RXTP ROOM TEMPERATURE

Similar documents
RST ROOM TEMPERATURE TRANSMITTER. Mounting and operating instructions

RXTH DUAL ROOM SENSOR / SWITCH

RTT2 ROOM TEMPERATURE SWITCH. Mounting and operating instructions

RТTH DUAL ROOM SWITCH

DXTH DUCT SENSOR / SWITCH FOR TEMPERATURE AND HUMIDITY. Mounting and operating instructions

MVS RAIL ELECTRONIC FAN SPEED CONTROLLER. Mounting and operating instructions

CNVT-USB-RS485 MODBUS TO USB CONVERTER. Operating instructions

DSTHM-2 COMBINED T AND RH DUCT TRANSMITTER. Mounting and operating instructions

HPS-M -2 DIFFERENTIAL PRESSURE TRANSMITTER. Mounting and operating instructions

DPOM8-24/20 DIN RAIL POWER OVER MODBUS MODULE. Mounting and operating instructions

STR-3 STANDARD 3-PHASE 230 VAC TRANSFORMER CONTROLLER. Mounting and operating instructions

Operating instructions. Speed monitor D / / 2014

Communicative controller for VAV systems

UC102 basic version with display and knob UC102BL version with display, knob and backlight UC102DK version without knob and display

RTD-W Installation Instructions

Room Temperature Controller

Output Signal Active Note DC V. Electrical Data Power Supply DC V, ±10%, 1.4 W

Priva Blue ID Analogue output module with manual override AO2m/AO4m

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

Operating instructions. Switching amplifier DN0210 DN / / 2015

LLR-MOD Modbus Light Level and Occupancy Sensor

See instructions to download and install the latest version of LinkBoxEIB and the user's manual at

Voltage Transducer UMT516 / MT516

MU110-6U. Analog output module 6 channel. User guide

MXIO. Compact I/O module. Summary. Application Compact I/O module for data acquisition and HVAC control systems. Function

Installation manual CF8-W-Disp-AL

Procon A1M. INSTALLATION MANUAL Version MITSUBISHI ELECTRIC FOR INSTALLERS

Room unit with PPS2 interface

Priva Blue ID Digital input module DI4/DI8/DI16

MC 11 EB-2 Power supply cabinet with external bus, AC version

MOD-RI Room Interface Modules with Modbus

RTD-RA. realtime. Installation Instructions. English A B. Installation Instructions Control Systems LEDS ALL DIMENSIONS IN MM

Priva Blue ID Relay output module DOR4/DOR8

ADC7520 SERIES. 1600W Battery Chargers and Power Supplies

RCF-230CAD. Room controller with communication for fancoil applications with two analogue V DC outputs

RCF-230CAD. Communicating room controller for fan-coil applications with two analogue V DC outputs

Small distributed I/O module

RCF-230CD. Communicating room thermostat for fan-coil applications with on/off outputs

DOR6. Components All functions and indications are on the front of the module. Characteristics

Blue ID Power injection module PI60

Priva Blue ID Communication module RS485 SC44

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

TEMPERATURE AND HUMIDITY TRANSDUCER P18 TYPE USER S MANUAL

Switched Mode Power Supply Operating manual PAP800

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

Instruction Manual. T3110 T3110L T3110Ex

OZONE SWITCH Model OS-6. OS-6 Features

POE084824B. PoE 54V/8x0,3A/4x7Ah PoE buffer power supply for up to 8 IP camera. v.1.1 EN* Edition: 7 from

RTD-NET Installation Instructions

1 IF-810 or IF-811 Terminal (Slave) 2 Intended Use. 3 Assembly and Installation _V IF-810/IF-811

DP2500 DP0250. Differential Pressure Transmitter. Product Bulletin

Carbon Monoxide Sensor - ModBus

Temperature and humidity module DHT11 Product Manual

USER MANUAL VIBRATION CONTROL RMA-POWER-BOX 107/230

Blue ID Communication module RS485 SC44

Room Temperature Controller

CMSA-100 Manual. Cinema Media Server Automation

Non-communicating room controllers

Multifunction Transducer MT440

VC3000 Series Line Voltage Switching Relay Pack Controllers Installation Guide

english S-5EC Potentiometer 5-step Operating Instructions Keep for reference! L-BAL-E265-GB 1608 Index 002

InBin-P Pressure switches from 5 Pa Pa

Technical data. Safety notes. Product features

Warranty. Warning. Copyright. Contact Us

INSTALLATION DKM-409 NETWORK ANALYSER WITH HARMONIC MEASUREMENT AND SCOPEMETER. Before installation:

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

Electrical Actuators

See instructions to download and install the latest version of LinkBoxEIB and the user's manual at

1 IF-812 or IF-815 Terminal (Slave) 2 Intended Use. 3 Assembly and Installation _V IF-812/IF-815

Duct humidity and temperature sensor for all HVAC duct applications. Designed for control and monitoring applications.

See instructions to download and install the latest version of LinkBoxEIB and the user's manual at

CDR-RH Room CO 2, Temperature and Humidity Sensors (Controllers)

thanos RS485 Modbus Application Functions Multifunction Room Operating Unit Datasheet

MiG2 CONTROLLERS. 2 & 4 Stage General Purpose Controllers, with Air-conditioning Facilities

Priva Blue ID Communication module RS232 SC22

Buffered Power Supply PS-30DR v1.0

Output Signal. 22DTM-16 BACnet DC V, DC V. Electrical data Power Supply DC V, ±10%, 0.3 W

Features: S98-B v1.0 S98-B 9-port switch with buffer power supply for 8 IP cameras

See instructions to download and install the latest version of LinkBoxLON and the user's manual at

Product and functional description

sensor, which compensates for ageing effects, is highly insensitive to pollution and offers outstanding long term stability.

Electrical Actuators

9.5 nominal torque 4.5 W 16 VA. Min. 30 nominal voltage Min. 30 Nm. Reversible with switch By mounting. MIN (minimum position)

INSTALLATION MANUAL. LC 200 Electronic Overload Guard. Software versione PW0501 R 0.3

Room controller STRA-17

USER S GUIDE. EE210 - Humidity and Temperature Transmitter for demanding Climate Control Applications GENERAL

Installation, Operation and Maintenance Manual

TER-MOD Active Room Temperature Sensors (Controllers) with Modbus

Ultra Slim Relays 24

Dip Switch settings.

MM-A20 BMS Interface for Mitsubishi Electric Split Air-Conditioning

Output Signal. Temperature 22DTH-56M BACnet DC V, DC V. Electrical Data Power Supply DC V, ±10%, 0.7 W

IF-80x Outdoor Terminal

LED PANEL. User Manual Please read the instructions carefully before use LED-7TC. Innovation, Quality, Performance 15-

PSBOC PSBOC 27,6V/5,5A/OC

SDM-6RO. Expansion Module 6 relay outputs. Manufactured for

IMIO100 IMIO105. DDC controllers. Summary

Priva Blue ID C-Line Mix input/output module MX34


Transcription:

ROOM TEMPERATURE CONTROLLER WITH PI CONTROL Mounting and operating instructions

Table of contents SAFETY AND PRECAUTIONS 3 PRODUCT DESCRIPTION 4 ARTICLE CODES 4 INTENDED AREA OF USE 4 TECHNICAL DATA 4 STANDARDS 4 OPERATIONAL DIAGRAMS 5 WIRING AND CONNECTIONS 5 MOUNTING & OPERATING INSTRUCTIONS IN STEPS 5 MODBUS REGISTER MAPS 8 VERIFICATION OF INSTALLATION INSTRUCTIONS 9 TRANSPORT AND STOCK KEEPING INFORMATION 9 WARRANTY INFORMATION AND RESTRICTIONS 9 MAINTENANCE 9 MIW--EN-001-21 / 02 / 2017 www.sentera.eu 2-9

SAFETY AND PRECAUTIONS Read all information, the datasheet, mounting instructions and wiring scheme before working with the product. For personal and equipment safety, and for optimum product performance, make sure you entirely understand the contents before installing, using, or maintaining this product. For safety and licensing (CE) reasons, unauthorised conversion and / or modifications to the product are not permitted. The product must not be exposed to abnormal conditions, such as: extreme temperatures, direct sunlight or vibrations. Chemical vapours with high concentration in combination with long exposure times can affect the product performance. Make sure the work environment is as dry as possible; check for condensation spots. All installations shall comply with the local health and safety regulations and local electrical codes. This product can only be installed by an engineer or a technician who has an expert knowledge of the product and safety precautions. Avoid contacts with energised electrical parts; always treat the product as if it is life. Always disconnect the power source before connecting the power cables, servicing or repairing the product. Always verify that you apply appropriate power supply to the product and use wires with appropriate size and characteristics. Make sure that all the screws and nuts are well tightened and fuses (if any) are fitted well. Recycling of equipment and packaging should be taken into consideration and disposed in accordance with local and national legislation / regulations. In case there are any questions that are not answered, please contact your technical support or consult a professional. MIW--EN-001-21 / 02 / 2017 www.sentera.eu 3-9

PRODUCT DESCRIPTION The is a room temperature controller with Modbus RTU communication. It regulates a PI controlled analogue output and a relay output, in two modes Heat and Cool. ARTICLE CODES Code Supply Connection G 15 24 VAC ± 10 % 18 34 VDC 3 - wire F 18 34 VDC 4 - wire INTENDED AREA OF USE Monitoring and maintaining temperature and relative humidity in HVAC applications For indoor use only TECHNICAL DATA 1 analogue output: 0 10 VDC / 0 20 ma 1 relay output, C/O (230 VAC / 2 A) Power consumption: no load: max. 25 ma full load: max. 45 ma Load resistance: 0 10 VDC mode > 500 Ω 0 20 ma mode < 500 Ω Selectable temperature ranges: 0 30 C / 10 40 C / 20 50 C / 0 50 C Free selectable temperature range via Modbus: 0 50 C Selectable switching points: by trimmers or via Modbus Selectable temperature hysteresis: 1 / 2 / 3 / 4 / 5 C Autotuning function in Heat mode with three-second light indication (see Fig. 8 Operating indication) Enclosure: rear lid: plastic ABS, black (RAL9004) front cover: ASA, ivory (RAL9010) Protection standard: IP30 (according to EN 60529) Operating ambient conditions: temperature: 0 50 C rel. humidity: < 95 % rh (non-condensing) Storage temperature: -25 50 C STANDARDS Low Voltage Directive 2014/35/EU EMC Directive 2014/30/EC: EN 61000-6-2: 2005/AC:2005, EN 61000-6-3:2007/A1:2011/AC:2012, EN 61326-2-3:2013 WEEE Directive 2012/19/EU RoHs Directive 2011/65/EU MIW--EN-001-21 / 02 / 2017 www.sentera.eu 4-9

OPERATIONAL DIAGRAMS Heat mode Cool mode Relay output 1 Relay output 1 ON (COM NO) ON (COM NO) OFF (COM NC) Setpoint -Hysteresis Setpoint T, [ 0 C] OFF (COM NC) Setpoint Setpoint +Hysteresis T, [ 0 C] T, [ 0 C] T, [%] Setpoint PI control Setpoint PI control t, [s] t, [s] WIRING AND CONNECTIONS Vin Positive DC voltage / AC ~ GND Ground / AC ~ A Modbus RTU (RS485) signal A /B Modbus RTU (RS485) signal /B Ao1 GND NO1 COM1 NC1 Analogue output (0 10 VDC / 0 20 ma) Ground Normally open contact Common contact Normally closed contact Connections Cable cross section: max. 1,5 mm 2 MIW--EN-001-21 / 02 / 2017 www.sentera.eu 5-9

MOUNTING & OPERATING INSTRUCTIONS IN STEPS Before you start mounting the controller, read carefully Safety and Precautions. Choose a smooth surface for an installation location (a wall, panel and etc.). Follow these steps: 1. Open the white cover by releasing the locking plates on both sides of the cover and remove it. (See Fig. 1 Locking plates release.) 2. Insert the cables through the cable opening of the enclosure rear lid. (See Fig. 2 Mounting dimensions.) 3. Fix the unit to the wall / panel taking into account that the unit has to be installed at a minimum height of 1,5 m and the air flow has to pass through it free. Mind the correct mounting position and unit dimensions. See Fig. 2 and Fig. 3. Fig. 1 Locking plates release Fig. 2 Mounting dimension Fig. 3 Mounting position 59,8 Acceptable Not acceptable 2x Ø 6 74,5 20 25,6 9,8 104,5 Keep 1,5 m. minimum distance from the floor 70,5 104,5 4. Do the wiring according to the wiring diagram (see Fig. 4) using the legend information from section Wiring and connections. Fig. 4 Wiring and connections Relay 1 contacts Normally closed Common Normally open Analogue output 0 10 VDC / 0 20 ma Modbus RTU A /B Power supply 15 24 VAC ± 10% / 18 34 VDC MIW--EN-001-21 / 02 / 2017 www.sentera.eu 6-9

5. Check if your unit starts or terminates the network (see Example 1 and Example 2). If it does not, remove the jumper (see Fig. 5). Example 1 Example 2 Fig. 5 Network bus resistor jumper Slave 1 RX ТX Master RX ТX Slave 2 Master Slave n Slave 1 Slave 2 Slave n ATTENTION If an AC power supply is used with any of the units in a Modbus network, the GND terminal should NOT BE CONNECTED to other units on the network or via the CNVT USB-RS485 converter. This may cause permanent damage to the communication semiconductors and / or the computer! 6. Adjust the standalone settings: 6.1 To select the analogue output mode, use jumper JP4. (See Fig. 6 Analogue output selection jumper.) 6.2 To reset the Modbus settings, put and hold jumper P1 for 20 seconds. (See Fig. 7 Modbus reset jumper.) Fig. 6 Analogue output selection jumper Fig. 7 Modbus reset jumper 0 10 VDC 0 20 ma 5 4 3 2 1 Put and hold for 20 seconds 7. Close the enclosure and fix the cover. 8. Switch on the power supply. ATTENTION Do not exceed the maximum power supply rating! Measure before installation! Unregulated 24 VAC supply units provide higher nominal output voltage and activate the integrated fuse protection. ATTENTION If a G-type article is using the same AC power supply source (transformer) as F-type article, a SHORT CIRCUIT may result when the power supply and analogue signal terminals are connected to the same common ground! In this case always connect different article types to separate AC transformers or use the same article version. 9. You can customise the factory settings to the desired ones, through 3SModbus software (if necessary). For the default factory setting see Table Modbus register maps. MIW--EN-001-21 / 02 / 2017 www.sentera.eu 7-9

MODBUS REGISTER MAPS INPUT REGISTERS Data type Description Data Values 1 Temperature signed int. Actual temperature level 0 500 25 25,0 C 2-10 Reserved, returns 0 11 Analogue output value unsigned int. Value of the analogue output 0 1.000 12 Relay status unsigned int. Relay status. When it is On, the contact between COM1 and NO1 is closed. 0 1 1.00 13 Temperature setpoint unsigned int. Temperature setpoint used for PI control 0 500 25 25,0 C 14 Relay setpoint unsigned int. Relay switching setpoint 0 500 25 25,0 C 0 % 100 % Off On 15 Hysteresis unsigned int. Hysteresis for the relay switching 1 5 16 Output mode unsigned int. Analogue and relay output mode (Heat / Cool) 0 1 2 = 3 = 4 = 5 = 1,0 C 2,0 C 3,0 C 4,0 C 5,0 C Heat mode Cool mode 17 Kp value unsigned int. Proportional gain value 1 1.000 1 1,0 gain 18 Ti value unsigned int. Integration period value 1 6.000 10 0,1 s 10 s 19-20 Reserved, returns 0 HOLDING REGISTERS Data type Description Data Default Values 1 Device slave address unsigned int. Modbus device address 1 247 1 2 Modbus baud rate unsigned int. Modbus communication baud rate 1 4 2 3 Modbus parity check unsigned int. Parity check mode 0 2 1 4 Device type unsigned int. Device type (Read only) X = 1023 5 HW version unsigned int. Hardware version of the device (Read only) XXXX 0 x 011 HW version 1.1 6 FW version unsigned int. Firmware version of the device (Read only) XXXX 0 x 013 FW version 1.3 7 Operating mode unsigned int Reserved, returns 0 8 Output overwrite unsigned int. Enables the direct control over the outputs. 0 1 0 9-10 Reserved, returns 0 11 Temperature setpoint unsigned int. Temperature setpoint used for PI control 0 500 250 50 50,0 C 12 Relay setpoint unsigned int. Relay switching setpoint 0 500 250 50 50,0 C 13 Hysteresis unsigned int. Hysteresis for the relay switching 1 5 4 14 Kp value unsigned int. Proportional gain value 0 1.000 50 1 1,0 gain 15 Ti value unsigned int. Integration period value 1 6.000 100 16 Output mode unsigned int. Selects the analogue and relay output mode (Heat / Cool) 0 1 0 17-19 Reserved, returns 0 20 Autotune of analogue output unsigned int. Starts autotune in PI control for the analogue output 0 1 If you want to find out more about Modbus over serial line, please visit: http://www.modbus.org/docs/modbus_over_serial_line_v1_02.pdf 2 = 3 = 4 = 2 = 2 = 3 = 4 = 5 = 10 9.600 19.200 38.400 57.600 8N1 8E1 8O1 Disabled Enabled 1 C 2 C 3 C 4 C 5 C 0,1 s 10 s Heat mode Cool mode Autotune start (In progress) Stop (Idle) MIW--EN-001-21 / 02 / 2017 www.sentera.eu 8-9

VERIFICATION OF INSTALLATION INSTRUCTIONS Check the status of the blue ON/OFF LED after you switch on the power supply. (See Fig. 8 Operating indication.) The ON/OFF LED should blink during the initialization period (30 s) at equal intervals of 2 s for 2 s. Then it should give out continuous blue light. If this is not the case, check the connections again. Check if both LEDs (LEDTX and LEDRX) blink after you switch on your unit. (See Fig. 9 Communication detection indication.) If they do, your unit has detected Modbus network. If they blink rapidly: Fig. 8 Operating indication Fig. 9 Communication detection indication ATTENTION The status of both LEDs (LEDTX and LEDRX) can be checked only when the unit is energised. Take the relevant safety measures! TRANSPORT AND STOCK KEEPING INFORMATION Avoid shocks and extreme conditions; stock in original packing. WARRANTY INFORMATION AND RESTRICTIONS MAINTENANCE Two years from the delivery date against defects in manufacturing. Any modifications or alterations to the product after the date of publication relieve the manufacturer of any responsibilities. The manufacturer bears no responsibility for any misprints or mistakes in this data. In normal conditions this product is maintenance-free. If soiled, clean with a dry or dampish cloth. In case of heavy pollution, clean with a non aggressive product. In these circumstances the unit should be disconnected from the supply. Pay attention that no fluids enter the unit. Only reconnect it to the supply when it is completely dry. MIW--EN-001-21 / 02 / 2017 www.sentera.eu 9-9