User s Guide. POWERVAR Single Phase Power Conditioners

Similar documents
iconverter 2-Module Power Chassis

Installation Instructions for Eaton Surge Protective Device XXCFXXX10-DIN and XXCFXXX10-DIN2

Omnitron Systems Technology, Inc. 1. iconverter. 19-Module Managed Power Chassis User s Manual

The PST-6. Owners Manual 1

PS8 - II. Professional Power Sequencer. User s Manual

PDS8u POWER DISTRIBUTION SYSTEM USER'S MANUAL

XBDM. 1015LV, 1020LV, 1030LV, 1020HV Models USER & INSTALLATION MANUAL BYPASS DISTRIBUTION MODULE

SATA II HDD Canister KISS DA 435 Quick Reference Guide

Surge Protective Devices Installation, Operation and Maintenance Manual. LoadTrack LTL

DCS-E 1kW Series, DLM-E 3kW & 4kW Power Supplies

Power Rack 58. EXT-PS5-8R User Manual.

OPERATING AND SERVICE MANUAL. Universal Interface Device 47

Installation, Testing, and Operating Procedures 30 AMP PORTABLE AND PERMANENT SERIES GFCI SINGLE and MULTIPHASE

Configurable Output Distribution. 120V / 208V / 240V 60Hz. User Manual English

3-4 SAS/SATA II HDD Canister Entry version USER S MANUAL XC-34D1-SA10-0-R. Document number: MAN A

DCM Digital Control Modules

Automated Tuner System Power Distribution Hub

Eaton Innovative TechnologyT XT50/100 surge protective device

Installation and Operation Guide for PD5200 and PD5300 Automatic Transfer Switch

OPERATING AND SERVICE MANUAL. Universal Interface Device 47

Broadband Automatic Disconnect Switch. User Manual

EMS Electrical Management System

Progressive Industries, Inc. EMS Electrical Management System

Proliphix EPA-60 Installation Guide

Xxxxx Xxxxxx Bridge / Strain Gauge Data Logger

User Guide. Control Box. RoscoLED TM.

PCM-7140 Pulsed Current Source Operation Manual

Instructions. RM3000 Rackmount Kit for TDS3000 Series Oscilloscopes

Digital Lighting Systems, Inc. CD400-DMX DMX512 Four Channel Dimmer and Switch module

PMDX-105. I/O Option Riser Board User s Manual. Document Revision: 1.1 Date: 7 September 2004 PCB Revision: PCB-443A

Digital Lighting Systems, Inc. PD216. Two Channel Dimmer and Switch Packs PROTOCOL USER'S MANUAL. PD216-UM Rev. E - 02/03

FNet Repeater Installation & Operator s Instruction Manual

EMS. Electrical Management System. Progressive Industries Incorporated Morrisville, North Carolina

Xxxxx Xxxxxx OM-CP-QUADVOLT. OM-CP-OCTVOLT 8-Channel Low Level DC Voltage Data Logger. 4-Channel Low Level DC Voltage Data Logger INSTRUCTION SHEET

Tornado F-5. Motor Backspin Detect Relay And Probe For F-5 Motor Controller

MAXIMA + Series ROTARY LEVEL CONTROL

RM3100 Rackmount Kit for the AFG3000 and AFG3000C Series Arbitrary Function Generators

CUBE Micro Station User Guide

OPERATING MANUAL LOW-VOLTAGE DISCONNECT PANELS LVD400 & LVD600 SERIES

Sapling Converter Box

MAXIMA+ Series Rotary Level Indicator

PIM-Mini Pulsed Current Source Operation Manual

Instruction Sheet ICLS-COOL TM. Quiet-Cool Series Closet Cooler ICLS-COOL1 ICLS-COOL2

Instruction Manual IM E Table of Contents

MFJ ENTERPRISES, INC.

TB-100 ControLynx Terminal Block

EMS Electrical Management System

SX2200 Series INSTALLATION INSTRUCTIONS. Electronic Systems Protection, Inc 8001 Knightdale Blvd. Suite 121 Knightdale NC 27545

The power behind competitiveness. Delta Infrasuite Power Management. Power Distribution Unit. User Manual.

OPERATIONS MANUAL PCM-DOC

INSTRUCTION MANUAL RA 19-5B RACK ADAPTER HOT SWAP RACK ADAPTER FOR HSF SERIES POWER SUPPLIES

Installing the Cisco MDS 9020 Fabric Switch

Instruction Manual. CT-4 High-Current Transformer

Vocia ELD-1. Operation Manual

POWER AVAILABILITY 2U POD USER MANUAL. Power Output Distribution 120 Volt

I/O Expansion Box Installation & Operator s Instruction Manual

TDM-170 TIMER DISPLAY

INSTRUCTION MANUAL RA 19-6B RACK ADAPTER HOT SWAP RACK ADAPTER FOR HSF SERIES POWER SUPPLIES

Breaker Panel Technical Practice NPDRP1114

Westell. Breaker Panel Technical Practice NPDRP1114

Instructions for Operation of S&C Test Accessory Catalog Number TA-2669

VIP-480AL IP One-Way Horn

MS-SL12-RD. 17-Outlet LCD Display Power Strip 20Amp INSTRUCTION MANUAL

TDM-150 TIMER DISPLAY

INSTRUCTION MANUAL RA 19-4B RACK ADAPTER HOT SWAP RACK ADAPTER FOR HSF SERIES POWER SUPPLIES

User Guide. DMXSM-H18 Splitter. DMXSM-H81 Merger. Document Release Aug Revision B

Contents. HP E1586A Rack Mount Terminal Panel User s Manual

User s Manual. PCI Bus Expansion Adapter for PCI Bus PC-Slot EAD(PCI)BE PCI Bus Expansion Adapter for Low Profile PCI PC-Slot EAD(LPCI)BE

Sonic Ruptor 400. User Manual

INSTALLATION AND MOUNTING MANUAL

HUBBCOM GSC3000/GSC4000 Flush-Mount Smart Controller Quick Installation Guide

Adjustable Timing Control PN 8680

4300 WINDFERN RD #100 HOUSTON TX VOICE (713) FAX (713) web: IMPORTANT!!!

DIGITAL VOLTAGE INDICATOR

Debitek Card Revalue Station Installation Manual

Two Channel 48 Volt Phantom Power Supply. Artcessories. User's Manual

INSTRUCTION MANUAL RA 19-7B RACK ADAPTER HOT SWAP RACK ADAPTER FOR HSF SERIES POWER SUPPLIES

MFA-0801 & MFA-1201 D-M-E Smart Series Low Voltage Temperature Control System. User s Manual. D-M-E Company

Secured Series: Hub Plus Kit Single Door Controller Package Installation Manual

ipad Charge & Sync Cart Model MCC2 ipad Cart 430-MCC2-User Manual-010 Is a Registered Trademark of Apple Inc. ipad

Specifications 1 Installation Procedures 2 Wiring Diagrams 3 Installation Checklist 5 Maintenance 5 Warranty Information 6 Material Return Policy 6

Operating Instructions

MFJ ENTERPRISES, INC.

Agilent Technologies E5339A 38-Pin Low-Voltage Probe

User s Guide. OM-CP-PRHTEMP2000 Pressure, Humidity and Temperature Data Logger with LCD

SmartBoom PRO PHS-SB100-4F, PHS-SB100-5M, PHS-SB100-U, PHS-SB200-4F, PHS-SB200-5M, PHS-SB200-U. Operating Manual

Power Supply (48Vdc, 2.5A)

ACLD Channel Opto-isolated Digital Input Board

Digital Lighting Systems, Inc.

Pit Transition with 24" Fan Installation and Operators Instruction Manual

User Manual AIMB-C200. Economical Embedded Chassis for Mini-ITX Motherboard

Resolver to Digital Expansion Board

S82S (3/7.5-W Models)

V E2B Snap-in I/O Module

Instruction Manual. Balanced Audio Upgrade Installation. iport IW-21/IW-22 Upgrade Kits. Balanced Audio Upgrade Kit. (iport IW-21)

RE-82 RACK MOUNT DIMMER OWNERS MANUAL. 8 X 2400Watts. Revision /29/2007

Instructions. TLA5Fxxx, TLA6Fxx, & TLA7Fxx PowerFlex Field Upgrade Kits for TLA5000, TLA600, and TLA700 Logic Analyzers

FA-2448 SIX POSITION Filter Wheel

EMS Electrical Management System

Installation Guide for Flex Tap

Transcription:

POWERVAR Single Phase Power Conditioners User s Guide Industrial Conditioners GPI Series B Conditioners GPI Series 1 Conditioners 2-15 kva Single Phase Conditioners GPI Series 1 Conditioners RoHS Compliant

Notices with regard to trademarks, copyrights and documentation Copyright POWERVAR, Inc. 2004 All rights reserved. POWERVAR is a registered trademark of POWERVAR, Inc., Waukegan, IL, Other trademarks may be pending. No part of this manual may be reproduced or distributed either electronically or in printed form without the express written permission of POWERVAR, Inc. Information in this manual is subject to change without notice. POWERVAR, Inc. may make improvements and/or changes in this manual, or in the product, described in this manual, at any time without prior notice. Changes may periodically be made to the information herein, and such changes may be incorporated in new editions of the product and it s accompanying documentation without obligating POWERVAR to update information and/or product that has been delivered earlier. POWERVAR assumes no liability for typographical errors in this documentation. POWERVAR shall not be liable for technical or editorial errors or omissions contained hererin, nor for incidental or consequential damages resulting from our furnishing of this material and/or documentation to any user, nor for the performance or use of this product. In the interest of continuous product improvement, POWERVAR, Inc. reserves the right to change product and/or documentation, and/or specifications without prior notice.

THANK YOU Thank you for your purchase of this power conditioning solution. Our broad family of power conditioning products is designed to protect sensitive electronic systems from the destruction, degradation, and disruption caused by electrical power disturbances. The model you have purchased is designed for use with a wide variety of electronic systems including terminals, workstations, LAN servers, telecommunications KEY and PBX systems, point of sale systems, medical instrumentation, programmable logic controllers, digital control systems and many others. INSPECTION Remove the power conditioner from the shipping container and inspect it for shipping damage. Do not install or operate the product if it appears to be damaged in any way. If damaged, notify the carrier and the company that sold it to you immediately. ENVIRONMENTAL ISSUES This power conditioner has environmental requirements similar to other computer and electronic equipment. It has been designed for indoor use only, in areas where it will not be exposed to excessive dust or moisture. Make certain that there is adequate airflow around the unit. If the unit has air vents, do not place objects on top of or near the unit in such a way as to block the vents. TECHNICAL AND SERVICE ASSISTANCE Technical and service assistance is available in North America between the hours of 8:00 a.m. and 5:00 p.m. Central Time by calling 800-369-7179 (in Illinois, call 847-596-7000). In EMEA, contact POWERVAR at +44 (0) 1793 553980. Technical and/or service problems and/or questions may also be placed with POWERVAR at our website at www.powervar.com. Click on SERVICE and follow the appropriate link. CUSTOMER SERVICE For service, obtain the model number, part number, and serial number from the rear panel data plate. Then contact POWERVAR via phone or web to obtain a Return Material Authorization (RMA) number. This number must be marked on the shipping container and packing slip of the unit being returned. The original shipping container should be used if available. Additional charges will apply for repair of damages caused by improper packing of the returned unit. Unauthorized return shipments will be refused. Units for repair must be shipped prepaid to POWERVAR.

WARRANTY POWERVAR warrants its power conditioners (known hereafter as the product") to be free from defects in materials and workmanship for a period of five years from the date of shipment. The product will be repaired or (at POWERVAR s option) replaced at no charge during this warranty period. Product must be returned prepaid. POWERVAR makes no warranties, expressed or implied, of merchantability, fitness for a particular purpose, performance, condition, capacity or otherwise. The manufacturer is not liable for incidental or consequential damages, monetary loss, loss of sales or loss of business resulting from the failure or malfunction of the product. Warranty is void on any product that is misused, misapplied, abused, altered, repaired by unauthorized personnel, or where evidence of tampering exists. The foregoing constitutes the sole and exclusive remedy of the purchaser and is in lieu of all other warranties. No greater degree of liability is imposed on the manufacturer. INSTALLATION AND OPERATING INSTRUCTIONS Please consult Appendix A for installation and operating instructions on the following models: ABC360-91IND ABC750-91IND ABC1000-91IND ABC1500-91IND Please consult Appendix B for installation and operating instructions on the following models: ABC500-91BUI ABC1000-91BUI ABC1500-91BUI ABC2000-91BUI ABC3000-91BUI ABC500-92BUI ABC1000-92BUI ABC1500-92BUI ABC2000-92BUI ABC3000-92 BUI ABC500-91 ABC1000-91 ABC1500-91 ABC2000-91 ABC3000-91 Please consult Appendix C for installation and operating instructions on the following models: ABC2000-2S ABC2030-2S ABC3000-11 ABC3030-11 ABC3000-2S ABC3030-2S ABC3300-33 ABC3800-11 ABC3830-11 ABC3800-2S ABC3830-2S ABC5000-2S ABC5000-33 ABC5030-2S ABC5800-2S ABC6030-2S ABC8000-2S ABC10.0-2S ABC15.0-2S PLEASE NOTE: SOME OF THE ABOVE MODELS CAN BE QUITE HEAVY. POWERVAR RECOMMENDS THAT INSTALLERS REQUEST ASSISTANCE IN MOVING, POSITIONING OR HOLDING HEAVY ITEMS DURING THE INSTALLATION PROCESS TO AVOID PERSONAL INJURY.

APPENDIX A INSTALLATION INDUSTRIAL POWER CONDITIONERS GENERAL INSTALLATION This device is designed for permanent mounting inside a control cabinet or to a wall or other solid structure using #10 hardware. The conditioner has a dustproof and splashproof enclosure and may be mounted in any position. This device is intended for use in hardwired installations. WARNING: TO PREVENT ELECTRICAL SHOCK, BE CERTAIN TO TURN OFF ALL ELECTRICAL POWER BEFORE CONNECTING THE POWER CONDITIONER TO THE POWER LINE AND BEFORE CONNECTING THE LOAD TO THE POWER CONDITIONER. A Phillips screwdriver is required to remove the power conditioner cover. Once the cover has been removed, carefully set it to one side. This power conditioner is installed by connecting input power to terminal block TB1 and output power to terminal block TB4. The terminal blocks are designed for a maximum wire size of 8 AWG. Access to these terminal strips is via the side, top or bottom knockouts. Input power should be fed through a properly sized circuit breaker at the panelboard. All applicable electrical codes must be observed for the installation of this device. The data plate on the conditioner lists the current and voltage rating of this device. The total current of all connected loads must not exceed the maximum total current rating. An automatically resetting thermal cut-off switch is embedded in the transformer to protect against prolonged overcurrent. WARNING: DO NOT CONNECT INPUT OR OUTPUT POWER CONNECTIONS TO TB2 OR TB3. THESE TERMINAL STRIPS ARE ONLY FOR USE IN SETTING THE POWER CONDITIONER S INPUT OPERATING VOLTAGE. Unless specified differently at the time of order, the power conditioner has been set during manufacture by the factory for a 480-volt input. The input voltage of the power conditioner is selectable from 480, 240, 208 or 120 volts and may be changed by moving the jumpers on BOTH TB2 and TB3. See Figure 1 that follows for proper jumper positioning and an example of how the conditioner may be rewired. When connections are completed, replace the cover before applying power to the power conditioner. Caution: WHEN CHANGING INPUT VOLTAGE SETTINGS, YOU MUST CHANGE JUMPERS ON BOTH TB2 AND TB3. FAILURE TO DO SO MAY DAMAGE THE POWER CONDITIONER AND VOID THE PRODUCT WARRANTY. For the best power conditioning results, all load equipment ground leads should be connected to a common point. A single point ground bus-bar is provided on the lower mounting flange for this purpose. OPERATING INSTRUCTIONS Energize the circuit feeding the power conditioner by placing the panelboard circuit breaker in the ON position With a voltmeter, check that the power conditioner output voltage is 120 volts Turn on the load equipment and test for proper operation.

Figure 1 INDUSTRIAL POWER CONDITIONERS

APPENDIX B INSTALLATION GPI SERIES B AND GPI SERIES 1 GENERAL INSTALLATION POWERVAR GPI Series B and GPI Series 1 power conditioners utilize an isolation transformer permitting the user to select from one of four different input voltages. Series B models are designed for hardwire installation and may be mounted in any orientation using the mounting holes provided. Series 1 models are equipped with a power cord and receptacles and are designed for standalone operation.* The data plate attached to the power conditioner lists the current and voltage ratings of the device. Care must be taken that the total current demand of all connected loads does not exceed the maximum current capability of the power conditioner. GPI Series B conditioners are available in two versions. Models with the suffix -91BUI are designed for use with loads requiring 120 volt power. Models with the suffix -92BUI are designed for use with loads requiring 240 volt power. Unless specified differently at the time of order, Series B power conditioners have been pre-configured by the factory for a 120-volt input. Series 1 power conditioners are ordered for a specific input voltage and the circuit breaker installed in the unit is the correct one for the selected operating voltage. The input voltage of both the GPI Series B and Series 1 can be set to 100, 120, 208, or 240 volts by changing jumpers on terminal block TB1 as shown in Figure 2. Series B power conditioners must be matched with a circuit breaker that is appropriately sized for the input current. The following table illustrates maximum current ratings for each model size when operated at different nominal input voltages. NOTE: IF THE OPERATING VOLTAGE OF A GPI SERIES 1 POWER CONDITIONER IS CHANGED, IT WILL BE NECESSARY TO INSTALL A DIFFERENT CIRCUIT BREAKER WITH APPROPRIATE CURRENT RATINGS. For -91BUI and -92BUI Models VA Rating 500VA 1000VA 1500VA 2000VA 3000VA Voltage Tap 100V 5.5A 10.4A 15.50A 20.4A 30.4A 120V 4.35A 8.62A 12.9A 16.9A 25.50A 208V 2.50A 5.00A 7.6A 10.1A 15.15A 240V 2.17A 4.31A 6.45A 8.44A 12.7A Output current at full load VA Rating 500VA 1000VA 1500VA 2000VA 3000VA Model suffix -91BUI 4.16A 8.33A 12.5A 16.66A 25.0A -92BUI 2.0A 4.16A 6.25A 8.33A 12.5A *GPI Series 1 power conditioners are not safety agency listed.

APPENDIX B INSTALLATION GPI SERIES B AND GPI SERIES 1 The table below lists the appropriate breaker for a variety of input currents. These breakers may be purchased from: Eaton Corporation Commercial Controls Division, Heinemann Products Phone: (800) 962-0820, Fax: (414) 449-6118 Input Amps Circuit Breaker Part Numbers 2.25 JA2S-A38-A-2R25-25-H 10.50 JA2S-A38-A-1050-25-H 2.50 JA2S-A38-A-02R5-25-H 12.75 JA2S-A38-A-1275-25-H 4.50 JA2S-A38-A-04R5-25-H 13.00 JA2S-A38-A-0013-25-H 5.00 JA2S-A38-A-0005-25-H 15.25 JA2S-A38-A-1525-25-H 5.50 JA2S-A38-A-05R5-25-H 15.50 JA2S-A38-A-1550-25-H 6.50 JA2S-A38-A-06R5-25-H 17.00 JA2S-A38-A-1700-25-H 7.75 JA2S-A38-A-7R75-25-H 20.50 JA2S-A38-A-2050-25-H 8.50 JA2S-A38-A-08R5-25-H 25.50 JA2S-A38-A-2550-25-H 8.75 JA2S-A38-A-8R75-25-H 30.50 JA2S-A38-A-3050-25-H 10.25 JA2S-A38-A-1025-25-H OPERATING INSTRUCTIONS WARNING: BEFORE MAKING CONNECTIONS TO GPI SERIES B POWER CONDITIONERS OR BEFORE CONFIGURING INPUT VOLTAGE ON EITHER GPI SERIES B OR SERIES ONE CONDITIONERS, BE CERTAIN TO TURN OFF ALL ELECTRICAL POWER. FAILURE TO OBSERVE THIS PRECAUTION MAY RESULT IN ELECTRICAL SHOCK. GPI Series B Complete all input and output connections. Select input operating voltage that is correct for the application. Tun input circuit breaker ON. Using a voltmeter, carefully measure output voltage to verify that output is nominal 120 volts. If nominal output voltage is 120 volts, turn all load equipment on. GPI Series 1 Plug GPI Series 1 into appropriate power receptacle and turn input breaker ON. Using a voltmeter, measure output voltage to verify that output is nominal 120 volts. If nominal output voltage is 120 volts, turn all load equipment on.

Figure 2 INPUT VOLTAGE ADJUSTMENT GPI SERIES B AND GPI SERIES 1 ABC500-XX ABC1000-XX ABC1500-XX ABC2000-XX, ABC3000-XX

APPENDIX C INSTALLATION 2 to 15 kva SINGLE PHASE CONDITIONERS GENERAL INSTALLATION This device may be permanently mounted using ¼ inch hardware. Sheet CC in this manual is provided for your use as a mounting/installation template. IMPORTANT NOTE: Models ending with the suffix -2S may be configured for either 208 or 240 volt input. Unless specifically ordered from the factory with a 208 volt input voltage, the power conditioner will arrive configured for 240 volts. The input voltage may be changed between 240 and 208 volts by referring to the instructions accompanying Figures 3 and 4. LINE CORD/RECEPTACLE MODELS Install the power conditioner as close as possible to the load equipment. Do not use extension cords, surge protectors, or filtration devices. For line cord/receptacle models, plug the power conditioner into a properly sized AC power source. Then connect the load equipment to the power conditioner receptacles. WARNING: TO PREVENT ELECTRICAL SHOCK, BE CERTAIN TO TURN OFF ALL ELECTRICAL POWER BEFORE CONNECTING THE POWER CONDITIONER TO THE POWER LINE AND BEFORE CONNECTING THE LOAD TO THE POWER CONDITIONER. HARDWIRED MODELS A Phillips screwdriver is required to remove the power conditioner cover. Once the cover has been removed, carefully set it to one side. The input and output terminal blocks are located at the rear of the unit and are accessed by removing the knockouts on the back panel. Terminal blocks are designed to accept a maximum wire size of 8 AWG and 8 foot-pounds of torque. All applicable electrical codes must be observed for the installation of this device. When wiring connections are complete, replace the cover before applying power to the power conditioner. OPERATING INSTRUCTIONS If power was turned off at the panel prior to installation, switch the panel circuit breaker to the ON position. Turn on the power conditioner circuit breaker and check that output voltage is correct (120V for 11 models, 208V for 33 models or 120/240V for 2S models) Turn on all load equipment and test for proper operation. Once these steps have been taken, the power conditioner circuit breaker may be used as a master power switch if so desired. The data plate on the rear of the conditioner lists the current and voltage rating of this device. Models with multiple receptacles indicate the maximum current rating for each receptacle. Take care not to exceed the maximum rating of individual receptacles and that the sum of all load currents does not exceed the current rating on the data plate.

Figure 3 2 kva 6 kva NOTE: For input voltage conversion on models ending with suffix -2S only: To convert 208 volt input to 240 volt input, move circuit breaker lead from point E2 of the printed circuit filter assembly to point E3 To convert 240-volt input to 208-volt input, move circuit breaker lead from point E3 of the printed circuit filter assembly to point E2. Factory default setting is 240-volt input (unless specified differently at time of order with factory).

Figure 4 8, 10, 15 kva Input voltage adjustment taps this side of transformer NOTE: For input voltage conversion on models ending with suffix -2S only, adjust taps on left side of transformer (when viewed from rear of conditioner). Moving taps permits changing of input operating voltage between 208 and 240 volts.

In North America, South America, and the Caribbean: 1450 Lakeside Drive Waukegan, IL 60085 Phone: 847-596-7000, Toll Free (outside Illinois only): 800-369-7179 Fax: 847-596-7100 In EMEA: Unit 5 Birch, Kembrey Park Swindon, Wiltshire SN2 8UU, United Kingdom Phone: +44 (0) 1793-553980, Fax: +44 (0) 1793-535350 Access additional product information and support on the web at http://www.powervar.com You may register your ownership of POWERVAR products on our website at http://www.powervar.com. This will enable us to communicate with you if product issues, which might affect your satisfaction or safety, should arise. SM503 RevC 11/23/04 2004 POWERVAR, Inc.