DI-917MB/DI-918MB. Heavy-duty 1A solid-state relays provide dependable on/off control of industrial devices. Analog Output Module. Four Analog Outputs

Similar documents
DI-924MB. Thermocouple/Millivolt Input Module

DI-904MB/DI-905MB/DI-906MB

DI-932MB/DI-934MB. RTD/Resistance Input Module. Four RTD or Resistance Inputs

DI-942MB. Frequency/Counter Module. Two Frequency or Pulse Waveform Inputs

Modbus I/O. 904MB active high inputs MB sourcing outputs MB active high inputs, sourcing outputs Analog I/O Modules

895/896M Frequency Output Math Modules

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

900MB Series. Analog Output Module. Four Analog Outputs. DC Current or DC Voltage. Description

DI-900MB Series Modbus/RS485 Network I/O Modules. Model DI-901MB/DI-902MB/DI-903MB. User s Manual. The way PC-based instrumentation should be

DI-900MB Series Modbus/RS485 Network I/O Modules. Model DI-904MB/DI-905MB/DI-906MB. User s Manual. The way PC-based instrumentation should be

MODEL CIO-EN MODBUS/TCP, MODBUS/RTU I/O MODULE

DI-900MB Series Modbus/RS485 Network I/O Modules. Model DI-932MB. Model DI-934MB Quad RTD Input/Digital Output. User s Manual

800 Series. Strain Gauge / Load Cell Transmitter with Alarm. exc + sense + bridge + bridge sense exc

TM3TI4 module TM3-4 inputs temperature

TM3AI4 module TM3-4 analog inputs

OTB1S0DM9LP I/O distributed module OTB - Modbus non isolated serial link m

SCM5B. SLX200 Data Acquisition System. isolynx. Data Acquisition Systems. Visit our website Features

DI-900MB Series Modbus/RS485 Network I/O Modules. Model DI-924MB. User s Manual. The way PC-based instrumentation should be.

900EN Series. Acromag RUN ST DIO STATUS ACT LINK DFT RST ETHERNET TB1

TM3TM3 module TM3-2 temperature inputs and 1 analog output

TM3TI4 module TM3-4 inputs temperature

D7000 SERIES MODBUS TCP/IP ETHERNET INTERFACE MODULES

P3-SCM. General Specifications

OTB1S0DM9LP I/O distributed module OTB - Modbus non isolated serial link m

TM3TI8T module TM3-8 inputs temperature

Table of Contents. Introduction... 2 Description...2 Specifications...3 Installation.. 5 Calibration.. 6 General Maintenance...7

LAUREL. Laureate Pulse or Analog Input Batch Controller Automatic batch control for repetitive liquid fill operations ELECTRONICS, INC.

Produkt-Datenblatt. Technische Daten, Spezifikationen. MEsstechnik fängt mit ME an. Kontakt

Analog Voltage Combination Module

LAUREL. Laureate Dual-Channel Pulse Input Totalizer With Two Independently Scalable Input Channels & Presets ELECTRONICS, INC. Features.

OTB1E0DM9LP I/O distributed module OTB - Ethernet TCP/IP m

iologik 4000 Series Modular remote I/O Introduction iologik E4200 Specifications Remote I/O Slice Form Factor and Flexible I/O Variety

TC Type Range Conformity Error. J -210 C to +760 C (-347 F to F) ±0.09 C (±0.16 F) K -244 C to C (-408 F to F) ±0.1 C (±0.

LAUREL. Laureate RTD Temperature Panel Meter / Controller ELECTRONICS, INC. Features. Description. Specifications

Media Converters. Media Converters. Product Selection Guides

SmartMod DC Digital Input Module HE359DIM610 12/24VDC Negative Logic

INSTALLATION INSTRUCTIONS. Revision C1 Rapid City, SD, USA, 02/2010 MODEL ALT-XXX-3-SW

SP SP-T-9

SDM-8AO. Expansion Module 8 analog outputs. Manufactured for

12-36 VDC/12-24 VAC Power Option 4-Digit Display, 0.56 (14.2 mm) or 1.20 (30.5 mm)

8B SLX300 Data Acquisition System

ATV930U30M3 variable speed drive - ATV930-3kW - 200/240Vwith braking unit - IP21

IB ST 24 AO 4/EF. INTERBUS-ST analog output module, 4 outputs, 0-10 V, ±10 V, 0-20 ma, 4-20 ma. Data sheet. 1 Description

8-Port Industrial USB to RS-232/422/485 Serial Adapter - 15 kv ESD Protection

D1000M SERIES FOR MODBUS SENSOR TO COMPUTER INTERFACE MODULES

Electronic timer CT-ERD.12

RS485 MODBUS Module 8AO

- SELF-TUNING PID ALGORITHM - INTUITIVE COLOR DISPLAY WITH TEXT MESSAGING - UNIVERSAL PROCESS AND TC/RTD INPUTS - MULTI- FUNCTION RAMP- DWELL/PROCESS

Electronic timer CT-ERS.21

RS485 MODBUS Module 6RO

Industrial 2-port RS422/485 Modbus Gateway

Features and Benefits. Certifications

SDM-6RO. Expansion Module 6 relay outputs. Manufactured for

iologik E1200H Series

OTB1E0DM9LP I/O distributed module OTB - Ethernet TCP/IP m

Electronic timer CT-ARS.11

Produkt-Datenblatt. Technische Daten, Spezifikationen. MEsstechnik fängt mit ME an. Kontakt

Quantum III. Compact DC Drive Package. Slitter DC Drive Package. Quantum III

1/32-DIN TEMPERATURE CONTROLLER INSTALLATION, WIRING AND OPERATION MANUAL FORM 3882

Rugged MediaConverter

Electronic timer CT-ERS.12 ON-delayed with 1 c/o contact Data sheet

TM241C40U controller M IO transistor NPN

OTB1C0DM9LP. Main , length of segment <= 185 m , length of segment <= 160 m. 3.4 kohm for I8...I kohm I0...I1 5.7 kohm I6...

TM241C24T controller M IO transistor PNP

OTB1C0DM9LP I/O distributed module OTB - CANopen bus m

Ethernet I/O: BusWorks XT Series

OTB1C0DM9LP I/O distributed module OTB - CANopen bus m

XPSMF35. Product data sheet Characteristics. Preventa safety PLC compact - Profibus DP protocol. Main. Complementary. Safety module name

Trident and Trident X2 Digital Process and Temperature Panel Meter

MicroLogix 1000 Programmable Controllers

RS 485 Mini Modbus 1AO

TM241CE24T controller M IO transistor PNP Ethernet

High Voltage DC Meter

TM241C40R controller M IO relay

Electronic timer CT-AHD.22

iologik R1200 Series User s Manual

MGate 4101-MB-PBS Series

Isolated Current Output 5B39 FEATURES APPLICATIONS PRODUCT OVERVIEW

PGR-3200 MANUAL INSULATION MONITOR

TM241CE24T controller M IO transistor PNP Ethernet

OTB1E0DM9LP I/O distributed module OTB - Ethernet TCP/IP m

LAUREL ELECTRONICS, INC.

TM241CE40R controller M IO relay Ethernet

TM241CE40R controller M IO relay Ethernet

Intech Micro 2300-RO4 analogue input station MODBUS RTU slave application supplementary manual.

PC-200-LLC-GM INSTALLATION INSTRUCTIONS. Revision A1 Rapid City, SD, USA, 10/2009 II_PC-XXX-LLC-GM_A1

TM241CE40T controller M IO transistor PNP Ethernet

TM241CEC24R controller M IO relay Ethernet CAN master

MOD-IO9 Modbus Input / Output Modules, Wall Mounted

RS-485 I/O Modules: ADAM-4000

HIT/HIX HART Isolator

PDW30 Point-To-Point Wireless Bridge

TM241CE24T controller M IO transistor PNP Ethernet

ICD105A 1008 page 1/ r001 ICD105A. Industrial RS-232 to RS-422/485 Converter

TM221M16R controller M IO relay

MICROFUSION FEATURES OPTIONS CERTIFICATIONS (PENDING) THREE PHASE SCR POWER CONTROLLERS

HMISBC Rear Module controller panel - Dig 8 inputs/8 outputs +Ana 4 In/2 Out

TM3DI16 module TM3-16 inputs

TM241CE24U controller M IO transistor NPN Ethernet

Sorensen DLM 600 Series W V 2 75 A. Half Rack Programmable DC Power Supply

Transcription:

Multi-Channel Analog Output Modules DC Current or DC Voltage Outputs Discrete Outputs DI-917MB/DI-918MB Models DI-917MB: 4 current output channels DI-918MB: 4 voltage output channels Analog Output DI-917MB: 0 to 20mA, 4 to 20mA, 0 to 1mA DC DI-918MB: 0 to 10V, 0 to 5V, 0 to 1V DC Discrete Output Four output channels: Open-drain MOSFETs (1A DC loads) 0 to 35V DC Network Communication Modbus-RTU high-speed Power Requirement 10 to 36V DC, 24V AC Approvals CE marked. UL, cul listed Class I; Division 2; Groups A, B, C, D. These modules drive four analog output channels and also feature four discrete outputs for on/off control. Isolation separates the output, power, and network circuits. Network communication adheres to the industry-standard Modbus RTU protocol. AC and DC power sources are supported with nonpolarized, diodecoupled terminals. The analog outputs generate a signal based on communication from the host. They accommodate wide DC voltage or current ranges. Discrete outputs provide simple on/off switching capability (open-drain) for external devices. Combining analog outputs, on/off controllers, and a network interface in a single package, makes this instrument extremely powerful. Multi-channel design adds cost-efficiency and allows high-density mounting. Plus, safe, rugged construction make it reliable for both control room and distributed field I/O use in a broad range of temperature control applications. Custom module configurations are also possible (consult factory for details). Standard Modbus RTU protocol with high-speed communication (up to 115K bps) 12-bit D/A yields 0.1% of span resolution and accuracy Four analog outputs in an inch-wide module reduces system costs and saves panel space Four discrete outputs enable hostcontrolled on/off switching Heavy-duty 1A solid-state relays provide dependable on/off control of industrial devices Analog Output Module Outputs (2) Outputs (2) Four Analog Outputs DC Current or DC Voltage Features Isolation Self-calibration lowers maintenance costs by reducing periodic manual calibration checks Watchdog timers provide a configurable failsafe output state for use when host I/O communication is lost Three-way isolation eliminates potential ground loops between power, output, and network circuitry Self-diagnostics monitor microcontroller activity to detect operational failures (lock-up) and execute a reset to restore communication Four Discrete Outputs 10-36V DC or 24V AC Outputs (4) Modbus Power

General Analog Output Resolution See current/voltage output specifications for more information. Ambient Temperature Effect Better than ±0.001% of output span per C, or ±1.0uV/ C, whichever is greater. Ambient Temperature Operation (917MB): -25 C to 60 C* (-13 F to 140 F*). Operation (918MB): -25 C to 70 C (-13 F to 158 F). Storage: -40 C to +85 C (-40 F to +185 F). * Limit 917MB maximum ambient to 50 C (122 F) when using supply voltages less than 15V DC. Current Output (DI-917MB) DC Current Output Ranges Range user-configured. Range selected applies to all channels. Output Range Resolution Accuracy (% span) 0 to 1mA 0.554% ±2.0% (±0.002mA) 0 to 20mA 0.028% ±0.1% (±0.02mA) 4 to 20mA 0.035% ±0.1% (±0.02mA) Maximum Output Current 22.5mA DC typical. Integral Non-Linearity ±0.1% of span or ±2 LSB typical, whichever is larger, for spans equal to or greater than 16mA. Output Compliance 12V minimum, 12.7V typical. Output Load Resistance Range 0 to 630 ohms typical. Response Time 11ms typical into 500 ohms, for measurement to reach 98% of the final value in response to a step command. Actual response time will vary with load. Performance Voltage Output (DI-918MB) DC Voltage Output Ranges Range user-configured. Selection applies to all channels. Output Range Resolution Accuracy (% span) 0 to 1V 0.274% ±0.6% (±6mV) 0 to 5V 0.055% ±0.1% (±5mV) 0 to 10V 0.027% ±0.1% (±10mV) Maximum Output Voltage 11.255V DC typical. Integral Non-Linearity ±0.1% of span or ±2 LSB typical, whichever is larger, for spans equal to or greater than 5V. Output Current 0 to 10mA DC maximum. Output Impedance 1 ohm. Output Short Circuit Protection Included. Response Time 110μs rise time typical, 150μs fall time typical, unloaded, for output to reach 98% of the final value in response to a step command. Time varies with load. Discrete Output Output Type Four independent open drain MOSFET switches with a common return that operate as low-side switches. Output Voltage Range 0 to 35V DC (up to 1A/channel continuous). External voltage source required. Output ON Resistance 0.15 ohms maximum. Operation Digital outputs are set to their OFF state following a software or power-on reset. Outputs may be set to user-defined states following a watchdog timeout. Watchdog timeout output control takes precedence over limit alarm control. Alarm control takes precedence over host control. Output Response Time 4.1ms typical, from receipt of command to gate transition of the output MOSFET. Communication Supported Modbus Commands The command/response protocol for communicating with this module adheres to the Modbus/RTU standard for the following Modbus Functions. Read Coil (Output) Status Read Holding Registers Read Input Registers Force Single Coil (Output) Preset Single Register Force Multiple Coils (Output) Preset Multiple Registers Report Slave ID Reset Slave LED Indicators LEDs indicate power, status, and discrete level/alarm. Power and Isolation Power Requirements 10 to 36V DC (DI-918MB), 12 to 36V DC (DI-917MB) 22 to 26V AC. Supply Current Supply Current Draw (917) Current Draw (918) 10V DC Not Recommended 100mA max 12V DC 275mA maximum 85mA max 24V DC 120mA maximum 45mA max 24V AC 210mA rms max. 85mA rms max Isolation 1500V AC for 60 seconds or 250V AC continuous. 3-way isolation between outputs, network, and power circuits. ANALOG OUTPUT CONNECTIONS DC CURRENT OUTPUT + DC VOLTAGE OUTPUT + R L R L I / I+ / V+ ANALOG OUTPUT ANALOG OUTPUT 11 12 13 14 15 16 21 22 23 24 25 26 I0+ I1+ I2+ I3+ ANALOG OUTPUTS ANALOG OUTPUTS 11 12 13 14 15 16 21 22 23 24 25 26 V0+ V1+ V2+ V3+ ANALOG OUTPUTS ANALOG OUTPUTS DIGITAL OUTPUTS RS485 PWR TB4 OUT3 OUT2 OUT1 OUT0 TB3 COM COM D D B A 46 45 44 43 42 41 36 35 34 33 32 31 TB4 TB3 DIGITAL OUTPUT WIRING CONNECTIONS SAME AS 913/914MB NETWORK COMMUNICATION AC/DC POWER 10 TO 36V DC OR 24V AC NON-POLARIZED

900MB Technical Diagram TB4 TB3 "T" Rail Din Mounting Din EN 50022, 35mm RUN ST DFT 0 1 4.68 (118.9) TB4 46 45 44 43 42 41 TB3 36 35 34 COM COM D RS485 33 32 31 D B A PWR C L 2 3 3.75 (95.3) 2.34 (59.4) 11 12 13 14 15 16 21 22 23 24 25 26 1.05 (26.7) NOTE: ALL DIMENSION ARE IN INCHES (MILLIMETERS) 3.90 (99.1) 4.35 (110.5) Communication Connections

Software Interface Package DATAQ Instruments, Inc., provides a full set of tools to help you get your modules set up and ready to run in an easy-to-order package that includes the Windows Configuration Software, an RS-232 to Serial Port Converter, and an Signal Cable. The Software Interface Package Includes the following: Configuration Software for Windows (95, 98, ME, NT, 2000, XP) on CD-ROM. Non-isolated RS-232 to Serial Port Converter, DB-95 to DB-9F. to 3-wire Cable Converter, DB-9M to 3 x 12 AWG Cable, 8 ft. RS-232 to Converter (non-isolated) Cable (DB-9) RS-232/485 Converter (non-isolated) to 3-wire Windows Configuration Software The Windows Configuration Software provides an easy way to configure your module to whatever your application may be. The configuration software provides the following capabilities: Change Host and Slave communication settings (Baud Rate, COM Port, address, et al. Monitor the discrete I/O signal states and watchdog status allowing discrete outputs to be turned on/off. Allows a configuration to uploaded or downloaded to/from the module via the RS 485 interface. Provides controls the reset the module. Reads the contents of the Module Status Register. Allows optional user documentation to be saved with a module file. Allows a module's complete configuration to be printed in an easy-to-read, single-page format, including user documentation. Test page (right) simplifies diagnostics with a live visual display of the module's input and output values. RS-232 to Serial Port Converter This Serial Port Converter is a nonisolated, port-powered, RS232-to-RS485 signal converter. Although the converter receives its power from the RS232 data and Configuration Software for Windows 95/98/NT Model Number 100969 handshake lines, no handshaking lines are required to control the converter s RS485 driver. It plugs directly into the DB-9 male RS232 serial port connector on the back of most personal computers via the cable provided in the interface package. Software Support DI-900MB series products are designed for Modbus RTU compatibility. Modbus is a communication protocol developed by MODI- CON, Inc. in 1979. In the years since its release, Modbus has evolved into a truly open standard and has become the most widely used networking communication protocol in the industrial automation field. Virtually all SCADA and HMI application software packages can easily fold DI-900MB devices into any new or existing data acquisition and control environment. DI-900MB products support the RTU (Remote Terminal Unit) Modbus extension, which is a binary protocol providing enhanced performance. The following is a brief list of Human Machine Interface (HMI) software vendors who support the Modbus RTU protocol, and therefore support DI-900MB Series products. The space available does not allow an exhaustive list. Citect USA Tel # (704)-329-3838 Web: http://www.citect.com/ Modbus-RTU I/O support: DLL Driver - use Modicon PLC 484 Series; OPC Server supplied by others Intellution/GE Fanuc USA Tel. (508) 698-3322 Web: http://www.intellution.com/ Modbus-RTU I/O support: OPC Server supplied by Intellution Wonderware USA Tel. 949-727-3200 Web: http://www.wonderware.com/ Modbus-RTU I/O support: Driver Fast DDE; OPC Server supplied by others Iconics USA Tel. (508) 543-8600 Web: http://www.iconics.com/ Modbus-RTU I/O support: Driver supplied by Iconics; OPC Server supplied by others OPC Servers Vendors KEPware, Inc. USA Tel. 207-864-5881 Web: http://www.kepware.com/ Digital Systems, Inc. USA Tel. 704-895-7713 Web: http://www.caro.net/dsi/ Automated Solutions, Inc. USA Tel. 707-575-9631 Web: http://www.automatedsolutions.com/

Isolated Signal Converter This unit provides an isolated interface between the host PC's RS-232 port and Modbus network devices. Signal conversion is bidirectional with operation that is transparent to all devices. The network supports up to 32 devices (including the converter) across 4000 foot distances. Installation of additional network devices or extending the distance requires an Isolated Network Repeater (Model Numbers 100977 or 100978). Power cord included. Signal Cable (Model 100976) connects the PC s RS-232 Port to the Isolated Signal Converter. Specifications Baud Rates Switch-selectabe from 300 to 38.4K baud. Duplex Half duplex only. Network Termination Resistors Two terminal blocks and 120 ohm resistors provided to terminate both ends of the network. Wiring Connectors Terminal blocks with screw clamps for 14-26AWG Operating Temperature Range -25 to 60 C (-13 to 140 F) Isolation Withstands 1500V AC surge for 60 seconds (250V AC or 354V DC continuous). Model Numbers 100974 (115V AC Power) (discontinued) 100975 (230V AC Power) (discontinued) 100976 (8ft. long DB-9 to 3-wire RS-232 Cable) System Connection RS-232 Isolated RS-232/485 Signal Converter Model No. 100974 Daisy-Chain Topology Network: Up to 32 devices, 4000 ft. max.

Isolated Network Repeater This unit isolates and boosts signals to extend communication distances or increase the number of devices on the network. Each Repeater permits the addition of a network branch with up to 32 devices (including the Network Repeater) and will transmit signals another 4000 feet. Operation is transparent to all devices and no handshaking is required. Two terminal blocks are provided for 120 ohm resistors to terminate both ends of the network branch. Specifications Baud Rates Switch-selectable from 300 to 38.4K baud. Duplex Half duplex only. Network Termination Resistors Two terminal blocks and 120 ohm resistors provided to terminate both ends of the network. Wiring Connectors Terminal blocks with screw clamps for 14-26AWG. Power Wiring Connections Terminal block with screw clamps for 12-18AWG. Operating Temperature Range -25 to 60 C (-13 to 140 F). Isolation Withstands 1500V AC surge for 60 seconds (250V AC or 354V DC continuous). Model Numbers 100977 (115V AC Power) 100978 (230V AC Power) 100979 (115V AC Power Cord) Extending the Network Isolated Network Repeater Model No. 100977 To Network Host Network Branch: Additional 32 devices, 4000 ft. extension

Universal 50W Power Supply This Universal 50W Power Supply is the ideal power source to drive your network. 10-ø6.5 Top View (dimensions in mm) 7.35 Side View (dimensions in mm) 4-ø4.5 90 80 13 13 13 13 3.8 DC ON V.ADJ 60 75 35.3 Input Power Requirement Universal power 85 to 264V AC, 105 to 370V DC Output 24V DC, 2.1A (50W) M3.5 Terminal Screws 12 5 6 95 Model Number 100980 DIN-Rail Mounting For your convenience, DATAQ Instruments, Inc., offers a rack mount kit to simplify your system installation. This 19-inch kit provides a clean solution for mounting your I/O modules and a power supply. Holds up to 16 DI-900MB modules. USB to RS-232 Adapter Model Number 100971 Convert signals from RS-232 to USB with this convenient adapter. For use with all DI-900MB Series modules. Dimensions Length: 3.15 in (8.0 cm) Height: 0.80 in (2.03 cm) Width: 1.75 in (4.44 cm) Weight: 1.6 oz (45.36 g) Model Number 100970

General Module Specifi cations Communication Interface Watchdog Timer (Network Communication) Network Communication All modules have a communication Modbus-RTU protocol, RS485 (3-Wire). watchdog timer function. The watchdog Standard Protocol implementation timer is configurable for timeout periods as defined under Modicon Modbus of up to 18 hours. This timer function Reference Guide PI-MBUS-300 Rev. J. monitors I/O communications with Reference: http://public.modicon.com. the host controller. In the event of lost Search on: PI-MBUS-300 for technical communications, output ports optionally publication. reset to a user-defined state or level. The Baud Rate watchdog timer restarts with a read/write Enclosure/Physical 2400, 4800, 9600, 14.4k, 19.2k, 28.8k, to an I/O channel. 38.4k, 57.6k, 76.8k, or 115.2k baud. Default 9600 baud. Environmental Module Addressing Ambient Temperature 0 to 247, selectable. Default address 247. Operation: Network Distance -25 C to +70 C (-13 F to +158 F). 4000 feet without network repeater. Storage: Nodes -40 C to +85 C (-40 F to +185 F). Supports up to 32 modules without the use Relative Humidity of a network repeater. 5 to 95% non-condensing. Parity Radiated Field Interference Immunity Odd, even, or none. Default setting none. (RFI) Stop Bits Complies with EN61000-4-3 Level 2 and One with parity, one or two with no parity. EN50082-1 (3V/M, 80 to 1000MHz AM Default setting is two stop bits with no and 900MHz keyed). parity. Electrical Fast Transient Immunity Watchdog Timer (Hardware) (EFT) A hardware watchdog timer is built into EN61000-4-4 Level 1 and EN50082-1 each module to perform a reset if the (0.5KV power, signal lines). microcontroller fails to return from an Electrostatic Discharge (ESD) operation in a timely manner or locks Immunity up. EN61000-4-2 Level 3 and EN50082-1 (8KV/4KV air/direct discharge). Surge Immunity EN61000-4-5 (0.5KV) and EN50082-1. Radiated Emissions Meets EN50081-1 for Class B equipment. Approvals CE marked. UL listed for US and Canada. Class I; Division 2; Groups A, B, C, D. Enclosure Self-extinguishing NYLON type 6.6 polyamide thermoplastic UL94 V-2, color beige; general purpose NEMA Type 1 enclosure. Connectors (Removable Terminal Blocks) Wire Range: AWG #12-24, stranded or solid copper. Dimensions 1.05W x 4.68H x 4.35D inches 26.7W x 118.9H x 110.5D mm. DIN Rail Mounting DIN rail mount, Type EN50022; T rail (35mm). Shipping Weight 1 pound (0.45 Kg) packed. Ordering Information Description Order Number 4-channel current output module DI-917MB 4-channel voltage output module DI-918MB DI-900MB Configuration Kit (includes Configuration Software, RS-232/485 non-isolated converter, and to 3-wire cable, 8ft.) 100969 RS-232 to USB Adaptor 100970 19" rack mount kit with DIN rail 100971 RS-232 cable for 100974 and 100957 products (DB-9 to three-wire) 100976 Isolated Network Repeater, 115 VAC Power 100977 Isolated Network Repeater, 230 VAC Power 100978 115V AC Power Cord for 100977 and 100978 products 100979 50W universal power supply; 24V DC @ 2.1A (50W) output; 85-264V AC or 105-370V DC input 100980 Data Acquisition Product Links (click on text to jump to page) Data Acquisition Data Logger Chart Recorder Thermocouple Oscilloscope DATAQ Instruments, Inc. 241 Springside Drive Akron, Ohio 44333 Ph: 330-668-1444 www.dataq.com