Ultegra Baggage Scale. SCB-R9000-B Series 31 x 31 Baggage Scale. Operator Manual

Similar documents
Operator Manual. Ultegra MAX. SCB-R9050 Series 21 x 21 Bench Scale by Fairbanks Scales, Inc All rights reserved Revision /15

Service Manual. Operators Manual. Ultegra Health Scale by Fairbanks Scales, Inc All rights reserved Revision 7 04/17

Ultegra Bench Scale SCB-R U USB Powered

Ultegra Bench Scale SCB-R U USB Powered

Installation Manual. Ultegra Junior Bench Scale. USB Interface by Fairbanks Scales, Inc All rights reserved Revision 4 07/13

5000 Series Bench Scale Platforms

QuickSilver Series Bench Scale

Installation / Operator / Service Manual. Bench Scales Revision 6 07/ by Fairbanks Scales Inc. All rights reserved

Industrial SBU Product User s Manual

MODEL PS-11 DIGITAL PORTION SCALE

QC-3265 Checkweigher User s Manual

FB1100 Series. Digital Instrument Products: Owner s Manual

1.0 Description. 2.0 Unpacking. 3.0 Installation

Model SRV411i Small Animal Floor Scale Service Manual Part No. MANSRV411i_ Page 1 of 16. Small Animal Floor Scale. Operating and Service Manual

Digital Bench Scale. Revision 8.93 August 12, 1993

Presented By. NicolScales.com Contact Us

ClearCube F6151 Media Converter Chassis System with 10/100BaseTX to 100BaseFX Converter

Epson SureColor F6070 Setup Guide

OV1000 Part No OV1000 HEIGHT ADJUSTABLE TABLE USER GUIDE

IDS-801 Series Compact Bench Counting Scale. User Manual

Digital Bench Scale. Revision 1.2 August 24, Contents subject to change without notice.

OP-W Series User Manual

Digital Bench Scale. Revision 1.2 September 14, 2000 Contents subject to change without notice.

IGB Series. Operation Manual. Platform Scale. Kg/Lb Specification IMPORTANT

Sartorius Research. R 160 P Electronic Semi-Microbalance

SWITCH, 24 POE PORTS ART. IPSWP240A

Copyright Western Scale Co. Limited. All rights reserved.

MONARCH 9416 XL QUICK REFERENCE

Operation and Service Manual. METTLER TOLEDO XRM Price Computing Scale.

Model PC-400 Portion Control Scale

OV1001 Part No OV1001 HEIGHT ADJUSTABLE TABLE USER GUIDE

It s a Better Way to Weigh!

PX Series Balances. Quick Start Guide. Please download the user manual from

Model SR411i-KG Patient Floor Scale Service Manual Part No. MAN411i-KG_ Page 1 of 16. Patient Floor Scale. Operating and Service Manual

6165 MONEY COUNTING SCALE

PIX-55. Atomic Time Clock. Operation Manual

NEW BenchPro Series Multi-Purpose Digital Bench Scale

AerMonitor AM Aer Monitor User's Manual. Version-0.1

PC 150. Digital Bench Scale. Operation Manual

NAVIGATOR. Digital Weight Indicator. Completely Menu-Driven Set-up Navigation. Bulletin No. 330D. Cardinal Scale Model 225 Weight Indicator

PM3020FSNL/PM3028FSNL 16-Port 10/100Mbps+2 Gigabit TP/SFP Combo PoE Switch 24-Port 10/100Mbps+2 Gigabit TP/SFP Combo PoE Switch

The information contained in this document is subject to change without notice. This document contains proprietary information that is protected by

DRAFT. Customer site gravity factor. Filtering parameters. Five points for linearity correction to ensure maximum accuracy

USER MANUAL. User Manual 17 / 19 LCD. NVP117 / NVP119 1U LCD Console Drawer. Options : - AV / DVI-D / HDMI / Audio - Full Range KVM - DC power

EZ Switch EZ Connect N SMCFS1601/SMCFS2401

PC-150. DIGITAL BENCH SCALE Setup / Operation Manual

GMC-206/215/230 Digital Desktop Weighing Scale Operation Manual

4170 POS System Installation Guide

CONTENTS. PRECAUTIONS Introduction Installation... 7

SLICE Distributor User s Manual February 2017

DMC-1000 Chassis-Based Media Converter

Table of Contents. Laboratory Balances. Instruction Manual - TORBAL AGC Series

In-Motion Axle Scale (K422) Operator Manual

SERVICE MANUAL SD Series Scales

EHC-WF. User/Technical Manual. Contents subject to change without notice

KW serial. User s guide. Bench Scales UGKW-E0302

PLU DATABASE MANAGER OMEGA SERIES COUNTING SCALE

* * Agilent Power Distribution Unit (PDU) Installation Guide

MWP SERIES. High Precision

Kilotech. KRS SWP Series. Counter-top weighing scale. NTEP (USA) and Measurement Canada approved.

WM-25 USER S MANUAL. Manufacturer s Declaration of Conformity

Operating Manual =CENTER OF ZERO =CENTER OF ZERO. FB 2250 Series Instrument by Fairbanks Scales, Inc All rights reserved Rev.

JanusRAID SA-6692J Hardware User Manual

OV-MCR116. Media Converter Chassis System. User s Manual

CANADIAN D.O.C. WARNING

Model 498KL Remote Display Digital Scale User Instructions

LVS 7510 Integrated System Installation and Quick Start Guide for Zebra Printers

D730. Remote Display Installation Manual

Thank you for selecting UTC RETAIL s innovative Model 1170 Point of Sale solution!

ph/orp 300 (Cat. No ) MICROCOMPUTER BASED OPERATION MANUAL ph /ORP/ Temperature CONTROLLER Phone: , Fax:

User Guide Automatic Transfer Switch (ATS)

When using the scale, the following safety precautions should always be followed:

Seedburo Model 9000AG Computer Grain Scale Operating and Service Manual

AL-Series INSTRUCTION MANUAL AL-311 AL-201S. American Weigh Scales, Inc. Analytical Balances American Weigh Scales, Inc. pcs% kgct.

User s Manual. Revision 1.0. Copyright 2016 Maretron, LLP All Rights Reserved

User Manual. Rack Mount Display Monitor - 4K RMP-161-4K17. 7U 17.3 inch Rack Mount Display Monitor

ACT-1B Series Panel Tachometer

Compact Bench Scales NEW. Ranger Simplifying even the most complex industrial applications

Operating Manual. Sigma Counting Scale. CTG-9850 Series (AC Powered) Issue #9 3/ by Fairbanks Scales Inc. All rights reserved

Operation Manual TX10 1/8 DIN Microcomputer Based ph/orp Controller

Stage Right Party Wash FX 1-Watt x54 LED (RGB) with Pie Control

Model Bulk Sampling Scale. User s Manual

MCCB-500 MOLDED-CASE CIRCUIT BREAKER TESTER

VADDIO /CANON BU-SERIES PTZ CAMERAS

OMEGA SERIES COUNTING SCALE

SyncMaster P2050,P2250,P2350,P2050G,P2250G,P2350G. LCD Monitor. User Manual

Weighing Indicator. Features. Description. Applications

Operational Manual Spectrophotometer Model: SP-830 PLUS Metertech Inc.

User Manual USB Port Hub

Operation Manual CX20 1/8 DIN Microcomputer Based Conductivity/Resistivity Controller

AGATE TECHNOLOGY AT-2040

Instruction Manual for. Torbal AGCN Series Balances

OCEAN WATERPROOF WEIGHING SCALE USER MANUAL

Valor TM 3000 Xtreme

Programmable Controller IC697ACC721/724/744

Model 815 User s Manual

HI 6500 series Quick Start Guide

OHAUS SCOUT BALANCE SCALE

Junos WebApp Secure 5.0 Hardware Guide

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

Transcription:

Operator Manual Ultegra Baggage Scale SCB-R9000-B Series 31 x 31 Baggage Scale 2012-2015 by Fairbanks Scales, Inc. 51308 All rights reserved Revision 3 -- 04/15

Ultegra Baggage Scale SCB-R9000-B Series Document 51308 Amendment Record Manufactured by Fairbanks Scales Inc. 821 Locust Kansas City, Missouri 64106 Created 10/2012 Revision 1 10/2012 Released Manual Revision 2 03/2014 Added Gravity Use software update. Revision 3 04/2015 Updated USB information and updated parts list..

Disclaimer Every effort has been made to provide complete and accurate information in this manual. However, although this manual may include a specifically identified warranty notice for the product, Fairbanks Scales makes no representations or warranties with respect to the contents of this manual, and reserves the right to make changes to this manual without notice when and as improvements are made. Copyright 2012-2015 This document contains proprietary information protected by copyright. All rights are reserved; no part of this manual may be reproduced, copied, translated or transmitted in any form or by any means without prior written permission of the manufacturer.

Table of Contents SECTION 1: GENERAL INFORMATION... 7 1.1. Introduction... 7 1.2. Description... 7 SECTION 2: INSTALLATION... 8 2.1. Unpacking... 8 2.2. Connection Descriptions... 8 2.3. Computer Connection... 9 2.4. Connections... 9 2.5. Gravity Use Compensation Setting... 9 2.6. Panel Mount Installation... 11 SECTION 3: OPERATION... 12 3.1. Power-on... 12 3.2. Keys... 12 3.3. Weighing... 13 SECTION 4: CUSTOMER CARE... 14 4.1. Cleaning... 14 4.2. Operator Instrument Prompts... 14 4.3. Troubleshooting... 15 SECTION 5: SPECIFICATIONS... 16 5.1. Technical Specifications... 16 5.2. Environment... 17 5.3. Accessories... 17 04/2015 5 51308 -- Rev. 3

Section 5: Specifications 04/2015 6 51308 -- Rev. 3

Section 1: General Information 1.1. Introduction The Ultegra Series Baggage Scale is a USB powered unit with a capacity of 250 lbs and is constructed of steel. A USB to AC adapter accessory is also available to power the scale. The scale may be placed on a desk, or a bench. 1.2. Description This unit can be powered from any PC that is compliant with version USB 1.1 or later. This includes external hubs, either bus-powered or selfpowered. The scale is identified by a PC as a human interface device (HID) and operates with Windows 2000, Windows XP or later. It also can be powered from a 5VDC USB AC adapter, which comes standard with the scale. 04/2015 7 51308 -- Rev. 3

Section 2: Installation 2.1. Unpacking 1. Remove the scale from the packing box and place on a flat surface where it will be used. 2. Using the bubble level, adjust one or two feet minimally to level the platform. Do NOT adjust all 4 feet. 2.2. Connection Descriptions 1. USB - The USB port is used to power the scale. The included six foot (6') USB cable should be inserted into the scale s USB barrel plug on the back of the unit and then connected to: a USB port on the computer or into a USB hub the included USB to AC power adapter, which is then plugged into a proper outlet. Check the AC receptacle for proper voltages prior to plugging in the adapter 3. REMOTE DISPLAY - To use a remote display, plug the remote display into the connector on the scale base where indicated. 04/2015 8 51308 -- Rev. 3

Section 2: Installation 2.3. Computer Connection 1. USB setup: The USB port will only function with a computer utilizing Windows 2000, Windows XP, or higher operating system. When the scaleconnected USB cable is interfaced to a computer s USB port or USB hub, the computer will prompt a device has been found. 2.4. Connections 2.5. Gravity Use Compensation Setting The SCB-R9000-B has a gravity use compensation setting which must be set based upon the geographical zone in which the scale is being installed. Access this setting by pressing the Program button. The button is located looking at the front of the scale inside the right rear portion of the scale. An access cover must be removed. 04/2015 9 51308 -- Rev. 3

Section 2: Installation 1. The display will show GrU x. This is the Gravity Use Zone. Select the proper zone number for your location. Use the [UNITS] key to toggle to the selection. The choices are: -8, -7, -6, -5, -4, -3, -2, -1, 0, 1, 2, 3, 4, 5, 6, 7, 8, 9, 10 Zone Latitude (degrees) Reference City -8 68.659 Point Hope, AK -7 64.929 Fairbanks, AK -6 61.567 Anchorage, AK -5 58.444 Fort Vermilion, Alberta -4 55.485 High Prairie, Alberta -3 52.638 Coventry, England -2 49.865 Winnipeg, Manitoba -1 47.137 Tacoma, WA 0 44.427 St. Johnsbury, VT 1 41.711 Des Moines, IA 2 38.963 Kansas City, MO 3 36.156 Tulsa, OK 4 33.257 Tuscaloosa, AL 5 30.223 Austin, TX 6 26.992 Navojoa, Mexico 7 23.467 Mazatlan, Mexico 8 19.476 Mexico City 9 14.622 Guatemala City 10 7.326 Bucaramanga, Colombia Press the [ZERO] key to accept the choice selected and the display will indicate AZt 0.5. Press the Program button to return to the weighing mode. This completes setting the Gravity Use Zone setting. 04/2015 10 51308 -- Rev. 3

Section 2: Installation 2.6. Panel Mount Installation 1. Mark the locations for the four (4) mounting screws and cutout for the panel mount display using the dimensions listed on the drawings below. 2. Cutout the outline for the panel (7.38 x 4.0 ) on the surface where it is to be mounted. 3. Drill the four (4) holes approximately 3/16 or (0.188 ) diameter which will secure the panel to the surface. 4. Mount the display. 04/2015 11 51308 -- Rev. 3

Section 3: Operation 3.1. Power-on Because the scale uses special low-power circuitry, no warm-up time is required. Weight readings will be accurate as soon as the unit is powered on and set to zero. When the unit is powered, the liquid crystal display (LCD) will show the software part number and the revision followed by either "0.00", or "------". Dashes are displayed to indicate the scale is registering a weight upon startup. Press [ZERO] to set the display to '0.00' and start weighing. 3.2. Keys The keys for operating the scale are located on the remote display. 1. Pressing the [ZERO] key resets the display to indicate zero (0). The zero range is set at 2% or 5.00 lbs. when set for Canadian use. The zero range is set at 100% or 250 lbs. when set for USA use. 2. The [ZERO] key function will be inhibited if the instrument detects any of the following conditions: Motion on the platform An underload condition An overload condition Outside of programmed zero range 3. Pressing the [UNITS] key toggles the weighing units and annunciators between lb and kg. Verify the units you want to use by noting the arrow indicator on the display. 04/2015 12 51308 -- Rev. 3

Section 3: Operation 3.3. Weighing 1. With the platform empty, press the [ZERO] key. The display will indicate zero (0). Note: The C to the left of the 0.0 indicates true center of zero. 2. Check that the correct units are indicated; press the [UNITS] key to change to lb or kg. 3. Place the item to be weighed in the center of the platform. 4. Read the Gross weight from the display. 04/2015 13 51308 -- Rev. 3

Section 4: Customer Care 4.1. Cleaning Clean by wiping the scale assembly off with a damp cloth only. Do not use running water, harsh chemicals, or allow liquids to drip onto the scale/ display. 4.2. Operator Instrument Prompts Prompt HiCAP LoCAP Description Applied load is greater than 250 lbs/ 113 kg - over capacity. Scale is below normal Zero range - under capacity. - - - - - Indicates the scale is not within the center-of-zero range. Press [ZERO] to go to weigh mode. - - - - - Motion is preventing the scale from entering weigh mode 04/2015 14 51308 -- Rev. 3

Section 4: Customer Care 4.3. Troubleshooting In the event the scale does not function properly, check the following, see appendix for more information: Problem No Display Incorrect Weight [ZERO] key will NOT reset zero Pushbuttons Will Not Operate Display Locked or Inoperative Display Indicates HiCAP No USB Output Possible Source / Remedy Power OFF, plug disconnected, cord damage, faulty USB port or USB to AC adapter. IF you are using a remote display, check the main display first, if it's OK then check the cable plug connection on the remote. Unplug then plug in the power cord to reset the program. Check platform for binding or rubbing, reposition scale so all sides are clear. Ensure correct UNITS are displayed (lb or kg). Remove load, press the [ZERO] key to set the scale to '0.00', then reweigh. Motion on the platform; ensure that the platform is empty. Check platform for binding or rubbing, reposition scale First unplug, then plug in the AC adapter to reset the program. If you are using a remote display, check the main display first, if it's OK then check the cable and plug connection on the remote. First unplug, then plug in the AC adapter to reset the program. If you are using a remote display, check the main display first, if it's OK then check the cable and plug connection on the remote Weight on the platform exceeds 250 lbs, remove load. Check that both cable end connectors are securely fastened. Check the cable for damage. Check the Hub or USB port for problems. 04/2015 15 51308 -- Rev. 3

Section 5: Specifications 5.1. Technical Specifications 1. Capacities: 250 lb x 0.2 / 113 kg x 0.1 2. Rounding: Nearest division per NIST H-44 3. Weight Display: 1.50 inch LCD Display 4. Power On Lockout: Scale will display "------", when power is turned on and weight is present. Press ZERO to establish zero reference. 5. Display update rate: 0.05 seconds. 6. Overcapacity Warning: Displays "HiCAP" for overcapacity 7. Motion Detection: Satisfies H-44 requirements 8. Power Failure Protection: Zero reference, programming, and calibrations are retained if the instrument loses power 9. Load Cell Excitation: 3.3VDC 10. USB Cable Length: Type A/B, 6 feet in length 11. Indicators: lb, kg 12. Dimensions: Platform, Including Feet 31 x 31 x 2.31 13. Auto Zero Tracking: Compensates for gradual buildup of material on platform, factory set at 0.5 divisions 14. Power Requirements: 5VDC, USB to AC adapter 15. Certificate of Conformance: NTEP CC# 98-198; MC# AM-5785 04/2015 16 51308 -- Rev. 3

Section 5: Specifications 5.2. Environment All equipment should be protected from direct sunlight. Relative Humidity 0% to 90% non-condensing. NOT suitable for water wash down. 5.3. Accessories 1. Remote Display Panel Mount 32065 - (ACC-1520-P) RJ45 cable and two (2) function buttons. Not Shown: Remote Display 32647 (ACC-1520PN) panel mount remote display with stainless bezel, no units and zero buttons 2. Remote Display 29595 - (ACC-1520-1) 6.98"W x 3.48"H, 1.29 D, RJ45 cable and two (2) function buttons. Not Shown: Remote Display 32649 (ACC-1520N), wall/pillar mount remote display with ABS housing, no units and zero buttons 3. USB to AC adapter (34232) Input voltage range of 100 to 240 VAC, 50 to 60 Hz. Output, 5VDC, 1.2A 04/2015 17 51308 -- Rev. 3

Section 5: Specifications 4. Remote Display Stand 20301 - A 18" high stand for mounting the Remote Display, ideal for counter-top applications. Remote Display Stand 20301 5. RJ45 Splitter 31162 This accessory is required when connecting more than one (1) remote display to a baggage scale. Two splitters are required for three (3) remote displays and three (3) splitters are required to communicate to four (4) remote displays. 04/2015 18 51308 -- Rev. 3

Ultegra Baggage Scale Manufactured by Fairbanks Scales, Inc. 821 Locust Street Kansas City, MO 64106 www.fairbanks.com SCB-R9000-B Series Document 51308