W3-M. Metal waterproof standalone access control/reader. User Manual

Similar documents
W3-H Waterproof Keypad/Reader/Controller

Waterproof. Keypad/Reader/Controller

BC Digital Keypad. User Manual

Standalone Keypad Access Control. User Manual. SS-TS2000 Size:120*80*25 mm

Standalone Keypad Access Control. User Manual. Please read the manual carefully before use this unit

CV-110SPK Standalone Keypad/Prox Access Control Installation Instructions

CM-110SK Standalone Keypad Installation Instructions

Single Door Standalone Access Control User Manual

DOLXFD1000B. Waterproof Access Control/Reader

CV-550SPK V2 Waterproof Keypad/Reader/Controller Installation Instructions

User Manual. PCKeypad Wireless Keypad

TEC100 USER/INSTALLER MANUAL V2.0 REV. 03/2018

VIDI-AC-2CS Access Controller/ Reader

F6-Fingerprint. Access Control/Reader. User Manual. F6 - Simplified Instruction. (Master Code) # (Factory default:1234) Enter the Programming Mode

Fingerprint Access Control F1. User Manual

RD-SR2 ACCESS SECURITY PRODUCTS LTD. Proximity Card Reader with Remote Control. User Manual

User Manual. Split access control with intelligent secured power supply.

Stand-alone Proximity Access Control

-DTZ001- Stand-Alone Proximity Access Control. User Manual

VIS-3200 / VIS-3201 User Manual

RBR-SB-KTZ001 LAR 2. User Manual

CC Series metal access control Manual

Digital Keypad Introduction

Installation and User Manual

EL-ST100 KEYPAD CONTROLLER

Partizan PAB-FC2. Fingerprint scan time Fingerprint identification time. <0.5 s < % <0.0198% Ingress protection rating

ACCESS CONTROL SYSTEM

Metal Standalone Keypad Access Control S100

DG-800 Stand-Alone Proximity Reader Instruction Manual

HSY-S209 EM Metal waterproof access control system User Manual

Instruction Manual. Vogue. Security. Technology. Innovation 2013-V01

REX F-0-9 Standalone or Access Controller

BHD-8000 Access Control Keypad and Card Reader. Wiring Diagram

SL2000E. Status Output. Electronic Code Lock. Features. Input. Exit Button Input. Introduction. Door Contact Input. Functional Description.

EZTAG3 PROXIMITY AND KEYPAD DOOR ENTRY

KP2000E/EM Series Style Keypad

1. Product Specification

EZTAG3 PROXIMITY AND KEYPAD DOOR ENTRY

genesis TECHNICAL MANUAL Two-Door Controller GEN-045

FTK5 PROXIMITY KEYPAD

AC-115 Compact Networked Single-Door Controller Hardware Installation and Programming

CP150B Vandal & Weather Resistant Keypad Security Systems

GV-Card Reader. User s Manual

Specifications: Features:

INSTALLATION INSTRUCTIONS 920P EntryCheck TM

Wiring Diagram and Programming Instructions for MAW6 Digital Keypad and Proximity Card/F reader

CV-945 Stand-Alone Biometric Reader. Installation Instructions

Finger Vein Access Control device Quick Start Guide Version: 1.0 Date: June USB slot. USB slot

VANDAL RESISTANT BACK-LIT WEATHERPROOF ACCESS CONTROL KEYPAD

ACTsmart2 Product Range Operating and Installation Instructions

_ Access control SISTEMAS DE SEGURIDAD

Compact Keypad. ins /02/2010. Exit button (push to make) 12V DC release current rating must be less than 1A.

GV-RK1352 and GV-R1352 Card Reader

INSTALLATION INSTRUCTIONS 920 EntryCheck TM

Section 1 General Description. Section 3 How to Program Keypad. Section 2 Installation. CM-120TX Wireless Digital Keypads Installation Instructions

Installing Keypad and Backplate

GUARD CENTURION OPERATING INSTRUCTIONS THE AUTOMATIC CHOICE

2000 Series e/em Style Keypad Installation and Programming Manual

DG Series. Access Control Proximity Readers DG-160 DG-800

Two Door Controller GEN-045

INSTALLATION INSTRUCTIONS Model 930 EntryCheck

Keypad CT2000. Art. No.: , (black) Art. No.: , (white) Installation Manual

Fast operation of IP Villa System V 1.0

Wireless Key fob, Key pad & Receiver Range

Waterproof Exit Button x40x30/44mm - IP68, 304 Stainless Steel - Voltage: DC12V, DC9-24V (-W402N)

QUICK START GUIDE. 2.4 Inch TFT Terminal Time Attendance & Access Control

Revision Date: 02 Mar 2018

INSTALLATION INSTRUCTIONS 921P EntryCheck TM

AS Keypad User Manual

EZ-TAG2 Manual_Layout 5 11/12/ :14 Page 1 U S E R M A N UAL

CM-500 SK 500 USER CODES KEYPAD

RFID PRODUCT AND SYSTEM

Indoor/Outdoor Proximity Reader and Keypad with 10cm (4in) Read Range

PR602LCD v1.0 Installer Manual Rev. A

212iL Rev. 1.1

Installation Guide for PR311SE and PR311SE-BK v1.0 Access Controllers Rev. B

AC-Q4x Family. Instruction Manual. Vandal Resistant Stand-Alone controllers. Models: AC-Q41H/HB AC-Q41SB AC-Q42H/HB AC-Q42SB AC-Q44

Wiring Guide EP.NMINI. Version 1.02 Last Updated:

AUDIO AND VIDEO DOOR ENTRY SYSTEM WITH NEXA CODED PANEL

GV-AS Controller. Installation Guide

EcoEntry. RFID Proximity Access Control System. User Guide. Revision 2

ROSSLARE AC-115. Hardware Installation and User s Guide DOOR MODE 10/01

Operating Instructions KEYPAD. Compatible WIRELESS ACCESS CONTROL

CRC220 and CRC221 INSTALLATION GUIDE. REF No.: DOC0014 ISSUE: 09

7612 Programming Instructions

IBA-7612 Programming Instructions

SK-3133-PPQ Heavy-Duty Outdoor Access Control Keypad with Proximity Reader

MODEL KP-100 ACCESS CONTROL DIGITAL KEYPAD OPERATING INSTRUCTIONS

EN FULL DETAILS SKB. Vandal Resistant keypad - Full Details

Two-door Access Controller

E-Access ANXELL TECHNOLOGY CORPORATION E3AK4 E3AK2. Specifications Voltage (Input): 12 to 24 VDC

Access control panel U-Prox IC E (Elevator control)

INSTRUCTION MANUAL AC-T43 PIEZO-KEYPAD STANDALONE ACCESS CONTROL UNIT. 07/04

EX8. User Manual. Ver 1.0

MS-7000: SuperStar Reader

AC-Q4x Family Anti-Vandal Standalone Controllers Installation and Programming Manual

9212i INSTALLATION. Stand-Alone Keypad. Instructions

AYC-E/Q/T60 Family Backlit goprox & PIN Reader Convertible Series with Genuine HID Technology Installation and Programming Manual

Contents Safety precautions Product components Optional accessories Names of each parts Product Dimension Cables and Connectors Power Connection

AYC-F/G/M60 Family Backlit goprox & PIN Reader Convertible Series with Genuine HID Technology Installation and Programming Manual

Transcription:

W3M Metal waterproof standalone access control/reader User Manual

Name Digital Keypad W3M User Manual Screw driver Rubber bungs Selftapping screws Diode 1. Packing List Quantity 1 1 1 4 4 1 Remark 6*27mm, used for fixing 4*28mm, used for fixing IN4004 Please ensure that all the above contents are correct. If any are missing please notify the supplier of the W3M. 2. Description The W3M is single door multifunction access controller or a Wiegand output keypad or card reader. It is suitable for mounting either indoor or outdoor in harsh environments. It is housed in a strong, sturdy and vandal proof Zinc Alloy electroplated case. The electronics are fully potted so the W3M is waterproof and conforms to IP65. The W3M supports up to 1500 users in either a Card, or 4~6 digits PIN, or a Card + PIN option and additional 10 groups Antiduress PIN/Card. The inbuiltcard reader supports Mifare, 13.56MHz frequency card/tag. The W3M has many extra features including Antiduress PIN/card, Wiegand 26/34 bits interface, and backlit keypad etc. These features make the W3M an ideal choice for door access not only for small shops and domestic households but also for commercial and industrial applications such as factories, warehouses, laboratories, banks and prisons. 3. Features Waterproof, conforms to IP65 Strong zinc alloy electroplated antivandal case Full programming from the keypad 1500 users, supports Card, PIN, Card + PIN Can be used as standalone keypad only

PIN length:4~6 digits Card interface: Mifare 13.56MHz 10 groups Antiduress PIN/Card Wiegand 26/34 input & output Programmable one relay output Backlight keypad Pulse mode, Toggle mode Adjustable door output time, alarm time, door open time Very low power consumption (30mA) Fast operating speed, <0.1S with 1500 users Lock and alarm output current short circuit protection Built in light dependent resistor (LDR) for anti tamper Built in buzzer Red, Yellow and Green LEDs display the working status DC1224V&AC1218V Two year warranty 4. Specifications Operating Voltage DC1224V&AC1218V User Capacity 1500 Antiduress User Capacity 10 Keypad 12 keys:3 x 4 digits Card Type Mifare 13.56MHz Card Reading Distance 3~6 cm Idle Current 25±5mA Lock Output Load Max 2A Alarm Output Load Max 20A Operating Temperature 20~60 Operating Humidity 10%~ 90% RH Adjustable Door Relay time 1~99 seconds Wiegand Interface Wiegand 26/34 bits Electric Lock, Exit Button, Wiring Connections DOTL, External Alarm Dimensions L128 x W82 x H28 mm Net Weight 600 g Gross Weight 700 g 2

5. Installation Remove the back cover from the keypad using the supplied security screwdriver Drill 4 holes on the wall for the screws and I hole for the cable Fix the back cover firmly on the wall with 4 flat head screws Thread the cable through the cable hole Attach the keypad to the back cover. ALARM OPEN D_IN NO COM NC ALARM OPEN D_IN NO COM NC J1 J1 Antidemolition alarm W3M PCB Connect Diagram 6. Wiring Color Green White Grey Function ALARM Yellow OPEN Brown D_IN Red Black DC1224V&AC1218V DC1224V&AC1218V Blue Purple NO COM Orange NC Pink Description Wiegand output Wiegand output Alarm Negative Connect to Exit Button Door Contact DC1224V&AC1218V Power Input DC1224V&AC1218V Power Input Relay NO Relay COM Relay NC W3M Negative 3

Connection Diagram Pink ALARM OPEN D_IN Green White Grey Yellow Brown Red Black NO Blue COM Purple NC Orange W3M Exit button Door detecting switch Power + Alarm Power + Electric bolt:nc Electric strike:no Common Power Supply Power 1224V/3A + Alarm In4004 + Lock ALARM OPEN D_IN NO COM NC Pink Green White Grey Yellow Brown Red Black Blue Purple Orange Wiegand Wiegand Exit button Door detecting switch Alarm + Power DC12V/3A NC COM NO +12V OPEN + + Failsecure lock Alarm W3M Special Power Supply Notes: Connect the negative pole of the lock to NC is for Fail safe lock. Connect the negative pole of the lock to NO is for Failsecure lock. 4

7. Relay operation (Pulse mode and Toggle mode) The relay on board can operate in Pulse Mode (suitable for access control) or Toggle Mode (suitable for arming/disarming alarms, switching lights, machines.etc) Every time a valid tag/card or Pin is read/input in Pulse Mode, the relay will operate, for the preset relay pulse time. Every time a valid tag/card or Pin is read/input in Toggle Mode, the relay changes state, which will not turn back until read card or input pin again. 8. To Reset to Factory Default To reset to factory default, power off, press *, hold it and power on, release it after hear two beeps, means reset to factory default successfully. Remarks: Reset to factory default, the user's information is still retained. 9. Anti Tamper Alarm The W3M uses a LDR (light dependent resistor) as an anti tamper alarm. If the keypad is removed from the cover then the tamper alarm will operate. 10. Sound and LED Light Indication Operation Status Red Light Green Light Buzzer Power on Bright Beep Stand by Press keypad Operation successful Operation failed Flash slow Bright Beep Beep 3 Beep Enter into programming mode Bright Beep In the programming mode Exit from the programming mode Bright Bright Beep Open the door Alarm Flash quick Bright Beep Alarm 5

11.1 User Settings To enter the programming mode To exit from the programming mode To change the master code * Master code # 888888 is the default factory master code # Note that to undertake the following programming the master user must be logged in Setting the working mode: To set valid card only users 11. W3M Detailed Programming Guide 0 New code # New code # The master code is any 6~8 digits. 3 0 # Entry is by Card only To set valid card and PIN users To set valid card or PIN users (factory default) 3 1 # 3 2 # (default) Entry is by Card and PIN together Entry is by either Card or PIN To add and delete users in either card or PIN mode ( 3 2 # ) (Default setting) To add a PIN users To Delete a PIN user To change the PIN of a PIN user (This step must be done out of programming mode) 1 User ID number # PIN # The ID number is any number between 1 ~ 1500. The PIN is any 4~6 digits between 0000 ~ 999999 with the exception of 1234 which is reserved. Users can be added continuously without exiting from programming mode as follows: 1 User ID No 1 # PIN # User ID No 2 # PIN # 2 User ID number # Users can be deleted continuously without exiting programming mode * User ID number # Old PIN # New PIN # New PIN # 6

To add a card user (Method 1) This is a fast way to enter cards using ID number auto generation. To add a card user (Method 2) This is the optional way to enter cards using User ID Allocation. In this method a User ID is allocated to a card. Only one user ID can beallocated to a single card. To delete card user by card Note Users can be deleted continuously without exiting from programming mode. To delete a card user by user ID. This option can be used when a user has lost their card 1 Read Card # Cards can be added continuously without exiting programming mode 1 User ID number # Card # (The ID number is any number between 1~1500) 2 Read Card # 2 User ID number # To add and delete users in card and PIN mode ( 3 1 # ) To Add a card and PIN user (The PIN is any 4~6 digits between 0000 ~ 999999 with the exception of 1234 which is reserved.) Add the card as for a card user Press * to exit from the programming mode Then allocate the card a PIN as follows: * Read Card 1234 # PIN # PIN # To change a PIN in card and PIN mode (Method 1) Note that this is done out of programming mode so the user can undertake this themselves To delete a Card and PIN user just delete the card by ID number * Read Card Old PIN # New PIN # New PIN # To add and delete card user in card only mode ( 3 0 # ) To Add and Delete a card user To delete All users To delete ALL users. Note that this is a dangerous option so use with care 2 User ID number # The operating is the same as adding and deleting a card user in 3 2 # 2 0000 # 7

To unlock the door For a PIN user For a card user For a card and PIN user Enter the PIN then press # Read card Read card then enter PIN # 11.2 Relay Setting (Pulse mode,toggle mode) Pulse mode(factory default) Pulse mode (Door relay time setting) Toggle mode Toggle mode 4 1~99 # The door relay time is between 1~99 seconds, the factory default setting is 5 seconds. 4 0 # 11.3 Alarm, Door Open Detection, Duress user Settings Alarm output time To set the alarm output time (0~3 minutes). Factory default is 1 minute 5 0~3 # Door Open Detection Door Open Too Long (DOTL) warning. When used with an optional magnetic contact or builtin magnetic contact of the lock, if the door is opened normally, but not being closed after 1 minute, the inside buzzer will beep automatically to remind people to close the door and continue for 1 minute before switching off automatically. Door Forced Open warning. When used with an optional magnetic contact or builtin magnetic contact of the lock, if the door is forced open, or if the door is opened after 120 seconds of the electromechanical lock not closed properly, the inside buzzer and alarm output will both operate. The Alarm Output time is adjustable between 0~3 minutes with the default being 1 minute. To disable door open detection. (Factory default setting) To enable door open detection 6 0 # 6 1 # 8

Keypad Lockout & Alarm Output options. If there are 10 invalid cards or 10 incorrect PIN numbers in a 10 minute period, the keypad will lockout for 10 minutes or the alarm will operate for 10 minutes, depending on the option selected below. Normal status: No keypad lockout or alarm(factory default setting) Keypad Lockout Alarm Output 7 0 # 7 1 # 7 2 # To remove the alarm To reset the Door Forced Open warning Read valid card or Master Code # To reset the Door Open Too Long warning Close the door or Read valid card or Master Code # 11.4 Antiduress User Settings There are 10 groups Antiduress PIN/card available. When input Antiduress PIN/card, the door will open, at the same time, the output alarm operates. To set Antiduress PIN user To add a PIN user To delete a PIN user To set Antiduress card user To add a card user (Method1) User ID number auto generation. To add a card user (Method2) User ID number allocation. To add a card user (Method3) User ID number allocation. To add a card user (Method4) User ID number allocation. 8 User ID number # PIN # The operating is the same as deleting common PIN user 8 Read card1, Read card 2, # (card can be added continuously) 8 User ID number# card1, User ID number # card2, # (The ID number is between 1501~1510) 8 8digits or 10digits card number #, 8digits or 10digits card number #... # (The ID number is between 1501~1510) 8 User ID number# 8digits or 10digits card number #, User ID number # 8digits or 10digits card number #, # (The ID number is between 1501~1510) 9

To delete a card user The operating is the same as deleting common card user Note: 1 User ID number is between 1501~1510 2 Antiduress PIN/card must be unique, should be distinguished from common PIN and card (When the Antiduress PIN/card is the same with common PIN and card, they will become invalid in Antiduress and worked as common user function) 12. Wiegand Mode Setting To set Wiegand 26 format 9 0 # (Default setting: Wiegand 26) To set Wiegand 34 format 9 1 # 13. Keypad Output Format Setting Keypad output format in 4 bit 9 2 # Keypad output format in 10bits virtual card number 9 3 # 14. Interconnecting Two Devices 14.1 W3M operating as a Wiegand Output Reader In this mode the W3M supports a Wiegand 26 bits and 34 bits output so the Wiegand data lines can be connected to any controller which supports a Wiegand 26 or 34 bits input. See figure 1. 10

Pink Green White Grey ALARM V+ Yellow OPEN Brown Red D_IN Black Power V+ Controller Blue Purple Orange NO COM NC figure 1 W3M Transmission Format: 1: Keypad Transmission The Reader will transmit the PIN data when it receives the last key (#) press after PIN code. Format: PIN Code ( PIN code is any 4~6 digits between 0000~999999) For example: 1)Wiegand 26output: PIN code: 5678 Press 5678 #, then the output format will be: 00005678 2)Wiegand 34output: PIN code: 5678 Press 5678 #, then the output format will be: 0000005678 2: Proximity Card Transmission The Reader will transmit the card data when it reads the Card. Format: Card Numbe (Note: No matter the card or PIN is valid or invalid, the data will be transmitted) 11

14.2 W3M operating as a Controller In this mode the W3M supports a Wiegand 26/34 bit input so an external Wiegand device with a 26/34 bit output can be connected to the Wiegand input terminals on the W3M. Either an ID card reader (125 KHz) or an IC card reader (13.56MHz) can be connected to the W3M. Cards are required to be added at the external reader, except where an external Mifare reader is used, in this case cards can be added at either reader or controller. Special Power Supply ALARM OPEN D_IN NO COM NC Pink Green White Grey Yellow Brown Red Black Blue Purple Orange Exit button Door detecting switch Wiegand reader V+ NC + + FailSecure lock DC12V/3A COM NO +12V OPEN FailSecure lock + Alarm W3M figure 2 12

W3M Quick Reference Programming Guide To enter the programming mode * Master code # 888888 is the default factory master code To exit from the programming mode * Note that to undertake the following programming the master user must be logged in To change the master code To add a PIN user To add a card user To delete a PIN or a card user 0 New code # New code # The master code is any 6~8 digits 1 User ID number # PIN # The ID number is any number between 1~1500. The PIN is any 4~6 digits between 0000 ~ 999999 with the exception of 1234 which is reserved. Users can be added continuously without exitingprogramming mode 1 Read Card # Cards can be added continuously without exiting from programming mode 2 User ID number # for a PIN user or 2 Read Card # for a card user Users can be deleted continuously without exiting from programming mode To Unlock the door To unlock the door for a PIN user To unlock the door for a card user Enter the PIN then press # Present the card