USER MANUAL. MODEL 1000P Non-Powered Short Haul Modem. SALES OFFICE (301) TECHNICAL SUPPORT (301)

Similar documents
An ISO-9001 Certified Company

USER MANUAL. MODEL 1003 and 1003S Asynchronous, 2-Wire, Carrier Sense Short Range Modem

USER MANUAL MODEL 2017P MODEL 2017P60. RS-232 to 20mA and. RS-232 to 60mA Current Loop Converters

RS-232/RS-422 Optical Isolator

Miniature Asynchronous 4-Wire High Speed Modems

USER MANUAL. MODEL 1018 High Speed Short Range Modem w/ Extra Controls SALES OFFICE (301) TECHNICAL SUPPORT (301)

Data Sheet SRM-6A. Short-Range Asynchronous Modem. The Access Company

Interface Converter. Installation Manual IC485S IC485SGB IC485SEU. RS-232 to RS-485/422 Serial Interface Converter

RS RS-485 INTERFACE CONVERTER IC-485S & IC-485SI. User s Manual

USER MANUAL. MODEL 1225 ParaLink TM Parallel Short Range Modem. SALES OFFICE (301) TECHNICAL SUPPORT (301)

USER MANUAL. MODEL 1052 idsl Modem with RS-232 Interface. An ISO-9001 Certified Company SALES OFFICE (301) TECHNICAL SUPPORT (301)

IC-485S /IC-485SI. If anything is damaged or missing, contact your dealer.

FCC Information. RoHS This product is RoHS compliant. SJ/T The following contains information that relates to China.

USER MANUAL MODEL 222N9. Ultra-miniature RS-232 (EIA-574) to RS-422 Interface Converter

ADAM-4510 RS-422/RS-485 Repeater ADAM-4510S Isolated RS-422/485 Repeater ADAM-4520 Isolated RS-422/485 Converter Startup Manual


DB9 Microdriver CUSTOMER SUPPORT INFORMATION JULY 1994 ME792A ME793A ME794A

TRP-C06H User s Manual

PCI Hardware Installation

HomeVision-Serial. Add-On Card. Installation and Operation Manual

USER MANUAL MODEL KiloModem II AC Powered, High-Speed X.21 Short-Range Modem

RocketPort Plus Hardware Installation

USER MANUAL MODEL Bidirectional (IEEE-1284) Line Driver/Converter

USER MANUAL. MODEL 2014 Interface Powered RS-530 to V.35 Converter. SALES OFFICE (301) TECHNICAL SUPPORT (301)

RCS/6000. Hardware. Manual

Industrial Serial RS-232 to Fiber Converter. KSC-200 Series. Installation Guide

Hardened Ethernet to VDSL2 Extender. User Guide. Revision History. Industrial Ethernet to VDSL2 Extender with Wide Operating Temp. Rev.1.

TRP-C08S. USB To 1* RS232 and 1*RS422/485 Isolated Converter. User s Manual. Printed Jun Rev 1.2

TRP-C08S. USB to 1 RS232 and 1 RS422/485 Isolated Converter. User s Manual

Mini Driver V (Mini Driver MP with 5-Screw Terminal Block) MINI DRIVER MP

USER MANUAL MODEL 505M-CHC. Surge Protected DB-25 to RJ-45 Modular Adapter

Multi-Channel RS-232 Current Loop Interface Converter (CLIC)

Data Sheet SRM-3A. Ultra-Miniature Isolated Short-Range Async Modem. The Access Company

USER MANUAL. MODEL 2011 High Speed Asynchronous to Synchronous Converter

10/100/1000T to Mini-GBIC Industrial Switch Converter 10/100/1000T to 1000SX/LX Industrial Switch Converter. AMG9011G-H (-40 to 75C) User Manual

4-port 10/100TX + 1 or 2-port 100FX Industrial Switch. User Manual

Lantech. IPES /100TX with 4 PoE Injectors 24~48VDC Industrial Switch. User Manual

ME778C-RJ45 MAIN MODULE (FRONT CARD) MAIN MODULE. Line: RJ-45. Line: RJ-45 INTERFACE MODULE (REAR CARD) Serial: 10-Pin RJ.

Information. Installation. Remove Driver Software. Technical And Operational Description. Connections. Specifications. Note FCC COMPLIANCE STATEMENT

Installation Guide of Hi-Speed USB-to-Optically Isolated RS-422/485 Adapter

and Network Interface Modules Installation Instructions

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

Introduction. General Ratings

Introduction. Technical Support:

IEC-0101FT Industrial 10/100TX to 100M-FX Slim Type Converter User Manual

MC 11 EB-2 Power supply cabinet with external bus, AC version

IEEE BASE-T IEEE 802.3u 100BASE-TX. ITU-T -G.993.1(VDSL) -G compatible

ME500A BLACK BOX SPECIFICATIONS: BOTTOM OF UNIT INTRODUCTION: CONFIGURATION: Async Sync Industrial Line Driver PWR TX RX RTS CD. DB25 Female Conn.

Product Overview. Interface Converters and Plug-in Modules

RS-422/485 to Fiber Industrial Converter

6 10/100/1000TX + 2G Fiber Industrial Ethernet Switch User Manual

4 10/100/1000T Mini-GBIC with 4 IEEE 802.3at High Power PoE Industrial Wide Temperature Switch. User Manual SISTP LRT

ZM24x Quick-Connect Industrial Modem. User s Manual

ASYNC/MULTIDROP DB-25, DB-9. LOW SPEED UNITS Basic Multipoint Long Range & Multipoint ASYNC/SYNC

Hypercable injecteur HPOE - Industrial IEEE 802.3at Gigabit PoE Injector. User Manual. v.1.0 Jun Mail :

USB to RS-485/RS-422 Interface Converter. User Manual

USER MANUAL. MODEL 1082 and 1082/144 idsl Modem with V.35 or X.21 Interface. An ISO-9001 Certified Company

Model 282 Total Interface Isolation Module Reference Manual Rev. A Print Table of Contents 1.0 General Description 2.

Miniature Asynchronous Modems

Lantech. IPGS-0204DSFP 4 10/100/1000T PoE at/af + 2 Dual Speed SFP Industrial Unmanaged Switch

24-Port Gigabit Ethernet Switches

MED102A. Industrial Serial to Single-mode Fiber Converter

MDI/MDIX) FEP-32005T-2

DSU 5600 Data Service Unit USER MANUAL

TRITON routing switcher

Note: For BANDIT II, BANDIT III, or VSR-1200 specifications, see the BANDIT II, BANDIT III, and VSR-1200 Document Set. Function

Perle MCR200 Installation Guide

TRP-C08X. USB To 4 RS232/422/485 Converter. User s Manual

Windows-Based Terminal. TK-3550 H.W. Manual

EasySync Ltd. ES-R-2x01-M RS232 to RS422 / RS485 Converter. User Guide. Document Reference No.: ES_ Version draft Issue Date:

F1000 User's Manual. (Version: V1.01)

KSD-800 Series. Installation Guide. Industrial 8-Port Fast Ethernet Switches with Fiber Connectivity DOC A -1-

Hardware Installation & Reference Manual Megaport SS Serial I/O Board Series

8-port 10/100Base-TX Switch (INS-806) User s Guide

D56 Modem TABLE OF CONTENTS SECTION 1 - DESCRIPTION...4 SECTION 2 - SPECIFICATIONS...6 SECTION 3 - INSTALLATION...7

LNP series. 5-port Industrial PoE+ Unmanaged Ethernet Switches 4*10/100Tx (30W/Port) + 1*10/100Tx, 12~36VDC Input.

DeviceMaster RTS 16-Port Hardware Installation

INSTALLATION GUIDE. Remote RMM-700 Intelligent Site Management Device. Installation Guide WESTELL.COM

Industrial 3-Port Fast Ethernet Media Converter Switches

Media Converters. Media Converters. Product Selection Guides

USB-TTL-5 PRODUCT IS A COMBINATION OF PRODUCTS USB AND TTL-232-5P BOTH DATASHEETS ARE INCLUDED IN THIS PDF FILE

Bluetooth to RS-232&RS422/485. EX-9132B/BI Bluetooth Adapter Operation Manual

converter Tel: Fax:

Serial Communication Prof. James L. Frankel Harvard University. Version of 2:30 PM 6-Oct-2015 Copyright 2015 James L. Frankel. All rights reserved.

Active RFID Reader User Manual

Moxa TCC-100 Series User s Guide

ICD105A 1008 page 1/ r001 ICD105A. Industrial RS-232 to RS-422/485 Converter

Overview of the Cisco 2524 and Cisco 2525 Routers

8-port 10/100TX + 2-Port 10/100/1000T/100/1000 SFP Combo with 8 PoE Injectors Industrial Ethernet Switch User Manual

LNP-0602 series. 6-port Industrial PoE+ Unmanaged Ethernet Switches 4*10/100Tx (30W/Port) + 2*100Fx. User Manual

Industrial Media Converters

F2238A and F2245A Fiber-Optic EIA-530/MIL-STD Modem Technical Manual

Lantech. IPGS-0005T /100/1000T PoE at T Industrial Unmanaged Switch. User Manual

Industrial 5-Port Fast Ethernet Switches with SFP Slot and optional 4 PoE PSE Ports. Basic Model: KSD-541 PoE Model: KSD-541-P. Installation Guide

DATA CONNECT ENTERPRISE

Installing the DX LCD Display

MODEL DSU Kbps Rack Mount CSU/DSU OPERATOR S MANUAL. 280 I-80 West Exit 1 PO Box 1330 Verdi NV 89439

SOHO Access TM Module. User Guide. SAM-SW5U: 5-port 10/100 Ethernet Switch

Moxa TCC-100 Series Hardware Installation Guide

TRP-C08M. USB To 4 RS232/422/485 Isolated Converter. User s Manual. Printed Jun Rev 1.0

Transcription:

USER MANUAL MODEL 1000P Non-Powered Short Haul Modem C E R T I F I E D An ISO-9001 Certified Company Part #07M1000PA Doc. #022031UA Revised 2/17/98 SALES OFFICE (301) 975-1000 TECHNICAL SUPPORT (301) 975-1007 http://www.patton.com

RADIO FREQUENCY INTERFERENCE STATEMENT This equipment generates, uses and can radiate radio frequency energy and if not used in accordance with this manual, may cause interference to radio communications. It has been tested and found to comply with the limits for a Class A computing device pursuant to Subpart J of Part 15 of FCC rules, which are designed to provide reasonable protection against such interference when operated in a commercial environment. Operation of this equipment in a residential area is likely to cause interference in which case the user at his own expense be required to correct the interference. If this unit is used on a DTE/DCE which requires use of shielded cables for compliance with FCC Part 15, then use of a filtered-pin connector may be required to maintain FCC compliance. 1.0 SPECIFICATIONS Operating Environment: 32 to 112 F (0 to 45 C), 0 to 95% relative humidity Date Rates: Transmission Format: Transmission Mode: Connectors - RS-232: Connectors - Line: 19,200 bps (according to the RS- 232 interface) Asynchronous Full duplex 1000PM - DB-25 male 1000PMRJ11 - DB-25 male 1000PMRJ45 - DB-25 male 1000PF - DB-25 female 1000PFRJ11 - DB-25 female 1000PFRJ45 - DB-25 female 1000PM - strain relief 1000PMRJ11 - RJ11 (6 wire) 1000PMRJ45 - RJ45 (8 wire) 1000PF - strain relief 1000PFRJ11 - RJ11 (6 wire) 1000PFRJ45 - RJ45 (8 wire) Dimensions: 2.20" x 1.75" x.75" Weight: Power: Powered from RS-232C Connector (+12V DTR/DSR), 6.3 ma) These units derive power from a terminal or computer. The following signals must be available at the RS-232 connector: DCE Configuration of the 1000P when connected to a DTE: Surge Protection: Compliant with IEC 801.5 level 2, 1kV (Model 222NS Only) Factory Switch Setting: DCE; data is received from the remote short range modem via RX+ and RX-, and is sent to the DTE from the Model 222N via pin 3 of the RS-232 interface; (the RS- 232 interface is the DB-25 connector closest to the DTE/DCE switch). The - and + voltage is taken from pins 2, 4, 9, and 20. DTE Configuration of the 1000P when connected to a DCE: The - and + voltage is taken from pins 3, 5, 6, 8, or 9. NOTE: When power is removed from the DCE or DTE to which the Model 1000P is connected, the 1000P can no longer send a signal to the remote receiver. Under this condition, the idled cable is susceptible to noise reception. The remote receiver may output erroneous data bits as a result of noise. 1 Cable Type: 4-wire, unloaded, customer-owned twisted pair cable with DC continuity 2

RS-232 Signals: Table 1. Model 1000P Transmission Distances PIN CIRCUIT DESCRIPTION SIGNAL TYPE DIRECTION 1 AA Protective Ground Ground 2 BA Transmitted Data Data To DCE 3 BB Receive Data Data From DCE 4 CA Request to Send Control To DCE 5 CB Clear to Send Control From DCE 6 CC Data Set Ready Control From DCE 7 AB Signal Ground Ground 8 CF Data Carrier Detect Control From DCE 9 DC Voltage 20 CD Data Terminal Ready Control To DCE Pins 1 and 7 are tied together Pins 4 and 5 are tied together Pins 6, 8 and 20 are tied together DATA RATE (BPS) 19 AWG ( 0.9 mm) Wire Gauge 24 AWG ( 0.5 mm) 26 AWG ( 0.4 mm) 19,200 6.2(9.9) 3.7(5.9) 1.2(1.9) 9,600 7.5(12.0) 4.9(7.8) 2.5(4.0) 4,800 8.7(13.9) 5.6(9.0) 3.7(5.9) 2,400 11.8(18.9) 8.0(12.8) 4.9(7.8) 1,200 17.0(27.2) 11.8(18.9) 8.0(12.8) These distances are for a noiseless environment with 20% or less of peak-to-peak gross distortion. Distances and rates listed are 1000P to 1000P 2.0 DESCRIPTION The Model 1000P Asynchronous Short Range Modem uses the latest surface mount technology to attain high quality short range modem performance in a low profile package. The unit operates full duplex at data rates to 19.2 Kbps over 2 twisted pair. Requiring no AC power or batteries, the Model 1000 supports distances to 17 miles (27.2km). The Model 1000P has the option of being configured as either DCE or DTE devices. Set the switch located on the top of the printed circuit board to the DCE or DTE position NOTE: You do not have to open the plastic case to change the switch setting. With an externally accessible DCE/DTE switch, the Model 1000P allows easy connection to any device without opening the unit. Three enclosure options allow terminations to be via RJ-11, RJ-45 or terminal blocks. A unique strain relief prevents thin twisted pairs from breaking or pulling loose. DCE DTE The Model 1000P uses the latest in bi-directional, clamping, transient suppressors to protect itself and connected equipment against harmful transient discharges. For surge handling capability, the Model 1000P is compliant with IEC 801.5 level 2, 1kV. Figure 1. Model 1000P DCE/DTE Switch 3 4

The Model 1000P meets the requirements for FCC Part 15 (RFI limits for Class A peripheral devices). RS-232 Connection (Male or Female) DCE/DTE Switch Surge Suppressors FEMALE PINS 1 2 3 4 5 6 MALE 2 (RXB) 3 (TXB) 4 (TXA) 5 (RXA) DCE DTE Screws for Terminal Block FEMALE Figure 3. Pin Assignments for RJ11 Connectors MALE Figure 2. Components of Model 1000P PINS 1 2 3 4 5 6 7 8 3 (RXB) 4 (TXB) 5 (TXA) 6 (RXA) 3.0 INSTALLATION All versions of the Model 1000P plug directly into the back of a terminal or computer. This eliminates the need for an RS-232C data cable. No power is required from an external source because the unit is powered entirely by the terminal or computer s control and data signals. The Model 1000P has an interface connection at each end: one for Data Terminal Equipment (DTE) or Data Communications Equipment (DCE), and one for the telephone line (twisted pairs). To install the unit, perform the following steps. 1. Connect the twisted pair cable (customer-supplied) to the 4-screw terminal block (Model 1000PM or 1000PF), RJ11 jack (Model 1000PMRJ11 or 1000PFRJ11), or RJ45 jack (Model 1000PMRJ45 or 1000PFRJ45). Refer to Figure 3 for the associated pin assignments. End-to-End connections should be matched as shown in Figure 6. Figure 4. Pin Assignments for RJ45 Connectors TXA TXB RXA RXB RXA RXB TXA TXB Figure 5. Four-Wire, Full-Duplex, Point-to-Point Link 2. When the 1000P has been cabled connect the telephone interface cable to the telephone outlet. 5 6

3. If the unit is to be used as a DTE, set the externally accessible DCE/DTE switch to the DTE position. If the unit is to be used as a DCE, set the externally accessible switch to the DCE position. (If you are uncertain as to how your equipment operates, try each of the settings to see which one works in your application. - NOTES 4. Plug the unit s interface connector end into the RS-232C connector on the DTE or DCE, and tighten the connector mounting screws. For examples of typical applications of the Model 1000P with DTE or DCE devices, refer to Figure 6, below. Model 1000Ps Async MiniComputer Customer-Owned Unloaded Twisted Pair Cable Async Terminal Model 1000Ps PC Customer-Owned Unloaded Twisted Pair Cable Printer Figure 6. Typical Short Range Modem Applications 7 8