Quick Setup Instructions for the Knauer HPLC-System. Quick Setup Instructions for the Knauer HPLC-System For windows XP (using CHANCE vers. 2.

Similar documents
Aqueous GPC Instructions - Detailed

Equipment Overview: Safety:

Operating Manual. High Performance Liquid Chromatograph. Scientific Equipment Center, Prince Of Songkla University

Manual HPLC-4 Alliance-UV

PerkinElmer Series 200 HPLC: Operating Procedure

Sepacore X10 / X50 system Technical data sheet

Introduction to the HPLC ChemStation and Acquisition

Agilent 1100 HPLC ChemStation 1) Turn on all the modules for HPLC system (CapPump G1376A, DAD G1315B) and allow for system to initialize.

UniPoint System Software User s Guide

Guidebook for Installation and Familiarization. HP 1100 Series Combinatorial Chemistry Analysis System

Sciex QTrap Operational Steps for Trained Personnel

ACQUITY UPLC Systems with 2D Technology Capabilities Guide

Agilent GC/MSD Instructions

Standard Operating Procedure for the Beckman PA/CE MDQ Electrophoresis System. Last Modified October 19, 2012

Standard: 2 x 500 ml and 2 x 250 ml (safety) bottles with shut-off valve and 2 µm in-line filter. Built-in 4 channel He degasser.

Using the Chromeleon Summit 2 Tandem Operation Wizard

HITACHI LACHROM ELITE

HEX File Update TCS Technical Bulletin

Standard Operating Procedure for the HPLC-ICP-MS System By Celina Dozier Fall 2017

Isolera. User Manual

Chromeleon-PA Analyzer User s Guide Dionex Corporation

Agilent 1290 Infinity with ISET

EASY-nLC Virtual Instrument for Xcalibur 2.1.x Quick Reference Guide

Waters 600E Multisolvent Delivery System Quick Start Guide

ChromQuest 5.0 Quick Reference Guide

PurityChrom Bio 5 Software Manual V2650

SmartSoft AES Operator s Guide

Soprane II Documentation

Flexar FX-20 LC Pump: Ultimate Performance and Flexibility for UHPLC and HPLC

Hardware Guide. AB SCIEX QTRAP 5500 System

Agilent G2070BA GC ChemStation

Detailed procedures, operation instructions, maintenance, and emergency contact information list is attached.

FROG-4000TM Quick Start Guide

ChromGraph BAS-200B CONTROL

Agilent 1290 Infinity with ISET

Agilent G6855AA MassHunter Personal

Agilent G6854AA MassHunter Personal Pesticide Database Kit Quick Start Guide

9 Maintenance and Repair

Bio Compatibility Kit

Checklist for the SMPS & CPC (5.400 & 5.500) PART 1 Setup of the external Plumbing (for the DMA and the CPC):

Chromeleon software orientation

OpenLAB. CDS EZChrom Edition KNAUER Instrument Control SOFTWARE

A. About this Manual

Bent Pins Inside the Sample Chamber

OEM applications. Our engineers welcome your ideas and are pleased to help realize your projects. IDEX Complete Fluidic Solutions

Flexar FX-20 LC Pump: Ultimate Performance and Flexibility for UHPLC and HPLC

Agilent 1200 Infinity II Series Refractive Index Detector

Montgomery County Community College Document Number: DP DeKalb Pike Revision Number: 2. Page 1 of 9 SOP: BioLogic LP Chromatography System

ANALYTICAL SYSTEMS. L3320 Autosampler with excellent accuracy and linearity. System configuration examples

SepacoreControl Software data sheet

Steps for LCMS-8040 Triple Quadrupole

PLTconnect. PLT unit software. Operating Manual

9 Maintenance. Agilent Technologies. This chapter describes the maintenance of the module. InfinityLab LC Series Diode Array Detectors User Manual

Agilent 1290 Infinity 2D-LC Solution

Agilent 7890 Series Gas Chromatograph

Accessories for

EASY-nLC Series User Guide for the Xcalibur Data System (Xcalibur version 2.1 or later)

Precision Instruments for Research and Industry. J-KEM Scientific Syringe Pump

Installation Note for Isocratic-to- Quaternary Pump Upgrade Kit G1352A

Optimizing System Dispersion on the Agilent 1290 Infinity II LC

Upgrading the UltiMate 3000 RSLCnano System with ProFlow Technology

Agilent Intuvo 9000 Gas Chromatograph

3 Starting the chiral HPLC and logging into LC Real Time Analysis.

REFILLABLE CARTRIDGE SYSTEM FOR THE EPSON STYLUS PRO 7800 & 9800

4 Instrument Instructions for CE

Agilent MassHunter Workstation Software 7200 Accurate-Mass Quadrupole Time of Flight GC/MS

Toriemon FGV-X and FGV-HX INSTRUCTION MANUAL

Waters Alliance GPC 2000 Series System

SHIMADZU LC-10/20 SYSTEM

Ink Cartridge and Print Head Maintenance Manual

Agilent Max-Light Cartridge Cell Information for G4212A/B DAD and G7117A/B DAD

Agilent G1978B Multimode Source for 6410 Triple Quad LC/MS

C h r o m S t a r 7. M a n u a l

Supporting Information

Samples Preparing the GC to run samples Running samples - Manual Injection Running samples - GC ALS or Valve Injection

Configuring and optimizing an IC-MS system using a compact IC and a single quadrupole mass spectrometer

Agilent Instrument Control Framework A for Agilent LC/CE and GC Instruments in Non-Agilent Chromatography Data Systems Release Notes

Canto II Operation Protocol

The port replicator may have features that are not supported by your computer.

Operation of the Kratos Profile Mass Spectrometers Table of Contents

Agilent G1978A Multimode Source for 6300 Series Ion Trap LC/MS

Standard Operating Procedure for the Horiba FluroMax-4

MICROFLUIDIC EOF KIT 9015

Quick Start. Model 203 Single Channel PeakSimple Data System. STEP 2 (optional) STEP 4 STEP 5 STEP 1. STEP 3 (optional)

ProJet 3600 ProJet 35X0

Getting Started With the CCPilot VI and QuiC

USING ABSOLUTE BLACK INKS FOR MAKING SCREEN POSITIVES ON THE EPSON STYLUS PRO 7700, 7890, 7900, 9700, 9890, & 9900

1100/1200 Series Injector Programming

Agilent G1978B Multimode Source for 6100 Series Single Quad LC/MS

Customer Information. Service Engineer s Responsibilities. Additional Instruction Notes. System Information. Agilent Technologies

SymBiot I Sample Workstation

Pre-installation guide for analytical systems User manual HPLC

For additional information, see these documents on the Breeze 2 software DVD:

Agilent SD-1 Purification Solution

Setting up the PC ready for BESA 11

User Guide - HyTronic Faucet S. Clearwater Dr. Schachenstrasee 77 (800) (0) Commander

Original Instructions January Manual. Software

1320 Electronics LLC USB-ALDL Cable User s Guide Electronics LLC. User s Guide for: USB-ALDL Cable

OTC 3210 Update Instructions

MAZDA Application Purchase and Installation Guide

Transcription:

For windows XP (using CHANCE vers. 2.0) Compiled by P. Madl Vers. 1.0 June 2011 1 / 9

1. Hardware Setup: Result 1.1. Attach RS 232 interface cable (designated as PC) to COM-port-1 of the laptop. 1.2. connect the other end of the RS232 cable with the peripheral device (Knauer K-200 detector). 1.3. boot both laptop and peripheral devices (Knauer pump k-200 & detector k-120 make sure that pump is powered up but not yet working dot-point of the flow-rate indicator shoudl not flashing). 1.4. unplug seal of piston / compression unit to attach syringe filled with cleansing solution (e.g. 70% isoprop. : 30% H2O ). 1.5. flush piston / compression unit with cleansing solution & reattach seal. 1.6. attach solvent flask (e.g. 15% acetonitrile : 0.1% formic acid) to HP-pump. 1.7. use a separate syringe with adapter and hook to outlet of 6- port valve. 1.8. activate pump and suck entrapped air out of the pumping unit until solvent drips according to the flow-rate as indicated on the display of the HP-unit (k-200). 1.9. Repeat procedure with the lever of the 6-port valve switched into the other position. pressure gauge should still be 0. 2 / 9

1.10. once flow is established, stop the pumping cycle. 1.11. attach one end of the connecting capillary to the outlet of the 6-port valve and the other one to the separation column. 1.12. hook outlet of separation column onto detector (k-120). 1.13. re-activate the pump and make sure that solvent is pumped through the column, detector all the way into the receiving waste bin at the end of the flow line. check pressure gauge!. check also for leaks! 1.14. once flow is established, stop the pumping cycle and.. proceed with the next section (SW-setup). 3 / 9

2. Software Setup & Measurement: Result 2.1. boot CHANCE software by double-clicking the ECW-icon.. opens CHANCE s main window 2.2. load measurement method: 2.3. select on of the file tabs: i) when working with an already existing configuration, proceed with step 2.5 (OPEN file) i) if hardware config. needs to be established (NEW file) continue with step 2.4. 2.4. NEW creating a new measurement configuration; click the blank tap and: i) select method (e.g. isocratic system); i) enter the analyst s name; i) define run time (e.g. 000:08:00) i) select data rate (e.g. 2 Hz) i) define flow rate (e.g. 2.0 ml/min) i) confirm with SAVE by i) enter a new measurement method and specify destination directory (e.g. >hardware) 4 / 9

2.4.a. configure peripheral hardware: i) click on the hardware (HARD) icon:. opens pump s set-up window 2.4.b. activate the pump icon (double click pictogram):. opens pump s set-up window In that window, tick the appropriate tag: i) pump head (e.g. 10 ml) i) COM-port (off) 2.4.c. activate the pump icon (double click pictogram): In that window, tick the appropriate tag: i) time constant (e.g. 1 sec) i) COM-port (e.g. COM 1). opens detector s setup window 2.4.d. activate the 6-port icon (double click pictogram):. opens port s set-up window In that window, tick the appropriate tag: i) choose loop volume (e.g. 20 µl) i) select material (e.g. peek) i) select size (e.g. 1/16 ) 5 / 9

2.4.f. close hardware config window by confirming changes with YES: 2.4.g. finalize with SAVE: 2.5. OPEN loading an existing measurement configuration: Ticking open provides the window with the general features: i) select hardware; i) choose the appropriate config.; e.g. 2mL/min @ 240 bar; i) check flow rate at HP-pump if there is a mismatch adjust with the or arrows); i) select data rate (e.g. 2 Hz) i) define flow rate (e.g. 2.0 ml/min) i) confirm with SAVE by entering a new measurement method 2.5.a. start chromatographic run (blank run, w/o analyte): i) activate pump at HP-unit (arrow) - be sure that pump operates at same flow rate as used above; i.e. 2mL/min; i) observe pressure gauge. 6 / 9

i) once operating pressure is reached, click the start icon for the pump and the measurement & i) name scan (i.e. blank-01) and confirm. opens the hold-on window i) observe the detector s display for autozeroing (AO).. system opens timeline and plots the live readout values of the detector (k-120). 2.5.b. start chromatographic run (w/ analyte): i) flush syringe thoroughly with solvent (at least 3 times - dispose runoff into waste bin); i) inject solvent into the loop (since the loop holds e.g. 20 µl, inject at least 60 µl); i) click the start icons and. & i) name scan (i.e. sample-01) and confirm i). once AO appears, turn lever of 6-port valve to route content of 20µL standby-loop onto the chromatographic column. bypassed loaded 2.5.c. finalize measurement by i) deactivating the pump, i) pulling back the lever of the 6- port valve and i) terminating the measurement; & 7 / 9

3. Data Evaluation: 3.1. graphic data evaluation: i) load chromatogram Result i) select appropriate file from the chromatogram-tab i) click the edit-tab i) use the appropriate icons to mark the peaks of interest for further data evaluation 8 / 9

i) use right mouse-click to exit edit mode and i) tab-return to switch to the previous menu. i) activate the peak-report tab 3.2. shutting down software; i) terminate all windows: i) exit main frame by clicking the (CLOSE) function at the top right corner. 9 / 9