Safety Control. FS1A Multi-function Safety Relay. Optional Parts. Connecting Tool. Marked Cable Tie. DIN Rail BNDN1000 Aluminum, 1m 35mm wide

Safety Control. FS1A Multi-function Safety Relay. Optional Parts. Marked Cable Tie. DIN Rail BNDN1000 Aluminum, 1m 35mm wide

Part Number Total I/O Power Voltage Input Voltage Output Type Maximum Digital I/O Maximum Analog I/O V AC Relay 24V DC.

Power Supplies. PS5R Standard Series Switching Power Supplies. Part Numbers. Part Number

Programmable Logic Controllers

RE17LAMW on-delay timing relay - 1 s..100 h V AC/ DC - solid state output

Page Housing Plastic Metal Mounting DIN Rail or surface mount Panel or bracket mount Wattage Range 10W to 240W 7.5W to 240W 10W to 300W

OTB1E0DM9LP I/O distributed module OTB - Ethernet TCP/IP m

OTB1C0DM9LP I/O distributed module OTB - CANopen bus m

RE17LAMW on-delay timing relay - 1 s..100 h V AC/DC - solid state output

PS5R Series Switching Power Supplies. The PS5R offers a sleek, compact, ergonomic design, worldwide approvals, and broad range of output capacities.

MicroSmart Pentra. Overview

OTB1C0DM9LP I/O distributed module OTB - CANopen bus m

RE17LCBM off-delay timing relay - control - 1 s..100 h V - solid state output

RE22R1QMQ star-delta timing relay - 230VAC/440VAC - 1 C/O

ABL1REM24100 regulated SMPS - single phase V input - 24 V output W

ABL1REM24025 regulated SMPS - single phase V input - 24 V output - 60 W

RE9RA21MW7 off-delay timing relay s V AC -

The Slim type and the 24 I/O All-in-one CPU can be expanded with the many choices of expansion

OTB1E0DM9LP I/O distributed module OTB - Ethernet TCP/IP m

OTB1C0DM9LP. Main , length of segment <= 185 m , length of segment <= 160 m. 3.4 kohm for I8...I kohm I0...I1 5.7 kohm I6...

Functional configuration Rated input voltage Power ratings Output voltage Output current Part number Non-PFC

RM22TG. Product data sheet Characteristics. three-phase control relay Vac, 2 C/O. Main. Complementary. Network number of phases

Energy Management Modular DC Energy analyzer Type VMU-E and VMU-X

DC562, digital input/output module,

DC561, digital input/output module,

Intrinsically Safe Explosion Proof Barriers

ABL8REM24050 regulated SMPS - 1 or 2-phase V AC - 24 V - 5 A

Relays & Sockets. RSC Series. RSC Series Solid State Relays. Part Number Selection Specifications

ABL1RPM24100 regulated SMPS - single phase V input - 24 V output W

DX561 Digital Input/Output Module

DC541 Digital Input/Output Module

RM17UAS. Product datasheet Characteristics. voltage control relay RM17-U - range V DC. Main. Complementary. Price* : 70.

OTB1S0DM9LP I/O distributed module OTB - Modbus non isolated serial link m

RE22R2AMR On-delay Timing Relay s 300h V AC/DC - 2C/O

Model Number Structure

RE22R2KMR Off-delay Timing Relay s 10min V AC/DC - 2C/O

ABL8REM24050 regulated SMPS - 1 or 2-phase V AC - 24 V - 5 A

G3PC. Model Number Structure. Solid State Relays with Failure Detection Function. Model Number Legend

RM35JA32MR Current control relay 0.15A 15A, 2 C/O

XPSMCMCO0000EM Modbus TCPIP diagnostic expansion module with screw term

ATV12HU22M3 variable speed drive ATV12-2.2kW - 3hp V - 3ph - with heat sink

RM35UB3. Product data sheet Characteristics. voltage control relay RM35-U - range V AC. Main. Complementary

DI561 Digital Input Module

TU531, TU532 Terminal Unit

ATV12P075M3 variable speed drive ATV kW - 1hp V - 3ph - on base plate

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

Output Voltage* (nom.)(adjustable)

RE22R2CMR Off-delay Timing Relay s 300h V AC/DC - 2C/O

KEPCO GIVES YOU ZERO-UP PROGRAMMABILITY IN AN AFFORDABLE POWER MODULE

RE22R2QGMR Star-Delta Timing Relay s 300h V AC/DC - 2C/O

Contact protection relay

RE8TA31BU industrial timing relay s - type A - 24 V AC/DC, V AC - 1 C/O

RM17UB3. Product data sheet Characteristics. voltage control relay RM17-U - range V AC. Main. Complementary

RM4JA01F current measurement relay RM4-J - range ma V AC

TM241C40U controller M IO transistor NPN

PCD3.C90. Date Modification Asked by: Version E/A Bus Connector PCD2.K106 change to PCD3.K106 Müller.R 1.1

AI561 Analog Input Module

OTB1E0DM9LP I/O distributed module OTB - Ethernet TCP/IP m

DC522 Digital Input/Output Module

TM241C24T controller M IO transistor PNP

ABL8RPS24100 regulated SMPS - 1 or 2-phase V - 24 V - 10 A

FEATURES DESCRIPTION FEATURES

RE8YG31BUTQ industrial timing relay s - type Qc - 24 V AC/DC, V AC - 1C/O

AO523 Analog Input Module

ATV12P037F1 variable speed drive ATV kW hp V - 1ph - on base plate

ABS2EC01EB input interface module mm - solid state - 24 V DC

TM3AI4 module TM3-4 analog inputs

MINI-PS AC/10-15DC/8

ABL8WPS24400 regulated SMPS - 3-phase V - 24 V - 40 A

Micro PLCs MicroSmart

Voltage Current Front-mounting bracket

TM221M16TG controller M IO transistor PNP spring

Output Voltage* (nom.)(adjustable)

TM3TM3 module TM3-2 temperature inputs and 1 analog output

ABL8REM24030 regulated SMPS - 1 or 2-phase V AC - 24 V - 3 A

XPSMCMDO Digital output pairs expansion modules with screw term

RM4JA32MW current measurement relay RM4-J - range A V AC DC

ATV12H018M2 variable speed drive ATV kW hp V - 1ph

RE22R1QMQ star-delta timing relay - 230VAC/440VAC - 1 C/ O

TM5C12D6T6L compact I/O expansion block TM5-24 I/0-12 DI - 6 DO transistor - 4 AI - 2 AO

RE7YA12BU time delay relay for star-delta starter s - 24 V AC DC - 2OC

DC532-XC, digital input/output module,

RM35TF V AC

ABL1REM Main. Rated power in W. Power supply output current V. <= 100 Aat 230 V AC. 2.5 Aat 240 V

Part No. Description Product Life Cycle Phase *) unit, 24 VDC, spring terminals. unit, 24 VDC, spring terminals, XC version

DI572 Digital Input Module

ABL4RSM24050 regulated SMPS - 1 or 2 phase V AC - 24 V - 5A

CI542 PROFIBUS Communication Interface Module

Energy Management Modular DC Energy analyzer Type VIM-E and VIM-X

XPSMF40. Main. Safety module name. Monitoring safety detection discrete input Monitoring safety dialogue discrete output

AI531 Analog Input Module

ABL8MEM12020 regulated SMPS - 1 or 2-phase V AC - 12 V - 2 A

RM4UA33M voltage measurement relay RM4-U - range V V AC

TRIO-DIODE/12-24DC/2X10/1X20

ATV12H075M3 variable speed drive ATV kW - 1hp V - 3ph - with heat sink

RE8YG31BUTQ industrial timing relay s - type Qc - 24 V AC/DC, V AC - 1C/O

OTB1S0DM9LP I/O distributed module OTB - Modbus non isolated serial link m

Energy Management BUS Adapter Type VMU-B

Transcription:

is a type of field bus that is primarily intended to be used to control sensors and actuators. is a network system that is compatible with the IEC62026 standard. A master device can communicate with slave devices such as sensors, actuators, and remote I/Os, using digital and analog signals transmitted over this bus. The system is comprised of the following three major components: One master (icrosmart master module - FC4A-AS62) One or more slave devices (sensors, actuators or remote I/Os) Dedicated 30V DC power supply (PS2R series power supply) These components are connected using a two-core cable for both data transmission and power supply. employes a simple yet efficient wiring system and features automatic slave address assignment function, while installation and maintenance are also very easy. odules icrosmart IDEC SmartRelay aster odule PS2R Power Supply Part Numbers Description Part Number Page icrosmart aster odule FC4A-AS62-7 Communication odule for IDEC SmartRelay FL1B-CAS2-9 Power Supply 73W 145W PS2R-Q30ABL PS2R-F30ABL -6 www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada (888) 317-IDEC -11

icrosmart aster odule Capable of Connecting 62 Slaves using a Two-wire Cable Compliance with Ver. 2.1 specifications Digital and analog slaves can be connected. Housing width 23.5 mm, the same profile as other icrosmart modules. Configuration and slave monitoring can be done using the LED indicators and pushbuttons on the font panel as well as using WindLDR Ver. 4.21 or higher. The master profile is compliant with the entire specifications of 1e. The master module can be used with 20-I/O relay output slim type CPU modules (FC4A-D20RK1 and FC4A-D20RS1) and 40-I/O slim type CPU modules (FC4A-D40K3 and FC4A-D40S3). The CPU module can control a maximum of 634 I/O points: digital I/O points 200 plus slave I/O points 434. When an master module is mounted, only five more I/O modules can be added to the icrosmart PLC system. aster odule Part Number Programming & onitoring Software Part Number Part Number icrosmart AS- Interface aster odule FC4A-AS62 WindLDR (Ver. 4.21 or higher) WINDLDR CPU odules compatible with aster odule Power Input Type Output Voltage High-speed Transistor Output I/O Points Part Number Package Quantity Slim Type Sink 0.3A FC4A-D20RK1 Relay 2A 240V AC/2A 30V DC/2A 20 points (12 in/ 8 out) Slim Type Source 0.3A FC4A-D20RS1 24V DC 24V DC Sink/source Slim Type Transistor sink output 0.3A 40 points (24 in/ 16 out) FC4A-D40K3 Slim Type Transistor source output 0.3A FC4A-D40S3 *Two points are transistor outputs, and six points are relay outputs. www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada (888) 317-IDEC -7 1

icrosmart aster odule & Dimensions General Operating Temperature 0 to 55 C (no freezing) Storage Temperature 25 to +70 C (no freezing) Relative Humidity Level RH1, 30 to 90% (non-condensing) Pollution Degree 2 (IEC 60664) Corrosion Immunity Atmosphere free from corrosive gases Altitude Operation:0 to 2000m Transport:0 to 3000m When mounted on a DIN rail: 10 to 57 Hz amplitude 0.075 mm, 57 to 150 Hz acceleration 9.8 m/s 2 Vibration Resistance 2 hours per axis on each of three mutually perpendicular axes When mounted on a panel surface: 2 to 25 Hz amplitude 1.6 mm, 25 to 100 Hz acceleration 39.2 m/s 2 90 minutes per axis on each of three mutually perpendicular axes Shock Resistance 147 m/s 2, 11 ms duration, 3 shocks on each of three mutually perpendicular axes (IEC 61131) Function External Power Supply Current Draw Effect of Improper Input Connection Connector on other Board Internal Current Draw aster odule Power Consumption Weight (approx.) PS2R Series power supply, 29.5 to 31.6V DC 65 ma (normal operation) 110 ma maximum No damage STB2.5/3-GF-5.08BK (Phoenix Contact) Insertion/removal durability: 100 times minimum 80 ma (5V DC) 540 mw (24V DC) 85g Communication aximum Bus Cycle aximum Slaves aximum I/O Points Cable aximum Length Rated Bus Voltage When 1 through 19 slaves are connected:3 ms When 20 through 62 slaves are connected:0.156 (1 + N) ms where N is the number of active slaves 5 ms maximum when 31 slaves are connected 10 ms maximum when 62 slaves are connected Standard slaves:31 A/B slaves:62 Standard slaves:248 total (124 inputs + 124 outputs) A/B slaves:434 total (248 inputs + 186 outputs) When using no repeater or extender:100m When using a total of 2 repeaters or extenders:300m 30V DC Dimensions (in mm) FC4A-AS62-8 www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada (888) 317-IDEC

IDEC SmartRelay Communication odule Communication modules provide optimum solutions for decentralized control. The module enables four data bits to be transferred from the IDEC SmartRelay base module to the and vice versa. I/O points: 4 input points and 4 output points Acts as an interface between and IDEC SmartRelay Allows IDEC SmartRelay to be used as a slave on an Network Communication odule Part Number Part Number Communication odule for IDEC SmartRelay FL1B-CAS2 Communication odule & Dimensions Operating Temperature 0 to 55 C Storage Temperature 40 to +70 C Relative Humidity 10 to 85% (no condensation) Rated Voltage 30 VDC (26.5VDC to 31.6VDC) Reverse Polarity Protection Yes Current Draw 70 ma max. EC Electrostatic Discharge Electromagnetic field First Transient Burst Pulse Radiated Emission 8 kv air discharge (IEC61000-4-2) 4 kv contact discharge Field strength 10V/m (IEC61000-4-3) 1kV (criteria A) (IEC61000-4-4) 1kV (criteria B) Class A (EN55011) Vibration Resistance 5 to 9 Hz, amplitude 3.5 mm 9 to 150 Hz, 9.8 m/s 2 Shock Resistance 147 m/s 2 11ms (X, Y, Z each direction 3 times) Slave type Standard slave I/O code 7 Profile I/D code F I/D2 code F Degree of Protection IP20 Terminal Style Screw terminal (tightening torque: max. 0.5Nm) Applicable wire 0.5 to 1.5mm 2 Installation Dimensions Weight on a 35mm mounting rail according to DIN EN50022/wall mounting 36W 90H 58D mm 75g www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada (888) 317-IDEC -9 58 53 Dimensions 90 L+ 24VAC/DC FL1B-CAS2 35.5 RUN/STOP Service A B LON X2 3 4

Communication odule Logic Assignments IDEC SmartRelay System Inputs: Output data bits: In D0 I n+1 D1 I n+2 D2 I n+3 D3 Outputs: Input data bits: Q m D0 Q m+1 D1 Q m+ 2 D2 Q m+3 D3 n,m depends on the plug-in position communication module relative to the IDEC SmartRelay CPU. It indicates the number of the input or output in the IDEC SmartRelay program code. Communication odule Application Examples -10 www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada (888) 317-IDEC

PS2R Power Supply Power Supply with Universal AC Input Voltage Input voltage range: 100 to 240V AC Two output ratings: 73W and 145W Slim housing style mountable on DIN rails IP20 finger-safe terminals CE marked (LVD, ECD) UL listed (UL 508), CSA (No. 950), TÜV (EN 60950) Noise standards EN 55022, EN 61000-6-2 compliant I/O terminals are separated to top and bottom for easy wiring. With input indicator (orange) and output indicator (green) ountable on 35-mm-wide DIN rail Power Supply Part Numbers Output Capacity Input Voltage Output Voltage Part Number Power Supply 73W PS2R-Q30ABL 100 to 240V AC 30.5V DC Power Supply 145W PS2R-F30ABL PS2R Power Supply General Part Number PS2R-Q30ABL PS2R-F30ABL Input Output Supplementary Functions Efficiency Voltage Frequency 83% (typical) at the rated input/output 100 to 240V AC (85 to 264V AC) 47 to 63 Hz Current 100V AC 1.8A (typical) at the rated load 3.0A (typical) at the rated load 220V AC 1.0A (typical) at the rated load 2.0A (typical) at the rated load Leakage Current 3.5 ma maximum (UL, CSA, VDE) Inrush Current 30A maximum (Ta 25 C at cold start) Rated Voltage 30.5V DC Rated Current 2.4A 4.8A Adjustable Voltage Range Fixed Ripple Noise Voltage 300 mv p-p maximum (0 to 10 khz), 50 mv p-p maximum (10 to 500 khz) according to standard Input/Load Fluctuation 3% Overall Fluctuation 29.5 to 31.6V DC including input fluctuation, output fluctuation, temperature fluctuation, ripple voltage Delay Time 2 sec maximum (delay in output voltage change from 5V to 26.5V) according to standard Startup Time 1 sec maximum (output voltage change from 21.5V to 29.5V) according to standard Output Holding Time 10 ms minimum according to standard Overcurrent Protection 110% (typical), automatic reset (Note 1) Overvoltage Protection 120% minimum (Note 2) Undervoltage Protection 95% maximum, automatic reset Input Indicator Orange Output Indicator Green Dielectric Strength Between inputs and outputs:3.0 kv AC, 1 minute Between inputs and ground:3.0 kv AC, 1 minute Between outputs and ground:0.5 kv AC, 1 minute Insulation Resistance Between inputs and outputs:100 Ω minimum (500V DC megger) Between inputs and ground:100 Ω minimum (500V DC megger) Operating Temperature 0 to 60 C (See the derating curve.) Vertical mounting only Storage Temperature 25 to +70 C (no freezing, non-condensation) Operating Humidity 95% RH (non-condensation) Vibration Resistance 10 to 57 Hz amplitude 0.075 mm, 57 to 150 Hz acceleration 10 m/s 2 10 cycles per axis on each of three mutually perpendicular axes (EN 61131-2) www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada (888) 317-IDEC -11

PS2R Power Supply con t Part Number PS2R-Q30ABL PS2R-F30ABL Vibration Resistance 10 to 57 Hz amplitude 0.075 mm, 57 to 150 Hz acceleration 10 m/s 2 10 cycles per axis on each of three mutually perpendicular axes (EN 61131-2) Shock Resistance 147 m/s 2, 11 ms duration, 2 shocks per axis, on six mutually perpendicular axes (EN 61131-2) Terminal IP20 Weight (approx.) 800g 1300g Dimensions 120H 54W 120D mm 120H 81W 120D mm Safety Standards EC Standard (EI) Radiated Emission Conducted Emission UL 508 listed CSA C22.2 No. 950 EN 60950, EN 61010, EN 61131-2 EN 50295 IEC 61000-6-2 EN 55022 class B EN 55022 class B 1. The power supply is provided with an overvoltage protection circuit, but a long period of overload and short-circuit should be avoided. 2. After turning off the input voltage, wait at least 10 seconds before turning on again. PS2R Power Supply Drawings & Dimensions Block Diagram Output Derating Terminal Names PS2R-Q30ABL PS2R-F30ABL Output Power (%) Operating Temperature ( C) Dimensions PS2R-Q30ABL ounting Direction: Vertical only All dimensions in mm PS2R-F30ABL ➀ (L) AC input terminal ➁ (N) AC input terminal (ground side) ➂ () Ground terminal (protective ground) ➃ (+) + output terminal ➄ ( ) output terminal ➅ () Ground terminal (output side) ➆ (AC) Input indicator (goes on when input is on) ➇ () Output indicator (goes on when output is on) -12 www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada (888) 317-IDEC