Active UTP Transceiver Hub with Integral Camera Power Installation Guide

Similar documents
Active UTP Transceiver Hub with Integral Isolated Camera Power Installation Guide

Transceiver Hub with Integral Camera Power

Passive UTP Transceiver Hub with Integral Isolated Camera Power Installation Guide

Active UTP Transceiver Hub with Integral Camera Power Installation Guide

Passive UTP Transceiver Hub with Integral Camera Power Installation Guide

Active UTP Transceiver Hub with Integral Isolated Camera Power

Passive UTP Transceiver Hub Installation Guide

Rack Mount Power Supplies

AL168 Series Multi-Output Power Supplies

PoE Managed Midspan Solution for Standard Network Infrastructure

DC Outdoor Power Supply/Chargers

OWNER S MANUAL SINGLE CAT5E/6 3D EXTENDER B-320-1CAT-HDIR

OWNER S MANUAL SINGLE CAT5E/6 3D EXTENDER B-200-1CAT-HDIR. Receiver

INSTRUCTION MANUAL DISTRIBUTION UNIT. Please read this manual thoroughly before use, and keep it handy for future reference.

Installation and Operation Manual CX452 with CHM22/CXM22

HDBaseT EXTENDER B-520-TX-230-IR B-520-TX-330-IR INSTALLATION MANUAL

E-ACLM-V E-ACLM-P12/8/18 AC LINE MONITORS Installation and Operation Manual

TVA2.1 2-Channel Digital Amplifier Installation Manual

4K HDR HDBaseT Extender B-560-EXT INSTALLATION MANUAL

5 B&W Rear View System Camera

CLFE(X)UTP INSTALLATION AND OPERATION MANUAL

CLFE(X)COAX INSTALLATION AND OPERATION MANUAL

Installation Instructions CX254 Card Cage Power Injector

1 Overview. 2 Specifications. Product Installation Document

TOT Series Manual. North American and International Models - without optional faceplate. Receptacle Panel of International Models, CE model shown

Monochrome Camera. Features. User manual

Owner s Manual. Isolate. Restore. Inspire! Power Conditioners Audio / Video Power Isolation Units Rack Mount / Consumer Series

TOT Series Manual. North American CE and UK Models. CE Models. UK Models. North American Models

U-150 Integrated Amplifier User s guide

Installation Guide. Rev

Cantata m100 Amplifier

Neets Switching Relay - 2. Installation manual

MPF-1, Mains Power Filter User Manual

OWNER S MANUAL CD-2 V 1.3

HDBaseT EXTENDER B-520-EXT-230-RS-W INSTALLATION MANUAL

OWNER S MANUAL GEQ 131/ 131LF GEQ 215/ 215LF GEQ 231. Single Channel 31 Band Graphic Equalizer. 2 Channel 15 Band Graphic Equalizer

Installation Manual. 12 Volt Power Supplies. 18-Port. 9-Port RET18PT RET9PT

Expandable Power Systems

PS8 - II. Professional Power Sequencer. User s Manual

iconverter 2-Module Power Chassis

VE8012A/VE8012AR DUAL NETWORKED STATION PORT

Roth BAR 2LX High-Power Soundbar with Wireless Subwoofer. Turn it up. Roth BAR2 LX Manual UK VJ.indd 1 19/06/ :07

AVR Manual. Isolate. Restore. Inspire! Audio / Video Power Isolation Units with Automatic Voltage Regulation. 19 Pro Series Rack Mount (RM) Faceplate

WIRELESS BLUETOOTH BOOMBOX

INSTALLATION MANUAL. HDMI 1x4 Splitter B-230-HDSPLTR-1x4. B-230-HDSPLTR-1x4 HDMI OUT 4 HDMI OUT 3 HDMI OUT 2 HDMI OUT 1 HDMI OUT 4 HDMI IN

INSTALLATION MANUAL. HDMI 1x8 Splitter B-230-HDSPLTR-1x8 B-230-HDSPLTR-1X8

Monochrome Cameras LTC 0140 LTC 0142 LTC Eng. Philips Communication & Security Systems

Quick Start Guide. C-100 Series Switches

Kogan Bluetooth Karaoke System with Dual Microphones KAKAR2MICA

Installation RA5112-C-16A-C20. Basic Rack Power Distribution Unit

YST-SW20 SUBWOOFER SYSTEM OWNER S MANUAL. Active Servo Technology

DMX Tool Splitter 1 to 5 User Manual

OWNER S MANUAL >> BINARY HD MATRIX SWITCHER B-100-HDMATRIX-4X4 / B-100-HDMATRIX-8X8

DLHD2100 Owners Manual

Accessory Packages for the Allegiant

Quick Guide. ENC-H Video Encoder XX

USB CASSETTE PLAYER MODEL NO. : GE USER MANUAL -

DVAA Series Disk Array for DVR1 Series Digital Video Recorder

Installation/ Operation Manual

FC-29W 9 UN-UNIVERSAL Dome Housing. Installation Instructions

ITEM NO: SP-001, SP-001P, SP-001VP, SP-001VPD, SP-002, SP-002VP, SP-002VPD, SP-003, SP-004, SP-004VPD, SP-005, SP-006, SP-016C, SP-016T

User Manual ABS Molded Powered Loudspeaker MODEL: PB15PKG. QUESTIONS / COMMENTS CALL or pr o.com

Digital Color Cameras

TS-VGA OWNERS MANUAL. TS-VGA_manual_en_v1

MAINTENANCE MANUAL. EDACS REDUNDANT POWER SUPPLY SYSTEM 350A1441P1 and P2 POWER MODULE CHASSIS 350A1441P3, P4, AND P5 POWER MODULES TABLE OF CONTENTS

RS232 Control Box. Table of contents

SUBWOOFER SYSTEM YST-MSW10

Industrial Camera GP-MF602. Before attempting to connect or operate this product, please read these instructions completely.

ebridge200b - Managed Two Port Transceiver Board

PRE116/126. User Manual.

Installing and Configuring Rialto Analytic Appliances

Industrial 1-Port Coax/UTP Long Reach PoE+ 4-Port. 10/100TX PoE Extender LRP-104CET. User s Manual

HDMI 1x2 Splitter B-230-HDSPLTR-1x2 INSTALLATION MANUAL HDMI OUT 2 HDMI OUT 1 B-230-HDSPLTR-1X2 POWER HDMI IN

ST-C5VRS-600 VIDEO AND RS232 EXTENDER Installation and Operation Manual

SOUNDSTICKS WIRELESS. Setup Guide. Downloaded from

OPERATIONS MANUAL. n.form I/O Expander (RACK MOUNT) Document Number: Rev B

VMI. Technical Documentation. 600 Industrial Drive, New Bern, N.C (tel / fax /

HMXAT200 Series System Controller

Isobar 12-Outlet Network Server Surge Protector, 15 ft. Cord, 3840 Joules, Diagnostic LEDs, 1U Rack-Mount, Metal Housing

SoundwebTM. Installation Guide

INSTRUCTION MANUAL. Security Camera. Indoor/Outdoor Color Camera w/ Night Vision. Version 1.0. now you can see. Model# VU5

APT20. User Manual.

This 4200-RM Rack Mount Kit is for installation in 4200-CAB series cabinets only.

MP SERIES PROFESSIONAL POWER AMPLIFIER

MODEL GE4138 DIGITAL CD/MP3/USB/SD ENCODING WITH PLL AM/FM ALARM CLOCK STEREO RADIO - USER MANUAL -

Passive CCTV Hub Plus (500134) Installation Guide

7 LCD CCTV Test monitor. Quick guide

CF /BF SERIES CAMERAS

BCM2 Series Branch Circuit Monitors Quick Setup Guide

WARNING RISK OF ELECTRIC SHOCK DO NOT OPEN

PS-20. Power Supply. User Manual Rev F

Roth BAR 2LX High-Power Soundbar with Wireless Subwoofer. Turn it up.

IA1000. Integrated Amplifier with USB / SD Inputs IA1000. QUESTIONS/COMMENTS CALL or

Installing the Cisco 2524 and Cisco 2525 Routers

C-300 Preamplifier User s guide

MODEL 805 USER MANUAL

VIP-804 QUAD ENHANCED NETWORK AUDIO PORT

Daily use. indicating that the loud speakers

HDMI MATRIX SWITCHER B-120-HDMATRIX-4x4/8x8 CONFIGURATION UTILITY MANUAL

Surge Protection for Surveillance Systems

Transcription:

Active UTP Transceiver Hub with Integral Installation Guide Models Include: HubWayLD8CDS - UL Listed eight (8) Channel Active UTP Transceiver Hub with Integral HubWayLD82CDS - UL Listed eight (8) Channel Active UTP Transceiver Hub with Integral - Includes eight (8) UL Listed Accessory HubWayAv Balun/s HubWayLD83CDS - UL Listed eight (8) Channel Active UTP Transceiver Hub with Integral - Includes eight (8) UL Listed Accessory HubWayDv Balun/s Rev. 071508 More than just power. TM

Overview: Altronix HubWayLD8CDS Passive UTP Transceiver Hub w/integral transmits UTP video, RS422/RS485 data and power over a single or higher structured cable. Unit provides 8 camera channels in a space saving 1U EIA 19 rack mount chassis which may be rack, wall or shelf mounted. transmission range is up to 3000 ft. max. per channel. Units are compatible with AC and/or DC fixed or PTZ cameras when utilizing Altronix HubWayAv, HubWayDv or HubWayDvi Balun/s. In addition, the unit features individually selectable 24VAC or 28VAC, PTC protected outputs with surge suppression. An optional HubSat4D Passive UTP Transceiver Hub with Integral unit can be used as an accessory module to transmit video from up to 4 cameras over a single or higher structured cable back to the HubWayLD8CDS. In addition, the HubSat4D units provide power to these cameras locally to eliminate the possibility of voltage drop associated with long cable runs. Agency Listings: UL Listed for Commercial CCTV Equipment (UL 2044). CUL Listed - CSA Standard C22.2 No.1-04, Audio, and Similar Equipment. Input: 115VAC 60Hz, 1.5 amp. : Eight (8) channels of video over twisted pair up to a distance of 3000 ft. Eight (8) 75 ohm video outputs. : RS422/RS485 data inputs. : Individually selectable 24VAC or 28VAC power outputs with OFF position. Unit provides up to 1 amp max. per channel not to exceed a total of 5 amp (150VA) maximum current. PTCs are rated @ 1 amp per channel. Surge suppression. HubWayLD8CDS Specifications: Visual Indicators: AC input power indicator. Eight (8) power LED indicators. Features: Picture and Gain control. Illuminated master power disconnect circuit breaker with manual reset. IEC 320-3-wire grounded line cord (detachable). Unit can be rack, wall or shelf mounted. 1U rack mount chassis for use in standard EIA 19 rack. Accessories: Balun/s: - HubWayAv - for use with 24VAC cameras. - HubWayDv - for use with 12VDC cameras. - HubWayDvi - for use with non-isolated 12VDC cameras. Optional HubSat4D allows transmission of up to four (4) video signals over a single or higher structured cable. Additional Models: HubWayLD82CDS HubWayLD8CDS with eight (8) UL Listed Accessory HubWayAv Balun/s for 24VAC s. HubWayLD83CDS HubWayLD8CDS with eight (8) UL Listed Accessory HubWayDv Balun/s for 12VDC s. WARNING: To reduce the risk of fire or electric shock, do not expose the unit to rain or moisture. This installation should be made by qualified service personnel and should conform to all local codes. Installation Instructions: 1. Attach mounting brackets to the HubWayLD unit for rack or wall mount installation (Figs. 6-7, pg. 8). Affix rubber pads to the HubWayLD unit for shelf installation (Fig. 8, pg. 8). 2. Secure the unit in a rack, mount unit to a wall or place unit on a shelf as desired (unit should be spaced at least 3 from any video monitors). 3. Set illuminated master power disconnect circuit breaker to the (OFF) position (Fig. 5, pg. 7). 4. Plug the grounded AC line cord (included) into the IEC 320 connector of the HubWayLD8CDS unit (Fig. 1f, pg. 4). Insert the plug end of the line cord into a grounded AC receptacle. 5. Set voltage output selector switch of each camera channel for 24VAC or 28VAC (Fig. 1a, pg. 4). 6. Connect the BNC video outputs for HubWayLD8CDS Channels 1-8 to the corresponding video inputs on the head end equipment (DVR) (Fig. 1d, pg. 4). - 2 - HubWayLD Active Unit

7. Connect the RS422/RS485 output of the head end equipment (DVR) to the data input terminal block of the HubWayLD8CDS unit (polarity must be observed) (Fig. 1c, pg. 4). 8. Connect Balun/ at camera 1 to the HubWayLD8CDS unit utilizing or higher structured cable. Plug the RJ45 connector at one end of the structured cable into the RJ45 jack marked [Channel 1] of the HubWayLD8CDS (Fig. 1h, pg. 4). Plug the RJ45 connector at the opposite end of the structured cable into the RJ45 jack of the Balun/ located at camera 1. For 24VAC cameras use Altronix model HubWayAv Balun/ (Figs. 2a, 2b, pg. 5). For 12VDC cameras use Altronix model HubWayDv Balun/ (Figs. 2c, 2d, pg. 5). For non-isolated 12VDC cameras use Altronix model HubWayDvi Balun/ (Figs. 2c, 2d, pg. 5). Repeat steps 6-9 for each additional camera (Channels 2-8). Note: When a particular camera exceeds the maximum distance for power transmission, a local external power source is required. Optionally, an Altronix HubSat4D Passive UTP Transceiver Hub with Integral unit may be utilized (Fig. 4a, pg. 6). The combined total cable distance must not exceed 3000 ft. for video transmission between the HubWayLD8CDS and each camera routed through the HubSat4D. 9. Set illuminated master power disconnect circuit breaker to the RESET (ON) position (Fig. 5, pg. 7) and measure the output voltage at the power output of each Balun/ (Figs. 2b, 2d, pg. 5) before powering each camera to insure proper operation and avoid possible damage. HubWayAv - Terminals marked [AC POWER] (Figs. 2a, 2b, pg. 5). HubWayDv/HubWayDvi - Terminals marked [ 12VDC +] (Figs. 2c, 2d, pg. 5). 10. Set illuminated master power disconnect circuit breaker to the (OFF) position to make the final connections (Fig. 5, pg. 7). 11. Connect the power outputs of the HubWayAv, HubWayDv or HubWayDvi Balun/s to the power inputs of the cameras (Figs. 2a-2d, pg. 5). Polarity must be observed. 12. Connect the terminals marked [+ DATA --] of the HubWayAv, HubWayDv or HubWayDvi Balun/s to the data terminals of the cameras for PTZ control (Figs. 2a-2d, pg. 5). Polarity must be observed. When using fixed cameras disregard this step. 13. Connect the BNC connector of the HubWayAv, HubWayDv or HubWayDvi Balun/s to the BNC video outputs of the cameras (Figs. 2a-2d, pg. 5). 14. Upon completion of wiring set illuminated master power disconnect circuit breaker to the RESET (ON) position (Fig. 5, pg. 7). 15. The power LEDs (Red) located on the front of the HubWayLD8CDS will illuminate when AC power is present (Fig. 1c, pg. 4). 16. AC LEDs (Green) of the HubWayAv or DC LEDs (Red) of the HubWayDv/HubWayDvi Balun/s will illuminate indicating power is present at the cameras (Fig. 2b, 2d, pg. 5). 17. The video signal indicator LEDs (Red) located on the rear of the HubWayLD8CDS will illuminate when video signal is present (Fig. 1i, pg. 4). If any of these LEDs are not illuminated, no video signal is present for that corresponding channel. Note: If any of these LEDs are not illuminated either a voltage output selector switch is in the OFF position or the PTC is tripped for that channel. To reset the PTC: 1. Set the voltage output selector switch for that corresponding channel to the OFF position. Switch must remain in the OFF position for approximately 2 minutes in order for the PTC to reset. 2. Eliminate the trouble condition (short circuit or overload). 3. Set the voltage output selector switch for 24VAC or 28VAC (Fig. 1a, pg. 4). 18. Optimize the picture quality for all camera channels by adjusting the corresponding potentiometers marked [Picture] (Fig. 1g, pg. 4). 19. Set gain for all camera channels by adjusting the corresponding potentiometers marked [Gain] (Fig. 1h, pg. 4). HubWayLD Active Unit - 3 -

input from Head End Equipment (DVR). + -- 1c - : Removable terminal blocks for RS422/ RS485 input from head end equipment (DVR) for PTZ control. 1f - IEC 320 Connector: 115VAC 60Hz (grounded line cord included). 1e - LED(s) 1-8: signal indicators. 1d - BNC Connector: outputs to head end equipment (DVR). 1b - LED(s) 1-8: indicators. 8 7 6 5 4 3 2 1 1 2 AC POWER PICTURE GAIN PICTURE GAIN PICTURE GAIN PICTURE GAIN PICTURE GAIN PICTURE GAIN PICTURE GAIN PICTURE GAIN 1j - Gain: Regulates the output video and sync levels. 1i - Picture: Adjusts video quality. 1h - Channels 1-8: or higher structured cable to /Balun s at cameras 1-8. When linking HubWay UTP Transceiver Hubs to HubSat Remote Accessory Modules, any of these jacks will facilitate data transmission for PTZ control. Fig. 1 Top View 1a - Output voltage switches: Selects 24VAC/28VAC/OFF for each output. Rear -- DATA + 24VAC OFF 28VAC - 4 - HubWayLD Active Unit 3 4 1-8 8 7 6 5 CH 1-4 CH 5-8 1g - Channels 1-4 & Channels 5-8: Links HubSat units enabling video transmission of up to four (4) cameras over a single structured cable.

Altronix Model Number Fig. 2 Fig. 2a HubWayAv, HubWayDv and HubWayDvi Balun/s: VIDEO Input Voltage from HubWay unit HubWayAv VIDEO BALUN/COMBINER CAT5 AC + DATA-- POWER Output Voltage to camera Fig. 2c Type HubWayAv *24VAC/28VAC *24VAC/28VAC 24VAC cameras Green HubWayDv *24VAC/28VAC 12VDC 12VDC cameras Red HubWayDvi *24VAC/28VAC 12VDC electronically isolated 12VDC cameras without isolation Red *Based on camera load and structured cable length. VIDEO HubWayDv VIDEO BALUN/COMBINER CAT5 + DATA-- -- 12VDC+ LED * Also Available as: HubWayDvi Balun/ for non-isolated 12VDC cameras RJ45 Jack Wire Connectors RJ45 Jack Wire Connectors Fig. 2b Fig. 2d To BNC Connector of Structured Cable from HubWayLD8CDS Green LED AC to To BNC Connector of Structured Cable from HubWayLD8CDS Red LED + 12VDC -- to -- to + -- to + HubWayAv passes AC voltage from pins 4, 5, 7, 8 to terminals marked [AC ] (Fig. 3, pg. 5). HubWayDv/HubWayDvi converts AC voltage to DC voltage from pins 4, 5, 7, 8 to terminals marked [--12VDC +] (Fig. 3, pg. 5). Fig. 3 - Structured Cable Wiring Color Codes and PIN Configurations 1 - White/Orange [VIDEO +] 2 - Orange [VIDEO -- ] 3 - White/Green [DATA +] 4 - Blue [AC 1] 5 - White/Blue [AC 2] 6 - Green [DATA -- ] 7 - White/Brown [AC 2] 8 - Brown [AC 1] HubWayLD Active Unit - 5 -

Fig. 4 Typical Applications: Monitor Head End Equipment (DVR) RS485 -- DATA + 24VAC OFF 28VAC 1-8 CH 5-8 8 CH 1-4 8 7 6 5 4 3 2 1 PICTURE GAIN PICTURE GAIN PICTURE GAIN PICTURE GAIN PICTURE GAIN PICTURE GAIN PICTURE GAIN PICTURE GAIN AC POWER PTZ Fixed HubWayDv/Dvi Balun HubWayDv/Dvi Balun Four (4) signals on a single () 24VAC/28VAC Provided by HubSat4D 115VAC Input, 50/60Hz HubWayAv Balun (Coax) PTZ Max. video 3000 ft. PTZ Fixed HubWayAv Balun HubWayAv Balun Outdoor PTZ Fixed HubWayDv/Dvi Balun HubWayAv or HubWayDv/Dvi Balun Fixed Fig. 4a - Optional hookup utilizing HubSat4D. IEC 320 Connector 115VAC 60 Hz 7 6 5 4 3 2 1-6 - HubWayLD Active Unit

1U EIA 19 Rack Mount Chassis Mechanical Drawing & Dimensions: 1.625 H x 19.125 W x 8.5 D REAR -- DATA + 24VAC OFF 28VAC 1.625" CH 5-8 1-8 8 7 6 5 CH 1-4 4 3 2 1 8 7 6 5 4 3 2 1 PICTURE GAIN PICTURE GAIN PICTURE GAIN PICTURE GAIN PICTURE GAIN PICTURE GAIN PICTURE GAIN PICTURE GAIN AC POWER TOP & BOTTOM 17.625" 8.5" FRONT 19.125".75" Fig. 5 Illuminated master power disconnect circuit breaker: OFF position Circuit breaker tripped Switch not illuminated. RESET (ON) position Switch illuminated. The lightning flash with arrow head symbol within an equilateral triangle is intended to alert the user to the presence of an insulated DANGEROUS VOLTAGE within the products enclosure that may be of sufficient magnitude to constitute an electric shock. The exclamation point within an equilateral triangle is intended to alert the user to the presence of important operating and maintenance (servicing) instructions in the literature accompanying the appliance. CAUTION: To reduce the risk of electric shock do not open enclosure. There are no user serviceable parts inside. Refer servicing to qualified service personnel. HubWayLD Active Unit - 7 -

Mounting Options: Rack Mount Installation 1- Remove and discard factory installed screws from both sides of rack chassis (Fig. 6a). 2- Install mounting brackets (A) on the left and right side of rack chassis using the four (4) flat head screws (B) (included) (Fig. 6b). 3- Place unit into desired EIA 19 rack position and secure with mounting screws (not included) (Fig. 6c). Fig. 6 Fig. 6a Fig. 6b Fig. 6c Top Top Top Front Left B Front Left Front Left Remove A Wall Mount Installation 1- Install mounting brackets (A) on the left and right side of rack chassis using four (4) flat head screws (B) (included) (Fig. 7a). 2- Place unit at desired location and secure with mounting screws (not included) (Fig. 7b). Fig. 7 Caution: It is necessary to Fig. 7a Fig. 7b make sure mounting screws are securely fastened to a beam when installing the unit vertically. B A Dotted lines indicate studs behind sheetrock. Shelf Installation 1- Position and affix rubber pads (C) (included) at each corner on the bottom of the unit (Fig. 8). 2- Place unit in desired location. Fig. 8 Altronix is not responsible for any typographical errors. C Left Side Rubber Pad Mounting Hardware (Included): A B C Two (2) mounting brackets Six (6) flat head screws for mounting brackets. Four (4) rubber pads. 140 58th Street, Brooklyn, New York 11220 USA, 718-567-8181, fax: 718-567-9056 website: www.altronix.com, e-mail: info@altronix.com, Lifetime Warranty, Made in U.S.A. IIHubWayLD8CDS A14I MEMBER - 8 - HubWayLD Active Unit