RADCOM s Platform Specifications. Valid from Version 7.10

Similar documents
LVN5200A-R2, rev. 1, Hardware Installation Guide

Installation Job Aid for Ethernet Routing Switch 3600 Series

user manual AMOS-2000 Universal Compact, Chassis System, Supporting Nano-ITX Embedded Boards Revision

AMS Series. Fanless System

4170 POS System Installation Guide

Dell Vostro 320 Setup and Features Information Tech Sheet

Industrial PC IPC191V2. General Operating, Maintenance and Installation Manual. Hardware Platform Protocol Converter

Manual Version: V1.00. Video Decoder Quick Guide

G-MAX TM. ATX Series User s Manual

iops-18 User Manual 2013 Oct V1 IBASE Technology Inc.

Installation Job Aid for VSP 4850GTS

Installation Job Aid for VSP 4450GTX-HT- PWR+

JanusRAID SA-6692J Hardware User Manual

Lightspeed Advanced Reporting Bottle Rocket Hardware Installation Guide

easyraid Q24P2-U4R4 Hardware Manual

MIC-3001/8. 3U/4U CompactPCI Enclosure for Rack Mounting. User Manual

EVO-TM2A EVO-TM2B Touch Screen Monitor

Manual AMS ibase

Dell MD1280 Storage Enclosure Getting Started Guide

Omnitron Systems Technology, Inc. 1. iconverter. 19-Module Managed Power Chassis User s Manual

ALLPLEX Access Easy Master Controller APC-AEMC-SVR. Quick Installation Guide

Industrial PC IPC191C2. General Operating, Maintenance and Installation Manual. Hardware Platform Protocol Converter

Installation Job Aid for Ethernet Routing Switch 5900 Series

MultiVOIP SIP Gateways

iconverter 2-Module Power Chassis

MIC-3001/8. 3U/4U CompactPCI. Enclosure for Rackmounting

Handbuch. DAVIDE Mini PC GRAFENTHAL

2190 POS System User Guide

Dell Storage Center. Getting Started Guide. SCv2000 and SCv2020 Storage System. Regulatory Model: E09J, E10J Regulatory Type: E09J001, E10J001

User Manual RKD-KVM-20 / RKDS-KVM-20. WRKD-KVM-19 / WRKDS-KVM-19 Series. Series

Toll Free: Tel: Fax:

EVO-TP Hardware System

Network Camera. Quick Guide DC-B1203X. Powered by

Thank you for selecting UTC RETAIL s innovative Model 1170 Point of Sale solution!

ftserver 3300 Service Bulletin

Upgrading and Servicing Guide

Sivy SA-4327S Hardware User Manual

Rack Mount LCD KVM Assembly. Installer/User Guide

Dell Networking S4810 Open Networking (ON) Getting Started Guide

AX3000 Platine Terminal Ethernet TCP/IP

Upgrading and Servicing Guide

Table of Contents Quick Install Guide page Introduction Safety Rack System Precautions ESD Precautions...

AX3000 Platine Terminal Ethernet TCP/IP

Dell Latitude E5410/E5510

Upgrading and Servicing Guide

dedicated KVM switch and rackmount screen technology User Manual CV-1201D DVI-D KVM Designed and manufactured by Austin Hughes

Installing the IPS 4345 and IPS 4360

2100 POS System User Guide

16-SLOT IN-BAND MANAGEMENT CHASSIS

8806 Series. 15 Multi-functional Touch Panel PC. Quick Reference Guide

The power behind competitiveness. Delta Infrasuite Power Management. Power Distribution Unit. User Manual.

Summit Virtual Chassis Design and Installation Guide

Vision800 Video Wall Controller. User Manual

Industrial PC IPC191V3 (Linux OS) IPC191V3WIN (Windows OS) General Operating, Maintenance and Installation Manual

MAINTENANCE MANUAL. EDACS REDUNDANT POWER SUPPLY SYSTEM 350A1441P1 and P2 POWER MODULE CHASSIS 350A1441P3, P4, AND P5 POWER MODULES TABLE OF CONTENTS

Junos WebApp Secure 5.0 Hardware Guide

All company and product names are or Registered Trademarks of their respective owners.

Codian IP VCR IP VCR 2200 Series

Network Public Address Server

Cisco MCS 7825-I1 Unified CallManager Appliance

AEROTRAK PORTABLE AIRBORNE PARTICLE COUNTER MODEL 9310/9350/9510/9550/9500 QUICK START GUIDE

Express5800/320La System Release Notes

USER MANUAL. Uninterruptible Power Supply Line-interactive VCL Series UPS VA. GE Critical Power

Installation Manual of DS-9600NI-H8 DS-9600NI-H8. Installation Manual UD.7L0202A1730B01

ADC7520 SERIES. 1600W Battery Chargers and Power Supplies

MC 11 EB-2 Power supply cabinet with external bus, AC version

NVR-CV. Network Video Recorder Hot-Swappable Tray for 3.5 HDD x 4 or 2.5 HDD x 4 Gigabit Ethernet x 2 COM x 2, USB2.0 x 6. VGA x 1, DVI-D x 1

RACK-220 CHASSIS USER S MANUAL

Dell Vostro 1014 and 1015 Setup and Features Information Tech Sheet

HP ProLiant DL380 Generation 3 Server Maintenance and Service Guide. May 2003 (Third Edition) Part Number

Agilent 70612B K18 Switch Matrix

Dell Precision Workstation T7500/T7500n Setup and Features Information

Upgrading and Servicing Guide

TA Series User s Manual

LevelOne. KVM-0115/KVM / 17-inch LCD KVM Rack Console. User Manual. Version

HP UPS R/T3000 ERM. Overview. Precautions. Installation Instructions

VelaSync HIGH-SPEED TIME SERVER. Quick Reference Guide

Modular 8-Port Mid-span Power over Ethernet Injector

USER MANUAL VERSION V1.0 AUG MiniPOS Hardware System

TRC-190 User s Manual

Installation and Operating instructions for 19 Inch Rack Mount Industrial PC C5102 from -0060

Hardware Reference Guide For Thin Clients

LifeSize ClearSea Installation Guide August 2012

NOTE: Use the System Setup program to view microprocessor information. For more information, see "Using the System Setup Program."

Industrial 5-Port Fast Ethernet Switches with SFP Slot and optional 4 PoE PSE Ports. Basic Model: KSD-541 PoE Model: KSD-541-P. Installation Guide

FCC COMPLICANCE STATEMENT

USP-070-B08 USP-104-B10, USP-104-M10 USP-156-B10

USER MANUAL. VERSION V1.0 March Saturn Plus

Host Controller: HST-4002

Installation and Maintenance

CISCO MEDIA CONVERGENCE SERVER 7825-I1

Perle MCR200 Installation Guide

IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS

Quick Start Turning on the Tablet PC for the First Time

PIX 515/515E. PIX 515/515E Product Overview CHAPTER

INSTRUCTION MANUAL RA 55 RACK ADAPTER RACK ADAPTER FOR MST SERIES POWER MODULES

User s Manual. PCI Bus Expansion Chassis Short x 2Slots ECH(PCI)BE-H2B CONTEC CO.,LTD. PC-HELPER. Long x 2Slots ECH(PCI)BE-F2B

User Manual RecoMedia Presentation made easy

S-Band Redundant LNA Systems

VTPC190V / VS / VDC / VSDC

Transcription:

Valid from Version 7.10 RADCOM Ltd., November 2006

IP Notices: 2006 RADCOM Ltd. All rights reserved. RADCOM is a trademark of RADCOM Ltd. in Israel and/or other countries. Microsoft Windows and Microsoft Windows NT are registered trademarks or of Microsoft Corporation in the US and/ or other countries. All other brand and product names referred to herein are either registered or unregistered trademarks or service marks belonging to their respective owners. This documentation contains proprietary information of RADCOM Ltd. and RADCOM Equipment Inc. Such information is hereby supplied solely for the purpose of informing explicitly and properly authorized persons of the documentation on the operation of RADCOM equipment. Without the express prior written permission of RADCOM Ltd. and RADCOM Equipment Inc., no part of the contents hereof may be used for any other purpose, disclosed to persons or firms outside the recipient company, or reproduced by any means. The text and drawings herein are for the purpose of illustration and reference only. The specifications on which they are based are subject to change without notice. Publication Date: November 2006

Table of Contents Safety Precautions 2 Lithium Battery Warning 3 Installing in a Rack Mount (R1000, R4000 and R70) 3 Site Requirements 4 Performer R1000 Unit 5 Specifications: R1000, Rack-mount 2U, Performer/Probe Server 5 Performer P1000 Unit 7 Specifications: P1000, Portable Performer Server 7 Performer R4000 Unit 10 Specifications: R4000, Rack-mount 5U, Probe 10 R70 Probe 14 Specifications: R70, Rack-mount 2U 14

Safety Precautions NOTE Adhere to the following safety precautions to reduce the risk of electric shock or fire. All servicing of the Performer and R70 units should be undertaken only by qualified service personnel. There are no user serviceable parts inside the Performer. Contact your local representative for information concerning repair. The Performer and R70 operate with 100V-240V AC. Connect the Performer/R70 to a wall power socket with a voltage of 100V- 240V AC only. Do not plug in, turn on or attempt to operate an obviously damaged unit. Contact your local representative to arrange the return of a damaged unit. Permanent damage may be caused to the Performer/R70 if the stated clearance requirements on the side and underneath the Performer are not met. Do not operate the unit if the maximum ambient temperature exceeds 40º C (104 F). Do not attempt to open the unit s case. Consult your representative about any changes to be made to the hardware configuration. Maximum Load Permitted The R1000 and P1000 have 4 PCI card slots. Slots 1, 2 and 3 are located on the left side of the backplane, and the fourth (PCI 4) is located on other side of the backplane, above the SBC. The maximum load for PCIs 1, 2 and 3 is 35 watts each. The PCI 4 slot is intended for a half-size PCI card. When the R1000 or P1000 include a Sync Card configuration, the Sync Card is installed in PCI slot 4. The maximum load for PCI 4 is 5W.

3 The R4000 has four SBC segments. Each segment has 3 PCI slots (PCI slots 1, 2 and 3). The maximum load of PCI 1 and 2 is 35W each. The third slot (PCI 3) is intended for a half-size PCI card. When the R4000 includes a Sync Card configuration, the Sync Card can be installed in any segment, but is usually installed in slot 3. The R70 can accommodate up to three LIMs of any type. Lithium Battery Warning DANGER Risk of explosion if battery is replaced by an incorrect type. Before battery replacement, turn off the unit and disconnect the power cord from the unit. Dispose of used batteries according to instructions. Lithium Battery Warning The SBC includes a lithium battery. There is danger of explosion if the battery is incorrectly replaced. If you have to replace the lithium battery, replace only with the same or equivalent type of battery. Recycling Lithium Batteries! CAUTION Do not handle damaged or leaking the lithium batteries. You can help preserve the environment by returning your used batteries to your nearest collection and recycling location. For more information regarding rechargeable batteries, visit http://www.rbrc.org/. Installing in a Rack Mount (R1000, R4000 and R70) Install the Performer/R70 on rack mount slides and fasten the unit s rack mount brackets with screws to the cabinet. Make sure that you have free access to the power cord plug (to plug in and unplug the unit). Make sure that the rack is ventilated

4 Site Requirements Before unpacking your Performer/R70, verify compliance with the following conditions:! CAUTION Permanent damage may be caused to the Performer/R70 if the following requirements are not met: Power Your Performer/R70 should be installed within 1.5 m (5 ft.) of an easily-accessible grounded AC outlet capable of supplying 100V-240V AC ±10%. Side and Bottom Clearance External Environment Allow at least 10 cm (4 inches) clearance on each side of the Performer/R70 for proper ventilation. The Performer/R70 should be placed on a hard, flat surface in order to avoid obstruction of the ventilation slits. Normal conditions: Temperature: 22º C +/- 2º C Humidity: 50% relative humidity +/- 5% Extreme conditions: Temperature: 0-45º C Relative humidity: 10-90% Absolute humidity: less than 25g/m 3 Dust: up to 75 mg/m 3 AC Voltage Source Voltage: Nominal Value 100V, 220V Range of Variation 90V-264V Frequency: Nominal Value 50Hz Range of Variation 48Hz-52Hz Form Factor: Nominal Value 1.11 Range of Variation 1.08-1.14 Harmonic Distortion: max. 5% DC Voltage Source Power: Distribution cabinet supplying (nominal) 48V DC Range of variation 42V to 56V

5 Performer R1000 Unit Specifications: R1000, Rack-mount 2U, Performer/Probe Server HW: Pentium 4, 2.4Ghz; 1 GB DDR, 266 MHz; 80 GB Hard disk Number of FEPs: Up to 2, plus Sync card Dimensions: w x d x h: 440 x 470 x 89 mm (17.5 x 18.7 x 3.5 in). Weight: 9.2 Kg (20.3 lb) Power: 100V 240V AC auto-range, Maximum 300W. External Environment Normal conditions: Temperature: 22º C +/- 2º C Humidity: 50% relative humidity +/- 5% Extreme conditions: Temperature: 0-45º C Relative humidity: 10-90% Absolute humidity: less than 25g/m 3 Dust: up to 75 mg/m 3 Altitude: 12,000 feet MTBF 38,000 hours The back and front panels of the Performer Rack Mount R1000 unit appear as follows: Back Panel COM1 Slot for Sync Card 2 LIMs Power Switch Power Supply Ethernet Management Port Mouse/Keyboard Fan Ethernet SIPSim Port VGA Figure 1: Performer R1000; back panel

6 Front Panel Hard disk drive activity Power on/off Front panel door Keyboard/ mouse USB Figure 2: Performer R1000; front panel Inside the front panel door are the red reset button, the yellow shutdown button, the black power switch and the CD-ROM. Use the black power switch to turn the Performer unit on. The red reset button resets the Performer, only use this button if the system freezes. Use the yellow shutdown button to execute a proper software shut down and to turn off the Performer properly. You should only use the yellow button to turn off the Performer unit. To run the R1000: 1. Connect the power cable. 2. Turn on the switch at the back of the unit. 3. Open the front door panel. 4. Press the black button.

7 Performer P1000 Unit Specifications: P1000, Portable Performer Server HW: Pentium 4, 2.4Ghz; 1 GB DDR, 266 MHz; 80 GB Hard disk Number of FEPs: Up to 3, plus Sync card Dimensions: w x d x h: 340 x 420 x 116 mm (13.4 x 16.5 x 4.6 in). Weight: 8.2 Kg (18.0 lb) Power: 100V 240V AC auto-range, Maximum 300W. External Environment Normal conditions: Temperature: 22º C +/- 2º C Humidity: 50% relative humidity +/- 5% Extreme conditions: Temperature: 0-45º C Relative humidity: 10-90% Absolute humidity: less than 25g/m 3 Dust: up to 75 mg/m 3 Altitude: 12,000 feet MTBF 38,000 hours The P1000 unit is the portable version of the Performer. You can position this both in a horizontal position and a vertical position. The P1000 unit comes with a unique carrying case with space for the LIMs and appropriate cables, which you can order separately.

8 Sync Card Reset Power Switch Software shutdown HDD LED CD-Rom R/W 3 LIMs Handles Ethernet Management Port Ethernet SIPSim Port VGA Keyboard/mouse 2 USB ports Figure 3: P1000 Horizontal, front view Power Supply Power Cable plug Fans Figure 4: P1000 Horizontal Rear View

9 Figure 5: P1000, Front View, vertical

10 Performer R4000 Unit Specifications: R4000, Rack-mount 5U, Probe Consists of 4 independent segments, each including: HW: Pentium 4, 2.4Ghz; 1 GB DDR RAM, 266 MHz; 80 GB Hard disk; 7200 RPM Number of FEPs: Up to 8, plus four Sync cards (one per segment) Dimensions: w x d x h = 430 x 680 x 220 mm (17 x 27 x 8.7 in) Weight: 30 Kg (66.25 lb) Power: 100V 240V AC auto-range, Maximum 1000W. Power dissipation 800 W Input power 100-260 VAC Installation Rack mount 19 (21 option) Mean Time Between Faliure: 18,000 hours Operating system: Microsoft Windows XP External Environment Normal conditions: Temperature: 22º C +/- 2º C Humidity: 50% relative humidity +/- 5% Extreme conditions: Temperature: 0-45º C Relative humidity: 10-90% Absolute humidity: less than 25g/m 3 Dust: up to 75 mg/m 3 Altitude: 12,000 feet MTBF 20,000 hours

11 The Performer R4000 unit consists of four Performer segments in one box. The back and front panels of the Performer R4000 Rack Mount unit appear as follows: Power Fan 1 Fan 2 Power LEDs for each segment HDD LEDs for each segment Temperature Power 1 and 2 (redundant) Figure 6: R4000 unit, front view 8 7 6 1 2 3 4 5 Figure 7: R4000 front view with door open

12 Number Explanation 1 Power supply for each segment 2 4 reset buttons (one for each segment) 3 Power button 4 Key 5 4 hard disks (and a spare one) 6 Future place for CD-ROM and USB 7 Momentary power switch for each segment 8 Power reset 8 7 1 6 5 2 3 4 Figure 8: Performer R4000 back view

13 Number Explanation 1 2 USB ports 2 2 LIMs for each segment 3 Power supply 4 Power switch 5 Ethernet Management Port 6 Ethernet SIPSim Port 7 VGA 8 Keyboard/mouse All of the above elements (apart from the power supply and power switch) appear for each segment.

14 R70 Probe Specifications: R70, Rack-mount 2U HW: RADCOM s proprietary embedded high-end solution Number of PIMs (plug-in modules): up to 4 Number of LIMs (line interface modules): up to 3 Synchronization methods supported: GPS, NTP and local synchronization Dimensions: w x d x h: 440 x 540 x 89 mm (17.5 x 21.3 x 3.5 in). Weight: 8 kg (17.6 lb) Power: 100V 240V AC auto-range, Maximum 180W; Single or dual power supply (redundancy mode). Power: 48V DC, Maximum 180W; Single or dual power supply (redundancy mode). External Environment Normal conditions: Temperature: 22º C +/- 2º C Humidity: 50% relative humidity +/- 5% Extreme conditions: Temperature: 0-55º C Relative humidity: 10-90% Absolute humidity: less than 25g/m 3 Dust: up to 75 mg/m 3 Altitude: 12,000 feet MTBF 38,000 hours single AC or DC power supply 43,000 hours dual AC or DC power supply To run the R70, connect the power cable and press the power button on the right side of the front panel. To shut off the R70, press the power button. Following are several views of the R70:

15 Figure 9: R70 Front View LIM #1 LIM #2 LIM #3 Power Figure 10: R70 with LIMs Displayed

16 1 2 3 10 8 9 4 7 5 6 Figure 11: R70 Rear View Number Explanation 1 Power Supply 2 Sync Out 3 Sync In 4 Sync Status LEDs 5 GPS Antenna Connector 6 GPS Status LEDs 7 Power Inlet 8 10/100/1000 Ethernet Management Port 9 RS-232 Port 10 Inter-Probe Connection Ports

17 PIMs Figure 12: R70 Inside View

US Office: RADCOM Equipment Inc. 6 Forest Avenue, Paramus, NJ 07652, USA Tel: (201) 518-0033 or 1-800-RADCOM-4, Fax: (201) 556-9030 E-mail: info@radcomusa.com Israel Office: RADCOM Ltd. 24 Raoul Wallenberg St., Tel Aviv, 69719, Israel Tel: 972-3-6455055, Fax: 972-3-6474681 E-mail: info@radcom.com China Office: RADCOM Ltd. Handerson Center, Office 506, Tower 3, 18 Jianguomennei Avenue, Beijing 1000005, P.R. China Tel: +86-10-65187723, Fax: +86-10-65187721 E-mail: china@radcom.com United Kingdom Office: RADCOM UK 2440 The Quadrant Aztec West, Almondsbury Bristol, BS32 4AQ England Tel: +44-145-487-8827, Fax: +44-145-487-8788 E-mail: uk@radcom.com Web Site: http://www.radcom.com RADCOM 2006