HelmView Model HV750. Installation Manual Section 78

Similar documents
HelmView Model HV750; HVS750. Installation Manual Section 78

HelmView 450 Model HV450. Installation Manual Section 78

PowerView Model PV750. Installation and Operations Manual Section 78

PowerView Model PV1000. Hardware Installation Manual Section 78

PowerView Model PV485. Installation Manual Section 78

PowerView Model PV450. Installation and Operation Manual Section 78

PowerView Model PV350 and PV380. Installation Manual Section 78

PowerView Model PV450. Installation and Operation Manual Section 78

PowerView Model PV450. Installation and Operation Manual Section 78

*Approved by CSA for non-hazardous locations (Group Safety Publication IEC Third Edition).

PowerCore Model TEC-10 Installation Manual

MLC 380 R2. For Mechanical Engines. Installation Manual

Programmed with Eaton Pro-FX Control Software 32-bit Processor, 7 WVQA Sunlight Viewable Display

HelmView Model HV1000. Operations Manual Section 78

Programmed with Eaton Pro-FX Control Software 32-bit Processor, 4.3 WVQA Sunlight Viewable Display

Programmed with Eaton Pro-FX Control Software 32-bit Processor, 4.3 WVQA Sunlight Viewable Display

PowerView TM Model PV350 and PV380. Operations Manual Section 78

Applications: Industrial Automation, Cranes, Hoists, Utility Vehicles, Off-highway, Ag, and Forestry Equipment

Control Panel CP600-eCo CP604, CP604-B

Programmed with Eaton Pro-FX Control Software 32-bit Processor, 4.3 WVQA Sunlight Viewable Display

Adapter Kit for PanelView 1200/1200e Touch Screen Terminal Cutout

MultiViu Flex 4 Data Sheet

Rackmount LCD Console - 1U - 17in Screen - US Keyboard p

TM241C40U controller M IO transistor NPN

DSEM870. DSEControl PROGRAMMABLE DISPLAY FOR USE IN VEHICLES AND OFF-HIGHWAY MACHINERY

PanelView Plus/VersaView CE Terminals and Display Modules

TM241C24T controller M IO transistor PNP

DAWN Mini ADAQ TC20 Details

TECHNICAL DATASHEET #TDAX050000K CAN

TECHNICAL PRODUCT DATASHEET

EXPRESS SETUP. PanelMate 1700 Series PanelMate Power Pro. Cutler-Hammer

ISO 9001 CERTIFIED. 607 NW 27th Ave Ocala, FL Phone: (352) or Fax: (352) SUITABLE FOR EXTERNAL DISTRIBUTION

Applications: Industrial Automation, Cranes, Hoists, Utility Vehicles, Off-highway, Ag, and Forestry Equipment

TM241C40R controller M IO relay

TM241CE24T controller M IO transistor PNP Ethernet

FG series FIXED GRIP hand controllers

HG series Hand grip Hall effect joysticks

Technical Data Sheet OPUS A6 ECO Full TDS OPUS A6eF,

Technical Data Sheet OPUS A6 STANDARD Full TDS OPUS A6sF,

Technical Data Sheet OPUS A6 ECO Basic TDS OPUS A6eB,

QTERM -A7 TERMINAL HARDWARE MANUAL

Control Panel CP600 CP651, CP651-WEB

Applications: Industrial Automation, Cranes, Hoists, Utility Vehicles, Off-highway, Ag, and Forestry Equipment

Operating Instructions 12/2010 MN Z-EN XV-152 MICRO PANEL

Technical Data Sheet OPUS A6 ECO Basic

TM241CE24U controller M IO transistor NPN Ethernet

Control Panel CP600 CP635, CP635-B, CP635-WEB

2 Device description. 2 Device description 2.1 Function. 2.1 Function. 2.2 Intended use. 2.3 Device versions

TM241CE40R controller M IO relay Ethernet

TM221CE40R controller M IO relay Ethernet

TM241CEC24R controller M IO relay Ethernet CAN master

7511 / / / 711 / / 731 / Preset 27

S7999D SOLA Operator Interface Display

Solid State Digital Hourmeters & Counters: 700 Series

TM241CE40R controller M IO relay Ethernet

TM241CE24T controller M IO transistor PNP Ethernet

TM221M16R controller M IO relay

Technical Data Sheet OPUS A6 STANDARD Full

TM241CE40T controller M IO transistor PNP Ethernet

Control Panel CP600 CP635-FB, CP635-FW

HMISCU6B5 3 5 color touch controller panel - Dig 8 inputs/8 outputs +Ana 4 In/2 Out

TECHNICAL PRODUCT DATASHEET

Specifications: Dell 1703FP Flat Panel Color Monitor User's Guide

Technical Data Sheet OPUS A6 ECO Basic TDS OPUS A6eB,

Technical Data Sheet OPUS A6 ECO Basic

HMISCU6A5 3 5 color touch controller panel - Dig 16 inputs/10 outputs

CompactBlock Guard I/O EtherNet/IP Safety Modules

TM221CE40T controller M IO transistor PNP Ethernet

HMISCU8A5 5 7 color touch controller panel - Dig 16 inputs/10 outputs

In-Sight I/O. In-Sight expansion module (For use with in-sight 5000 series vision sensors and Id readers, and 3400 vision sensors)

TM241CE40R controller M IO relay Ethernet

HG series Hand grip Hall effect joysticks

ISO 9001 CERTIFIED. 607 NW 27th Ave Ocala, FL Phone: (352) or Fax: (352) OPERATION MANUAL

TM221CE24R controller M IO relay Ethernet

MS series Mid-size Hall effect joysticks

CDC2000X. Technical Data Sheet

TM241C24R. Main. Discrete output type. Discrete output number. 14 (remote I/O architecture) 50 µs turn-on operation with I0...I13 terminal(s) input

P/N: AX Distribute your control functions directly onto the valve.

Technical Data Sheet OPUS A3 STANDARD Basic TDS OPUS A3sB,

Applications: Stationary, portable power generator sets Genset control systems

TM221M16TG controller M IO transistor PNP spring

ArmorPoint I/O Field Potential Distributor, Series A

1U 17" HD 1080p Dual Rail Rackmount LCD Console w/ Fingerprint Reader and Front USB Hub

TM251MESC controller M251 Ethernet CAN

User Interface Terminal for nvent RAYCHEM NGC Systems Installation Instructions DESCRIPTION TOOLS REQUIRED. Nonhazardous Locations LR67275

Discrete I/O 12 Discrete Inputs 8 Relay Outputs CANopen P/N: AXDIO128CO

HT series Ruggedized Hall effect joysticks

Technical Data Sheet OPUS A3 ECO Full

TM221CE24T controller M IO transistor PNP Ethernet

Technical Data Sheet OPUS A3 STANDARD Basic TDS OPUS A3sB,

TM241CEC24T. Main. 14 (remote I/O architecture) W with max number of I/O expansion module ma fast input. 2.

Technical Data Sheet OPUS A3 STANDARD Basic

Technical Data Sheet OPUS A8 ECO Basic

HMISCU6B5. Main. 60 right 40 top 60 bottom

P/N: AX Applications: power gen set engine control systems oil and gas equipment automation off-highway machine automation

TM241CE24T controller M IO transistor PNP Ethernet

Technical Data Sheet OPUS A6 ECO Full

OMNI Expandable HMI Panel Computer with Intel Celeron J1900/ N2807 Processor

User s Manual. Revision 1.0. Copyright 2016 Maretron, LLP All Rights Reserved

TM241CE40R controller M IO relay Ethernet

Transcription:

HelmView Model HV750 Installation Manual 00-02-0803 11-11-11 Section 78

In order to consistently bring you the highest quality, full featured products, we reserve the right to change our specifications and designs at any time. The latest version of this manual can be found at www.fwmurphy.com. Please read the following information before installing. BEFORE BEGINNING INSTALLATION OF THIS MURPHY PRODUCT: Read and follow all installation instructions. Please contact FW MURPHY immediately if you have any questions.

Contents Hardware Installation... 1 Inspecting Package Contents... 1 Dash-Mounted Installation... 1 Wiring Instructions... 5 Single Engine... 5 PVA and Dual Engine Gages... 6 USB Wiring... 7 Analog Video... 8 NMEA Wiring... 9 Pin Specifications for Deutsch DT04-6P Style Connections... 10 Wiring Schematic... 11 Specifications... 12

(THIS PAGE INTENTIONALLY LEFT BLANK)

Hardware Installation The following instructions will guide you through installing the HelmView HV750 display. Inspecting Package Contents Before attempting to install the product, we recommend you account for all parts and inspect each item for damage (which sometimes occurs during shipping). The items included in the box are: HV750 unit Installation kit P/N 78-00-0638 includes: 4 ea. machine screws and flat washers 4 Nylock nuts Installation manual P/N 00-02-0803 Operations Manual P/N 00-02-0805 Dash-Mounted Installation Tools needed. Drill with 5/32 size bit Jig Saw Wrench or socket 6-32 Nylock nuts (provided) to studs Preparing the Dash Determine the location of the HelmView in the dash. Use the Installation Template (included at the end of the manual) as a guideline to cut a hole in the dash to the specified dimensions. Drill holes where indicated on the template for the mounting screws. NOTE: When using the paper template from the manual, if you downloaded this document from the FW Murphy website, be aware that the pdf file may not automatically print to scale. When submitting the file for print, you will need to select None for Page Scaling. Check the accuracy of the printed template by verifying the measurements labeled on the template are correct. 11-11-11-1 -

Mounting the Unit 1. Place the backside of the display through the opening in the dash. 2. Use the four screws to line up the unit with the drilled holes. 3. Push the unit through the opening and screws through the drilled holes until the back of the case is flush. 4. Use the Nylock nuts provided to tighten unit to the dash. Use the appropriate wrench or socket to tighten. Torque lock nuts to 8-10 inch pounds. Flush Mounting the Dash 1. Cut the dash to allow for the display without bezel. Make sure enough material remains to properly secure the display within the dash. Torque the 6-32 Nylock nuts to 5-inch pounds. 2. Place the display behind dash and line up the four mounting holes on the display with the holes in dash. 3. Install four bolts and tighten nuts. 11-11-11-2 -

Wiring Instructions The following illustrations are examples of typical quick-connect options for setup. Wiring harnesses are sold separately. Single Engine 11-11-11-5 -

PVA and Dual Engine Gages NOTE: Port B and C connectors are keyed differently than Port A and D connectors to ensure proper connection. If both PVA gages* and Video camera are going to be used, an extra harness is needed (P/N 78000688 PVW-750-MINI). *Please note, PVA Gages are not certified. 11-11-11-6 -

USB Wiring 11-11-11-7 -

Analog Video NOTE: If both PVA gages and video camera are going to be used, an extra harness is needed (P/N 78000688 PVW-750-MINI). 11-11-11-8 -

NMEA Wiring 11-11-11-9 -

Pin Specifications for Deutsch DT04-6P Style Connections Signal Definitions CAN 3 ports according to CAN specification 2 (1 port isolated according to NMEA 2000) USB 2.0 host Video input: NTSC/PAL Inputs (3) 0-5 VDC analog inputs (1 input configurable to support measurement frequencies from 2 Hz - 10kHz, values from 0-100% duty cycle) Output: Digital, capable of sinking 500mA. 11-11-11-10 -

Wiring Schematic 11-11-11-11 -

Specifications Electrical Display 7 (178mm) color transmissive TFT LCD Resolution WVGA, 800 x 480 pixels, 16-bit color Aspect Ratio 16:9 Orientation Landscape Backlighting LED, 400-500 cd/mc (50,000 h lifetime) Microprocessor Freescale IMX.31 32bit, 400 MHz Operating System QNX operating system Flash Memory 2 GB RAM 128 Mbytes SDRAM Operating Voltage 8-35 VDC, protected against reverse polarity and load-dump Power Consumption 10 W full backlight 22 W full backlight with heater (< -10º C) CAN 3 CAN ports according to CAN specification 2.0B. One port isolated according to NMEA 2000 (GPS) RS-485 1 MODBUS Master port at 38.4 Kbaud Protocols J1939, NMEA 2000 Connection 5 Deutsch DT04-6P 6-pin connectors Keyboard 10 tactile buttons USB USB 2.0 host (full speed) Inputs (3) 0-4 VDC Analog inputs (1) input configurable to support measurement frequencies from 2 Hz-10 khz Video Input NTSC/PAL Output Digital, capable of sinking 500mA Environmental Certifications ABS Type Approved display for Marine and Offshore Applications on ACC, ACCU, and ABCU Classed vessels Operating Temperature -40ºC to +85ºC (-40ºF to 185ºF) Storage Temperature -40ºC to +85ºC (-40ºF to 185ºF) Protection IP67, front and back Emissions IEC 60945, 95/54/EC Immunity SAE J1113, ISO 11452 Vibration Random vibration, 7.86 G rms (5.2000 Hz), 3 axis Shock +/- 50G in 3 axis 11-11-11-12 -

Mechanical Dimensions Shipping Weight Case Material (W x H) 8.37 x 6.0 in (212.5 x 152.3mm) landscape Unit Depth 3.57 in (90.8mm) Approximately 2.5 lbs. (1.13 kg) Polycarbonate back case 11-11-11-13 -

11-11-11-14 -

CALL MURCAL TO PLACE YOUR ORDER MurCal www.murcal.com P:(661)272-4700 F:(661)947-7570 e-mail: sales@murcal.com