R7D-RR8 BEFORE USE... POINTS OF CAUTION. INSTRUCTION MANUAL REMOTE CONTROL RELAY CONTROL MODULE, 8 points MODEL. (DeviceNet)

Similar documents
BEFORE USE... POINTS OF CAUTION. INSTRUCTION MANUAL PNP TRANSISTOR OUTPUT MODULE, 16 points (MECHATROLINK-I / -II, short circuit protection)

R6-NC1 BEFORE USE... POINTS OF CAUTION. INSTRUCTION MANUAL CC-Link INTERFACE MODULE MODEL. (CC-Link Ver.1.10; for 16-point analog signals)

R3-GE1 BEFORE USE... INSTALLATION POINTS OF CAUTION INSTRUCTION MANUAL ETHERNET INTERFACE MODULE MODEL. (Modbus/TCP)

R3-NL2 INSTALLATION BEFORE USE... POINTS OF CAUTION INSTRUCTION MANUAL LONWORKS INTERFACE MODULE MODEL. (I/O 56 points)

R3-NL1 LONWORKS INTERFACE MODULE BEFORE USE... INSTALLATION POINTS OF CAUTION INSTRUCTION MANUAL. R3-nL1 MODEL

R1M-GH BEFORE USE... POINTS OF CAUTION INSTRUCTION MANUAL PC RECORDER MODEL. (thermocouple or DC input, 16 points)

R1M-GH BEFORE USE... POINTS OF CAUTION INSTRUCTION MANUAL PC RECORDER MODEL. (thermocouple or DC input, 16 points)

NPN / PNP DISCRETE INPUT & NPN TRANSISTOR OUTPUT MODULE, 16 points each

MODEL: R2K-1 SEN TRONIC AG. R2K Series

DLS-E2 TELEMETERING UNIT BEFORE USE... POINTS OF CAUTION INSTRUCTION MANUAL MODEL. (16 contact inputs & 16 open collector outputs)

R6-NE1 BEFORE USE... POINTS OF CAUTION INSTRUCTION MANUAL ETHERNET INTERFACE MODULE MODEL. (Modbus/TCP, for 32-point analog signals)

PWR. Power Module Slots

NPN/PNP DISCRETE HIGH SPEED INPUT & NPN TRANSISTOR OUTPUT MODULE

CONTENTS 1. BEFORE USE GENERAL DESCRIPTION POINTS OF CAUTION HARDWARE SPECIFICATIONS... 4

MODEL: M5DY SEN TRONIC AG CURRENT LOOP SUPPLY. [2] POWER INPUT AC Power M: V AC (Operational voltage range V, Hz)

R1M-J3 BEFORE USE... POINTS OF CAUTION INSTRUCTION MANUAL RTD & POTENTIOMETER INPUT MODULE MODEL. (8 points)

MODEL: R1M-P4. PC Recorders R1M Series. SPECIFICATIONS OF OPTION: Q COATING (For the detail, refer to M-System's web site.)

MODEL: R1M-A1. PC Recorders R1M Series. SPECIFICATIONS OF OPTION: Q COATING (For the detail, refer to M-System's web site.)

MODEL: R1M-D1. PC Recorders R1M Series. SPECIFICATIONS OF OPTION: Q COATING (For the detail, refer to M-System's web site.)

USER S MANUAL. FX2N-64DNET DeviceNet Interface Block

INSTALLATION MANUAL For authorized service personnel only.

INSTRUCTION MANUAL 2-WIRE UNIVERSAL TEMPERATURE TRANSMITTER

R: Red Y: Amber G: Green B: Blue W: White. R: Red Y: Amber G: Green B: Blue W: White. R: Red Y: Amber G: Green B: Blue W: White.

ELC-CODNETM. Effective December Users Manual

EX-RC1 Remote I/O Adapter

MODEL: R1M-GH. PC Recorders R1M Series

Table of Contents 1 ABOUT THIS DOCUMENT GENERAL COPYRIGHT INFORMATION TERMS ABOUT THE GATEWAY PRODUCT FUNCTIO

Varispeed SERIES OPTION CARD DeviceNet COMMUNICATION INTERFACE CARD USER'S MANUAL Model: SI-N1

INSTRUCTION SHEET. Eaton Logic Controller DeviceNet Distributed I/O Adapter Module. [Applicable Distributed I/O Adapter Module] ELC-CADNET

MPCR Series DeviceNet Technical Manual TDMPCRDNTM2-0EN 01/08 Subject to change without notice

NU-DN1. User s Manual. DeviceNet Compatible Network Unit

Appendix 3 Using NS-AL002 Converters

MODEL: R3-NL1. RELATED PRODUCTS XIF File (Device Interface File) XIF file is used to define a LonWorks device when programmed on LonMaker.

Operation Manual. Fieldbus system EX510-GDN1. DeviceNet Compatible GW unit

MODEL: R3-NL2. RELATED PRODUCTS XIF File (Device Interface File) XIF file is used to define a LonWorks device when programmed on LonMaker.

EX-RC1 Remote I/O Adapter

R3-NE1 ETHERNET INTERFACE MODULE MODEL. Remote I/O R3 Series. (Modbus/TCP)

PROFIBUS DP/CAN Gateway PCA-100. User Manual

MODEL: R3-NE1. Remote I/O R3 Series. ETHERNET INTERFACE MODULE (Modbus/TCP) 27.5 (1.08)

MODEL: R3-NFL1. SPECIFICATIONS OF OPTION: Q COATING (For the detail, refer to M-System's web site.) Remote I/O R3 Series

MICRO-SCREEN DIN Controllers with DeviceNet Trip Output

1.5 axis motion controller

Doc. No.: EX**-OMC0024. Instruction Manual. SI Unit / DI Unit EX240-SDN2 EX240-IE1 SMC CORPORATION

HITACHI. EH-150 series PLC EH-RTD8 Resistance Temperature Detective input module Instruction manual. Safety precautions

EX-RC1 Remote I/O Adapter

MPCR Series DeviceNet Technical Manual

MODEL CIO-EN MODBUS/TCP, MODBUS/RTU I/O MODULE

IO-DI8-TO8, IO-DI8-TO8-L I/O Expansion Modules 8 Inputs, 8 Outputs

Component identification

Communications & Networking

R7X CONFIGURATOR. (model: R7CON) Users Manual , Minamitsumori, Nishinari-ku, Osaka JAPAN Tel: Fax:

MODEL: WL40EW2F. Wireless I/O WL40F Series

Terminal block 2 A 5 X 3. Specification

EX120/121/122 Series Some protocols are not CE-compliant.

OPERATION MANUAL E/P REGULATOR MODEL NAME. Series. For DeviceNet TM CONTENTS. Contents. Safety Instructions. Precautions for Handling P3-4

Manual and Protocol Description

IO-PT4. Component identification. User safety and equipment protection guidelines. Unitronics Industrial Automation Systems 1

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

FACTORY AUTOMATION MANUAL CBX500 HOST INTERFACE MODULES

Power Input Assignment Power1 12VDC DC Jack VDC Power2 - Power Ground

Preface. is the registered trademark of ODVA (Open DeviceNet Vender. Association). *1 Excluding the GP-3200 series.

MODEL: 40DN. Digital Panel Meters 40 Series

Communicative controller for VAV systems

GE FANUC Parts 1. DeviceNet Network Master/Slave August 2002 GFK-1539A. Quick Start Guide. Product Description. Specifications. Preinstallation Check

Installation Instructions for DeviceNet E50 Limit Switches

High Speed Remote I/O Module

RTD-NET Installation Instructions

G3 Series PROFIBUS DP Technical Manual

MGate 5111 Quick Installation Guide

01348(N or G) MH** -- Material Handling (N or G) MH** -- Material Handling

IO-DI8-TO8 I/O Expansion Module 8 Inputs, 8 Outputs

Diagnostics (Logical) Diagnostics (Physical)

CJ-series DeviceNet Connection Guide OMRON Corporation 3G3RX-V1 Series Inverter

AUDIO AND VIDEO DOOR ENTRY SYSTEM WITH NEXA CODED PANEL

Modbus Digital Remote I/O. ARM Series. Modbus Sensor Connector Type Digital Remote I/O. Features. User Manual For Communication. Ordering Information

IFC-FDC-PRO PROFIBUS to Daisy Chain Fiber Converter. IFC-Serial-PRO PROFIBUS to Fiber Converter. Industrial Serial Fiber Converter

R1M-GH THERMOCOUPLE & DC INPUT MODULE MODEL. Remote I/O R1M Series. (16 points)

2002 Series DeviceNet Technical Manual

IO-DI8-RO8, IO-DI8-RO8-L I/O Expansion Modules 8 Inputs, 8 Outputs

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

Industrial 3-Port Fast Ethernet Media Converter Switches

VLT 5000 DeviceNet and Allen Bradley Control logix 5550

DN120 DeviceNet Gateway User Manual

DeviceNet Master (Scanner) HE800DNT450 / HE-DNT450* DeviceNet Communications * HE- denotes plastic case.

MODEL: M1EXV. OUTPUT Field-selectable DC Output Current output: 0-20 ma DC Voltage output: V DC Voltage output: V DC

Diagnostics (Physical)

G3 Series DeviceNet TM Technical Manual

XPSMF35. Product data sheet Characteristics. Preventa safety PLC compact - Profibus DP protocol. Main. Complementary. Safety module name

FC 300 DeviceNet and Allen Bradley Control logix 5550

MODEL: GR8-EM. Communication Adaptor GR8 Series

WARNING. KMC BACnet Module Kits IMPORTANT! CONTROLS KITS AND ACCESSORIES

IO-AO6X I/O Expansion Module 6 Isolated Analog Outputs

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

DeviceNet Interface Card "OPC-F1-DEV"

Powered Roller Controller for DeviceNet

PLC Racks IC697CHS782/783

Communication Controller CC-Link/CPL Converter CMC10A

AD-8923-BCD. Remote Controller (BCD) INSTRUCTION MANUAL 1WMPD

KSD-800 Series. Installation Guide. Industrial 8-Port Fast Ethernet Switches with Fiber Connectivity DOC A -1-

KNX is a European Standard Protocol used for household and industrial Buliding Management System (BMS).

Transcription:

INSTRUCTION MANUAL REMOTE CONTROL RELAY CONTROL MODULE, points (DeviceNet) MODEL BEFORE USE... Thank you for choosing M-System. Before use, please check contents of the package you received as outlined below. If you have any problems or questions with the product, please contact M-System s Sales Office or representatives. PACKAGE INCLUDES: Remote control relay control module...() MODEL NO. Confirm Model No. marking on the product to be exactly what you ordered. INSTRUCTION MANUAL This manual describes necessary points of caution when you use this product, including installation, connection and basic maintenance procedures. EDS FILE EDS files are downloadable at M-System s web site: http:// www.m-system.co.jp POINTS OF CAUTION GENERAL PRECAUTIONS Before you remove the unit or mount it, turn off the power supply and output signal for safety. DO NOT set the switches on the module while the power is supplied. The switches are used only for maintenance without the power. ENVIRONMENT Indoor use. When heavy dust or metal particles are present in the air, install the unit inside proper housing with sufficient ventilation. Do not install the unit where it is subjected to continuous vibration. Do not subject the unit to physical impact. Environmental temperature must be within - to + C ( to F) with relative humidity within to % RH in order to ensure adequate life span and operation. WIRING Do not install cables close to noise sources (relay drive cable, high frequency line, etc.). Do not bind these cables together with those in which noises are present. Do not install them in the same duct. AND... The unit is designed to function as soon as power is supplied, however, a warm up for minutes is required for satisfying complete performance described in the data sheet. EM--T Rev. P. /

COMPONENT IDENTIFICATION (A) MS NS X X NODE ADD. (G) (B) (C) (D) (E) (F) B.RATE CNFG. (A) Status Indicator LED (B) Node Address Setting Rotary SW (C) Baud Rate Setting Rotary SW (D) Operating Mode Setting DIP SW (SW) (E) PC Configurator Jack (F) I/O Status Indicator LED (G) DeviceNet, Power Supply Terminals (H) Output Terminals STATUS INDICATOR LED (H) A B CDE F ID STATE TO INDICATE MS Green Operating in a normal condition Blinking Green Standby (needs commissioning) Red Critical failure Blinking Red Minor failure OFF No power supplied NS Green Link on-line and connections in the established state Blinking Green Link on-line but no connections in the established state Red Critical link failure Blinking Red Minor link failure OFF No power supplied I / O STATUS INDICATOR LED Output and feedback input status are indicated with LED. ON : LED ON OFF : LED OFF NODE ADDRESS Node Address is selected between and in decimal. The left switch determines the tenth place digit, while the right switch does the ones place digit of the address. Factory setting : Node Address Setting (x) OPERATING MODE (*) Factory setting Extension (SW-, -) SW- SW- EXTENSION OFF OFF No extension (*) ON OFF Discrete input, or points OFF ON Discrete output, or points Output Data Length: (SW-) SW- OUTPUT DATA LENGTH OFF bit (*) ON bit Note: Be sure to set unused SW- through - to OFF. DeviceNet TERMINAL ASSIGNMENT NO. ID FUNCTION, NOTES V+ Network power supply + CAN_H Network data High Drain Shield CAN_L Network data Low V Network power supply OUTPUT TERMINAL ASSIGNMENT NC NC C Y C Y C Y C Y C Y C Y C Y C Y NO. ID FUNCTION NO. ID FUNCTION NC No connection NC No connection C Common Y Output C Common Y Output C Common Y Output C Common Y Output C Common Y Output C Common Y Output C Common Y Output C Common Y Output EXTENSION MODULE Combinations with all extension modules are selectable. BAUD RATE Node Address Setting (x) Baud Rate is selected with the rotary switch. : kbps (factory setting) : kbps : kbps thr. : Auto-tracking Baud Rate Setting The RD communicates in the baud rate setting detected at the startup with the switch set to the positions ( kbps), ( kbps) or ( kbps). For the settings through, it analyzes the PLC s network to determine the baud rate on the network. EM--T Rev. P. /

PC CONFIGURATOR With configurator software, settings shown below are available. Refer to the software manual of RCON for detailed operation. INTERFACE MODULE SETTING PARAMETER AVAILABLE RANGE DEFAULT SETTING Communication Timeout.. (sec.). (sec.) Status Data ON: Disable OFF: Enable OFF: Enable Serial ID English one-byte characters within characters EXTENSION MODULE SETTING PARAMETER AVAILABLE RANGE DEFAULT SETTING Output Hold/Clear Output Hold Output Hold Output Clear TERMINAL CONNECTIONS Connect the unit as in the diagram below. EXTERNAL DIMENSIONS unit: mm (inch) (.) (.) (.) (.). (.) DIN RAIL mm wide (.) (.) TERMINAL BLOCK for DeviceNet, POWER (.). (.) (.) [ (.)] M SCREW TERMINALS for OUTPUT EM--T Rev. P. /

CONNECTION DIAGRAM V+ CAN_H Drain CAN_L V Y C Y Output Connection Example Y C blue white Remote Control Transformer C Y red blue Remote Control Relay C Y C Y C red blue Remote Control Relay Y C EXTENSION CONNECTOR Y C Y C Y C EM--T Rev. P. /

INPUT OUTPUT DATA BIT & DATA ALLOCATION Output data length can be set with the front DIP switch. Input data length is regardless of output data length, feedback inputs to are assigned to bit to. Input ON:, Input OFF: OUTPUT DATA BIT: BITS (SW-: OFF) When output data bit is bits, set each output with bits. The table below shows data allocation. BIT SETTING OPERATION, No operation,, Output ON, Output OFF, Output RESET, No operation,, Output ON, Output OFF, Output RESET, No operation,, Output ON, Output OFF, Output RESET, No operation,, Output ON, Output OFF, Output RESET, No operation,, Output ON, Output OFF, Output RESET, No operation,, Output ON, Output OFF, Output RESET, No operation,, Output ON, Output OFF, Output RESET, No operation,, Output ON, Output OFF, Output RESET By setting with bits, the module operates as shown above. ON or OFF can be set consecutively. To output ON twice successively, set ON (, ), RESET (, ), and then set ON (, ) again. OUTPUT DATA BIT: BITS (SW-: ON) When output data bit is bits, set each output with bit. The table below shows data allocation. BIT SETTING OPERATION Output OFF Output ON Output OFF Output ON Output OFF Output ON Output OFF Output ON Output OFF Output ON Output OFF Output ON Output OFF Output ON Output OFF Output ON ON (or OFF) cannot be set consecutively, because when each bit is, ON is set and when each bit is, OFF is set. DATA ALLOCATION Begin address is determined by the RD s node address and the master setting. Example. + RD-EA, with Status Output Data Input Data Begin + Begin + + + RD-EA Status Example. + RD-ECx, with Status Output Data Input Data Begin + Begin + + Status + RD-ECx EM--T Rev. P. /

I/O DATA DESCRIPTIONS Output Data Feedback input Feedback input Input Data (output data length: bit) Output Output Input Data (output data length: bit) Output : ON Output : OFF Output : ON Output : OFF Output : ON Output : OFF Output : ON Output : OFF Output : ON Output : OFF Output : ON Output : OFF Output : ON Output : OFF Output : ON Output : OFF EM--T Rev. P. /

STATUS Bit to : Remote control relay control module shows at the same address. Bit to : Shows the power supply status. Remains Remains Remains Remains Remains Remains Remains Remains Network power supply Extension module external power supply : : : Power supply : Normal : Error TRANSMISSION DATA DESCRIPTIONS BASIC MODULE Transmitted data (word) depends upon the modules types. OUTPUT DATA* INPUT DATA* MODEL (RD to Master) (Master to RD) EXTENSION MODULE Transmitted data (word) for the extension module is added. MODEL OUTPUT DATA* INPUT DATA* (RD to Master) (Master to RD) RD-EAx RD-ECx STATUS Status signal can be included in the transmission data when the setting is enabled using the PC Configurator software (model: RCON). For details, refer to STATUS in I/O DATA DESCRIPTIONS. STATUS OUTPUT DATA* INPUT DATA* (RD to Master) (Master to RD) Enabled Disabled *. Output Data means those sent to the master. *. Input Data means those received from the master. WIRING INSTRUCTIONS SCREW TERMINAL (Output) Torque:. N m SOLDERLESS TERMINAL Refer to the drawing below for recommended ring tongue terminal size. Spade tongue type is also applicable. Applicable wire size:. to. mm (AWG to ) Recommended manufacturer: Japan Solderless Terminal MFG. Co., Ltd, Nichifu Co., Ltd (.) max. (.) max mm (inch) EURO TYPE CONNECTOR TERMINAL (DeviceNet) Applicable wire size:.. mm Stripped length: mm EM--T Rev. P. /