SCC-AO10 Isolated Analog Output Module

Similar documents
SCC-RLY01 Relay Module

SCXI -1313A Terminal Block

NI TB Introduction. Conventions INSTALLATION INSTRUCTIONS Wire Terminal Block for the NI PXI-2529

TBX-1316 High-Voltage Attenuator Terminal Block

Electrical. SPECIFICATIONS SH Cable

8x16, 2-Wire Terminal Block for the NI PXI The following conventions are used in this guide:

NI PXI-1042 Series Power Supply Shuttle

SCXI OFFSET-NULL AND SHUNT-CALIBRATION HIGH-VOLTAGE TERMINAL BLOCK INSTALLATION GUIDE

NI USB Introduction USER GUIDE AND SPECIFICATIONS. 4-Channel, ±10 V, 16-Bit Analog Voltage Output Module

SH Cable Specifications

NI 6521 Specifications

INSTALLATION INSTRUCTIONS NI TB-2630B Terminal Block for the NI PXI-2530B. Contents. Introduction

NI PXI-2567 Specifications

INSTALLATION INSTRUCTIONS SH160F-160M-NI SwitchBlock Cable

This installation guide describes how to install and connect signals to the NI TBX-2808 screw terminal accessory for use with NI SwitchBlock cards.

OPERATING INSTRUCTIONS AND SPECIFICATIONS. NI 9208E 16-Channel, ±20 ma, 24-Bit Analog Input Module

8 AI (12-Bit, 10 ks/s), 2 AO (150 Hz), 12 DIO USB Multifunction I/O Device

OPERATING INSTRUCTIONS AND SPECIFICATIONS NI 9476E. 32-Channel, 24 V Sourcing Digital Output Module

Warranted specifications describe the performance of a model under stated operating conditions and are covered by the model warranty.

NI What You Need to Get Started. Unpacking INSTALLATION GUIDE. This document explains how to set up your NI 8262 expansion module.

SPECIFICATIONS AND FEATURES GUIDE NI Serial Legacy Hardware

USB Definitions. Conditions. Analog Input SPECIFICATIONS. 8 AI (10 ks/s), 4 DIO USB Multifunction I/O Device

NI SMB-2145/2146/2147/2148

TBX-96 TERMINAL BLOCK

NI Serial Hardware Specifications Guide

Where to Start with NI ELVIS

OPERATING INSTRUCTIONS AND SPECIFICATIONS NI 9870E

Warranted specifications describe the performance of a model under stated operating conditions and are covered by the model warranty.

Where to Start with NI ELVIS

OPERATING INSTRUCTIONS AND SPECIFICATIONS NI 9871E

NI TSM-101x. LCD Characteristics NI TSM-1012 NI TSM-1015 SPECIFICATIONS. NI TSM-1012, NI TSM-1015, NI TSM-1017 Touch Screen Monitors

You need the following to set up and use your terminal block:

OPERATING INSTRUCTIONS AND SPECIFICATIONS NI Channel, Sinking Digital Input/Sourcing Digital Output Module. ni.

RTM Contents. Definitions. Conditions SPECIFICATIONS. High-Speed Serial Rear Transition Module for ATCA

NI USB Introduction USER GUIDE AND SPECIFICATIONS. 4-Channel, 0 20 ma, 16-Bit Analog Current Output Module

NI Channel, 0 20 ma, 16-Bit Analog Current Output Module

GETTING STARTED GUIDE NI AO, 0 ma to 20 ma, 16 Bit Simultaneous

USER GUIDE I/O Accessory For the NI PCIe-8237R GigE Vision Interface Device

NI SD Card Memory Module

RTM Contents. Definitions. Conditions SPECIFICATIONS. PCI Express Rear Transition Module for ATCA

1-Wire 4 x 128 Matrix Terminal Block for the NI PXI/PXIe-2532B

These specifications apply to the 1 m and 3 m TriaxM-TriaxM. it in a manner not described in this document.

IVN Safety Guidelines GETTING STARTED GUIDE. 100BASE-T1 Media Converter

NI 6581/6581B Specifications

GETTING STARTED GUIDE NI Channel, 50 Arms Continuous, 24-Bit, Analog Input Module

1- or 2-Port, High-Speed/FD, USB CAN Interface Device

INSTALLATION GUIDE AND TERMINAL BLOCK SPECIFICATIONS NI PXIe-4322 and TB Channel, Isolated Voltage/Current Analog Output Module

GETTING STARTED GUIDE NI V, 32-Channel (Sinking Input), 7 µs C Series Digital Module

INSTALLATION GUIDE AND TERMINAL BLOCK SPECIFICATIONS NI PXIe-4357 and TB-4357

SCB-68 User Guide. 68-Pin Shielded Desktop Connector Block

NI 9375 DATASHEET. 16 DI/16 DO, 30 VDC, 7 μs Sinking DI, 500 μs Sourcing DO

NI CAN Demo Box. NI CAN Demo Box User Guide. Power supply (+9 VDC to +12 VDC) 68-pin Multifunction Data Acquisition board

NI USB Introduction USER GUIDE AND SPECIFICATIONS. 8-Channel, 24 V Logic, Sinking Digital Input Device

Low-Cost Multifunction DAQ for USB

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

illustrate the performance of a representative module.

NI PXIe-7971R. Contents DEVICE SPECIFICATIONS. NI FlexRIO FPGA Module for PXI Express

The following conventions appear in this document:

NI PXIe-7976R. Contents DEVICE SPECIFICATIONS. NI FlexRIO FPGA Module for PXI Express

NI crio-9101/9102/9103/9104

NI USB-9201/9221. Introduction USER GUIDE AND SPECIFICATIONS. 8-Channel, 12-Bit Analog Input Devices

ATCA Contents. Definitions SPECIFICATIONS. FPGA Module for ATCA

Getting Started with the NI PCIe-8253

NI 9269 DATASHEET. 4 AO, ±10 V, ±40 V Stacked, 16 Bit, 100 ks/s/ch Simultaneous

NI REM Remote I/O Overview DATASHEET. Analog Output Module for Remote I/O

1 Gbps, 20 Channel, LVDS Digital I/O Adapter Module

GETTING STARTED GUIDE NI Channel, 60 V, High-Speed, Sourcing Digital Output Module

GETTING STARTED GUIDE NI Channel Solid-State Relay (SSR) Digital Output Module

Getting Started with the NI 8234

NI PXI Contents CALIBRATION PROCEDURE

USER GUIDE AND TERMINAL BLOCK SPECIFICATIONS NI PXIe-4340 and TB Ch, 24-bit, 25.6 ks/s Simultaneous AC LVDT Input Module

NI 9472 DATASHEET. 8 DO, 6 V to 30 V, Sourcing, 100 μs

USER GUIDE Universal Motion Interface (UMI)-7764

NI 9201 DATASHEET. 8 AI, ±10 V, 12 Bit, 500 ks/s Aggregate

Getting Started with the NI PCIe-1433

USB-2001-TC. USB-based Thermocouple Input. User's Guide

FP-AO-210 AND CFP-AO-210

NI 6703/6704 Calibration Procedure for NI-DAQ mx

NI REM Remote I/O Overview DATASHEET. Digital Input Module for Remote I/O

Electromagnetic Compatibility Guidelines

NI 9213 Calibration Procedure

36 V, 32-Channel (Sourcing Output), 500 µs C Series Digital Module. DSUB are referred to inclusively as the NI 9476.

NI 9402 DATASHEET. 4 DIO, LVTTL, Bidirectional, 55 ns. BNC connectivity CompactDAQ counter compatibility Individually configurable channel directions

Compact Vision System with USB3 Vision and Reconfigurable I/O

USER GUIDE AND SPECIFICATIONS NI myrio-1950

INSTALLATION GUIDE AND TERMINAL BLOCK SPECIFICATIONS NI PXIe-4339 and TB-4339/B/C 8 Ch, 24-bit, 25.6 ks/s Universal Bridge Input Module

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

NI 9223 Datasheet DATASHEET. 4 AI, ±10 V, 16 Bit, 1 MS/s/ch Simultaneous

FP-AO-200 AND CFP-AO-200

NI USB Introduction USER GUIDE AND SPECIFICATIONS. 8-Channel, 24 V Logic, Sourcing Digital Output Device

OPERATING INSTRUCTIONS AND SPECIFICATIONS NI Stepper Drive. ni.com/manuals

Electromagnetic Compatibility Guidelines

Electromagnetic Compatibility Guidelines

NI 9220 DATASHEET. 16 AI, ±10 V, 16 Bit, 100 ks/s/ch Simultaneous

GETTING STARTED GUIDE NI AI, 100 S/s/ch Simultaneous, Universal Measurements

Electromagnetic Compatibility Guidelines

NI-DAQ mx Base 1.x. Contents GETTING STARTED GUIDE

SCXI -1104/C. Contents CALIBRATION PROCEDURE. For NI-DAQmx

NI REM Remote I/O Overview DATASHEET. Digital Output Module for Remote I/O

FP-AIO-600 and cfp-aio-600

Transcription:

USER GUIDE SCC-AO10 Isolated Analog Output Module Conventions The SCC-AO10 is an isolated voltage output module with an output range of ±10 V. The output voltage level is controlled by the DAC output of an E/M Series DAQ device. You can increase the output voltage level to ±20 V by connecting two SCC-AO10 modules in series. The following conventions are used in this guide:» The» symbol leads you through nested menu items and dialog box options to a final action. The sequence File»Page Setup»Options directs you to pull down the File menu, select the Page Setup item, and select Options from the last dialog box. This icon denotes a note, which alerts you to important information. This icon denotes a caution, which advises you of precautions to take to avoid injury, data loss, or a system crash. When this symbol is marked on the product, refer to the Read Me First: Safety and Radio-Frequency Interference document, shipped with the product, for precautions to take. When symbol is marked on a product it denotes a warning advising you to take precautions to avoid electrical shock. When symbol is marked on a product it denotes a component that may be hot. Touching this component may result in bodily injury. bold italic Bold text denotes items that you must select or click in the software, such as menu items and dialog box options. Bold text also denotes parameter names. Italic text denotes variables, emphasis, a cross-reference, an introduction to a key concept, or text as it appears on a hardware label. Italic text also denotes text that is a placeholder for a word or value that you must supply.

monospace SC-2345 SCC Text in this font denotes text or characters that you should enter from the keyboard, sections of code, programming examples, and syntax examples. This font is also used for the proper names of disk drives, paths, directories, programs, subprograms, subroutines, device names, functions, operations, variables, filenames, and extensions. SC-2345 refers to both the SC-2345 connector block and the SC-2345 with configurable connectors. SCC refers to any SCC Series signal conditioning module. What You Need to Get Started To set up and use the SCC-AO10, you need the following items: Hardware SC-2345/2350 with one of the following: SCC-PWR01 SCC-PWR02 and the PS01 power supply SCC-PWR03 (requires a 7 to 42 VDC power supply, not included) One or more SCC-AO10 68-pin E/M Series DAQ device 68-pin cable Quick Reference Label Software The latest version of NI-DAQmx Documentation SCC-AO10 Isolated Analog Output Module User Guide SC-2345/2350 User Manual SCC Quick Start Guide Read Me First: Safety and Radio-Frequency Interference Documentation for your hardware Documentation for your software Tools 1/8 in. flathead screwdriver Numbers 1 and 2 Phillips screwdrivers Wire insulation stripper SCC-AO10 Isolated Analog Output Module User Guide 2 ni.com

Note Software scaling of measurements is not supported on the Macintosh operating system. Refer to the SCC-AO10 Connector Pin Assignments section. Device Specific Information You can download NI documents from ni.com/manuals. To download the latest version of NI-DAQmx, click Download Software at ni.com. Note For general SCC module installation and signal connection information, and information about the SC-2345/2350 carrier, refer to the SCC Quick Start Guide, available for download at ni.com/manuals. Installing the SCC-AO10 Caution Refer to the Read Me First: Safety and Radio-Frequency Interference document before removing equipment covers or connecting/disconnecting any signal wires. Plug the SCC-AO10 into either SC-2345/2350 analog output socket J(X+17), where X is 0 or 1. The SC-2345/2350 routes the voltage output of E/M Series DAQ device analog output channel AO (X) to the SCC-AO10. Connecting the SCC-AO10 to a Load Caution Refer to the Read Me First: Safety and Radio-Frequency Interference document before removing equipment covers or connecting/disconnecting any signal wires. Note The signal names have changed. Refer to ni.com/info and enter rdtntg to confirm the signal names. The SCC-AO10 has a three-pin screw-terminal connector that accepts 28 to 16 AWG wires. The screw terminals are labeled by pin numbers 1 to 3. Pin 1 is the isolated ground. Pins 2 and 3 both connect to the isolated voltage output for flexibility in field wiring. Caution Connecting an external voltage source to the output terminals of the SCC-AO10 may damage the module. National Instruments Corporation 3 SCC-AO10 Isolated Analog Output Module User Guide

Figures 1 and 2 show the SCC-AO10 connected to a nonreferenced load and to a load with a high common-mode voltage. E/M Series DAQ Device SCC-AO10 3 AO (X ) AO GND 2 1 Load I Figure 1. SCC-AO10 Connected to a Nonreferenced Load E/M Series DAQ Device SCC-AO10 3 AO (X ) AO GND 2 1 Load I Figure 2. SCC-AO10 Connected to a Load with a High Common-Mode Voltage Connecting Two SCC-AO10 Modules in Series You can increase the maximum total output voltage to ±20 V by connecting two SCC-AO10 modules in series. Plug the two modules into sockets J17 and J18 of the SC-2345/2350, and wire the modules to a load as shown in Figure 3. SCC-AO10 Isolated Analog Output Module User Guide 4 ni.com

E/M Series DAQ Device SCC-AO10 in Socket J18 3 AO 1 AO GND 2 + V OUT2 + 1 I SCC-AO10 in Socket J17 V OutTotal 3 AO 0 AO GND 2 + V OUT1 Load 1 I Figure 3. Connecting Two SCC-AO10 Modules in Series The SC-2345/2350 routes the E/M Series DAQ device analog output channels AO 0 and AO 1 to the SCC-AO10 modules, and the resulting maximum output voltage range is ±20 V. Refer to Figure 3 and use the following formula to calculate the total output voltage from both SCC-AO10 modules: V OutTotal = V OUT1 + V OUT2 where V OutTotal is the total output voltage from both SCC-AO10 modules V OUT1 is the voltage across terminals 1 and 3 of the SCC-AO10 module in socket J17 V OUT2 is the voltage across terminals 1 and 3 of the SCC-AO10 module in socket J18 For information about how to configure the SCC-AO10 module with NI-DAQmx, refer to the SCC Quick Start Guide. National Instruments Corporation 5 SCC-AO10 Isolated Analog Output Module User Guide

Using the SCC-AO10 Scaling Voltage Measurements Isolated Ground Reference This section contains information regarding scaling voltage measurements and isolated ground references. The SCC-AO10 is a ±10 V isolated analog output module. The output voltage is controlled by an E/M Series DAQ device AO output channel, AO (X). The relationship between the AO (X) voltage level and the output voltage level of the SCC-AO10 is a one-to-one linear relationship. That is, where V AO(X) is the AO 0 voltage level V AO10 is the SCC-AO10 voltage output in volts Each SCC-AO10 module is referenced to its own isolated ground. Each isolated ground can have up to 60 VDC of common-mode voltage between itself and any other channel ground or chassis ground. Refer to the Connecting the SCC-AO10 to a Load section for ways to use the isolated ground in signal connections. Calibrating Gain and Offset Errors V AO( X) = V AO10 The SCC-AO10 is calibrated at the factory before shipment. To adjust the gain and offset of the SCC-AO10 in your system using an E/M Series DAQ device, you need a voltage meter and a 1/8 in. flathead screwdriver. Before adjusting the SCC-AO10, allow 30 minutes for the DAQ device to warm up to its nominal operating temperature. To adjust the gain and offset of the SCC-AO10, complete the following steps: 1. Disconnect the load from the SCC-AO10 you want to calibrate. 2. Set an output range of 10 to +10 V for AO (X), the E/M Series DAQ device channel connected to the SCC-AO10. 3. Connect the negative lead of the voltmeter to the isolated ground terminal (pin 1) and the positive lead to the voltage output terminal (pin 2 or 3) of the SCC-AO10. 4. Using your software, set AO (X) to output 0 VDC. SCC-AO10 Isolated Analog Output Module User Guide 6 ni.com

5. Adjust the offset potentiometer on the top of the SCC-AO10 until the voltmeter reads 0 VDC ±100 μv. The offset is now calibrated. 6. Using your software, have AO (X) output 9.9 VDC. Adjust the gain potentiometer on the top of the SCC-AO10 until the voltmeter reads 9.9 VDC. The gain is now calibrated. Specifications These ratings are typical at 25 C unless otherwise stated. Electrical Number of output channels... One nonreferenced (floating) Input range... ±10 V Output range... ±10 V Current drive... ±30 ma Gain nonlinearity... 0.5% of full-scale output range Output noise... 2.5 mv rms typ; 4 mv rms max Bandwidth... >23 khz Slew rate... 1 V/μs Short circuit protection Current... 37 ma max Duration... Unlimited Load impedance... 10,000 pf max National Instruments Corporation 7 SCC-AO10 Isolated Analog Output Module User Guide

Power Requirement Physical Analog power...180 mw max at full load 172 mw max with no load +15 V...6 ma max at full load 5.73 ma max with no load 15 V...6 ma max at full load 5.73 ma max with no load Digital power (+5 V)...1.15 W max at full load 600 mw max with no load +5 V...230 ma max 120 ma max with no load 1.87 cm (0.74 in.) 7.93 cm (3.12 in.) 3.55 cm (1.4 in.) Figure 4. SCC-AO10 Dimensions Weight...28 g (1.0 oz) I/O connectors...one 20-pin right-angle male connector; one 3-pin screw terminal Field-wiring diameter...28 to 16 AWG SCC-AO10 Isolated Analog Output Module User Guide 8 ni.com

Maximum Working Voltage (Signal + common-mode) each input should remain within 42.4 V peak or 60 VDC of ground. Maximum working voltage refers to the signal voltage plus the CMV. Channel-to-earth (inputs)... 42.4 V peak or 60 VDC, Measurement Category I Caution This device is rated for Measurement Category I and is intended to carry signal voltages no greater than 42.4 V peak or 60 VDC. Do not use this device for connection to signals or for measurements within Categories II, III, or IV. Isolation Voltage Environmental Channel-to-earth isolation Continuous... 60 VDC, Measurement Category I Withstand... 2300 V rms verified by a 5 s dielectric withstand type test Operating temperature... 0 to 50 C Storage temperature... 20 to 70 C Humidity... 10 to 90% RH, noncondensing Maximum altitude... 2,000 m Pollution Degree (indoor use only)... 2 Stability Recommended warm-up time... 10 min (30 min for connected E/M Series DAQ device) Output offset drift... 300 μv/ C Gain temperature coefficient... 300 ppm/ C National Instruments Corporation 9 SCC-AO10 Isolated Analog Output Module User Guide

Safety This product meets the requirements of the following standards of safety for electrical equipment for measurement, control, and laboratory use: IEC 61010-1, EN 61010-1 UL 61010-1, CSA 61010-1 Note For UL and other safety certifications, refer to the product label or the Online Product Certification section. Electromagnetic Compatibility This product meets the requirements of the following EMC standards for electrical equipment for measurement, control, and laboratory use: EN 61326 (IEC 61326): Class A emissions; Basic immunity EN 55011 (CISPR 11): Group 1, Class A emissions AS/NZS CISPR 11: Group 1, Class A emissions FCC 47 CFR Part 15B: Class A emissions ICES-001: Class A emissions Note For the standards applied to assess the EMC of this product, refer to the Online Product Certification section. Note Note For EMC compliance, operate this product according to the documentation. For EMC compliance, operate this device with shielded cables. CE Compliance This product meets the essential requirements of applicable European Directives as follows: 2006/95/EC; Low-Voltage Directive (safety) 2004/108/EC; Electromagnetic Compatibility Directive (EMC) Online Product Certification Refer to the product Declaration of Conformity (DoC) for additional regulatory compliance information. To obtain product certifications and the DoC for this product, visit ni.com/certification, search by model number or product line, and click the appropriate link in the Certification column. SCC-AO10 Isolated Analog Output Module User Guide 10 ni.com

Environmental Management NI is committed to designing and manufacturing products in an environmentally responsible manner. NI recognizes that eliminating certain hazardous substances from our products is beneficial to the environment and to NI customers. For additional environmental information, refer to the NI and the Environment Web page at ni.com/environment. This page contains the environmental regulations and directives with which NI complies, as well as other environmental information not included in this document. Waste Electrical and Electronic Equipment (WEEE) EU Customers At the end of the life cycle, all products must be sent to a WEEE recycling center. For more information about WEEE recycling centers and National Instruments WEEE initiatives, visit ni.com/environment/weee. RoHS National Instruments (RoHS) National Instruments RoHS ni.com/environment/rohs_china (For information about China RoHS compliance, go to ni.com/environment/rohs_china.) SCC-AO10 Connector Pin Assignments Figure 5 shows the I/O connector pins on the bottom of the SCC-AO10. 4 1 2 5 3 1 Pin 1 2 Pin 2 3 PWB Key 4 Pin 19 5 Pin 20 Figure 5. SCC Module Bottom View National Instruments Corporation 11 SCC-AO10 Isolated Analog Output Module User Guide

Table 1 lists the signal connection corresponding to each pin. Table 1. SCC-AO10 I/O Connector Signal Assignments Pin Number Signal 1 E/M Series AO (X) 2 E/M Series AO GND 3 4 E/M Series AO GND 5 6 7 8 9 +5 V 10 GND 11 12 + 5 V reference 13 +15 V 14 15 V 15 16 17 18 19 20 National Instruments, NI, ni.com, and LabVIEW are trademarks of National Instruments Corporation. Refer to the Terms of Use section on ni.com/legal for more information about National Instruments trademarks. Other product and company names mentioned herein are trademarks or trade names of their respective companies. For patents covering National Instruments products/technology, refer to the appropriate location: Help»Patents in your software, the patents.txt file on your media, or the National Instruments Patent Notice at ni.com/patents. 2002 2008 National Instruments Corporation. All rights reserved. 371080D-01 Aug08