HOL09-Entry Level VMAX: Provisioning, FAST VP, TF VP Snap, and VMware Integration

Similar documents
The audience for this document is technical professionals who wish to learn more about using the Dell Compellent VMware vsphere Client Plug-in.

Virtual Storage Console, VASA Provider, and Storage Replication Adapter for VMware vsphere

Hands-on Lab Manual. Introduction. Dell Storage Hands-on Lab Instructions. Estimated Completion Time: 30 minutes. Audience. What we will be doing

Table of Contents HOL-PRT-1467

Increase Scalability for Virtual Desktops with EMC Symmetrix FAST VP and VMware VAAI

VMware vstorage APIs FOR ARRAY INTEGRATION WITH EMC VNX SERIES FOR SAN

INCREASE OPERATIONAL EFFICIENCY FOR SAP INFRASTRUCTURES WITH EMC TIMEFINDER DUPLICATE SNAPS

WHAT S NEW WITH TIMEFINDER FOR EMC SYMMETRIX VMAX

Introduction to Virtualization

Virtual Storage Console, VASA Provider, and Storage Replication Adapter for VMware vsphere

Your instructor will assign you a Cloud Labs username during class. Fill out the details in the fields below for easy reference.

Dell Storage vsphere Web Client Plugin. Version 4.0 Administrator s Guide

Dell SC Series Integration with VMware VVols

Using a Virtual Machine for Cisco IPICS on a Cisco UCS C-Series Server

DELL EMC UNITY: DATA REDUCTION

Virtual Storage Console, VASA Provider, and Storage Replication Adapter for VMware vsphere

SANmelody TRIAL Quick Start Guide

Dell Storage Compellent Integration Tools for VMware

MIGRATING TO DELL EMC UNITY WITH SAN COPY

FUJITSU Storage ETERNUS AF series and ETERNUS DX S4/S3 series

Dell EMC SAN Storage with Video Management Systems

EMC Plugins for VMware vsphere

EMC VSPEX END-USER COMPUTING

NetBackup 7.6 Replication Director A Hands On Experience

CIS 231 Windows 7 Install Lab #2

Send the Ctrl-Alt-Delete key sequence to the Guest OS one of two ways: Key sequence: Ctlr-Alt-Ins Menu Sequence: VM / Guest / Send Ctrl-Alt-Delete

StarWind iscsi SAN & NAS: Configuring 3-node HA Shared Storage for vsphere December 2012

Configuring and Managing Virtual Storage

Dell EMC ME4 Series vsphere Client Plug-in

IBM Storage Management Console for VMware vcenter. Version User Guide. Publication: GA (June 2011)

VMware vcenter Site Recovery Manager 4.1 Evaluator s Guide EVALUATOR'S GUIDE

NEW FEATURES IN EMC ENGINUITY 5875 FOR OPEN SYSTEMS ENVIRONMENTS

Installing VMware vsphere 5.1 Components

SAN Implementation (SANIW)

CIS 231 Windows 10 Install Lab # 3

REVISED 1 AUGUST REVIEWER'S GUIDE FOR VMWARE APP VOLUMES VMware App Volumes and later

Storage Considerations for VMware vcloud Director. VMware vcloud Director Version 1.0

StarWind iscsi SAN & NAS:

REVISED 1 AUGUST QUICK-START TUTORIAL FOR VMWARE APP VOLUMES VMware App Volumes and later

Dell EMC Unity Family

EMC Innovations in High-end storages

Dell PowerVault NX1950 configuration guide for VMware ESX Server software

USING THE EMC VMAX CONTENT PACK FOR VMWARE VCENTER LOG INSIGHT

VMware vsphere 5.5: Install, Configure, Manage Lab Addendum. Lab 3: Configuring VMware ESXi

REDUCE COSTS AND OPTIMIZE MICROSOFT SQL SERVER PERFORMANCE IN VIRTUALIZED ENVIRONMENTS WITH EMC SYMMETRIX VMAX

VMware vfabric Data Director 2.5 EVALUATION GUIDE

StarWind iscsi SAN Software: ESX Storage Migration

CIS 231 Windows 2012 R2 Server Install Lab #1

Surveillance Dell EMC Storage with FLIR Latitude

Preparing Virtual Machines for Cisco APIC-EM

VMware ESX ESXi and vsphere. Installation Guide

EMC Virtual Infrastructure for Microsoft Exchange 2010 Enabled by EMC Symmetrix VMAX, VMware vsphere 4, and Replication Manager

1) Use either Chrome of Firefox to access the VMware vsphere web Client. FireFox

Preparing Virtual Machines for Cisco APIC-EM

Cisco Virtual Application Container Services 2.0 Lab v1

IBM Storage Management Console for VMware vcenter. Version User Guide. Publication: GA

vsan All Flash Features First Published On: Last Updated On:

Virtual Appliance User s Guide

efolder BDR for Veeam VMware Continuity Cloud Guide

vlab Student Hand Out - Overview

Dell PowerVault MD Storage Array VMware Storage Replication Adapter (SRA) Installation and Configuration Manual

Using EMC VMAX Storage in VMware vsphere Environments

Data Migration from Dell PS Series or PowerVault MD3 to Dell EMC SC Series Storage using Thin Import

HP Insight Control for VMware vcenter Server Release Notes 7.2.1

vsphere Replication for Disaster Recovery to Cloud

Archiware Pure Quick Start Guide

Install & Run the EMC VNX Virtual Storage Appliance (VSA)

StarWind iscsi SAN Software: Using an existing SAN for configuring High Availability with VMWare vsphere and ESX server

Virtualizing SQL Server 2008 Using EMC VNX Series and VMware vsphere 4.1. Reference Architecture

Using SANDeploy iscsi SAN for VMware ESX / ESXi Server

Table of Contents HOL-1710-SDC-6

1) Use either Chrome of Firefox to access the VMware vsphere web Client. FireFox

shaping tomorrow with you Eternus VVOL Matthias Bothe Fujitsu Technology Solutions

vsphere Replication for Disaster Recovery to Cloud vsphere Replication 6.5

VMWARE VREALIZE OPERATIONS MANAGEMENT PACK FOR. Dell EMC VMAX. User Guide

Here is Your Customized Document

VMware vsphere 5.0 STORAGE-CENTRIC FEATURES AND INTEGRATION WITH EMC VNX PLATFORMS

Table of Contents HOL-SDC-1422

Basic Configuration Installation Guide

EMC VSI for VMware vsphere Web Client

VMware AirWatch: Directory and Certificate Authority

Veritas Access. Installing Veritas Access in VMWare ESx environment. Who should read this paper? Veritas Pre-Sales, Partner Pre-Sales

DEPLOY/REMOVE A VVOL ENVIRONMENT ON AN EMC VMAX3 OR VMAX ALL FLASH

VIRTUALIZATION MANAGER ENTERPRISE EDITION GETTING STARTED GUIDE

NexentaStor VVOL

Introduction to Dell SC Series: Part 1

Configuring High Availability for VMware vcenter in RMS All-In-One Setup

QNAP SMI-S Provider for System Center Virtual Machine Manager 2012

NexentaStor Storage Replication Adapter User Guide

INTRODUCTION TO THE VVNX COMMUNITY EDITION

Copyright 2012 EMC Corporation. All rights reserved.

Server Fault Protection with NetApp Data ONTAP Edge-T

StorSimple Appliance Quick Start Guide for Software Version 1.2.1

EMC VSI for VMware vsphere AppSync Management

Disaster Recovery of Microsoft Exchange Server 2007 on EMC Celerra iscsi using EMC Replication Manager and VMware vcenter Site Recovery Manager

EMC VSPEX END-USER COMPUTING

VIRTUALIZATION MANAGER ENTERPRISE EDITION GETTING STARTED GUIDE. Product: Virtual Iron Virtualization Manager Version: 4.2

Install ISE on a VMware Virtual Machine

IA L16 - Hands-On Lab Hands on with Instant Backup and Recovery Features of NetBackup 7.6 for VMware

VMware vsphere: Install, Configure, and Manage v6.5 Pod. Installation and Configuration Guide

Transcription:

HOL09-Entry Level VMAX: Provisioning, FAST VP, TF VP Snap, and VMware Integration

HOL09-Entry Level VMAX: Provisioning, FAST VP, TF VP Snap, and VMware Integration 1 VMAX 10K "Hands On Lab" Exercises 1.1 Introduction 4 2 Exercise 1: Entry-Level VMAX Provisioning Storage and Configuring FAST VP 2.1 2.2 2.3 Provisioning Storage 6 Configuring FAST VP 14 Conclusion 17 3 Exercise 2: Entry-Level VMAX TimeFinder VP Snap 3.1 3.2 3.3 3.4 3.5 Create A Device Group 19 Create a device pair for the TimeFinder/Clone Operation 25 Perform the TimeFinder/Clone operation 29 Obtaining More Information 33 Conclusion 34 4 Exercise 3: Entry-Level VMAX Integration With A Virtual Environment 4.1 4.2 4.3 4.4 4.5 Provision VMAX 10K LUN to ESXi5 Host Using SMC 36 Add New Storage to Host Using the VMware vcenter Add Storage wizard 41 VMware Integration and EMC Virtual Storage Integrator 45 Return to SMC for View Of Newly Provisioned Storage 46 Conclusion 48 5 End of "Hands On Lab" Exercises 5.1 Wrap Up 50

VMAX 10K "Hands On Lab" Exercises HOL09-Entry Level VMAX: Provisioning, FAST VP, TF VP Snap, and VMware Integration - 3

Introduction Welcome to the VMAX 10K Hands-on lab exercises. This is a series of exercises providing an introduction to the latest features of Enginuity 5876 using a virtual environment. This environment provides each lab user exclusive use of a VMAX 10K, permitting a range of operations without interference to other labs. Virtual Enginuity has limitations and this is most obviously seen with small device sizes however all lab exercises have been tested and verified. It is still possible that operations outside exercise boundaries will cause errors. If this occurs, a user need only raise a hand to request assistance whereb y the environment can b e reset and the exercise restarted. The following exercises are available for you to experience. Each exercise can be executed in order or independently. 1. - Entry-Level VMAX Storage Provisioning Configuring FAST VP 2. - Entry-Level VMAX TimeFinder and VP SNAP 3. - Entry-Level VMAX Integraion With A Virtual Environment HOL09-Entry Level VMAX: Provisioning, FAST VP, TF VP Snap, and VMware Integration - 4

Exercise 1: Entry-Level VMAX Provisioning Storage and Configuring FAST VP HOL09-Entry Level VMAX: Provisioning, FAST VP, TF VP Snap, and VMware Integration - 5

Provisioning Storage This document demonstrates how to use Symmetrix Management Console to provision storage and configure FAST VP to automate the tiering of data. Version 7.3.3 of the Symmetrix Management Console is used for the lab exercise of this demonstration. EMC Symmetrix Management Console (SMC) provides a simple, integrated experience for managing EMC Symmetrix VMAX 10K storage systems through both a storage and VMware lens. It s designed to provide simplicity, flexibility, and ease-of-use. All are key requirements for the journey to the private cloud. Built with simplicity and ease-of-use in mind, the VMAX 10K is 100 percent virtually provisioned, with storage tiering managed automatically by EMC Fully Automated Storage Tiering for Virtual Pools (FAST VP). Flash, FC, and SATA drives are all supported, as well as RAID 1, 5, and 6 protection options. Login to SMC From the Desktop, double-click the icon labeled SMC 7.3.3. Bypass the Security Certificate Warning Click the Continue to this website link to continue. HOL09-Entry Level VMAX: Provisioning, FAST VP, TF VP Snap, and VMware Integration - 6

Enter smc for the User Name and Password, and then click Login to continue. Provision Storage to New Host Examine the Symmetrix Dashboard and find the VMAXe ending in 01 and view the used and free Virtual Pool Capacity. Click the "Right Arrow" button next to Virtual Pool Capacity and view the used and free Physical Capacity. 100% of the physical capacity of the VMAXe has been factory pre-configured for the default thin pools and tiers. Here we will walk through the Add New Host Wizard to show how easily we can provision stroage to a newly added host. HOL09-Entry Level VMAX: Provisioning, FAST VP, TF VP Snap, and VMware Integration - 7

Add New Host Wizard Click Add New Host in the Common Tasks pane. Add New Host Wizard Welcome Page Examine the welcome page of the Add New Host wizard. The Add New Host wizard will guide you through the process of adding a new host, provisioning Thin storage, and putting the storage under control of FAST VP. Click the Next button on the welcome page. HOL09-Entry Level VMAX: Provisioning, FAST VP, TF VP Snap, and VMware Integration - 8

Select Initiators Page Complete the Create Host page as follows: Host name: Production Symmetrix: 01 Initiator to add: Select iqn.1991-05.com.microsoft:vc-w8-01a.corp.local Select Ports Page Examine the Select Ports page of the wizard. The ports which are visible to the host have been pre-selected. If you wish to include ports which are not visible to the host select the "include hosts not visible to this host" checkbox. Click the Next button to continue to the next page in the Add New Host wizard. HOL09-Entry Level VMAX: Provisioning, FAST VP, TF VP Snap, and VMware Integration - 9

Select Storage Page Complete the Define Storage page as follows. Number of Thin devices: 1 Capacity for each Thin device: 2 GB Select a pool: Select the FC_R1 Virtual Pool Select the check box next to Put under FAST Control Select FAST VP policy: DEFAULT from the pulldown Click Next when finished HOL09-Entry Level VMAX: Provisioning, FAST VP, TF VP Snap, and VMware Integration - 10

Summary page Examine the Summary page of the Add New Host wizard, click Finish when done, and wait for the wizard to complete the operation. When the wizard has completed you will see this dialog box. Click the Close button to complete this wizard. HOL09-Entry Level VMAX: Provisioning, FAST VP, TF VP Snap, and VMware Integration - 11

Navigate to masking view The Add New Host wizard created a masking view which holds information about the host, storage, and ports. To view this data, click the properties button and expand the navigation tree to the Masking Views folder. Select the Masking View that has the name that you specified in the previous step. HOL09-Entry Level VMAX: Provisioning, FAST VP, TF VP Snap, and VMware Integration - 12

Masking View Properties Screen Examine the Storage Groups, Port Groups, and Initiator Groups tab pages. These pages contain the storage, ports, and initiators that were configured using the Add New Host wizard HOL09-Entry Level VMAX: Provisioning, FAST VP, TF VP Snap, and VMware Integration - 13

Configuring FAST VP Create a FAST VP Policy Expand the FAST folder on the Navigation Tree and examine the contents. The Symmetrix Tier folder holds the Virtual Pool Tiers which were factory pre-configured. Depending on the configuration of your array you may have one to three tiers. Select Create Policy To create a FAST VP Policy, right-click on the Policies folder and traverse the context menu through FAST, then FAST Policy Management, and select Create Policy. HOL09-Entry Level VMAX: Provisioning, FAST VP, TF VP Snap, and VMware Integration - 14

Create FAST Policy Complete the Create FAST Policy dialog as follows. Policy Name: Production Tier: EFD_R1, 3% Tier: FC_R1, 30% Tier: SATA_R1, 100% This FAST Policy will tell the FAST feature that at any one time a maximum of 3% of the storage can reside on Enterprise Flash Drives, 30% on Fibre Channel drives, and 100% on SATA drive techology. Navigate to the Storage Group To apply the policy to the Storage Group which we created as part of Step 4, expand the Navigation Tree to Production_SG by expanding Symmetrix Masking folder and then Storage Groups folder. A storage group is a collection of volumes which will be presented to a host when the storage group is associated to an initiator group and port group as part of a masking view. HOL09-Entry Level VMAX: Provisioning, FAST VP, TF VP Snap, and VMware Integration - 15

Select Associate FAST Policy Right-click on Production_SG and navigate the context menu through FAST, then Fast Policy Management. Click Associate FAST Policy. FAST Policy Association In the Associate a FAST Policy with Storage Group dialog, select the FAST VP Policy that you created in Step 3. Click the OK button when complete and Yes to the confirmation dialog. HOL09-Entry Level VMAX: Provisioning, FAST VP, TF VP Snap, and VMware Integration - 16

Conclusion Conclusion You can navigate to any exercise of VMAX 10K Hands On Lab here: 1. - Entry-Level VMAX Storage Provisioning and Configuring FAST VP 2. - Entry-Level VMAX TimeFinder and VP SNAP 3. - Entry-Level VMAX Integraion With A Virtual Environment References Refence documentation is available on EMC Powerlink by perfoming a title search: Best Practices for FAST, Simple Capacity Allocation with EMC Symmetrix Virtual Provisioning FAST VP for EMC Symmetrix VMAX Theory and Best Practices for Planning and Performance Storage Provisioning with Symmetrix Autoprovisioning Groups Implementing Fully Automated Storage Tiering for Virtual Pools (FAST VP) for EMC Symmetrix VMAX Series Arrays HOL09-Entry Level VMAX: Provisioning, FAST VP, TF VP Snap, and VMware Integration - 17

Exercise 2: Entry-Level VMAX TimeFinder VP Snap HOL09-Entry Level VMAX: Provisioning, FAST VP, TF VP Snap, and VMware Integration - 18

Create A Device Group The purpose of this lab is to show the use of ease configuring VP Snap sessions on a VMAX 10K system. Using SMC, muliple VP Sessions can be setup in a matter of minutes. Version 7.3.3 of the Symmetrix Management Console is used for the lab exercise of this demonstration. VP Snap leverages TimeFinder/Clone technology and adds the ability to share capacity allocation for track groups originating from the same source volume, similarly to how TimeFinder/Snap copies share tracks today on the VMAX. This new ability makes a VP Snap the best of both worlds in terms of cache and storage efficiency. EMC Symmetrix Management Console (SMC) provides a simple, integrated experience for managing EMC Symmetrix VMAXe storage systems through both a storage and VMware lens. It s designed to provide simplicity, flexibility, and ease-of-use. All are key requirements for the journey to the private cloud. Built with simplicity and ease-of-use in mind, the VMAX 10K is 100 percent virtually provisioned, with storage tiering managed automatically by EMC Fully Automated Storage Tiering for Virtual Pools (FAST VP). Flash, FC, and SATA drives are all supported, as well as RAID 1, 5, and 6 protection options. Login to SMC From the Remote Desktop, double-click the icon labeled SMC. Bypass the Security Certificate Warning Click the Continue to this website link to continue. HOL09-Entry Level VMAX: Provisioning, FAST VP, TF VP Snap, and VMware Integration - 19

Enter smc for the User Name and Password, and then click "Login" to continue. From the Dashbaord, select the VMAX 10K system running the latest 5876 code by clicking on the serial number 000194900001 Create a Device Group Select the Properties tab at the top of the page and find the Device Groups folder in the Navigation Tree. HOL09-Entry Level VMAX: Provisioning, FAST VP, TF VP Snap, and VMware Integration - 20

Right-click the "Device Groups" folder and navigate the menu to Create Group. Creating a unique device group is beneficial to keep your replication pairs distinct. It is also useful when creating consistency groups and want to add pairs to that group, you can operate at the device group level instead of individual pair level. Device Group Name: LocalCopy Symmetrix ID: 0001949000001 Device Group Type: REGULAR Device Type: STD Available Device: 048 HOL09-Entry Level VMAX: Provisioning, FAST VP, TF VP Snap, and VMware Integration - 21

As you can see there are several "available" devices. For this lab, device 48 is picked as the STD device. Click on Add to add the device 48 to the Device Group Complete the Device Group Management dialog as follows: Device Type: TGT HOL09-Entry Level VMAX: Provisioning, FAST VP, TF VP Snap, and VMware Integration - 22

Device: 049 Click on Add to add the device 49 to the Device Group As you can see after adding the devices, device 48 is the STD device and device 49 is the TGT device Click OK. After clicking OK, will see a Progress Montior for "Configuring STDs in Device Group". HOL09-Entry Level VMAX: Provisioning, FAST VP, TF VP Snap, and VMware Integration - 23

The Successful creation message confirms the creation of the Device Group. Click Ok Expand the Navigation Tree and select the LocalCopy Device Group. HOL09-Entry Level VMAX: Provisioning, FAST VP, TF VP Snap, and VMware Integration - 24

Create a device pair for the TimeFinder/Clone Operation Create the pair Right-click the LocalCopy Device Group and navigate the menu to select TimeFinder/Clone. HOL09-Entry Level VMAX: Provisioning, FAST VP, TF VP Snap, and VMware Integration - 25

Select Local TGT in the Clone Type Select Set Exact Pairs to autoselect the devices 48 (source) and 49 (replica) Hit Next. HOL09-Entry Level VMAX: Provisioning, FAST VP, TF VP Snap, and VMware Integration - 26

Unselect "Copy" and "Differential". Select the VP Snap option and then click Finish Will be asked to confirm if you want to perform the Timefinder Clone action, click OK. Will see a Progress Montior for the Timefinder Clone request just submitted HOL09-Entry Level VMAX: Provisioning, FAST VP, TF VP Snap, and VMware Integration - 27

Will get a successful completion message. Click OK. Navigate to the Clone Pairs folder on the Navigation Tree under Replication Views to view the status of the device pair. The device pair has the status of Created and VSE indicates "VP Snap". HOL09-Entry Level VMAX: Provisioning, FAST VP, TF VP Snap, and VMware Integration - 28

Perform the TimeFinder/Clone operation Perform the TimeFinder/Clone operation Navigate to the LocalCopy Device Group. Right-click the group and navigate the menu to select TimeFinder/Clone. HOL09-Entry Level VMAX: Provisioning, FAST VP, TF VP Snap, and VMware Integration - 29

The default action for Clone Type is Activate and the select all the device pairs in the Device group (in this example only one pair). Click Next when complete. HOL09-Entry Level VMAX: Provisioning, FAST VP, TF VP Snap, and VMware Integration - 30

1. Click FINISH to complete the TimeFinder/Clone operation. Click OK to the question if you want to perform the Timefinder Clone operation Will see a Progress Monitor for the Timefinder Clone operation just requested HOL09-Entry Level VMAX: Provisioning, FAST VP, TF VP Snap, and VMware Integration - 31

After clikcing Finish, will get a successful Completion message. Navigate to and select the Clone Pairs folder. Navigate to Replication Views -> Clone Pairs. Observe the CopyOnWrite state of the device pair and "VSE" indicates VP Snap. HOL09-Entry Level VMAX: Provisioning, FAST VP, TF VP Snap, and VMware Integration - 32

Obtaining More Information Cache Savings using Timefinder VP Snap The purpose of this lab was to show the ease of use of setting up a Timefinder VP Snap pair. VP Snap has a smaller cache footprint than Timefinder Clone. There is a comprehensive Timefinder VP Snap Lab for VMAX using the Command Line Iterface that demonstrates these savings. Please refer or run that lab if interested. HOL09-Entry Level VMAX: Provisioning, FAST VP, TF VP Snap, and VMware Integration - 33

Conclusion You can navigate to any exercise of VMAX 10K Hands On Lab here: 1. - Entry-Level VMAX Storage Provisioning Configuring FAST VP 2. - Entry-Level VMAX TimeFinder and VP SNAP 3. - Entry-Level VMAX Integraion With A Virtual Environment Resources Product documentation For additional information, see the EMC product documents listed below. EMC Replication Manager Administration Guide EMC Symmetrix Timefinder Guide for VMAX 10K EMC Replication Manager Product Guide HOL09-Entry Level VMAX: Provisioning, FAST VP, TF VP Snap, and VMware Integration - 34

Exercise 3: Entry-Level VMAX Integration With A Virtual Environment HOL09-Entry Level VMAX: Provisioning, FAST VP, TF VP Snap, and VMware Integration - 35

Provision VMAX 10K LUN to ESXi5 Host Using SMC Login to SMC (if not already logged in from a previous exercise) From the Remote Desktop, double-click the icon labeled SMC. Bypass the Security Certificate Warning Click the Continue to this website link to continue. (say "yes" if prompted to let the website close the previous page) HOL09-Entry Level VMAX: Provisioning, FAST VP, TF VP Snap, and VMware Integration - 36

Enter smc for the User Name and Password, and then click to continue. Provision Storage to New Host Examine the Symmetrix Dashboard and find the VMAX 10K ending in 001 and view the used and free Virtual Pool Capacity. Click the button next to Virtual Pool Capacity and view the used and free Physical Capacity. Note that the physical capacity of the VMAX 10K has been factory pre-configured for the default thin pools and tiers. Click Add New Host in the Common Tasks pane. HOL09-Entry Level VMAX: Provisioning, FAST VP, TF VP Snap, and VMware Integration - 37

Examine the welcome page of the Add New Host wizard. The Add New Host wizard will guide you through the process of adding a new host, provisioning Thin storage, and putting the storage under control of FAST VP. Click the Next button on the welcome page. Complete the Create Host page as follows. Host name: ESXi5 Symmetrix: 001 Initiator to add: Click on the ESX_IG in the display Click Next to continue to the Select Ports page of the wizard. HOL09-Entry Level VMAX: Provisioning, FAST VP, TF VP Snap, and VMware Integration - 38

The ports which are visible to the host have been pre-selected as the defaults ports. Accept the defaults and click Next to continue to the next page in the Add New Host wizard. Complete the Define Storage page as follows. Number of Thin devices: 1 Capacity for each Thin device: 2.0 Select a pool: SATA_R1 HOL09-Entry Level VMAX: Provisioning, FAST VP, TF VP Snap, and VMware Integration - 39

Put under FAST control: Select checkbox FAST VP policy: DEFAULT Click the Next button when completeto advance toi the Summary page. Summary page Examine the Summary page of the Add New Host wizard, click Finish when done, and wait for the wizard to complete the operation. Note that the Wizard has completed, and click Show Details. Click OK, then click Close to return to the SMC dashboard. Minimize the SMC window HOL09-Entry Level VMAX: Provisioning, FAST VP, TF VP Snap, and VMware Integration - 40

Add New Storage to Host Using the VMware vcenter Add Storage wizard Log into VMware vcenter using the vsphere Client icon on the desktop User name: Administrator Password: VMware1! HOL09-Entry Level VMAX: Provisioning, FAST VP, TF VP Snap, and VMware Integration - 41

Integrate VMware Log into VMware vcenter, select the esx-01a.corp.local host, and then select the Configuration tab of vcenter, choose -> Storage Adapters -> Rescan all Click OK to rescan for both New Storage Devices and New VMFS Volumes HOL09-Entry Level VMAX: Provisioning, FAST VP, TF VP Snap, and VMware Integration - 42

Note that the iscsi Software Adapter has recognized the newly created device with the Runtime Name vmhba33:c0:t0:l0 and a Capacity of 2.00 GB Add New Storage To VMware Choose the vcenter Configuration tab and click Storage, Add Storage to run the VMware Add storage wizard. Choose DISK/LUN, then click Next. Select the EMC iscsi Disk, and create a VMware Datastore on the LUN by accepting the defaults. Select VMFS 5, inspect the current disk HOL09-Entry Level VMAX: Provisioning, FAST VP, TF VP Snap, and VMware Integration - 43

layout. Choose any Datastore name you wish, for example, "Hands On Lab". Choose the Maximum available space, and click Finish to complete the Add Storage wizard. The vcenter display will automatically refresh after a few seconds, and the Hands on Lab datastore will appear in the list HOL09-Entry Level VMAX: Provisioning, FAST VP, TF VP Snap, and VMware Integration - 44

VMware Integration and EMC Virtual Storage Integrator From the vcenter display, click the EMC VSI tab, which defaults to the Storage Viewer feature and the Datastores View. Select the new Datastore, view details about the storage by using the Storage Details buttons Common and Paths. Use the slider bar to display detailed information about the storage "behind" the datastore Choose the LUNs and then the Targets view. Use the slider bar to gain additional information about the LUNs and array target ports associated with vmhba33 by highlighting each in turn. Minimize the vcenter diaply, and return to the SMC interface to examine the corresponding storage-to-vmware view of the Symmetrix VMAX 10K device which includes information about the ESXi host, its datastores, and VMs HOL09-Entry Level VMAX: Provisioning, FAST VP, TF VP Snap, and VMware Integration - 45

Return to SMC for View Of Newly Provisioned Storage SMC View Re-open the Symmetrix Management Console interface, choose the Tasks menu, and select Manage Virtual Server Storage in the lower left hand corner of the display HOL09-Entry Level VMAX: Provisioning, FAST VP, TF VP Snap, and VMware Integration - 46

From the Manage Virtual Server Storage screen, choose Load All Servers, and then select the ESXi5 server that is displayed, 192.168.110.51. Use the General and Server Devices tab to view ESXi, Datastore, and LUN details from within SMC. Note that the Server Devices tab displays corresponding information about the Symmetrix device, its associated Datastore, and any virtual machines present on the Datastore. Also choose the VM tab within the display for further information. This concludes the VMware Integration portion of the VMAX 10K Hands on Lab. HOL09-Entry Level VMAX: Provisioning, FAST VP, TF VP Snap, and VMware Integration - 47

Conclusion You can navigate to any exercise of VMAX 10K Hands On Lab here: 1. - Entry-Level VMAX Storage Provisioning Configuring FAST VP 2. - Entry-Level VMAX TimeFinder and VP SNAP 3. - Entry-Level VMAX Integration With A Virtual Environment HOL09-Entry Level VMAX: Provisioning, FAST VP, TF VP Snap, and VMware Integration - 48

End of "Hands On Lab" Exercises HOL09-Entry Level VMAX: Provisioning, FAST VP, TF VP Snap, and VMware Integration - 49

Wrap Up Thank you for taking the time to complete the VMAX 10K Hands-on lab session. We hope the lessons spark an interest in you to learn more about the new features in Enginuity 5876 for the VMAX family. HOL09-Entry Level VMAX: Provisioning, FAST VP, TF VP Snap, and VMware Integration - 50