IEEE 802.3cg MDI connector Limitations. Amrik Bains - Cisco Systems George Curtis - Cisco Systems Ed Kliewer - Cisco Systems

Similar documents
Cat.8 Shielded Field Termination Plug Description

IEEE P802.3cg 10 Mb/s Single Twisted Pair Ethernet Task Force (10SPE)

Industrial style Single Pair Ethernet connector acc. to IEC

Ethernet and PoE Operation Over Single Pair Twisted-Pair Copper Cabling (SPE) Chris DiMinico AEM Technical Sales Test and Measurement

Recent Changes in the Physical Layer (Chapter 8) for DeviceNet and EtherNet/IP

Recent Changes to the Physical Layer (Chapter 8) for DeviceNet and EtherNet/IP Brad Woodman Molex

Cat.8 Shielded Keystone Jack Description

Balanced single-pair cabling channel specifications

R&Mfreenet Advanced Cat 6A Shielded Connection Module

R&Mfreenet Advanced Cat 6 A Unshielded Connection Module

Data sheet. 25Gmodul. Illustrations P/N 130B11-25-E EAN Product specification. Page 1/ Dimensional drawing

Clause 86 MDI Optical Pin Layout and Connector. Paul Kolesar, CommScope Sharon Lutz, USConec IEEE P802.3ba January 2009

Feasibility Framework for 10SPE Automotive

Data sheet C6 A modul 90 jack

Cisco ONS CL Shelf Assembly Hardware

Category 8 paves the way for IEEE 40GBASE-T. David Hughes RCDD/DCDC/NTS Senior Technical Manager MEA CommScope

Updated Test Data for Channels based on Proposed Category 8.2 Connectivity IEC Augmented RJ45

Technical Committee. Addendum to ATM Physical Medium Dependent Interface Specification for 155 Mb/s Over Twisted Pair Cable (af-phy-0015.

Product information Patch Cord Cat. 6A, S/FTP, 4P, LSFRZH, gray, RJ45/s- RJ45/s, 1.0 m

Data sheet C6 A modul 1 port 180 M AP pure white

Single-pair cabling channel specifications

Power Input Assignment Power1 12VDC DC Jack VDC Power2 - Power Ground

ST-POE-2P-WTP. IP67-Rated POE Extender

5/8-Port Industrial Fast Ethernet Switch ISW-500/ISW-800. User's Manual

ex-s1110-xt Gigabit Ethernet Extenders

The module for the highest standards, guarantees the best performance in the 10 Gigabit Ethernet cabling.

WP3x00 MK ll Controller. control systems. All control functions are integrated. Integrated realtime grid measurement

Hardened 10/100Base-TX IEEE802.3at PoE PSE Ethernet Extender

Modular Jack Slimline Product Presentation

Data sheet C6 A modul 2 port 180 M UP pure white

TIA-1005-A M.I.C.E Rated Product Selection Guide

HCI 2017 Products Catalogue

40 Gigabit over copper - Thorsten Punke Marketing Manager ANZ TE Connectivity

Solid State Battery Fuel Gauge

Overview of the Cisco Wireless Gateway for LoRaWAN

CONEC Industrial Ethernet Circular Sealed RJ45 Connector System consists of a RJ45 Plug Kit, a Receptacle Kit and a Protective Cover Assembly.

NGBASE-T Cabling Requirements

MF727xS INDUSTRIAL 10/100BASE-TX TO 100BASE-FX MEDIA CONVERTER. Installation Guide

The PXI Modular Instrumentation Architecture

Quick Start Guide. Installation. User s Manual 1

PSI-MODEM-SHDSL/PB. Broadband PROFIBUS extender, SHDSL PROFIBUS leased line modem. Data sheet _en_03. 1 Description. 1.

Power Input Assignment Power1 12VDC DC Jack VDC Power2 - Power Ground

10SPE - 10 Mb/s Single Twisted Pair Ethernet Study Group Reflections of AdHoc Chair & System Vendor November 2016

YT-RJ45 YT-RJ45-CPE YT-RJ45-JSX RJ45-01 female socket. RJ45-01 direct ethernet port

LevelOne. User s Guide EHU-0507T EHU-0507TB EHU-0807T EHU-0907TB. 5/8/9 Port PalmCon 10M HUB

USER GUIDE. AXIS T8120 Midspan 15 W 1-port ENGLISH

Industrial Ethernet Switch. Signamax Connectivity Systems. Industrial Ethernet Switch. Model A Series. User s Guide

INDUSTRIAL 1000BASE-T TO 1000BASE-X MEDIA CONVERTERS. KCD-400 Series. Installation Guide

CSRJ456K. White CSC624PP CSRJ456KB CSRJ456K90

Cable into the Future: Industrial Ethernet with 10 Gbps

8 10/100/1000T Industrial Switch. User Manual MS655208(X)

WP4200 Platform. control systems. CPU module for WP42xx Systems and Concepts. High performing controller for all types of turbines

USB 2.0 RG2304GE-LAN. 4-Port USB 2.0 Gigabit Ethernet LAN Extender System. User Guide

Industrial 5-Port Fast Ethernet Switches with SFP Slot and optional 4 PoE PSE Ports. Basic Model: KSD-541 PoE Model: KSD-541-P. Installation Guide

WP100 Platform. control systems. CPU module for small and medium sized wind turbines. Safe operation in harsh environments

FREQUENTLY ASKED QUESTIONS (FAQs)

M12x1 Circular Connectors

New Standardized Cabling Options for NBASE-T Devices

PCS PATCH CORD SOLUTIONS PATCH CORD SOLUTIONS

IEEE P802.3cg 10Mb/s Single Pair Ethernet: A guide

VARAN Splitter Module VSV 041

Introduction to LAN Topologies Cabling. 2000, Cisco Systems, Inc. 3-1

AMP NETCONNECT EtherSeal System Bringing Ethernet and Structured Cabling to Non-Office Environments.

MAC & Scope Background for 802.3cg, Priority & PLCA

RJ point five CONNECTOR SYSTEM

Cables and Connectors

exp-s1110pe PoE+ Gigabit Ethernet Extenders

Power Over Ethernet with Panduit Copper Cabling. How To Create More Meaningful Connections With The Highest Performing Infrastructure

Telegärtner Point of View

ISO/IEC SC25 WG3. Who are they & what can they do for 802.3cg? Alan Flatman. Principal Consultant LAN Technologies.

Lantech I(P)GS-0008B. 8 10/100/1000T (PoE at/af) Industrial Unmanaged Ethernet Switch I(P)ES-0008B

Cabling Infrastructure

USB 2.0 DIGI-USB2 1-Port USB m Category 5e/6/6a/7 Extender Set with Flexible Power. User Manual. Revision

QUICK START GUIDE FOR DEMONSTRATION CIRCUIT 1420A 12-PORT IEEE 802.3AT PSE INTEGRATED CONNECTOR MODULE (PSE-ICM)

5 10/100TX w/ 4 PoE Injector Industrial Switch. User Manual

Hardened PoE Ethernet Switch

Using RJ45 Category 7 Cabling for 2 Lane, 1 and 2.5Gbps Serial Data Transmission

Industrial 5-Port Fast Ethernet Switches. with SFP Slot and optional 4 PoE PSE Ports. Basic Model: KSD-541. PoE Model: KSD-541-HP. Installation Guide

PASS4TEST. IT Certification Guaranteed, The Easy Way! We offer free update service for one year

IEEE P802.3cg 10BASE-T1S Increased Transmit Voltage

Product information 19" 3U Global Patch Panel 48xRJ45/u, Cat. 6, partly populated R302361

INSTALLATION INSTRUCTIONS NI TB-2630B Terminal Block for the NI PXI-2530B. Contents. Introduction

Ethernet Media. Technical Data. Cable Spools 2. Cordsets & Patchcords 5. Patchcords & Field Attachables 12

HDMI IN HDMI IN POWER POWER INDICATOR RJ45 HDMI OUTPUT POWER POWER INDICATOR LINK ACTIVITY POWER INDICATOR

Korenix JetNet 3000 Series Industrial Entry-Level Ethernet Rail Switch User s Manual

NBASE-T Downshift: Optimization of 2.5Gb/s and 5Gb/s Ethernet Data Rates Over Cat5e/Cat6 Cabling

ISO/IEC TR Guidance on 40GBASE-T T Cabling

KPW-T2P25. PoE Splitter. Industrial IEEE 802.3at High Power. User s Manual -1- DOC

Industrial PoE Media Converter

Cable Sharing: An ANSI & ISO Recognized Solution for High Density, Low-Speed Applications. Robert Y. Faber Jr., RCDD/NTS.

TE100-DX16R/DX24R/DX32R 16/24/32 Ports Ethernet/Fast Ethernet Dual-Speed Stackable Hubs User s Guide

Datasheet: CableIQ Qualification Tester - The network tech s vision into cabling bandwidth.

CLIMATIX STEQ, STCM DATASHEET FOR CONTROLLING, SWITCHING AND MONITORING FUNCTIONS. POWER SUPPLY RELAY OUTPUTS. Power supply. 4.

Proposed Objectives. IEEE Mbps Single Pair Ethernet Study Group. George Zimmerman (Chair) CME Consulting, Inc. 10/28/16.

Jamey Calloway, RCDD Product Management Specialist Optical Cable Corporation

Mid-span 802.3af PoE Injector. Installation Guide KPOE-100

FL SWITCH 8TX. Extract from the online catalog. Discontinued item. Order No.:

Hardened Web-Smart PoE & High Power PoE Ethernet Switch

Extension module for BACnet over Ethernet / IP and graphic Web functions

IES User Manual. 6 GE + 2 SFP Unmanaged Switch -20 to 60C, DIN-rail. v

Transcription:

IEEE 802.3cg MDI connector Limitations Amrik Bains - Cisco Systems George Curtis - Cisco Systems Ed Kliewer - Cisco Systems 1

IEEE 802.3cg D2p2 clauses 146.8.1 and 147.9.1 specifies MDI connectors that may be used for Single Pair Balanced cabling meeting the requirements of IEC 63171-1 (MICE 1 environments) or IEC 61076-3 (MICE 2/3 environments). The plug connector is used on the balanced cabling and MDI Jack connector on the PHY (end device for example a switch) Current IEC 63171-1 and IEC-61076-3 do not cover expected use cases 2

IEC 63171-1 specified connector size does not support 18 AWG cable. 18AWG is a significant use case for installed and new cabling. Requiring a patch panel or cable adapter to support 18AWG is a significant burden to system vendors and users (D2p2 comment #279) IEC 63171-1 does not support MICE 2 Industry common practice uses the same connector for MICE 1 and MICE 2. Using a different connector in these environments is a significant burden to system vendors and users (D2p2 comment #280) No PHYSICAL interoperability (mating surface and pin pitch are different) between IEC 63171 and IEC 61076 and other configurations such as 1x2, 2x2 etc. (D2p2 comment #281) 3

Support same connector for 18 26 AWG capable of high port density on a switch Current 48 port Switch (1RU) using 4 Pair Stacked RJ45 13 Future 96 port Switch (1RU) using Single Pair Stacked connectors 22 AWG to 26 AWG Same switch using every second port with 18 AWG, but same connector/pin pitch 4

Current Ethernet equipment does not use full MICE 1/2/3 requirements BUT uses subset of feature based on the application (M1, I1, C1, E1) OR (M1, I2, C1, E2). (M3, I3, C3, E3) is a very small use case for high industrial applications Current Ethernet equipment uses IP66/IP67 for I in MICE MICE 1/2/3 should have same mating surfaces and pin pitch. External body of the connect can be adopted to meet M3, I3, C3, E3 for Industrial applications Examples IP67-rated weatherproof stranded STP CAT6 cable assembly provides watertight industrial Ethernet connectivity in harsh environments 5

Electrical requirements - Insertion Loss/Return etc, defined in clause 146.8 Mechanical Dimensions pin pitch and mating surfaces Electromagnetic Compatibility EMC Emissions and EMC Immunity o Connector require non-shield (E1 and E2) and shielded cable (E1/E2/E3) options o All other requirements are at system level based on local, state and country requirements Connector should allow higher current capacity (2A) and electrical performance for up to 10G beyond 802.3cg requirements for the future Ability to terminate connector/cable in the field (like RJ45 with simple tool) Latch/locking mechanisms 6

Re-use of the switches and end devices across different applications Lower cost due to larger combined volumes Avoid patch panels and special patch cables Avoid different cable/connector termination schemes 7

Proposed text for the same paragraph in IEEE 802.3cg draft 2.2 Clause 146.8.1 (page 153 line 14) "Connectors meeting the requirements of IEC 63171-1 or IEC 61076-3-125 may be used as the mechanical interface to the balanced cabling. The plug connector is used on the balanced cabling and the MDI jack connector on the PHY. The IEC 63171-1 plug and jack are depicted (for informational use only) in Figure 146-26 and Figure 146-27 respectively and the mating interface is depicted in Figure 146-30. The IEC 61076-3-125 plug and jack are depicted (for informational use only) in Figure 146-28 and Figure 146-29 respectively and the mating interface is depicted in Figure 146-31. The assignment of PMA signals to connector contacts for PHYs are given in Table xx. These two connectors may be used, with adaptations if needed, for electromagnetic classifications for the link segment given in Table 146 7. These connectors should support link segment DCR characteristics for 18AWG to 26AWG in Table 146B-1. NOTE: Add 26 AWG to table 146B-1. 8

Proposed text for the same paragraph in IEEE 802.3cg draft 2.2 Clause 147.9.1 (page 198, line 51) "Connectors meeting the requirements of IEC 63171-1 (commercial building environments) or IEC 61076-3-125 (light industrial and industrial environments) may be used as the mechanical interface to the balanced cabling. The plug connector is used on the balanced cabling and the MDI jack connector on the PHY. The IEC 63171-1 plug and jack are depicted (for informational use only) in Figure 147-21 and Figure 147-22 respectively and the mating interface is depicted in Figure 147-25. The IEC 61076-3-125 plug and jack are depicted (for informational use only) in Figure 147-23 and Figure 147-24 respectively and the mating interface is depicted in Figure 147-26. The assignment of PMA signals to connector contacts for PHYs are given in Table xx. These connectors should support link segment DCR characteristics for 18AWG to 26AWG in Table 146B-1. NOTE: Add 26 AWG to table 146B-1. 9

10

IEEE 802.3cg D2p2 clauses 146.8.1 and 147.9.1 specified MDI connectors do not meet wide market adoption Further work is required to address 10SPE use cases. 11