvest data from multiple PLCs on demand or according to time/date Export the data to ± Excel/.csv files Automatically email files Prevent end-users from uploading and opening the application Include an OS to be installed at download Set a download channel, restrict end-user actions after installation and more Download Manager: installs the same application in multiple PLCs UniDownloader: installs an application in a single PLC Browse a remote PLC s SD card Read/write data, including Data Table files View SD card contents - Trends, logs, alarm history, data tables - export to Excel Control room operators Installation managers Data analysts Plant managers Process engineers OEMs / System Integrators can: Protect source code Enable customers to install an application without using VisiLogic or U90Ladder OEMs / System Integrators in installations with high security requirements Data analysts Plant managers Process engineers Alarms: Built-in Screens Effectively alert staff via Alarm screens UniVision Licensing Safeguard your PLC application security Embeds unique licenses in the PLC, which enables application to run only on a licensed PLC Option to activate or deactivate different sections of your application System integrators OEMs Prevents theft of applications Languages - String Library Instantly switch HMI language via screen touch Trend Graphs Display dynamic values in real time UniOPC Server Exchange data between Unitronics PLCs and OPC-supported software Create channel to connect PLCs to SCADA systems, such as plant control rooms Compliant with the OPC foundation standards Control room operators UniDDE Exchange data with Windows based applications Enables data exchange between Unitronics PLCs and software that supports Microsoft s Dynamic Data Exchange protocols, like Excel Control rooms operators Data Tables Create logs, import/export data, implement recipes Web Server Display and edit application values via browser Programming tools for developers Easily implement communication between PLC & PC applications Using ActiveX &.NET communication drivers Developers Software features vary according to controller model 9

Features: 0 /00 Advanced PLC with a built-in."/0." high-resolution color touch screen. Snap in I/Os to expand up to 000 I/Os. Snap-in I/O Plugs directly into the back of your PLC HMI Size:." and 0." High quality color touchscreen Multi-language display Built-in Alarm Screens Vision TM Series UniStream Series PLC I/O options include digital, analog, high speed, temperature, and weight measurement Expand up to 000 I/Os Auto-tune PID, up to independent loops Recipe programs and data logging via data tables MicroSD card - log, backup, clone & more Function Blocks Vision 00 Vision 0 Article Number V00-T0B V0-T0BJ I/O Options Total supported I/Os 000 I/O Expansion Snap-in I/O Modules plug directly into the back of the Vision unit (See Snap-in I/O Modules- page 7). Local or Remote I/Os may be added via expansion port or via CANbus (See I/O Expansion Modules- page 6). Jazz Series Samba TM Series Communication Built-in ports: Mini USB for programming CANbus Isolated RS5/RS Add-on ports: Serial/Ethernet V0 Local I/O Expansion Use Local Expansion Adapters to add up to modules Remote I/O Expansion Use EX-RC adapters to further extend the number of I/Os Program Application Memory Scan Time Memory Operands HMI Panel Color Touchscreen Application Logic: MB Images: MB Fonts: MB 9μsec per K of typical application 9 coils, 096 registers, 5 long integers ( bit), 56 double words ( bit unsigned), 6 floats, timers (_bit), _counters Additional non-retainable operands: 0 X-bits, 5 X-integers, 56 X-long integers, 6 X-double words Resistive, Analog Protocols: MODBUS TCP SNMP V CANopen, CANlayer, UniCAN BACnet, KNX and M-Bus via gateway FB Protocol: for any rd party protocol General Features: Web server E-mail & SMS Remote access utilities G Modem support V00 Cut Out Height x Width (mm) Resolution 0 x 7.5 x 97 00 x 600 (SVGA) Keys 9 programmable function keys Virtual Keyboard Environment Protection IP65 / NEMAX (when panel mounted) IP66, IP65 and NEMAX (when panel mounted) Operating Temperature 0 to 50ºC Standards UL, CE, EAC, UL Hazardous Locations, Class I, Division General Battery Clock 7 years typical at 5 C, battery back-up for all memory sections and RTC Real-time clock functions (date and time) Power Supply /VDC I ve not yet encountered a job that a Unitronics PLC was unable to cover. Timothy Moulder, Engineer at Black & Decker EX-RC: via CANbus, integrate standard Unitronics I/O modules at distances of up to 000m. For a list of relevant models, contact Unitronics. V applies to PLC power supply only, and not to the I/O. 0

Features: HMI 700 Size: 7" High quality color touchscreen Multi-language display Built-in Alarm Screens Advanced PLC with a built-in 7" high-resolution color touch screen. Snap in I/Os to expand up to 000 I/Os. Reliability, ease of use, connectivity and competitive prices are Unitronics main strengths. Mr. Andrea Della Bosca, EV srl I/O Options Jazz Series Samba TM Series Vision TM Series UniStream Series PLC I/O options include digital, analog, high speed, temperature, and weight measurement Expand up to 000 I/Os Auto-tune PID, up to independent loops Recipe programs and data logging via data tables MicroSD card - log, backup, clone & more Function Blocks Communication Built-in ports: Ethernet TCP/IP Mini USB for programming RS5/RS Add-on ports: Serial/Profibus CANbus Protocols: MODBUS TCP SNMP V CANopen, CANlayer, UniCAN BACnet, KNX and M-Bus via gateway FB Protocol: for any rd party protocol V700 Total supported I/Os 000 I/O Expansion Snap-in I/O Modules plug directly into the back of the Vision unit (See Snap-in I/O Modules- page 7). Local or Remote I/Os may be added via expansion port or via CANbus (See I/O Expansion Modules- page 6). Local I/O Expansion Use Local Expansion Adapters to add up to modules Remote I/O Expansion Use EX-RC adapters to further extend the number of I/Os Program Application Memory Application Logic: MB Images: 0MB Fonts: MB Scan Time 9μsec per K of typical application Memory Operands 9 coils, 096 registers, 5 long integers (-bit), 56 double words (-bit unsigned), 6 floats, timers (-bit), counters. Additional non-retainable operands: 0 X-bits, 5 X-integers, 56 X-long integers, 6 X-double words HMI Panel Color Touchscreen Resistive, Analog Cut Out Height x Width (mm) 5 x 9 Resolution Keys Environment Protection 00 x 00 (SVGA) Virtual Keyboard IP66, IP65 and NEMAX Operating Temperature 0 to 50ºC Standards UL, CE, EAC, UL Hazardous Locations, Class I, Division General Battery Clock 7 years typical at 5 C, battery back-up for all memory sections and RTC Real-time clock functions (date and time) Power Supply /VDC EX-RC: via CANbus, integrate standard Unitronics I/O modules at distances of up to 000m. General Features: Web server E-mail & SMS G Modem support Remote access utilities For a list of relevant models, contact Unitronics. V applies to PLC power supply only, and not to the I/O.

Vision TM Series UniStream Series Features: HMI Size: 5.7" High quality color touchscreen Multi-language display Built-in Alarm Screens PLC 570 /560 I/O options include digital, analog, high speed, temperature, and weight measurement Expand up to 000 I/Os Auto-tune PID, up to independent loops Recipe programs and data logging via data tables MicroSD/ SD card log, backup, clone & more Function Blocks Advanced PLC with a built-in 5.7" high-resolution color touch screen. Snap in I/Os to expand up to 000 I/Os. For a first time user, I had a great experience. I look forward to incorporating this brand of product on future jobs. Jeremy Charles Keene, Controls Manager at General Broach Company Vision 570 Vision 560 Article Number V570-57-T0B-J V560-T5B I/O Options Total supported I/Os 000 I/O Expansion Local I/O Expansion Snap-in I/O Modules plug directly into the back of the Vision unit (See Snap-in I/O Modules- page 7). Local or Remote I/Os may be added via expansion port or via CANbus (See I/O Expansion Modules- page 6). Use Local Expansion Adapters to add up to modules Remote I/O Expansion Use EX-RC adapters to further extend the number of I/Os Jazz Series Samba TM Series Communication Built-in ports: Mini USB for programming in V570 CANbus Isolated RS5/ RS Add-on ports: Serial/Ethernet V570 Program Application Memory Scan Time Memory Operands HMI Panel Color Touchscreen Cut Out Height x Width (mm) Resolution Application Logic: MB Images: 6MB Fonts: MB 9μsec per K of typical application 9 coils, 096 registers, 5 long integers (-bit), 56 double words (-bit unsigned), 6 floats, timers (-bit), counters. Additional non-retainable operands: 0 X-bits, 5 X-integers, 56 X-long integers, 6 X-double words Resistive, Analog.5 x 6.0 x 09 0 x 0 (QVGA) Protocols: MODBUS TCP SNMP V CANopen, CANlayer, UniCAN BACnet, KNX and M-Bus via gateway FB Protocol: for any rd party protocol Keys Environment Protection Virtual Keyboard NEMAX, IP66, IP65 (when panel mounted) Operating Temperature 0 to 50ºC programmable keys Labeling options function keys or customized NEMAX, IP65 (when panel mounted) Standards UL, CE, EAC, UL Hazardous Locations, Class I, Division UL, CE, EAC General Features: Web server E-mail & SMS G Modem support Remote access utilities V560 General Battery Clock 7 years typical at 5 C, battery back-up for all memory sections and RTC Real-time clock functions (date and time) Power Supply /VDC EX-RC: via CANbus, integrate standard Unitronics I/O modules at distances of up to 000m. For a list of relevant models, contact Unitronics. V applies to PLC power supply only, and not to the I/O. 5

UniStream Series Vision TM Series Samba TM Series Jazz Series Features: HMI General Features: Web server E-mail & SMS G Modem support Remote access utilities 0 Size:." High quality color touchscreen Multi-language display Built-in Alarm Screens PLC I/O options include digital, analog, high speed, temperature, and weight measurement Expand up to 5 I/Os Auto-tune PID, up to independent loops Recipe programs and data logging via data tables Micro SD card - log, backup, clone & more Function Blocks Communication Built-in ports: Mini USB for programming RS5/RS Add-on ports: Serial/Ethernet/Profibus CANbus Protocols: MODBUS TCP SNMP V CANopen, CANlayer, UniCAN BACnet, KNX and M-Bus via gateway FB Protocol: for any rd party protocol Advanced PLC with a built-in." wide-aspect color touch screen. Includes built-in I/O configuration, expand up to 5 I/Os. V0 The huge advantage of this PLC was that - with everything built-in the communications and use of tags in the HMI was so simple and intuitive. Ashley Parr, I/O Options Total supported I/Os 5 Built-in According to model (See Built-in I/Os table below) I/O Expansion Add Local I/O via expansion port Add Remote I/Os via CANbus (See I/O Expansion Modules- page 6) Local I/O Expansion Use Local Expansion Adapters to add up to modules Remote I/O Expansion Use EX-RC adapters to further extend the number of I/Os Program Application Memory Application Logic: MB Images: MB Fonts: 0KB Scan Time 5μ sec per K of typical application Memory Operands 9 coils, 096 registers, 5 long integers (-bit), 56 double words (-bit unsigned), 6 floats, timers (-bit), counters Additional non-retainable operands: 0 X-bits, 5 X-integers, 56 X-long integers, 6 X-double words HMI Panel Color Touchscreen Resistive, Analog Cut Out Height x Width (mm) 9.5 x.5 Resolution 0 x 7 Keys 5 programmable Environment Protection NEMAX, IP66, IP65 (when panel mounted) Operating Temperature 0 to 50ºC Standards UL, CE, EAC, UL Hazardous Locations, Class I, Division General Battery Clock Vision0 models - Built-in I/O configurations In some models certain inputs are adaptable via wiring and software settings, and can function as digital,high-speed, analog, and in certain models 7 years typical at 5 C, battery back-up for all memory sections and RTC Real-time clock functions (date and time) EX-RC: via CANbus, integrate standard Unitronics I/O modules at distances of up to 000m. For a list of relevant models, contact Unitronics. HPS The total number of digital outputs listed 6 as TC or PT00. Each TC requires pins per TC input PT inputs uses 5 input pins. 7 Article Summary Adapting requires input pins. This reduces the number of digital inputs. Pin requirements: Digital HSC/Shaft-encoder Each high-speed requires or pins according to high-speed mode. Each analog input requires pin. The first PT input requires pins and two additional pins for each additional PT input. Inputs Analog Temperature Measurement Example: V0-J-RA offers digital inputs. Implementing TC inputs requires pins, leaving pins free. Implementing The total number of digital inputs listed includes high-speed and adaptable inputs. includes high-speed outputs. Transistor PWM/HSO Relay Analog V0-J-B No onboard I/Os /VDC V0-J-RH V0-J-R V0-J-TR V0-J-RH6 V0-J-RA V0-J-TRA V0-J-T V0-J-T V0-J-TA 0 Digital, D/A Inputs 6 Relay 0 Digital, D/A Inputs Relay 0 Digital, D/A Inputs Relay, High-speed Transistor 6 Digital, D/A Analog Inputs 6 Relay Digital, D/A, TC/PT00/ Digital Inputs Relay, Analog Digital, D/A, TC/PT00/ Digital Inputs Relay, Analog, High- Speed Transistor 0 Digital, D/A Inputs Transistor 0 Digital, D/A Inputs 6 Transistor Digital, D/A, TC/PT00/ Digital Inputs 0 Transistor, Analog 00kHz, -bit 0kHz, -bit 00kHz, -bit 00kHz, -bit 0kHz, -bit 00kHz, -bit 0kHz, -bit 0kHz, -bit 0kHz, -bit 0-0V, 0-0mA, -0mA 0-bit 0-0V, 0-0mA, -0mA 0-bit 0-0V, 0-0mA, -0mA 0-bit 0-0V, 0-0mA, -0mA and 0-0mA, -0mA 0-bit 0-0V, 0-0mA, -0mA -bit 0-0V, 0-0mA, -0mA -bit 0-0V, 0-0mA, -0mA 0-bit 0-0V, 0-0mA, -0mA 0-bit 0-0V, 0-0mA, -0mA -bit Operating Voltage 6 VDC VDC ( PTO) 00 khz max VDC 6 VDC Thermocouple, PT00 Thermocouple, PT00 Thermocouple, PT00 6 0 ( PTO) 00 khz max 7 0.5kHz 7 0.5kHz 5 0.5kHz 0-0V, -0mA -bit 0-0V, -0mA -bit VDC VDC VDC VDC 0-0V, -0mA -bit VDC

I/O Options Jazz Series Samba TM Series Vision TM Series UniStream Series Features: HMI 50 Size:.5" High quality color touchscreen Multi-language display Built-in Alarm Screens PLC I/O options include digital, analog, high speed, temperature, and weight measurement Expand up to 5 I/Os Auto-tune PID, up to independent loops Recipe programs and data logging via data tables Micro SD card - log, backup, clone & more Function Blocks Communication Built-in ports: Mini USB for programming RS5/RS Add-on ports: Serial/Ethernet/Profibus CANbus Palm-sized All-in-One: advanced PLC with a.5" color touchscreen. Includes built-in I/O configuration, expands up to 5 I/Os. V50 Total supported I/Os 5 Built-in According to model (See Built-in I/Os table below) I/O Expansion Add Local I/O via expansion port Add Remote I/Os via CANbus. (See I/O Expansion Modules- page 6) Local I/O Expansion Use Local Expansion Adapters to add up to modules Remote I/O Expansion Use EX-RC adapters to further extend the number of I/Os Program Application Memory Application Logic: MB Images: MB Fonts: 0KB Scan Time 5μ sec per K of typical application Memory Operands 9 coils, 096 registers, 5 long integers (-bit), 56 double words (-bit unsigned), 6 floats, timers (-bit), counters Additional non-retainable operands: 0 X-bits, 5 X-integers, 56 X-long integers, 6 X-double words HMI Panel Color Touchscreen Resistive, Analog Cut Out Height x Width (mm) 9 x 9 Resolution 0 x 0 (QVGA) Keys 5 programmable keys. Labeling options - function keys, arrows, or customized Environment Protection NEMAX, IP66, IP65 (when panel mounted) Operating Temperature 0 C to 50 C, For V50-JS-TA: -0 C to 60 C Standards UL, CE, EAC, UL Hazardous Locations, Class I, Division General Battery Clock Vision50 models - Built-in I/O configurations Article 5 Summary Digital HSC/Shaftencoder 7 years typical at 5 C, battery back-up for all memory sections and RTC Real-time clock functions (date and time) Inputs Analog EX-RC: via CANbus, integrate standard Unitronics I/O modules at distances of up to 000m. Extended temperature cards: CANBus p/n: V00-S-CAN, Ethernet p/n V00-S-ET. For a list of relevant models, contact Unitronics. Temperature Measurement Transistor PWM/HSO Relay Analog V50-J-B No onboard I/Os /VDC V50-J-TR0 0 Digital, D/A Inputs 6 Relay High-speed Transistor 00kHz, -bit 0-0V, 0-0mA, -0mA 0-bit ( PTO) 00 khz max Operating Voltage 6 VDC Protocols: MODBUS TCP SNMP V CANopen, UniCAN, CANlayer BACnet, KNX and M-Bus via gateway FB Protocol: for any rd party protocol General Features: Web server E-mail & SMS G Modem support Remote access utilities V50-J-R V50-J-TR V50-J-TR6 V50-J-RA V50-J-TRA 0 Digital, D/A Inputs Relay 0 Digital, D/A Inputs Relay, High-speed Transistor 6 Digital, D/A Analog Inputs 6 Relay High-speed Transistor Digital, D/A, TC/PT00/ Digital Inputs Relay, Analog Digital, D/A, TC/PT00/ Digital Inputs Relay, Analog, High- Speed Transistor 0kHz, -bit 00kHz, -bit 00kHz, -bit 0kHz, -bit 00kHz, -bit 0-0V, 0-0mA, -0mA 0-bit 0-0V, 0-0mA, -0mA 0-bit 0-0V, 0-0mA, -0mA and 0-0mA, -0mA 0-bit 0-0V, 0-0mA, -0mA -bit 0-0V, 0-0mA, -0mA -bit VDC Thermocouple, PT00 Thermocouple, PT00 ( PTO) 00 khz max ( PTO) 00 khz max ( PTO) 00 khz max VDC 6 VDC 0-0V, -0mA -bit 0-0V, -0mA -bit VDC VDC V50-J-T 0 Digital, D/A Inputs Transistor 0kHz, -bit 0-0V, 0-0mA, -0mA 0-bit 7 0.5kHz VDC 60ºC -0ºC Extended temperature unit available: Operational temperature range between -0ºC to 60ºC, available for panel Article: V50-JS-TA. Extended temperature available for Ethernet (Article: V00-S-ET) and CANbus (Article: V00-S-CAN). V50-J-T V50-J-TA V50-JS-TA 0 Digital, D/A Inputs 6 Transistor Digital, D/A, TC/PT00/ Digital Inputs 0 Transistor, Analog 0kHz, -bit 0kHz, -bit 0-0V, 0-0mA, -0mA 0-bit 0-0V, 0-0mA, -0mA -bit Thermocouple, PT00 6 0 7 0.5kHz 5 0.5kHz VDC 0-0V, -0mA -bit VDC In some models certain inputs are adaptable via wiring and software settings, and can function as digital, high-speed, analog, and in certain models as TC or PT00. Adapting requires input pins. This reduces the number of digital inputs. Pin requirements: Each high-speed requires or pins according to high-speed mode. Each analog input requires pin. Each TC requires pins per TC input The first PT input requires pins, and two additional pins for each additional PT input. Example: V50-5-RA offers digital inputs. Implementing TC inputs requires pins, leaving pins free. Implementing PT inputs uses 5 input pins. The total number of digital inputs listed includes high-speed and adaptable inputs. The total number of digital outputs listed includes high-speed outputs. Extended temperature unit 5 To order a classic V50 with a Bezel panel, switch the 'J' in the model number to '', ex. V50, V50-- TR0 9

Vision TM Series UniStream Series Features: HMI Size:." Monochrome Multi-language display Built-in Alarm Screens PLC 0 I/O options include digital, analog, high speed, temperature, and weight measurement Expand up to 56 I/Os Auto-tune PID, up to independent loops Recipe programs and data logging via data tables Micro SD card - log, backup, clone & more Function Blocks Palm-size, powerful PLC with built-in black & white LCD.", keypad and I/Os, expands up to 56 I/Os. I/O Options Total supported I/Os 56 Built-in According to model (See Built-in I/Os table below) I/O Expansion Add Local I/O via expansion port Add Remote I/Os via CANbus. (See I/O Expansion Modules- page 6) Local I/O Expansion Use Local Expansion Adapters to add up to modules Remote I/O Expansion Use EX-RC adapters to further extend the number of I/Os Program Application Memory Application Logic: KB Images: KB Fonts: KB Scan Time 0μ sec per K of typical application Memory Operands 096 coils, 0 registers, 56 long integers (-bit), 6 double words (-bit unsigned), floats, 9 timers (-bit), counters Additional non-retainable operands: 0 X-bits, 5 X-integers, 56 X-long integers, 6 X-double words HMI Panel Touch screen - Cut Out Height x Width (mm) 9 x 9 Resolution x 6 Keys 0, including 0 user labeled keys (slide kit sold separately) Environment Protection NEMAX, IP66, IP65 (when panel mounted) Operating Temperature 0 to 50ºC Standards UL, CE, EAC, UL Hazardous Locations, Class I, Division General Jazz Series Samba TM Series Communication Built-in ports: RS5/RS Add-on ports: Serial/Ethernet/Profibus CANbus Protocols: MODBUS TCP SNMP V CANopen, UniCAN, CANlayer BACnet, KNX and M-Bus via gateway FB Protocol: for any rd party protocol General Features: Web server E-mail & SMS G Modem support Remote access utilities V0 Battery Clock Vision0 models - Built-in I/O configurations Article Summary Digital HSC/Shaftencoder 7 years typical at 5 C, battery back-up for all memory sections and RTC Real-time clock functions (date and time) Inputs Analog EX-RC: via CANbus, integrate standard Unitronics I/O modules at distances of up to 000m. For a list of relevant models, contact Unitronics. Temperature Measurement Transistor PWM/HSO Relay Analog V0-J-B No onboard I/Os /VDC V0-J-TR0 V0-J-R V0-J-TR V0-J-TR6 V0-J-RA V0-J-TRA 0 Digital, D/A Inputs 6 Relay High-speed Transistor 0 Digital, D/A Inputs Relay 0 Digital, D/A Inputs Relay, High-speed Transistor 6 Digital, D/A Analog Inputs 6 Relay High-speed Transistor Digital, D/A, TC/PT00/ Digital Inputs Relay, Analog Digital, D/A, PT00/ TC/ Digital Inputs Relay, Analog, High-Speed Transistor 0-0V, 0-0mA, -0mA 00kHz, -bit 0-bit 0kHz, -bit 0-0V, 0-0mA, -0mA 0-bit 0-0V, 0-0mA, -0mA 00kHz, -bit 0-bit 00kHz, -bit 0kHz, -bit 00kHz, -bit 0-0V, 0-0mA, -0mA and 0-0mA, -0mA 0-bit 0-0V, 0-0mA, -0mA -bit 0-0V, 0-0mA, -0mA -bit ( PTO) 00 khz max Operating Voltage 6 VDC VDC Thermocouple, PT00 Thermocouple, PT00 ( PTO) 00 khz max ( PTO) 00 khz max ( PTO) 00 khz max VDC 6 VDC 0-0V, -0mA -bit 0-0V, -0mA -bit VDC VDC V0-J-T 0 Digital, D/A Inputs Transistor 0kHz, -bit 0-0V, 0-0mA, -0mA 0-bit 7 0.5kHz VDC 0 The perfect solution for our need, the Vision0 is easy to program, user-friendly and backed up with responsive tech support. Michael Lamore, President of Barrier V0-J-T V0-J-TA 0 Digital, D/A Inputs 6 Transistor Digital, D/A, TC/PT00/ Digital Inputs 0 Transistor, Analog In some models certain inputs are adaptable via wiring and software settings, and can function as digital, highspeed, analog, and in certain models as TC or PT00. Adapting requires input pins. This reduces the number of digital inputs. Pin requirements: 0kHz, -bit 0kHz, -bit 0-0V, 0-0mA, -0mA 0-bit 0-0V, 0-0mA, -0mA -bit Each high-speed requires or pins according to high-speed mode. Each analog input requires pin. Each TC requires pins per TC input The first PT input requires pins, and two additional pins for each additional PT input. Thermocouple, PT00 Example: V0--RA offers digital inputs. Implementing TC inputs requires pins, leaving pins free. Implementing PT inputs uses 5 input pins. 6 0 7 0.5kHz 5 0.5kHz VDC The total number of digital inputs listed includes high-speed and adaptable inputs. The total number of digital outputs listed includes high-speed outputs. To order a classic V0 with a Bezel panel, switch the 'J' in the model number to '5' ex. V0, V0--TR0. 0-0V, -0mA -bit VDC

Features: HMI Size:.5",.", 7" High quality color touchscreen Multi-language display Built-in Alarm Screens Full-function PLC with built-in, highresolution full-color touch screen and built-in I/O configuration. Great look, incredible price. SAMBA Article Number SAMBA.5 SAMBA. SAMBA 7 I/O Options Total supported I/Os Built-in According to model (See Built-in I/Os table below) I/O Expansion - Remote I/O Expansion Use EX-RC adapters to further extend the number of I/Os COM Modules Fit up to CANbus, RS/RS5 or Ethernet Jazz Series Samba TM Series Vision TM Series UniStream Series PLC I/O options include digital, analog, and high speed Auto-tune PID, up to independent loops Recipe programs and data logging via data tables Function Blocks Communication Built-in ports: Mini USB for programming for." & 7"models, RS for.5" model Add-on ports: Serial/Ethernet CANbus Protocols: SAMBA.5" Program Application Memory Scan Time Memory Operands HMI Panel Color Touchscreen Cut Out Height x Width (mm) Application Logic: 0KB Images:.5 MB Fonts: 0 KB Application Logic: 9KB Images: MB Fonts: 0 KB 5μS per K of typical application Application Logic: 9KB Images: MB Fonts: 5 KB 5 coils, 56 registers, long integers (-bit), double words (-bit unsigned), floats, timers (-bit), 6 counters. Additional non-retainable operands: 6 X-bits, X-integers, 6 X-long integers, 6 X-double words (-bits unsigned) Resistive, Analog 9 X 9.5 X 9.5 9 X 5 Resolution 0 X 0 (QVGA) 0 X 7 00 x 0 (WVGA) Keys Environment Protection Displays virtual keyboard when the application requires data entry NEMAX/IP66/IP65 (when panel mounted) Operating Temperature 0 to 50ºC Standards UL, CE, EAC, UL Hazardous Locations, Class I, Division General MODBUS TCP SNMP V CANopen, UniCAN, CANlayer BACnet, KNX and M-Bus via gateway FB Protocol: for any rd party protocol General Features: E-mail & SMS G Modem support Remote access utilities SAMBA." Battery Clock Samba models - Built-in I/O configurations Article Summary Digital SM5-J-R0 SM-J-R0 SM70-J-R0 0 Digital, D/A Inputs, Relay HSC/Shaftencoder 0kHz, -bit 7 years typical at 5 C, battery back-up for RTC and system data, including variable data Real-time clock functions (date and time) EX-RC: via CANbus, integrate standard Unitronics I/O modules at distances of up to 000m. Refer to website for more information. For a list of relevant models, contact Unitronics. Inputs Analog 0-0V, 0-0mA, -0mA 0-bit Temperature Measurement Transistor PWM/HSO Relay Analog Operating Voltage VDC SM5-J-T0 SM-J-T0 SM70-J-T0 0 Digital, D/A Inputs, Transistor 0kHz, -bit 0-0V, 0-0mA, -0mA 0-bit 7 0.5kHz VDC SM5-J-RA SM-J-RA SM70-J-RA Digital, HSC/Shaftencoder, AI, PT00/TC, Relay, AO 0kHz, -bit 0-0V, 0-0mA, -0mA /-bit PT00/TC 0-0V, -0mA, -bit VDC SM5-J-TA SM-J-TA SM70-J-TA Digital, HSC/Shaftencoder, AI, PT00/TC, Transistor, AO 0kHz, -bit 0-0V, 0-0mA, -0mA /-bit PT00/TC 5 0.5kHz 0-0V, -0mA, -bit VDC SAMBA 7" In some models certain inputs are adaptable via wiring and software settings, and can function as digital or analog. Adapting requires input pins. This reduces the number of digital inputs. Pin requirements: Each analog input requires pin. Example: SM5-J-R0 offers digital inputs. Implementing analog inputs requires pins, leaving 0 pins free. The total number of digital inputs listed includes highspeed and adaptable inputs. The total number of digital outputs listed includes high-speed outputs. When selecting NPN for the digital inputs, the Analog inputs cannot be used.

Jazz Series Samba TM Series Vision TM Series UniStream Series Features: HMI Up to 60 user-designed screens Multi language PLC I/O options include digital, analog, temperature and high speed Auto-tune PID, up to independent loops (according to model*) Communication Built-in ports: Mini USB for programming Add-on ports: Ethernet TCP/IP RS / RS5 Protocols: PC access via MODBUS or OPC server Supports MODBUS protocol (according to model) General Features: SMS via GSM G Modem support Remote access utilities Accessories: Program Cloner module- Copy applications from PLC to PLC Keypad Slide kit- Customize the Jazz keypad to your application *Up to loops: models UA / UN0 loop: all other models DIN-rail Power Supplies UAP-VW UAP-V60W UAP-V96W W V A 60W V.5A 96W V A GSM Not yet UL certified GSM-KIT-7J-G KIT, MODEM GPRS, CINTERION, EHS6T Jazz Add-on ports and Accessories An All-in-One unit as affordable as a "smart relay". Full-function PLC combined with a textual HMI and keypad, with up to 0 built-in I/Os. Jazz COM Port kit Ethernet Communication Port Program Cloner module Keypad Slide kit RS/RS5 (isolated) Article No.: JZ-RS Article No.: MJ0-ET Article No.: MJ0-MEM Article No.: MJ0-JZ-SL I/O Options Total supported I/Os 0 Built-in According to model (See Built-in I/Os table below) I/O Expansion - Program Memory Operands 56 coils, 56 registers, 6 timers Ladder Memory K HMI Panel Touch screen - Cut Out Height x Width (mm) 7 x 9 Resolution lines, 6 characters Keys 6 keys, including 0 user-labeled keys Environment Protection NEMAX/IP65 (when panel mounted) Operating Temperature 0 to 50ºC Standards General Battery Clock Jazz models - Built-in I/O configurations UL, CE, EAC 0 years typical at 5 C, battery back-up for RTC and system data, including variable data Inputs Article Summary Digital HSC/Shaft-encoder Analog JZ0-J-R0 JZ0-J-R6 JZ0-J-R6HS JZ0-J-R JZ0-J-T0 JZ0-J-T JZ0-J-T0HS JZ0-J-T0 JZ0-J-UA JZ0-J-UN0 6 Digital Inputs Relay 6 Digital, D/A, Analog Inputs 6 Relay 6 Digital, HSC/Shaft-encoder, A/D, AI, 6 Relay outputs 6 Digital, D/A, Analog Inputs Relay 6 Digital Inputs Transistor 6 Digital, D/A, Analog Inputs Transistor 6 Digital, HSC/Shaft-encoder, A/D, AI, 0 Transistor outputs 6 Digital, D/A, Analog Inputs 0 Transistor 9 Digital Inputs, HSC, A/D, AI, TC/PT00, 5 Relay, Transistor, AO 9 Digital, D/A, Analog TC/PT00 Inputs 5 Relay Transistor In some models certain inputs are adaptable, and can function as either digital or analog. Adapting requires input pins. This reduces the number of digital inputs. Pin requirements: Each analog input requires pin. 6 0kHz, 6-bit 0kHz, 6-bit Real-time clock functions (date and time) Temperature Measurement Transistor PWM/HSO Relay Analog Operating Voltage VDC 0-0V 0 or -bit 0-0mA, -0mA 0 or -bit 0-0V 0 or -bit 0-0mA, -0mA 0-bit 6 VDC 6 VDC 0-0V 0 or -bit 0-0mA, -0mA 0-bit VDC 6 0kHz, 6-bit VDC 0-0V 0-bit 0-0mA, -0mA VDC 0-bit 0kHz, 6-bit 0kHz, 6-bit 5kHz, 6-bit 0-0V 0-bit 0-0V 0-bit 0-0mA, -0mA 0-bit 0-0mA -0mA 0-0 VDC 0-0V 0-bit 0-0mA, -0mA 0-bit Thermocouple, PT00 Thermocouple, PT00 0 khz VDC VDC 5 +/-0V, -0mA -bit VDC 5 VDC Note that the high-speed inputs Note that the high-speed outputs To order a classic Jazz with a are included in the total number are included in the total number Bezel panel, omit the 'J' from the of digital inputs of / digital outputs model number, ex. JZ0-R0 5

UniStream Series Vision TM Series Samba TM Series Jazz Series I/O Expansion Modules & Accessories- Vision Series Expand your system with local or remote I/O expansion modules. Digital XL Digital/ Analog High-speed Remote I/O Module Inputs Operating Expansion Temperature Weight Digital Voltage Modules Article HSC 5 Analog Transistor Measurement Measurement PWM/HSO 6 Relay Analog IO-DI-TO VDC / 5kHz 6-bit IO-DI-RO VDC / 5kHz 6-bit IO-DI-RO VDC / 5kHz 6-bit EX90-DI-RO VDC 5kHz 6-bit IO-DI6 VDC 9 6 IO-TO6 VDC 6 / 5kHz 6-bit IO-RO VDC 9 IO-RO6 6 VDC 9 IO-DIACH AC 0/0 VAC IO-AI-AO 0-0V, 0-0mA, -0mA -bit IO-PT00 IO-PTK I/O Expansion Module Adapters I/O Expansion Module Adapters PT00/NI00/NI0 PT000/NI000 IO-AO6X IO-LC IO-LC IO-ATC IO-AI IO-D6A-RO6 IO-D6A-TO6 6 / 6 / EX-D6A-RO 7 6 / EX-D6A-TO6 7 6 / EXF-RC5,,0 9 / Article EX-AX EX-RC, 0kHz 6/-bit 0kHz 6/-bit 0kHz 6/-bit 0kHz 6/-bit 00kHz -bit ±0V -bit+sign, 0-0mA, -0mA -bit VDC Not relevant Not relevant Loadcell / Strain gauge Loadcell / Strain gauge 6 (Isolated) 0-0V, 0-0mA, -0mA -bit VDC VDC VDC Thermocouple, 0-0V, 0-0mA, -0mA -bit Not relevant 0-0V, 0-0mA, -0mA Not relevant -bit 0-0mA, -0mA 6 VDC 0-bit 0-0mA, -0mA 0-bit 0-0mA, -0mA 0-bit 0-0mA, -0mA 0-bit Description 5, / 0.5kHz 50kHz None VDC None None VDC Local I/O module adapter, Galvanic isolation. Up to modules may be connected to a single PLC Supports both / VDC Remote I/O module adapter, via CANbus. Multiple adapters may be connected to a single PLC, with up to modules to each adapter. Supports both / VDC. 5 6 7 9 0 5 / 0.5kHz 50kHz (up to PTO) None VDC VDC Number of supported I/Os & I/O modules varies according to module. The EXF-RC5 functions as a node in a Vision UniCAN network and connects to the Vision controller via CANbus and programmed in VisiLogic. The EXF-RC5 cannot be extended as regular I/O unit. High-speed inputs are configurable as either high-speed counter (HSC) or shaft-encoder. The EX90 is housed in an open casing. Only one EX90 can be connected per PLC, as a single expansion module; Expansion adapter not required. Supported by Samba, Vision and UniStream series. The total number of digital inputs listed includes high-speed inputs. Example: the IO-D6A-TO6 offers a total of 6 / inputs. You can configure I as a HSC and I5 as a Counter reset; this reduces the available number of digital inputs to. The total number of digital outputs listed includes high-speed outputs. Example: the IO-D6A-TO6 offers a total of 6 transistor outputs. You can configure to High-speed output, reducing the number of available digital outputs to 5. Functions as local adapter. Can support up to 7 I/O modules. 6-bit or -bit, depending on the PLC. Also available as VDC contact us for part number. One HSC may be configured as a shaft encoder. Snap-in I/O Modules Compatible with Vision models: V560, V570, V700, V00 and V0. Snap-in I/O Article V00--EB V00--EB V00--EXB V00--EXB V00--E5B V00--E6B V00--E6B The total number of digital inputs listed includes high-speed inputs. The total number of digital outputs listed includes high-speed outputs. Not yet UL certified Vision & Samba COM Modules Enhance Vision s communication capabilities Model Ethernet RS/RS5 Isolated RS/RS5 CANbus Profibus SAMBA V00-7-ET V00-7-RS V00-7-RSX V00-7-CAN V0, V50, V0 Digital (isolated) 6 / 6 / / / / / / V00--E6B 0 / Analog, Temperature and Weight/Strain Measurements HSC/Shaftencoder 0kHz -bit 0kHz -bit 0kHz -bit 0kHz -bit 0kHz -bit 0kHz -bit 0kHz -bit 0kHz -bit V00-7-ET, V00-S-ET 5 V00-7-RS V00-7-RSX Inputs Temperature Analog Measurement 0-0 V, 0-0mA, -0mA 0-bit 0-0 V, 0-0mA, -0mA 0-bit (Isolated) Thermocouple, PT00, 0-0V, 0-0mA, -0mA -bit (Isolated) Thermocouple, PT00, 0-0V, 0-0mA, -0mA -bit 0-0 V,0-0mA, -0mA 0-bit V00-7-CAN, V00-S-CAN 5 V00-7-PB V560, V570, V00, V0 V00-9-ET V00-9-RS V00-9-RS-X Built-in V700 Built-in V00-7-RS V00-7-RSX V00-7-CAN V00-7-PB Thermocouple, PT00, 0-0V, 0-0mA, -0mA -bit 0-0V, 0-0mA, -0mA 0-bit 6 0-0 V,0-0mA,-0mA -bit 0-0 V,0-0mA,-0mA 0-bit 0-0 V,0-0mA,-0mA 0-bit V0/V50/V0: Two ports may be added: for Serial/Ethernet/Profibus and for CANbus. V560/V570/V00/V0: port may be added: Serial/Ethernet. Extended temperature cards, operational temperature : -0ºC to 60ºC (-ºF to 0ºF) - for V50-JS-TA only. V700 is supplied with an Built-in Ethernet port. One port may be added: serial/profibus, and CANbus. 5 Not yet UL certified Transistor PWM/HSO (isolated) Relay Analog / / / 5 / 5 / / / / 0.5kHz 50kHz 0.5kHz 50kHz 0.5kHz 50kHz 0.5kHz 50kHz 0.5kHz 50kHz 0.5kHz 50kHz 0.5kHz 00kHz 0.5kHz 00kHz Operating Voltage 0 VDC 0 5 0-0 V,0-0mA,-0mA -bit (Isolated) 0-0 V, -0mA -bit (Isolated) 0-0 V, -0mA -bit VDC VDC VDC VDC 5 5 (Isolated) 0-0 V, -0mA -bit (Isolated) 0-0 V, -0mA -bit VDC VDC VDC DIN-rail Power Supplies UAP-VW UAP-V60W UAP-V96W W V A 60W V.5A 96W V A 6 7 GSM GSM-KIT-7J-G KIT, MODEM GPRS, CINTERION, EHS6T

NEW! Moving your Control Forward Specifications Variable Frequency Drives UMI-B EU UMI-B UL UMI-B5 UL Use our s as a stand-alone product or integrated with our PLC+HMI controllers. Input Voltage Input Frequency 00-0VAC, Single Phase 0-0VAC, Three Phase 00-0VAC, Single Phase 00-0VAC, Three Phase 0-0VAC, Three Phase 50/60Hz 00-0VAC, Three Phase 0-0VAC, Three Phase UniStream Series Power Supported Motors Asynchronous Induction Motors, Three Phase Input Output Frequency 0-00Hz Asynchronous Induction Motors, Three Phase Input Permanent Magnet Synchronous Motors, Three Phase Input 50%, 60 seconds Vision TM Series Overload Capacity Control Method 0%, 0 seconds 00%, second SVPWM (Space Vector PWM) SVC (Sensorless Vector Control) Samba TM Series Jazz Series Control Input Control Setting Communication Analog Inputs Digital Inputs Analog Total : input 0-0V, 0-0mA, input 0-0V Total 5: inputs khz, input 50kHz Up to : output 0-0V, 0-0mA.kW/HP, (nd output available from >.kw/hp) MODBUS, Analog, Digital, PID, Pulse MODBUS RTU RS-5 Total : inputs 0-0V, 0-0mA, input 0-0V Total 9: inputs khz, input 50kHz outputs 0-0V, 0-0mA Output Digital output sink/source Total : output sink/source, output 50kHz Relay Up to : Programmable Multi-functional output. nd output available from >.kw/hp Total Programmable Multi-functional outputs Use as an All-in-One package Program the using the same programming software as our controllers: UniStream, Vision and Samba Features Dynamic Braking Unit Built-in ( 7kW/50HP) Optional (>7kW/50HP) Built-In C ( kw/5hp), Comply with IEC/EN 600- Optional C (<kw/5hp), Comply with IEC/EN 600- Built-in ( 0kW/0HP) Optional (>0kW/0HP) Built-In C, Comply with IEC/EN 600- EMC Filters Optional C, Comply with IEC/EN 600- Operating Temperature (-0) C/ F 50 C/ F (de-rated by % for every C/ F above 0 C/0 F) Altitude 000m/6600 ft (de-rated by % for every additional 00m/0ft above 000m/00ft) Enclosure Rating IP0 Dynamic configuration Control Scope Trace General Mounting Options Wall and Rail (.kw/hp) Wall and Flange (>.kw/hp) Wall, Flange Cooling Air-cooling Safe Torque Off Compliance CE, TUV-SUD Safety Mark CE, UL and cul 9

UniStream Series Vision TM Series Samba TM Series Jazz Series Models UMI-B Series - STO Article Number UMI-000BE-B Input Voltage Rated Output Power kw HP Optional Parts Rated Input Current (A( Rated Output Current (A( Dimensions 0. 0.5 6.5.5 0 60 UMI-0007BE-B Single 0.75 9.. 0 60 phase UMI-005BE-B 00-0V.5 5.7 7.5 0 5 UMI-00BE-B. 0 0 5 UMI-0007EE-B 0.75..5 0 5 UMI-005EE-B.5 5. 0 5 UMI-00EE-B. 5. 5.5 0 5 UMI-000EE-B 5.5 9.5 6 56 67 UMI-0055EE-B 5.5 7.5 9.5 6 56 67 UMI-0075EE-B 7.5 0 5.5 70 0 97 UMI-00EE-B 5 5 70 0 97 UMI-050EE-B Three 5 0 0 70 0 97 UMI-05EE-B phase.5 5 7 00 5 UMI-00EE-B 0-0V 0 5 5 00 5 UMI-000EE-B 0 0 70 60 50 00 0 UMI-070EE-B 7 50 0 75 50 00 0 UMI-050EE-B 5 60 9 9 560 UMI-0550EE-B 55 75 5 560 UMI-0750EE-B 75 00 9 50 560 UMI-0900EE-B 90 0 6 0 55 0 UMI-00EE-B 0 50 0 5 55 0 External Keypads Flange Mounting Plates Braking Resistors C Input Filters C Filters )W x H x D mm( Product Designation Key No. Key Description 5 UMI - 00 E U - B 5 Product Line Power Range Power Rating Certification Product series Unitronics Motion Inverters 000:00W/0.5HP 00:.kW/HP B: PH 00V 0V C: PH 00V 0V E: PH 0V 0V/0V U UL Certified E TUV-SUD Certified B / B5 Safety Class Class SIL PLd CAT. Class SIL PLd CAT. Class SIL PLe CAT. UMI-B Series - UL Article Number UMI-000BU-B UMI-B5 Series - UL Input Voltage kw Rated Output Power HP Rated Input Current (A( Rated Output Current (A( Dimensions 0. 0.5 6.5.5 0 60 UMI-0007BU-B Single phase 0.75 9.. 0 60 UMI-005BU-B 00-0V.5 5.7 7.5 0 5 UMI-00BU-B. 0 0 0 5 UMI-000CU-B Three phase 0. 0.5.7.5 0 5 UMI-0007CU-B 00-0V 0.75 5. 0 5 UMI-0007EU-B 0.75..5 0 5 UMI-005EU-B Three phase 0-0V.5 5. 0 5 UMI-00EU-B. 5. 5.5 0 5 Article Number UMI-0007CU-B5 Input Voltage kw Rated Output Power HP Rated Input Current (A( Rated Output Current (A( Dimensions 0.75 5.5 6 9 75 UMI-005CU-B5.5 7.7 7 6 6 UMI-00CU-B5. 0 6 6 UMI-000CU-B5 5 7 6 70 6 UMI-0055CU-B5 5.5 7.5 0 70 6 UMI-0075CU-B5 7.5 0 0 0 6 UMI-00CU-B5 Three phase 5 55 07 5 UMI-050CU-B5 00-0V 5 0 56 55 55 07 5 UMI-05CU-B5.5 5 7 70 70 555 5 UMI-00CU-B5 0 0 70 555 5 UMI-000CU-B5 0 0 0 70 555 5 UMI-070CU-B5 7 50 0 5 60 65 UMI-050CU-B5 5 60 6 60 5 60 65 UMI-0550CU-B5 55 75 00 00 5 60 65 UMI-005EU-B5 )W x H x D mm( )W x H x D mm(.5 5.7 6 9 75 UMI-00EU-B5. 5. 5 6 9 75 UMI-000EU-B5 5.5 9.5 6 6 UMI-0055EU-B5 5.5 7.5 9.5 6 6 UMI-0075EU-B5 7.5 0 5.5 70 6 UMI-00EU-B5 5 5 70 6 UMI-050EU-B5 5 0 0 0 6 UMI-05EU-B5 Three phase.5 5 7 0 6 UMI-00EU-B5 0-0V 0 56 5 55 07 5 UMI-000EU-B5 0 0 70 60 55 07 5 UMI-070EU-B5 7 50 0 75 70 555 5 UMI-050EU-B5 5 60 9 9 70 555 5 UMI-0550EU-B5 55 75 5 70 555 5 UMI-0750EU-B5 75 00 60 50 5 60 65 UMI-0900EU-B5 90 0 90 0 5 60 65 UMI-00EU-B5 0 50 5 5 5 60 65 0

Fast. Easy. Cost-effective Unitronics integrated solution for control & automation offers the best of two worlds: broad choice and flexibility in choosing solution components together with the simplicity and time-savings of an all-inclusive, single-vendor solution. Working with the Unitronics combined PLC and HMI make other systems feel old fashioned and obsolete. The support from Unitronics, from our local supplier, to email support, to help ideas on the forum, has been absolutely fantastic. Justin Butler, Energy Plant Solutions After programming several other brands of PLCs, Unitronics software is by far the most intuitive and easily understood while providing significant functionality and quality. Complete range of PLC + HMI Dan Murphy, Owner of Marathon Bottling and Automation Using the Unitronics products, I am able to provide technologically advanced products and services that provide competitive advantages to my clients in terms of quality, efficiency, performance, safety, cost savings, and improved asset utilization of the plan floor. Jeferson Franco, an Engineer at AI7 Automation Ltda. Outstanding Support

To Find Your Local Distributor, Visit Our Website: UnitronicsPLC.com Where To Buy The information in this document reflects products at the date of printing. Unitronics reserves the right, subject to all applicable laws, at any time, at its sole discretion, and without notice, to discontinue or change the features, designs, materials and other specifications of its products, and to either permanently or temporarily withdraw any of the forgoing from the market. All information in this document is provided as is without warranty of any kind, either expressed or implied, including but not limited to any implied warranties of merchantability, fitness for a particular purpose, or non-infringement. Unitronics assumes no responsibility for errors or omissions in the information presented in this document. In no event shall Unitronics be liable for any special, incidental, indirect or consequential damages of any kind, or any damages what so ever arising out of or in connection with the use or performance of this information. The trade names, trademarks, logos and service marks presented in this document, including their design, are the property of Unitronics (99) (R G) Ltd. or other third parties and you are not permitted to use them without the prior written consent of Unitronics or such third party as may own them. GEN005-A www.unitronicsplc.com International Headquarters: P.O.B. 00, Ben Gurion Airport 709900, Israel. Tel: +97 977, Fax: +97 977 77, global.sales@unitronics.com