Telemetry & SCADA Handbook

Similar documents
Telemetry & SCADA Handbook

Telemetry & SCADA Handbook

What is SCADA? What is Telemetry? What is Data Acquisition? Differences between SCADA and DCS? Components of SCADA. Field Instrumentation

HARDWARE OF SUPERVISORY CONTROL & DATA ACQUISITION SYSTEM

Sensaphone SCADA 3000

Preconfigured SCADA solution: Easy & Powerful

FIGURE 1. Five Logical Levels of a SCADA System

The SCADA Connection: Moving Beyond Auto Dialers

SC2000 MOTOR PROTECTION ELECTRONICS, INC. INSTRUCTION MANUAL. (407) Phone: Website:

AirCare Partners With IntelliCom

Advances in Telemetry. Finding out what is really going on in your system

SCADA Software. 3.1 SCADA communication architectures SCADA system

21 st Century Landfill Technology: Telemetry, Automation, and Alternative Power Sources

Intech Micro 2300-A8VI analogue input station MODBUS RTU slave application supplementary manual.

The SCADA Connection: Moving Beyond Auto Dialers

USER S MANUAL. DAS-G01 The Power of Tomorrow

Quick Start. Model 203 Single Channel PeakSimple Data System. STEP 2 (optional) STEP 4 STEP 5 STEP 1. STEP 3 (optional)

SCADA System Specification. Vantage Pipeline Project # May 2013

INTEGRATED SYSTEMS AND CONTROL, INC. User s Hardware Manual. PCMNET V 7. xx

INSTRUCTION MANUAL STATION CONTROLLER SC1000 MOTOR PROTECTION ELECTRONICS, INC.

SC2000 MOTOR PROTECTION ELECTRONICS, INC. INSTRUCTION MANUAL. Phone: (407) Fax: (407) Vulcan Road Apopka, Florida 32703

Innovative hardware...

Retentive On-Delay (TONR)

THE RAINBOW SCADA D-500-LITE

DL06 - the Mighty Micro

Modbus Hans-Petter Halvorsen

Paper. It s all about input, connectivity, decision making, and output instructions.

Intech Micro 2300-RTD6 analogue input station MODBUS RTU slave application supplementary manual.

Distributed control of Network devices through Remote Terminal

Trident and Trident X2 Digital Process and Temperature Panel Meter

1500ct Pump Controller

1500ct Pump Controller

CLICK PLC Product Overview

Micro-Modular Programmable Controller

INTRODUCTION - DISPLAYS, DATA LOGGERS AND SOFTWARE

SCADA Solutions Since 1981 DATA FLOW SYSTEMS

AUTOMATION OF POWER DISTRIBUTION USING SCADA

The Concept of Sample Rate. Digitized amplitude and time

Authorized Systems Integrator. Automation Systems Telemetry & SCADA

Remote monitoring and display solutions

DE SERIES. Enhanced DE-2500 System Now Available. Programmable Safety Shutdown, Monitoring and Control Products with Analog Input Capabilities

SCADA.What s out there?

Troubleshooting PLCs & SCADA Systems

NX21 USER MANUAL. Telemetry Unit. Version 1.5

INTRINSICALLY SAFE DUPLEXER PROTECTION. ELECTRONICS, INC Vulcan Road Apopka, Florida MOTOR INSTRUCTION MANUAL

MXIO. Compact I/O module. Summary. Application Compact I/O module for data acquisition and HVAC control systems. Function

D1000M SERIES FOR MODBUS SENSOR TO COMPUTER INTERFACE MODULES

Welcome to the Webinar

GRASSO SYSTEM CONTROL

Self-Powered Wireless Instrumentation

The ECL Apex 20 is operated by means of either a PC or the ECL Apex Web Panel. Temperature input signals are based on Pt 1000 or 0-10 V.

Automate and Preserve Electromechanical Relay Investment Part 3 of 3 Using the Bitronics 70 Series to Improve Remote Monitoring and Control

Dew point. Dew point set DS 400. Special features: Dew point set DS 400. Technical data DS 400. Technical data FA 410

WIRELESS REMOTE ASSET MONITORING & CONTROL

WebAccess Driver Configuration Manual

Introduction to ICS Security

PRODUCT INFORMATION. DeviceNet Triple Play Digital Communications Board. SA Actuator with AUMA Matic Motor Controls

iopro Mirrored IO System

Introduction to The PROVU &ProtEX-MAX Great New Features!

12-36 VDC/12-24 VAC Power Option 4-Digit Display, 0.56 (14.2 mm) or 1.20 (30.5 mm)

State-of-the-Art Technology

PRODUCT INFORMATION. AUMA Actuators, Inc. Pittsburgh PA USA. Triple Play Digital Communications Board DeviceNet / Modbus CDN455

Case Study: Implementation of 132kv Malegaon Sub-Station Using SCADA

Intech Micro 2300-RO4 analogue input station MODBUS RTU slave application supplementary manual.

IDM DATA ACQUISITION SYSTEM

RS-FS-N01 Wind speed transmitter user's Guide (485type)

Using MODBUS for Process Control and Automation

DATRAN XL4 PLUS RTU Quick Start Guide

TELEMETRY MEASUREMENT AND CONTROL SYSTEM

D7000 SERIES MODBUS TCP/IP ETHERNET INTERFACE MODULES

Established Leaders in Actuation Technology. In-Vision PC based supervisory control. Publication S210E issue 04/03

Keeping the Lights On: Machine Monitoring Basics

ezeio Controller and the 2400-A16 input expansion.

AC/DC MAGNETIC METER OPERATION MANUAL. Model : MG G ( Gauss), mt ( milli Tesla ), USB/RS232. Your purchase of this

MAS-200 Modular assembly system

Serial Communication

June 2018 System Planner

Smart Energy & Power Quality Solutions. ProData datalogger. Datalogger and Gateway

INDUSTRIAL QUALITY INTERFACES & PROTOCOL CONVERTERS

AC/DC MAGNETIC METER OPERATION MANUAL. Model : PCE-MFM G ( Gauss), mt ( milli Tesla ), USB/RS232. Your purchase of this

FTM84/85 Feature Application. Temperature & Humidity / Flow Measuring Specialist

Observatory Automation Project

3/2/ /2/ :05 AM EET 415/4 Power System Operation 1 3/2/ :05 AM EET 415 2

1 Introduction. Objectives. 1.1 Introduction. When you have completed study of this chapter you will be able to:

AUTARKIC PROCESS MANAGEMENT

SC1000 MOTOR PROTECTION ELECTRONICS, INC. INSTRUCTION MANUAL. Phone: (407) Fax: (407) Vulcan Road Apopka, Florida 32703

RTU and control in the same device

Table of Contents 1 ABOUT THIS GUIDE CONTACT INFORMATION ANTENNA INSTALLATION... 4

Panel Indicators. NEW 4~20mA Panel Display. Process Indicators INTECH INSTRUMENTS.

OPERATION MANUAL. Carbon monoxide 0 to 1000 PPM, Temp. CO METER. Model : GCO-2008

RS-FX-N01 wind transmitter user's Guide (485type)

THE RAINBOW SCADA D-700

Modbus RTU Serial Communication User Manual

Simplified Digital Connectivity using MODBUS TCP/IP for iseries Instruments. MODBUS Master Device (PLC, PC, Data logger, etc)

Danfoss commercial compressors Secop compressors produced for Danfoss Bluetooth Gateway

PLC v s MultiSmart Comparison. V s

LC-5 Level Controller & Flow Monitor

An Optimum Solution for Telemetry of Distributed. Wells in South of Tehran

ICP PANEL-TEC PEX3000 II

TRACKER 240 SERIES. Load Cell and Weighing Indicators. A Precision Measurement Instrument with Outstanding Features

Transcription:

Telemetry & SCADA Handbook www.scan-data.com CHAPTER 2, DO I NEED SCADA OR TELEMETRY? 2.A SUMMARY: The terms SCADA and TELEMETRY both describe systems which transmit measurements and commands from one site to another using RTUs. The two terms often mean much the same thing. These systems transmit reports and commands to control industrial installations. ANNUNCIATOR systems are also often used to perform much the same functions. 2.B SCADA SYSTEMS: SCADA stands for Supervision, Control And Data Acquisition. The term has come to mean systems controlled by a central computer. For example, a PC computer in your office can run supervisory and SCADA software packages such as National Instrument's Lookout or other packages which communicate over an RS-232 port and an MDM-202A modem to a radio or cable system and out to your tank and pump RTUs. These continuously scanning supervisory systems are referred to in the industry as Mode-B systems. In our tank and pump example, the tank level, the pump condition (running or stopped), the flow rates and pressures, etc., are all now depicted in color graphics on your PC screen. You can start and stop any pump, for instance, by simply moving the cursor over to the 'START' or 'STOP' positions and pressing 'ENTER'. These supervisory systems are very capable and can automatically do a number of complex operations such as writing reports to a printer and/or to a disk drive, performing automatic control and alarm functions, etc. TSH Chapter 2, Page 1, rev.a Copyright 2004 ScanData

2.C TELEMETRY SYSTEMS: Telemetry, on the other hand, has come to mean systems where you gather measurement signals at one site and repeat them out in the same form at another site where you connect them to meters and switches. The inputs from the remote site can be connected to an annunciator panel, for instance, where meters and lights indicate what is happening at the remote site. These are referred to in the industry as signal multiplexer or Mode-C systems. For example, you can input a 4-20 ma level signal at your tank site RTU and get the same 4-20 ma signal out from the RTU in your office. Connecting this signal to a meter will allow you to continuously read the remote level on the meter. You can also flip a switch in your office which outputs a relay closure at the remote pump site RTU, which in turn starts or stops the pump. The simplest example of a Mode-C signal multiplexing system is where two RTUs communicate with each other over cable or radio. All analog and digital signals input at one RTU are automatically output at the other RTU. How many signals can a system like this transmit? As many as there are input and output circuits at each RTU. In these systems one RTU is the master and the other is the slave. The master RTU continuously polls the slave RTU which immediately answers each poll. With a test set such as the ScanData TTS you can hear the polling and answering tone 'chirps' at both the master and the slave RTU. Should the cable or radio communication link be broken, you will only hear the outgoing poll at the master, and no RTU answer. At the slave RTU you will hear nothing. A second example of a Mode-C signal multiplexing system is where one master RTU communicates with two or more slave RTUs. In these systems, any analog or digital signal input at any point can be output at any other point. The master RTU can re-direct any signal from any RTU to any other RTU. Signals can also be simultaneously output at more than one RTU or at the master. TSH Chapter 2, Page 2, rev.a Copyright 2004 ScanData

2.D ANNUNCIATOR SYSTEMS: An annunciator panel is one where the incoming signals from the field instrumentation are displayed on meters (analog signals) or by colored lights or by lighting up glass panels with text on them (digital signals). These annunciator panels are still installed, all over the world, in spite of the convenience of more modern computer screen presentations. Immense annunciator panels are often installed in power generating stations, breweries and elsewhere. A multitude of meters, switches, rheostats and indicating lamps and panels allow the operator to control the installation. Miles of cables connect between the panels and the outlying sensors and actuators. Nowadays, to lessen cable costs, signal multiplexing telemetry (Mode-C) is often used to carry the analog and digital signals to and from the field. In addition to savings on cable costs, signal multiplexing telemetry carries another advantage: All signals are digitized so that future connections to a computer system is very simple. 2.E A LITTLE COMPUTER HISTORY: Before the Personal Computer revolution, computers were very expensive and were often run by a special Data Processing (DP) department, housed in special air conditioned quarters. The DP department often had their own way of doing things. Nobody outside the department really understood what they were doing and nobody dared question what they did (or the money they spent). The Personal Computer revolution, as we all know, changed all that as it is continuing to change our lives. Our future will be changed by Personal Computers in ways we cannot yet imagine. In the beginning there was resistance to the widespread use of computers in many companies, both by the DP department that did not want to loose control and by many operators who where intimidated by the keyboard. Today, you can hardly run an operation, no matter how small, without the use of one or more laptops or PCs. Most devices used in measurement and control now contain computers (or microprocessors) in themselves. Many pressure, temperature, level and flow sensors do. Most all RTUs and PLCs do. You now need laptop computers to program most PLCs. Lets face it. PCs and laptops are here to stay. They make our work easier. Today, there is no reason to install any system that does not use PCs in some form or one that is at least PC compatible. Mode-B systems use PCs as central station. Mode-C systems should communicate in a manner which can be understood and intercepted by PCs. TSH Chapter 2, Page 3, rev.a Copyright 2004 ScanData

2.F WHAT SYSTEM SHOULD I CHOOSE? This chapter is serving as an introduction to these systems. The following chapters of this Handbook deals in detail with the design, installation and operation of Telemetry and SCADA systems. 2.G YOU NEED COMPATIBILITY. The one major requirement of any system is this one: Each component of the system should be able to communicate with any other component. For example: You can buy a light bulb in Chicago, a lamp in New York and when you screw the bulb into the lamp and plug it in into an electric power socket in Los Angles you can be certain that it will work. TSH Chapter 2, Page 4, rev.a Copyright 2004 ScanData

There are horror stories. A small town in Lapland in northern Sweden had 250 volts DC wired into all the houses. Well, there are not many manufacturers of 250 volt DC light bulbs left in the world, and the citizens of this town have to pay dearly for their light bulbs. And their radios. And their refrigerators (if they ever need them up there). Even worse. A manufacturer of RTUs had his own, secret protocol that his RTUs used. This locked his customers in to using his central stations and software. Good for the manufacturer but not so good for the customer. Suddenly the manufacturer ceased manufacturing these RTUs and started manufacturing another type of RTU with another, even more secret protocol. The old protocol was no longer supported. Where does that leave the customer who bought the old protocol RTUs? Completely without support. The best he can do is to scrap these old RTUs. One wonders what line that company's salesman takes when he visits that customer. There are also instances where manufacturers of RTUs with proprietary protocols have ceased manufacturing RTUs or simply gone out of business. Most reputable manufacturers nowadays manufacture RTUs and PLCs with 'open' protocols. Gould Modbus and CAP (Compressed ASCII Protocol) are emerging as the leaders in easy to use open protocols. 'Open' protocols mean protocols that are not secret and are well documented so that any programmer can write central station programs for the RTUs and PLCs purchased. WHERE CAN I GET MORE INFORMATION? The following descriptions, pertinent to this chapter, are included in the DESCRIPT directory on the SCADAtech(TM) CD: pri-0901.pdf gui-0980.pdf Design Guide and Price List. How to design SCADA and Telemetry systems. app-1104.pdf How to send multiple analog and digital signals An easy way to get the latest and most recently updated versions of these descriptions is to go on our WEB site: www.scan-data.com When you are there, click on the blue button near the bottom of the WEB page that says Technical Information. Then click on the description # you need. TSH Chapter 2, Page 5, rev.a Copyright 2004 ScanData