Configuring POS interfaces

Similar documents
Table of Contents 1 E-CPOS Interface Configuration 1-1

HP 6600/HSR6600 Routers

HP A6600 Routers Interface. Configuration Guide. Abstract

NOTE: The S9500E switch series supports HDLC encapsulation only on POS interfaces. Enabling HDLC encapsulation on an interface

1-Port OC-48/STM-16 Packet over SONET Line Card Configuration

Ethernet interface configuration commands

CPOS Interface. Synchronous digital hierarchy (SDH), defined by CCITT (today s ITU-T), uses a SONET rate subset.

H3C SR6600/SR6600-X Routers

Introduction Metro Area Optical Networks Components of a MAN Metro Service POP Core MAN Services Access Services Metro Optical Services Service POP

Configuring POS. POS on the ML-Series Card. ML-Series SONET and SDH Circuit Sizes CHAPTER

Configuring the Channelized OC-12/T3 SONET/SDH Optical Services Modules

Multichannel STM-1 Port Adapter for the Cisco 7500 Series Router

Table of Contents. Chapter 1 Port Configuration Overview

Contents. Configuring GRE 1

POS on ONS Ethernet Cards

INDEX. ATM overview. bert pattern command HC-402, HC-404 buckets archive command HC-169 bundle command HC-543 Bundle-Ether command HC-215 HC-58 HC-13

Configuring Frame Relay

Troubleshooting Physical Layer Alarms on SONET and SDH Links

HP MSR Router Series. Interface Configuration Guide(V7) Part number: a Software version: CMW710-R0106 Document version: 6PW

POS on ONS Ethernet Cards

Ethernet interface configuration commands

CE Ethernet Operation

Table of Contents 1 Ethernet Interface Configuration Commands 1-1

Configuring Clear Channel SONET Controllers on the Cisco ASR 9000 Series Router

SONET/SDH. By Iqtidar Ali

HP MSR Router Series. Interface Configuration Guide(V7) Part number: b Software version: CMW710-R0304 Document version: 6PW

Ethernet interface commands

HP MSR Router Series Interface

PA-POS-2OC3 Overview. The Cisco 7206 VXR router can be used as a router shelf in a Cisco AS5800 universal access server.

Configuring SDH on 1-Port OC-192/STM-64 or 8-Port OC-3/12/48/STM-1/-4/-16 Module

Configuring Serial Interfaces on the Cisco ASR 9000 Series Router

Table of Contents Chapter 1 Tunneling Configuration

Differences Between SONET and SDH Framing in Optical Networks

Network Topologies & Error Performance Monitoring in SDH Technology

Configuring LAN/WAN-PHY Controllers on Cisco IOS XR Software

Single-router APS for the Cisco Series Router

WAN technology which are to be discussed:

Ethernet Interface Configuration Commands

Configuration of Synchronous Protocols

Configuring SDH on 1-Port OC192/STM-64 or 8-Port OC3/12/48/STM-1/-4/-16 Module

Request for Comments: June MAPOS - Multiple Access Protocol over SONET/SDH Version 1

Configuring Automatic Protection Switching

Ethernet Interface Configuration Commands

Configuring the 1-Port Channelized OC-3/STM-1 SPA

Direct Link Networks. Framing. Lecture - Encoding & Framing 1. Problems. Areas for Discussion

HP 6125G & 6125G/XG Blade Switches

Network Configuration Example

Cisco 2-Port, 4-Port, and 8-Port OC-12c/STM-4 Packet over SONET Shared Port Adapters

Cisco 2-Port and 4-Port OC-3c/STM-1c POS Shared Port Adapters

Configuring Synchronous Ethernet ESMC and SSM

SONET. By Sadhish Prabhu. Unit II

Configuring MPLS L2VPN

Configuring the 2-Port and 4-Port Clear Channel T3/E3 SPAs

Configuring MPLS L2VPN

HPE FlexFabric 7900 Switch Series

Configuring T1/E1 Interfaces

Table of Contents 1 IPv6 Basics Configuration 1-1

Configuring T1/E1 Interfaces

Synchronous Ethernet (SyncE) ESMC and SSM

SONET/SDH VCAT SONET VCAT

Configuring the OC3 POS Line Card

Loopback detection configuration commands

HP Routing Switch Series

Interface Configuration

Operation Manual IPv6 H3C S3610&S5510 Series Ethernet Switches Table of Contents. Table of Contents

Command Reference APPENDIX

Table of Contents 1 IPv6 Configuration IPv6 Application Configuration 2-1

Table of Contents 1 IPv6 Configuration IPv6 Application Configuration 2-1

BROADBAND AND HIGH SPEED NETWORKS

Configuring T1/E1 Interfaces

Configuring MSDP. Overview. How MSDP operates. MSDP peers

Synchronous Optical Networks SONET. Computer Networks: SONET

IP over. Mario Baldi. Politecnico di Torino. (Technical University of Turin) IPinterconnection - 1 Copyright: si veda nota a pag.

INDEX AR HR IR MCR MNR MPR NFR QR RR SMR SR VPR

Configuring the SM-1-STM1

RADview-EMS/TDM. Element Management System for TDM Applications Optimux RAD Data Communications Publication 03/06

Table of Contents 1 IPv6 Configuration IPv6 Application Configuration 2-1

Fractional DS3. Version: 400. Copyright ImageStream Internet Solutions, Inc., All rights Reserved.

PA-POS-1OC3 Overview

Lab Troubleshooting WAN Connectivity

LIM Configuration Menu

Contents. Configuring MSDP 1

486 bit stuffing, eliminating, SONET

HP A3100 v2 Switch Series

Overview. Port Adapter Overview CHAPTER

Operation Manual ARP H3C S5500-SI Series Ethernet Switches. Table of Contents

Configuring the OC12 POS Line Card

R 155. ZyFLEX. A Fiber Optical Multiplexer For Future-Proof Telecom Solutions.

Synchronous Optical Networks (SONET) Advanced Computer Networks

Configuring VPLS. VPLS overview. Operation of VPLS. Basic VPLS concepts

Network Working Group. Category: Standards Track Nortel Networks April 2002

HP MSR Router Series. Layer 2 - WAN Access Configuration Guide(V7)

HP 5120 SI Switch Series

E1-E2 (EB) Chapter 4 MSPP

Command Reference for the ML-Series Card

Using Serial Ports to Connect to ATM with DXI Encapsulation

Operation Manual BFD-GR H3C S3610&S5510 Series Ethernet Switches. Table of Contents

frame-relay lapf n201

Routing. Point to point protocol (PPP) ETSF05 Internet Protocols Kaan Bür 1

H3C S9500E Routing Switch Series POS Interface Card Datasheet

Transcription:

Contents Configuring POS interfaces 1 Overview 1 SONET 1 SDH 1 POS 1 Configuration procedure 1 Displaying and maintaining POS interfaces 3 POS interface configuration examples 4 Directly connecting switches through POS interfaces 4 Connecting switches through POS interfaces across frame relay 4 Troubleshooting POS interfaces 6 i

Configuring POS interfaces Overview SONET SDH POS Synchronous Optical Network (SONET), a synchronous transmission system defined by the ANSI, is an international standard transmission protocol that adopts optical transmission. ITU-T Synchronous Digital Hierarchy (SDH) uses a SONET rate subset. SDH adopts synchronous multiplexing and allows for flexible mapping structure. Low-speed tributary signals can be added to or dropped from SDH signals without a large number of multiplexing/demultiplexing devices. This reduces signal attenuation and investment in network devices. Packet over SONET/SDH (POS) is a technology popular on WAN and MAN. It can support packet data such as IP packets. POS maps length-variable packets directly to SONET synchronous payloads and uses the SONET physical layer transmission standard. It offers high-speed, reliable, and point-to-point data connectivity. The POS interfaces on your switch support PPP, frame relay, and HDLC at the data link layer and IP at the network layer. Depending on the subcards of a POS interface, its transmission rate can be STM-1, STM-4, and STM-16, each four times the immediate lower level. Configuration procedure Before configuring the link layer and network layer protocols on a POS interface, you must configure its physical parameter settings. To configure a POS interface: Step Command Remarks 1. Enter system view. system-view N/A 2. Enter POS interface view. interface pos interface-number N/A 3. Set the interface description. description text By default, the description of a POS interface is interface name Interface, for example, POS2/1/1 Interface. 1

Step Command Remarks 4. Set the clock mode. clock { master slave } 5. Set the CRC length. crc { 16 32 } The default is slave. The default is 32 bits. 6. Set the loopback mode. loopback { local remote } Loopback is disabled by default. Enable it only when special test is desired. 7. Configure the overhead bytes. flag c2 flag-value flag { j0 j1 } { sdh sonet } flag-value The default is hexadecimal 16 for C2. By default, SDH framing applies. In SDH framing, the defaults are null for both J0 and J1. 8. Set the framing format. frame-format { sdh sonet } 9. Configure scrambling. scramble The default is SDH. Enabled by default. 10. Specify the link layer protocol. link-protocol { ppp fr [ nonstandard ietf ] hdlc } The default is PPP. 11. Set the interface MTU. mtu size The interface MTU (in bytes) is in the range of 64 to 10240 and defaults to 1500. The maximum MTU you can configure for a POS interface is 10240 bytes, but the one that actually takes effect is 9216 bytes. 12. Set the signal degrade (SD) or signal fail (SF) alarm threshold for the interface. 13. Set the protective action for alarms on the interface. 14. Set the rate of the POS interface. 15. Set the statistics polling interval of the POS interface. threshold { sd sf } value alarm-detect { rdi sd sf } action link-down speed speed-value flow-interval interval The SD alarm threshold defaults to 10e-6. The SF alarm threshold defaults to 10e-4. By default, no protective action for alarms is set on the interface. By default, the rate of a POS interface on a LSR1DTCP8L1 subcard is 155 Mbps. 300 seconds by default. 2

Step Command Remarks 16. Set the physical state change suppression interval. link-delay msec milliseconds 1000 milliseconds by default. 17. Restore the default settings. default 18. Shut down the POS interface. shutdown By default, a POS interface is up. When you modify parameters on a POS interface, execute the shutdown command, and then the undo shutdown command to make your modifications take effect. NOTE: The POS interface can operate in master clock mode only when the SRPU (or the main control board) is installed with a clock daughter card. IPv6CP of PPP cannot get the peer IPv6 address through auto negotiation. Therefore, when a POS interface is used for IPv6 hardware forwarding, you need to configure static routes or routing protocols on it. Displaying and maintaining POS interfaces Task Command Remarks Display information about one or all POS interfaces. Display IP-related configurations and statistics for one or all POS interfaces. Display IPv6-related configurations and statistics for one or all POS interfaces. Clear the statistics on POS interfaces. display interface [ pos ] [ brief [ down ] ] [ { begin exclude include } regular-expression ] display interface [ pos [ interface-number ] ] [ brief [ description ] ] [ { begin exclude include } regular-expression ] display ip interface pos [ interface-number ] [ { begin exclude include } regular-expression ] display ipv6 interface pos [ interface-number verbose ] [ { begin exclude include } regular-expression ] reset counters interface [ pos [ interface-number ] ] Available in any view. Available in any view. Available in any view. Available in user view. 3

POS interface configuration examples Directly connecting switches through POS interfaces Network requirements As shown in Figure 1, Use a pair of optical fibers (for receiving and sending data) to connect the POS interfaces on Switch A and Switch B. Enable PPP encapsulation on the interfaces. Figure 1 Network diagram Configuration procedure 1. Configure Switch A: # Configure interface POS 2/1/1, setting its physical parameters to defaults. <SwitchA> system-view [SwitchA] interface Pos 2/1/1 [SwitchA-Pos2/1/1] ip address 10.110.1.10 255.255.255.0 [SwitchA-Pos2/1/1] link-protocol ppp [SwitchA-Pos2/1/1] mtu 1500 [SwitchA-Pos2/1/1] shutdown [SwitchA-Pos2/1/1] undo shutdown 2. Configure Switch B: # Configure interface POS 2/1/1. <SwitchB> system-view [SwitchB] interface Pos 2/1/1 # Set the clock mode to master and other physical parameters to defaults. [SwitchB-Pos2/1/1] clock master [SwitchB-Pos2/1/1] ip address 10.110.1.11 255.255.255.0 [SwitchB-Pos2/1/1] link-protocol ppp [SwitchB-Pos2/1/1] mtu 1500 [SwitchB-Pos2/1/1] shutdown [SwitchB-Pos2/1/1] undo shutdown You can check the connectivity between the POS interfaces by using the display interface pos command and test network connectivity by using the ping command. Connecting switches through POS interfaces across frame relay Network requirements As shown in Figure 2, connect switches to a public frame relay network through POS interfaces. The switches are premise equipment that work as DTE side of frame relay. 4

Switch A uses frame relay sub-interfaces to connect Switch B and Switch C in different network segments. Figure 2 Network diagram Configuration procedure 1. Configure Switch A: # Configure POS interface 3/1/1. <SwitchA> system-view [SwitchA] interface Pos 3/1/1 [SwitchA-Pos3/1/1] clock slave # Configure frame relay encapsulation on the interface. [SwitchA-Pos3/1/1] link-protocol fr [SwitchA-Pos3/1/1] fr interface-type dte [SwitchA-Pos3/1/1] quit # Create sub-interface 1 on the interface. [SwitchA] interface Pos 3/1/1.1 [SwitchA-Pos3/1/1.1] ip address 10.10.10.1 255.255.255.0 [SwitchA-Pos3/1/1.1] fr dlci 50 [SwitchA-Pos3/1/1.1] fr map ip 10.10.10.2 50 [SwitchA-Pos3/1/1.1] mtu 1500 [SwitchA-Pos3/1/1.1] quit # Create sub-interface 2 on the interface. [SwitchA] interface Pos 3/1/1.2 [SwitchA-Pos3/1/1.2] ip address 20.10.10.1 255.255.255.0 [SwitchA-Pos3/1/1.2] fr dlci 60 [SwitchA-Pos3/1/1.2] fr map ip 20.10.10.2 60 [SwitchA-Pos3/1/1.2] mtu 1500 [SwitchA-Pos3/1/1.2] quit 2. Configure Switch B: # Configure interface POS 3/1/1. [SwitchB] interface Pos 3/1/1 [SwitchB-Pos3/1/1] clock slave # Configure frame relay encapsulation on the interface. [SwitchB-Pos3/1/1] link-protocol fr [SwitchB-Pos3/1/1] fr interface-type dte [SwitchB-Pos3/1/1] ip address 10.10.10.2 255.255.255.0 5

[SwitchB-Pos3/1/1] fr dlci 70 [SwitchB-Pos3/1/1] fr map ip 10.10.10.1 70 [SwitchB-Pos3/1/1] mtu 1500 3. Configure Switch C in the same way Switch B is configured. Verifying the configuration Check interface connectivity with the display interface pos command and test network connectivity with the ping command. Troubleshooting POS interfaces Symptom 1 Solution Symptom 2 Solution Symptom 3 Solution The physical state of a POS interface is down. Check that the transmitting and receiving optical fibers are correctly connected to the POS interface. If you connect the two ends of an optical fiber to the transmitting end and the receiving end of the same POS interface, you can see the message "loopback detected" on the screen when executing the display interface command even if you have not enabled loopback. If the two switches are directly connected (back to back), check that the POS interfaces use different clock modes. The physical layer is up but the link is down. Check that: The settings of clock, scrambling and other physical parameters are consistent on the two connected POS interfaces. The same link layer protocol is configured on two sides. Both ends are assigned IP addresses. A great amount of IP packets are dropped. Check that: The correct clock mode is configured on the POS interface. If not, enormous amount of CRC errors will be generated. The Maximum transmission unit (MTU) configuration is matched. 6