Product and Application Description

Similar documents
252F 5WG FB_1 DELTA

DELTA i-system wall switch single UP 221/2 5WG AB_2

Push button UP 287, 4 - fold

DELTA profil wall switch, single UP 241/2 5WG AB_2

Product and functional description. Application Program. instabus EIB Technical product information. April (6 x AC 230 V / 0,05 A)

584 5WG AB_1 DELTA

Product and Function Description

Product and Applications Description. Application programs. instabus EIB Technical Product Information. February 2012

Push Button Interface UP 220D31

Product and Application Description

Product and function description

Use of the application program. Contents overview. GAMMA instabus Application program description. August 2012

DELTA i system wall switch single UP 221/2 5WG DB_2. wall switch double UP 222/2, 5WG DB_2. wall switch triple UP 223/2, 5WG DB_2

Product and Applications Description. Example of Operation. Installation Instructions WARNING. Note. Application Programs

Product and functional description

Product and functional description

Product and Applications Description. Application Programs. Example of Operation. Installation Instructions. load circuit AC 230/400V L1 L2 L3 N

Product and Applications Description. Application Programs. Note. instabus EIB Technical Product Information. June 2005

Product and functional description

Weather station AP 257/51

Product and functional description

Weather station GPS AP 257/61 Weather station AP 257/51

Product and functional description

Product and functional description

Product and Applications Description

Product and Applications Description. Note. Example of Operation. Installation Instructions. Application Programs WARNING

Room Temperature Controller

Room Temperature Controllers

Interface AP 146 5WG AB01 for Ethernet-UDP/IP. EIB Device. EIB Device. EIB Device

Switching Actuators N530, 6AX Switching Actuators N532, 10AX Switching Actuators N534, 16/20AX

Room Temperature Controller

OEM. Room unit QAA822 with2- wire interface. Building Technologies CLIMATIX TM. For use with Climatix controllers

Master room unit for RRV controllers

Installation Instructions

Room unit with PPS2 interface

Operating and mounting instructions

Room unit with PPS2 interface

Siemens Spares. RL 513D23 Switching actuator (relay), 3 x 6A. Technical Product Information

QAX50.1 QAX50.5 QAX51.1 QAX51.5. Flexible room unit. Desigo RXC

Room unit with PPS2 interface

Semi flush-mounted room temperature controllers with LCD

Room unit with PPS2 interface

Room sensors QFA4160 QFA41 D AQF4150 AQF3153. Symaro. for relative humidity and temperature with calibration certificates

Technical Datasheet clima RCM-CC

Air Quality Sensor KNX AQS

Semi Flush-mount Room Temperature Controllers with LCD

Weekday / weekend room temperature controller

7-day room temperature controller

Semi flush-mounted room temperature controllers with LCD

KNX T-UP. Temperature Sensor. Technical specifications and installation instructions

7-day room temperature controller

Building Control GAMMA instabus

QMX3.P30 QMX3.P70 QMX3.P02 QMX3.P34 QMX3.P74 QMX3.P37. Wall-mounted sensors and room operator units for KNX PL-Link, KNX S-mode and KNX LTE-Mode

RDF301 RDF CE1N3171en 02 Jun 2010 Building Technologies

UC102 basic version with display and knob UC102BL version with display, knob and backlight UC102DK version without knob and display

Freely configurable flush-mounted room operator unit for KNX PL-Link

Room controller LS 990 / LS plus Stainless Steel / Aluminium

Flush-mount room sensor

Technical Datasheet clima RCM-FC 1. Product description

KNX/EIB Push button sensor 3 Plus F Safety instructions. 2 Device components. 3 Function

1. Function 1. System M multi-function push-button, 4- gang, with room temperature control unit. Table of Contents

Device technology. Supply Bus voltage V DC. Current consumption via bus. Accuracy in the range 300 1,000 ppm 1,000 2,000 ppm 2,000 5,000 ppm

Room thermostat with KNX communications For VAV heating and cooling systems

Room thermostats with KNX communications

Status display unit with P-bus connection

RXB10.1. Room controller. Siemens Building Technologies Building Automation DESIGO RXB. for chilled ceilings and radiators with EIB bus communication

/ 2CKA001473B KNX Technical Reference Manual ABB i-bus KNX. Room temperature controller with display 6108/18-500

EIB/KNX ENO Radio bus interface (32-channel)

Transponder card reader

Room Temperature Controller with 7-Day Time Switch, LCD and opt. Remote Temperature Sensor

Room thermostats with KNX communications

QXA2000 QXA2001. Condensation Monitor QXA2001 QXA2000 AQX2000

DDC110-L1.. DDC110-L4 technolon Room Module

Use of the application program

Weekday / weekend room temperature controller

KNX/EIB Product documentation. Page 1 of 23. Order-No xx Order-No xx Order-No xx Order-No xx

ABB i-bus KNX DALI Light Controller, 8-fold, MDRC DLR/S M, 2CDG110101R0011

Use of the application program

EMO valve drive. 1. Function 1. Table of Contents. 2. Installation

Operating instructions Evaluation system for flow sensors VS / / 2013

DESIGO RX Individual room controllers. for fan-coil systems, chilled ceilings and radiators, with LONMARK-compatible bus communications

KNX USB INTERFACE UIMtp

24-hour room temperature controller

KM692K KELOX BUS room thermostat - Digital

JUMO TYA 201 Single-Phase SCR Power Controller For controlling resistive/inductive loads

Operating Instructions VEGAMET 381

RVL470. Heating controller. G2522en. Installation Instructions. 1 Installation. 2 Commissioning Wall mounting DIN rail mounting

IntesisBox KNX - AIRZONE

Linienkoppler S KNX. Line coupler S KNX. Line coupler S KNX Status: March 16 (Subject to change) Page 1 of 29

Push-buttons 18. Light scenes push-buttons 21. Push-buttons with thermostat 22. Labelling ields 24

Airflow Pressure Sensor

STR-3 STANDARD 3-PHASE 230 VAC TRANSFORMER CONTROLLER. Mounting and operating instructions

Product documentation

Description TR D

Operating instructions. Switching amplifier DN0210 DN / / 2015

VARIA VARIA 826 S WH KNX VARIA 826 S BK KNX D GB F I E NL. Installation and operating instructions Room thermostat VARIA 826 S KNX

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Compact universal controllers

NMID. Remote control. SAPIM I/O number. SAPIM I/O number NBRN (RS485) ZM100. Relay, 24 VDC - + UO07 UI11 UI10 UI09 UI08 UI07 UI06 UI05 UI04 UI03 UI02

Application program: description and examples

Transcription:

Technical Product - Information Product and Application Description The room temperature controller UP 237K and UP 252K are available in the following colors, matching the design of the wall switch design line DELTA i-system or DELTA style: DELTA i-system Temperature Controller UP 237K titanium white 5WG1 237-2KB11 aluminum metallic 5WG1 237-2KB31 DELTA style Temperature Controller titanium white/ metallic silver 5WG1 254-2KB13 platinum metallic 5WG1 254-2KB43 The room temperature controls UP 237K and are especially designed for usage in rooms which are heated and/or cooled and whose temperatures are controlled depending on up to four room operating modes (comfort mode, pre-comfort mode, energy-savings mode and protection mode). As required, a parameter can be used to set that the controller does not consider all four operating modes but rather only three (comfort mode, energy-savings mode and protection mode). The room temperature control can be used a a two-point control (thermostat) or as a continuous control (P or PI control). These Room temperature controller can only function together with the necessary Bus Transceiver Module (BTM) UP 117 and the associated application program. LED displays Along with a button and a rotary knob on its upper edge, the clear and self-explanatory user interface contains 5 green illuminating light emitting diodes (LED) to display whether "manual operation" is activated as well as the current room operating mode and two red illuminating LEDs and 2 duo-color illuminating LEDs on the left edge. The duo-color LEDs are used to display whether the heating valve (LED is lit in red) or the cooling valve (LED is lit in yellow) is open. If these LEDs are not illuminated, then both valves are closed. A red LED is used to display whether a window is open or whether a dew point alarm is pending. Button Briefly pressing the button on the control causes switching in automatic mode (the LED for the display of manual operation is not lit) each time between "comfort mode" and "pre-comfort mode" (with four operating modes) or between "comfort mode" and "energy-savings mode" (with three operating modes). Moreover briefly pressing the button during active energy-savings or protection mode starts a "comfort prolongation". Pressing and holding down (e.g.> 1 s, but < 3 s) the button during continuous comfort prolongation can cause this to end at any time and jump back to the room operating mode before the start of the comfort prolongation. Holding down the button for a longer time (> 3 s) can cause switching from automatic to manual operation. In manual operation every room operating mode can be permanently activated and not changed by a bus telegram. If manual operation is activated, then each time the button is pressed briefly the light display of the current operating mode wanders gradually from the current position to the next operating mode symbol until the extreme right or left position is reached and from there back again. If during a waiting time of around 3 seconds no renewed brief pressing of the button occurs, then the displayed room operating mode will be activated and this reported by the Bus. If the button in "manual operation" is pressed for a very long (> 3 s) time, then the system will be switched to automatic operation and at the same time to comfort mode. If a presence detector is installed, then a brief pressing of the button in automatic operation is ignored. Note: Via a parameter setting the switching of room control modes and an activation of on-site comfort prolongation can be locked by the button. Rotary knob The control is supplied with two rotary knobs: one inserted in the control for shifting the basic target value to a higher or lower value and a second for directly setting the target value in the range of 16 to 26 C. If instead of shifting the target value with the adjustable shifting range, direct target value setting in degrees Celsius is desired, then the inserted rotary knob should be exchanged with the delivered rotary knob and the parameter "target value setting" should be switched to "directly in C" in the "Functions / objects" parameter window. Note: Via a parameter setting the setting of setpoint value respectively setpoint value shifting can be locked by the rotary control. Siemens AG UP 237K,, 5 pages Technical-Manual 2.8.2.8/1

Technical Product-Information Commissioning For commissioning a control with the help of ETS (Engineering Tool Software), the control together with the suitable DELTA frame must first be inserted into a Bus Transceiver Module (BTM) UP 117 which serves to supply power to the control and to transmit data via the KNX Bus. After removing the rotary knob for target value shifting, the recess for the commissioning button and the commissioning LED of the control are visible. Note: The bus transceiver module UP 117 and the associated DELTA frame are not supplied and must be ordered separately. With the help of ETS, the application program can be selected, the specific parameter and addresses assigned and transferred into the room temperature controls UP 237K and. Application program The "0705 CO Room Temperature Control H+K 803002" application program supports the following functions: Switching between automatic / manual operation and switching the room operating mode with the button, Target value shifting or target value setting in C with the rotary knob, Status display with LEDs: - Displays (green) for manual operation and the current room operating mode (comfort, pre-comfort, energy-savings and protection mode), - Displays (red/yellow), whether the heating or cooling valve is open, - Displays (red) for dew point alarm and open window. Room temperature control, adjustable as: - heating only, cooling only, heating and cooling, each selectable as - heating with two-point control, - heating with PI control, - heating with PI control and sequence control (e.g. with floor and radiator heating), - cooling with two-point control, - cooling with PI control, - cooling with PI control and sequence control. (e.g. with cooling ceiling and supply air cooler). The following partial functions are part of room temperature control: - Room temperature measurement using the internal temperature sensor with Offset setting, - Room temperature measurement using an external temperature sensor with Offset setting, - Computation of current room temperature actual value (internal and external sensors weighted), - With target value shifting: Basic target value assignment via parameter setting and/or via Bus, - With target value shifting: Computation of current room temperature target value from basic target value and shifting, - time-restricted removal of night sinking or the protection mode (comfort prolongation), - with presence detection via the Bus, switching to the "comfort" operating mode occurs, - Dew point mode can be activated via the Bus, - Evaluation of the window conditions via the Bus, - Frost protection / heat protection are reported via the Bus, - PI control for heating / cooling with constant regulating variable-output (in %) or toggling regulating variables-output (on / off). - Separated or joint regulating variable output for heating and cooling, - Separated regulating variable output for basic level and auxiliary level for 2-level heating or cooling, - Switching the desired effect and scaling the regulating variable for heating/cooling is possible, - Maximal and minimal regulating variable for heating/cooling possible, - Operating condition (control status) can be read out via the Bus, Technical Data Power supply via the flush-mounted bus transceiver module UP 117 Operating elements 1 rotary button for manual adjustment of the setpoint (control range and type of adjustment dependent on the parameter setting and type of rotary button) 1 button for toggling of the room operating mode and vice versa Display elements 5 green LED`s for the current operating mode (comfort, pre-comfort, energy-saving, protection mode) and for manual mode 2 red LED`s for dew point alarm and open window 2 red/yellow LED`s for Heating / cooling mode Temperature measurement Measuring range: 0... + 40 C Resolution: 0.08 K Accuracy of the sensor temperature: ± 1.0 K under reference conditions, ± 2.0 K under ambient conditions and in measuring range Connections 10-pole plug-in connector for connection with the bus transceiver module UP 117 Technical-Manual UP 237K,, 5 pages Siemens AG Update: http://www.siemens.com/gamma ã Siemens AG 2014 Control Products and Systems Subject to change without further notice. P. O. Box 10 09 53, D-93009 Regensburg 2.8.2.8/2

Technical Product Information Mechanical data Casing: plastic Dimensions: - Temperature controller UP 237K for DELTA i- system (L x W x D): 55 x 55 x 16 mm (without spring) - Temperature controller for DELTA style (L x W x D): 68 x 68 x 20 mm (without spring) Weight: approx. 30 g (UP 237K) Weight: approx. 40 g () Fire load: 730 KJ ± 10 % Mounting: The operator panel is attached to the BTM UP 117 and screwed to its mounting frame. Electrical safety Degree of pollution (according to IEC 60664-1): 2 Type of protection (according to EN 60529): IP 20 Protection class (according to IEC 61140): III Overvoltage categorie (according to IEC 60664-1): III Bus: Safety extra-low voltage SELV DC 24V Device complies with EN 50090-2-2 Reliability Failure rate: 214 fit at 40 C EMV requirements Complies with EN 61000-6-1 and 50090-2-2 Environmental conditions Climatic withstand capability: EN 50090-2-2 Ambient operating temperature: - 5... + 45 C Storage temperature: - 25... + 70 C Relative humidity (not condensing): 5 % up to 93 % Markings KNX EIB CE mark In accordance with the EMV guideline (residential and functional buildings), low voltage guideline Location and function of the operating and display elements A6 A7 A8 A9 A10 A1 A2 A3 A4 A5 figure 1: Location of the operating and display elements A1 LED green: illuminates during manual mode A2 LED green: lights up continuously in comfort mode and blinks slowly in comfort prolongation. A3 LED green: illuminates during pre-comfort mode A4 LED green: illuminates during energy-saving mode A5 LED green: lights up continuously in protection mode, blinks slowly in permanent protection mode A6: Pushbutton for selection of room operating mode A7: LED red: illuminates with dew point alarm A8: LED yellow: illuminates if cooling valve is open A9: LED red: illuminates if heating valve is open A10: LED red: illuminates if open window A11: Rotary button for manual setpoint shifting (shifting range dependent on parameter setting) or for setpoint adjustment in C Mounting, wiring and commissioning General description The temperature controller is attached with the associated DELTA frame to the BTM UP 117 and screwed to its mounting frame. Mounting and commissioning (see figure 2) - Attach the bus cable and fix the BTM UP 117 (B8) on the flush socket (see mounting instructions for BTM UP 117) - Remove rotary knob (B1 or B2) from the temperature controller (B3) - Attach temperature controller with DELTA frame (B4) to the BTM UP 117 and secure using screw (B5) - Press programming button (B7): programming LED (B6) illuminates - Load physical address and the configures application program by means of the ETS Siemens AG UP 237K,, 5 pages Technical-Manual 2.8.2.8/3

Technical Product-Information - Replace rotary knob (B1 or B2). B8 Mounting location (see figure 3) Observe the following points when mounting the controller: B7 B6 Controller mounted on interior wall of room to be conditioned, vis-á-vis the heat source: figure 2: Mounting controller B1 Rotary button for setpoint shifting B2 Rotary button for setpoint adjustment in C B3 Temperature controller heating / cooling B4 DELTA frame B5 Screw for securing the controller to the mounting frame of the UP 117 (anti-theft protection) B6 LED for displaying normal mode (LED Off) or address mode (LED On); it is automatically extinguished once the physical address has been transferred B7 Button for toggling between normal mode/addressing mode for transferring the physical address B8 Bus Transceiver Module UP 117 B2 B1 B4 B3 B5 At ca. 1.5 m height in the room and at least 50 cm from the next wall. Not on outside walls. Not in niches or behind curtains. Not above or near heat sources or shelves. Not on walls covering heat sources such as a chimney. Not in the radiation range of heat sources and lighting bodies e.g. spotlights. Not in areas exposed to direct solar radiation. The air draft of windows and doors have to be avoided! Installation instructions The device can be used for fixed installations, in dry interior spaces and for integration into a flush socket. Υ WARNING The device must be mounted and commissioned by an authorised electrician. The device may not be inserted in the same box as 230 V devices. The device may be mounted in switch and socket combinations if VDE-certified devices are used exclusively. The prevailing safety rules must be heeded. The device may not be opened. For planning and construction of electric installations, the relevant guidelines, regulations and standards of the respective country are to be considered. figure 3: Installation references for sensors and temperature controller. Seal the end of the installation conduit to prevent false measurements due to air drafts, see figure 4. figure 4: Sealing installation conduit Technical-Manual UP 237K,, 5 pages Siemens AG Update: http://www.siemens.com/gamma ã Siemens AG 2014 Control Products and Systems Subject to change without further notice. P. O. Box 10 09 53, D-93009 Regensburg 2.8.2.8/4

Technical Product Information Dismantling (see figure 2) - Remove rotary knob (B1 or B2) - Loosen screw (B5) - Remove controller together with DELTA frame. - Remove BTM UP 117 (B8) according to dismantling instructions. Dimension Drawing DELTA i-system temperature controller UP 237K Dimensions in mm 55 55 16 DELTA style temperature controller Dimensions in mm 68 68 20 General Notes The operating instructions must be handed over to the client. Any faulty device is to be sent together with a return delivery note of the local Siemens office. If you have further questions concerning the product please contact our technical support. Siemens AG UP 237K,, 5 pages Technical-Manual 2.8.2.8/5