Operating Manual. AdirPro HV8RL Red Beam Horizontal/Vertical Laser level

Similar documents
TEL: / FAX:

Instruction Manual. Electronic Horizontal & Vertical Self-Leveling Rotary Laser Level Model Nos , ,

Instruction Manual. Electronic Self-Leveling Dual Grade Horizontal / Vertical Rotary Laser Model No

LS516/LSG516 Self-leveling Rotating Laser Instruction Manual ( )

Dear user, Thank you very much for purchasing LS533H rotary laser. Please read this instruction manual before operating it.

Auto-leveling Rotating Laser (RL430G)

Self-Leveling Cross Line Laser Level with 3 Vertical Lines Model No Instruction Manual

Self-leveling Laser Marker (4V1HXL)

Mk II 3DR MULTI-LINE LASER INSTRUCTION MANUAL

LSL250. Laser light! Do not stare into the beam or view directly with magnifiers. Class 2 laser EN :

Thank you very much for purchasing LAISAI LS686 line laser, please read this instruction manual before operating it. Content

Cross Line Laser kit. User Manual for EK-226P

QUAD 1000 OWNERS MANUAL OPERATION GUIDE

from P.R.Engineering Ltd Tel:

Instruction Manual. 24" and 48" Waterproof Electronic Digital Level Model Nos &

Green Rotary Laser Level

Instruction Manual. 24" and 48" Electronic Digital Level Model Nos &

LA 90L / LA 180L. Operating instructions

Instructions. Remote Controlled Rotator RCR

TABLE OF CONTENTS DISCLAIMER COPYRIGHT NOTICE TRADEMARK DISCLAIMER. RED Focus Operation Guide Version 1.1 August 17, 2011

VERTICAL CONTROL LASER OWNERS MANUAL

LDM M LASER DISTANCE MEASURER

LAR 350 rotation laser: Tough DUAL SLOPE laser kit Made in Germany. World s first MOTION CONTROL

Laser Operations Guide

Operating Instructions TPL 50 HV

ECOLINE EL 515 PLUS EL 515 PLUS SET

Instruction Manual EN

MultiLine Please read these instructions before operating the product. 5 - Beam Self-Leveling Multi-Line Laser

NIDEC-SHIMPO INSTRUMENTS

The Nureva Span ideation system. Installation guide. Single panoramic system

HD Analog Camera User s Manual

Receiver REC 300 Digital. Operating instructions

HD40H(X) Performance Series Camera. User Guide

Overview 2. Technical data 3. Instrument Set-up 4. Operations 7. Message Codes 9. Accuracy Check 10. Care 13. Warranty 14. Safety instructions 15

Instruction Manual EN

Leica Lino ML90, ML180

Blue Weapon Laser. User manual UK. Version 1.0

FT-20 Fire Training Fog Machine User Manual English

CLLi Please read these instructions before operating the product. 2 - Beam Self-Leveling Cross Line Laser

Model DT-315P DIGITAL STROBOSCOPE INSTRUCTION MANUAL

Greenline-Laser 3P / 5P

TURBO HD TVI Bullet & Turret Camera

EVERSAN. Instruction Manual MODEL 9007/9008 TENNIS SCOREBOARD. Address: 34 Main Street, Whitesboro, NY 13492

Geo3X HP BEDIENUNGSANLEITUNG USER MANUAL MODE D EMPLOI

HCC-CW-201A. CWDM Analyzer. Operation Guide

1. Safety instructions

DUAL LASER PACK & CONTROLLER USERS MANUAL

A-300 Speed Dome. Quick Start Guide

HD-CVI Camera User s Manual

1. PRECAUTIONS. Thank you for choosing RUIDE theodolite Disteo 23. Please read this manual carefully before use.

Available in 2.0MP, 4.0MP and 8.0MP variants

Vibration Meter and Laser Combination Tachometer

Amcrest AMC720BC and AMC720DM HDCVI Camera s User's Manual

Laserlyte-Flex Userguide

MBE Mounts and Adapters

SHIMPO INSTRUMENTS. ST-320BL LED Stroboscope Array Operation Manual

HD Analog Camera User's Manual

862 PROLASER CROSS LINE LASER

Available in 2.0MP, 4.0MP, 6.0MP and 8.0MP, with 2.8mm and 3.6mm lenses.

Gobo Projector XP 80W

CONTENTS. Model no: NT-013

ITA100 MKII 100mW green DMX laser

DE EN FR. S-Digit multi + BEDIENUNGSANLEITUNG USER MANUAL MODE D EMPLOI

FT-20 Fire Training Fog Machine User Manual English

IMPORTANT SAFETY INSTRUCTIONS

HD Mini IR Waterproof Fixed Network Camera. Quick Start Guide. Version 1.2.0

Spectrum Laser. User manual UK. Version 1.0

INSEBO2IRF 2.1MP 1080P IP Eyeball Camera with IR

IGB Series. Operation Manual. Platform Scale. Kg/Lb Specification IMPORTANT

1. Product Overview. Thank you for purchasing the Laserlyte Flex Development Kit. The module in this kit emits a red spot or projection.

Owner s Manual & Safety Instructions

User's Guide. Vibration Meter and Laser Combination Tachometer Model

PORTABLE HOME SECURITY VIDEO CAMERA

Robot Light V2. User Manual

Titanium Bedienungsanleitung Operating instructions ( ) / Rev 07.

KEZ-c1TR28V12XIR HD-TVI 720p Low Light Varifocal IP66 EXIR Turret Cameras with OSD, CVBS Test Output and UTC Control

CX1 Outdoor Color-Changing Wireless Bluetooth Speaker Please fully charge the speaker prior to first use!

1. Product Overview. Thank you for purchasing the Greenlyte Development Kit. The module in this kit emits a green spot or projection.

ESV1018 Quantum Illuminator Cabinet INSTRUCTION MANUAL

MODEL 9360-SO SOCCER SCOREBOARD

Camera. Network Bullet Camera. Quick Operation Guide

LaserLyte-Flex Red & Green Alignment System

Operational Manual Spectrophotometer Model: SP-830 PLUS Metertech Inc.

PA Series. Available in 6.0MP and 8.0MP

Manual. Infrared cameras. Contour M

PD Way Pan/Tilt Head. You re on steady ground

Eco D-ELS-4 Stereo Microscope. Instruction Manual

Rotary laser for outdoor areas

POWER SUPPLY UNIT PSU-3

Dome Camera. Hardware Manual Z81, Z /01/08

BPL SERIES INSTALLATION INSTRUCTIONS THIS SHEET CONTAINS IMPORTANT SAFETY INSTRUCTIONS. SAVE THESE INSTRUCTIONS.

Laser Light Projector User s Manual Shenzhen Optlaser Technologies Co., Ltd Model: AL-RG130-RM1

Lyte-MV Digital Userguide Red & IR Versions

HD Analog Camera User s Manual

Rotary Laser Service Manual

dedicated KVM switch and rackmount screen technology User Manual CV-1201D DVI-D KVM Designed and manufactured by Austin Hughes

Laser Projection keypad

Operating instructions: STABILA Electronic-IP65

KEZ-c2TR28V12XIR HD-TVI 1080p Varifocal IP66 Super Beam IR True WDR Turret Cameras with OSD, CVBS Output and UTC Control

FengMi Wemax One Laser Projection TV

Transcription:

Operating Manual AdirPro HV8RL Red Beam Horizontal/Vertical Laser level

Maintenance and Safety The HV8RL is a class II laser according to 21CFR1040. Be careful not to expose your eyes to the laser beam. Direct exposure to the laser beam for a long period of time may be hazardous to your eyes. Do not try to dismantle the instrument by yourself. Have it repaired by your dealer or supplier. Dismantling it by yourself may worsen the problem and void your warranty. When mounting the instrument to a tripod, make sure the instrument is securely fixed. The tripod leg clamps should be securely fastened. If it is not securely fastened or tightened, the main unit can fall off and/or the tripod could fall over. Always clean the unit after use. Use a clean cloth moistened with a neutral detergent or water. Make sure the unit is completely dry before storage. Store the unit in the included carrying case with cushioning material. Make sure it is not subject to vibration, dust, high moisture or extreme temperature. The unit may not function properly if used out of the normal temperature range. When transporting the unit, be careful to avoid impact or vibration. Before starting to work, check that the unit is functioning correctly. Do not attempt to charge standard alkaline batteries or the warranty will be voided. Do not disassemble the unit. In case of inappropriate repairs, laser radiation may arise in excess amounts and liability may be incurred if there is damage. In cases of inappropriate processing, malfunctions are possible without external visible damage. This unit contains nickel-metal hydride batteries. Nickel-metal hydride batteries must be recycled or disposed of properly. WEEE-Reg: DE23874031 1

2

Your HV8RL Unit includes the following: HV8RL Main Instrument Detector (LD-8) and Bracket (BR-8) Remote Control (RM-8) Charger (FC100) Target Glasses Hard Case with Foam Insert (FCC300) Extra Alkaline Battery Pack c/w 4xAA alkaline batteries (FBP100). Wall Mount Bracket Please contact your dealer if any of the above parts are missing. 3

Find your way around the HV8RL Light House Optical Glass Rotating Head Handle Control Panel Base Rubble Cover 4

Control Panel Power Switch Accelerate Left Spin Right Spin Direction Scan Windy Manual/Auto H.I Alert 5

Operation of Panel Power Switch: Turns the unit on and off. Power Light: When the red light is on, the instrument is on. Manual/Auto: After being powered on, the unit will enter into self leveling mode. Press Manual/Auto once, and the device will enter into manual mode. Now the slope of Y-axis can be adjusted by the up and down arrows on the keypad panel. While pressing Manual/Auto again, the slope on X-axis can be set up by the two arrows on the panel. During this time, the other functions such as scanning, left spin or right spin are also available but without accuracy. When pressing Manual/Auto the third time, the laser will go back to Auto-level mode and will self-level again. Manual/Auto indicator: When the Y indicator lights is on, the slope of the Y axis can be adjusted. When the X indicator turns on, the X-axis slope can be adjusted. Accelerate: To change the speed of the rotating beam, press this button multiple times to adjust the speeds to 0rpm, 60rpm, 300rpm and 600rpm. T ilt/h.i Alert: Enabling this mode warns the user if the laser level has been jolted. T ilt Indicator: When the light is blinking slowly, the laser is in H.I alert mode. When the light is blinking quickly, 6

the laser level will not level as it has been jolted. Directional Scan: Circling knob. Angle of scanning includes 5 levels: 0-10 -45-90 -180 Left Spin: Allows the laser beam to step/move counter-clockwise. Unit must be in 0 RPM or scan mode. Right Spin: Allows the laser beam to step/move clockwise. Unit must be in 0 RPM or scan mode. Up & Down Arrows: Adjust the slope for both axes by working together with Manual/Automatic button. Windy: Laser will be in continuous rotating/self-leveling mode during high winds, heavy vibrations, and shocks. The Windy mode will not affect the accuracy. 7

Directions: Battery Installment Both rechargeable and alkaline battery packs can be used for this laser. To replace the batteries, follow these instructions: 1. Unscrew the bolt at the bottom of the base. Take out the battery pack. The laser is officially c/w a Ni-Mh battery pack. 2. Place the battery pack into the port according to the right electrode. 3. Re-screw the bolt at the bottom of the base. Instrument Placement Horizontal scanning Place the instrument on a tripod or stable flat surface, or hang it on a wall. Set the unit upright, and keep the slope of the instrument within the range of -5 to +5 self-leveling range. Vertical scanning Place the instrument on a flat surface, and keep the slope of instrument within the range from -5 to +5, 8

Operations Power Press the ON/OFF key to switch the laser on. If the power indicator light blinks, the voltage of the batteries is low and batteries need to be replaced or recharged. Leveling The Unit will automatically level when you turn it on. The leveling process is indicated by a blinking LED light. After being leveled, the laser rotating head will rotate at the speed of 600 RPM. If the instrument is placed improperly, or the slope of instrument exceeds the range of -5 to +5, the mode indicator and the laser beam will blink at the same time. Note: The instrument will shut down automatically if the unit exceeds the self-leveling system range for more then 5 minutes. Spinning Continuous spinning Press the Rotational speed adjustment key to control the spinning speed of the laser. By pressing the key repeatedly, the spinning speed of the laser will continuously change to: 0rpm, 60rpm, 300rpm and 600rpm. 9

Stepping spinning Adjust the High Speed Key at the speed of 0 rpm, and the laser will stop spinning. Press the Right Spin key and the laser will step-move clockwise. Then if you press the Left Spin key, the laser will step-move counter-clockwise. Directional scanning Adjust the High Speed key at speed of 0 rpm, the laser will stop spinning. Press the Direction Scan key and the laser will scan directionally. If you press the key repeatedly, the angle of scanning of the laser will continuously change as follows: 0-10- 45º-90-180 -0. Press the Left Spin key or the Right Spin key to change the direction of scanning. Slope Adjustment When the unit is upright for horizontal rotation, the slope of the X-axis and Y-axis can be adjusted by using manual mode. Press the Manual/Auto key, and the unit will first enter into the mode of manual adjustment. The Y indicator lights. Slope of Y-axis a. Aim the Y1-beam to the direction of the slope required. b. Press the or arrow to move the laser beam up or down until the beam/line gets to its required position. 10

Slope of Y-axis a. Press Manual/Auto again to switch laser into X axis. At this time, the X indicator will light up. Aim the X1-beam to the direction of the slope required. b. Press the or arrow to move the laser beam up or down until the beam/line gets to its required position. Quit slope adjustment mode Press Manual/Auto key again. After both indicators (X&Y) goes off, the instrument will quit the slope adjustment mode/manual model and will self-leveling again. 11

Vertical Lines Place the Unit in the position shown above; press the button on the bottom left hand side of the panel. The instrument will Auto level and start spinning giving a Vertical beam. 12

Power Plug Hole Alkaline Battery Pack Insert the charger into the charging socket of the main unit or the battery pack. Turn on the power. The charger will show one of 3 modes. Red flashing light - Battery not charging Red light - Battery on charge Green light - Battery charged 13

If the red light is on, check the connection. If the red light is flashing please wait for charging to complete. Once the green light shows, the instrument is fully charged and is ready for use. Charging normally takes 7 hours and provides 20 hours of use. Either Ni-Mh battery pack (the standard one) or Alkaline battery pack is available to work as a power supply. Notices: (1) Using the standard rechargeable batteries of the instrument, recharging will be finished within 8 hours. (4x5000mAh Ni-Mh batteries) (2) Power required for the charger: Frequency: 50-60HZ; Voltage: 85-265V. (3) You can simultaneously charge and use the unit at the same time. (4) If you leave the unit unused for a long time, the batteries (dry battery or rechargeable battery) need to be removed before storage. (5) Brand-new rechargeable batteries or long-time unused rechargeable batteries need to be recharged and drained three times to attain the capacity required. 14

RM-8 Remote The remote control of the instrument uses infrared technology. Aim the aperture of the infrared ray to the instrument (as depicted below) to bring the remote control into function. Available distance: indoor: 100 feet (30m); outdoor: 65 feet (20m). The keypad panel includes 9 keys; the indicator on the RC will blink to show the operating signal has been sent out once pressing any key. The remote can fulfill the following functions: (1) Spinning. (2) Directional scanning. (3) Slope adjustment. 15

LD-8 Rotary Detector The detector will pick up a spinning beam when it crosses the electronic sensor window. The detector has 3 buttons: a) On/off button b) Sound button: with 3 settings off low high c) Sensitivity button: will give either a narrow or a broader range of detection. When the detector is too high, a slower beep will be emitted. When too low, a fast beep will be emitted. When it is leveled, a continuous pitch will sound - at this point the center of the detector is at the same alignment as the beam. To get accurate results use the built-in bubble to keep the detector leveled. The detector is powered by a standard 9v battery. 16

Accuracy Checking Follow these instructions for checking axis accuracy. Horizontal-surface Checking 1. Place the unit approximately 160 feet (50m) in front of a wall, and then adjust the level of the base approximately to aim the X1 to the wall, as shown below: 17

2. Allow the unit to level and begin rotating. Mark the beam position on the wall or scale plate as H1 and turn off the unit. 3. Loosen the tripod screw, rotate the Unit 180 and re-secure it on the tripod, (do NOT change the height) Turn on the unit. 4. Allow the unit to level and rotate. Mark the beam position on the wall or scale plate as H2. The difference between the value of H1 and H2 should be less than 0.39 inches (10mm). 5. Repeat the same process to check your Y (Handle area) axis. Again, the difference between the values of the two measurements should be less than 0.032 inches (10mm). 6. If the difference in either axis is more than 0.026 inches (8mm), the unit should be sent to your authorized dealer for service/calibration. 18

Horizontal-line checking. Place the unit on a tripod between Wall A and B and put the tripod near Wall A. Distance from the center of the tripod to Wall A should be no more than approx. 1.5 feet (0.5m) and to Wall B approx. 100 feet (30m). (Follow the instructions on illustration). Switch the unit on. After leveling, direct the laser beam onto Wall A. Mark the center point of the laser beam on the wall (Point I) 19

Turn the unit horizontally 180. (Without changing the height). After leveling, direct the laser beam onto Wall B. Mark the center point of the laser beam on the opposite Wall B (Point II). While the unit is still on the tripod, move the tripod to Wall B (do NOT turn the instrument). Turn on the unit and let it level. 20

After leveling, align the height of the unit by using a tripod or by underlying if necessary. The center point of the laser beam is now projected exactly where the previously marked point II on Wall B was. 21

D Rotate the unit by 180 without changing the height. Allow it to level and mark the center point of the laser beam on Wall A (point III). Take note that point III is as vertical as possible above or below point I. The difference (D) of both marked points I and III on Wall A amounts to the actual deviation of the plumb up beam. D-value should be less than 0.15 (4mm). 22

Technical Specifications Accuracy: 15 arc seconds (+/-1mm/10m) Self leveling range: ±5 Operation range(with detector) 1,650 feet (500m) with detector (Diameter) Four head speeds: 0, 60, 300, 600 R. P. M. Four scan widths: 10 ; 45 ; 90 ; 180 Bright, visible beam: Wavelength 635nm: Class II IR Remote control: Available distance: 65 ft. (20m) Operation temperature: -4 F~122 F (-20 C~50 C) Power supply: DC 4. 8-6V (4xsub-C NI-MH battery or 4xsub-C Alkaline battery) Continuance working time: Approx. 40 hr.(ni-mh) Approx. 30 hr(alkaline) Waterproof and dustproof: IP 55 Dimension: 6.2" (L) X 6.2" (W) X 7.2" (H) (160 X 160 X 185mm) Weight: 5.9 Lb (2.7kg) 23