modu : Local override and indicating units

Similar documents
I/O module, analogue outputs and universal inputs

I/O module, digital outputs (relays), modu550

I/O module, digital outputs (open collector), modu551

I/O module, digital and universal inputs, modu530

EY-IO 534: I/O module, analogue inputs with galvanic isolation, modu534

I/O module, universal, digital, S0 inputs, modu533

EY-RU : Room operating unit, ecounit

EY-RU : Room operating unit, ecounit

EY-RU : Room operating unit, ecounit

EY-EM : Remote I/O module, ecolink

EY-SU 358: Push-button unit for room operating unit, ecounit358

EY-RU : Room operating unit, ecounit

EYE 200: DDC single-room controller, ecos200

modunet292: novanet-ethernet interface

ecounit : Room operating unit with EnOcean wireless technology

EY-AS 525: Modular automation station, modu525

EY-AS 524, 525: Modular automation station, modu524/525

EY-RU 355: Room operating unit, ecounit355

EY-AS 524, 525: Modular automation station, modu524/525

EY-CM 721: Communication module with EIA-232 and EIA-485 interfaces, modu721

EY-CM 721: Communication module with EIA-232 and EIA-485 interfaces, modu721

EY-WS 500: Web server for moduweb Vision and moduweb500 BACnet networks

EY-RU : Room operating unit with EnOcean wireless technology, ecounit

EY-RC 208, 209: Room automation stations, ecos208, 209

Quick reference Software update

EY-AS 521: Compact automation station, modu521

Sauter Systems

AVF 125S: SUT valve actuator with spring return

Content. Product Description

EY-RU : Room operating unit with EnOcean wireless technology, ecounit

EY-RC 500: Room automation station, ecos500

AVM 321, 322: Valve actuator

Manual operation and local visualisation. with SAUTER EY-modulo.

DESIGO 30 Remote operator terminal. for more then one HVAC systems en. menu + esc

Priva Blue ID Analogue output module with manual override AO2m/AO4m

EXOcompact. Third generation freely programmable controllers

Web interface BACnet/IP

RXC39.5. Room controller. Building Technologies. Desigo RXC. Communicating room controller for fan-coil applications

AVM321S, 322S: Actuator SAUTER vialoq AVM 1000 with SAUTER Universal Technology (SUT )

TXM1.8T. Triac module Used for Thermic and motor-driven actuators (AC 24 V) TX-I/O

BACnet/IP Web Interface

TXM1.8RB. TX-I/O Blinds module

Extension module for lighting control

Digital input modules

Priva Blue ID C-Line Mix input/output module MX34

AVM 105S, 115S: Valve actuator with SAUTER Universal Technology (SUT)

EY-RC 311: Programmable controller, ecos311

The low weight, small size, one-touch solution. Portable appliance testing. The Fluke 6000 series PAT testers

Rotary version, three-position control

Universal Modules. Synco 700. Extension modules for use with controls of the Synco 700 family. Use

DESIGO RX Individual room controllers. for fan-coil systems, chilled ceilings and radiators, with LONMARK-compatible bus communications

Switching Actuators N530, 6AX Switching Actuators N532, 10AX Switching Actuators N534, 16/20AX

Power supply module, bus connection module

PXM20-E. Operator unit BACnet auf Ethernet/IP DESIGO PX

RXB39.1. Room controller RXB. Communicating room controller for fan-coil applications FC-13

MIC-2 MKII & MIC-2 MKII DIN, Multi-instrument DATA SHEET

B. AVM321S/AVM322S: 1000N Actuator with analog SUT positioner

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

The low weight, small size, one-touch solution. Portable appliance testing. The Fluke 6000 series PAT testers

Andover ContinuumTM Infinet II

9.5 nominal torque 4.5 W 16 VA. Min. 30 nominal voltage Min. 30 Nm. Reversible with switch By mounting. MIN (minimum position)

Your process requires the utmost attention Our new ACT20C signal conditioners support you in achieving this

PHOENIX CONTACT - 01/2007

Automation stations compact model

SAUTER EY-modulo. Compatibility for a secure investment.

IQ21x Series Controllers

Super universal modules

Products no longer available

PHOENIX CONTACT - 01/2010. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.

MIC-2 Multi-instrument DATA SHEET

TM5C12D6T6L compact I/O expansion block TM5-24 I/0-12 DI - 6 DO transistor - 4 AI - 2 AO

RXM39.1. PL-Link IO Block. Desigo TRA. Use with PXC3 series room automation station

PEAK TM. PEAK TM controllers. Mid-Market BAS Smart equipment controllers. HVAC/R controllers

RMZ782B RMZ783B. Extension Modules. Building Technologies HVAC Products. Synco 700. for heating controller RMH760B

CMC III Universal Sensor

Room unit with PPS2 interface

Priva Blue ID system overview

USB-KNX Interface OCI702. USB-KNX interface with cables and service bag

Products no longer available

MINI-DC-UPS/12DC/4. Extract from the online catalog. Order No.:

DOR6. Components All functions and indications are on the front of the module. Characteristics

UH28C. High Voltage Tester. Product Information Sheet V AC / 100 ma

Extension module Integration of existing PTM I/O modules in Desigo Used with PXC50...D, PXC100...D or PXC200...D

MOD-RI Room Interface Modules with Modbus

Suitable for a wide range of installations with wall-mount, flush-mount and hand-held remote control options.

8 channel universal input and 4 channel Form C digital output

TM172PBG42R Modicon M172 Performance Blind 42 I/Os, Ethernet, Modbus

Resistance measuring module

Neon pr. ph/ ORP measurement. Applications. Description

AV24-MFT AV24-MFT2 AV24-MFT2-C105. Power consumption In operation For wire sizing N 1700 N Control Control signal Y Operating range

SICAM A8000 Series. Operation, telecontrol, and automation in the smallest spaces. siemens.com/sicam-a8000

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

FEC - FAC. Metasys controllers. Complex BAS Programmable controllers. Catalog Page. Field Equipment Controllers

RMZ782B RMZ783B. Extension Modules. Building Technologies HVAC Products. Synco 700. for heating controller RMH760B

WP3x00 MK ll Controller. control systems. All control functions are integrated. Integrated realtime grid measurement

FX-PCX Expansion Input/Output Modules Catalog Page Code No. LIT Issued April 17, 2015

Priva Blue ID Network module SN1/SN2/SN3/SN3t

Multi-Point Gas Detection and Control System

Multi-Point Gas Detection and Control System

MIC-2 MKII, Multi-instrument DATA SHEET

Transcription:

SAUTER EY-lo 5 PDS 92.081 en Product Data Sheet 625...670: Local override and indicating units How energy efficiency is improved SAUTER EY-lo 5 technology: lar, fast and universal Areas of application Digital input display (alarm/status), direct control of digital/analogue outputs of the automation station and I/O le. Features Pluggable elements for direct operation /indicating of the 525 automation station and I/O les Direct operation via switches/slide switches (as per EN ISO 16484-2:2004 'Local priority override/indicating units') Bi-colour s Separate display for manual operation Ready for use out configuration Power supply via 525 automation station or I/O les Part of the SAUTER EY-lo system family Technical description 625, 6 switches (A-0-I), 4 LEDs (bi-colour), 4 slide switches (A-0...100%), 8 LEDs (bi-colour) 630, 16 LEDs (bi-colour) 650 (F001), 6 switches (A-0-I), 4 LEDs (bi-colour) 650 (F002), 3 switches (A-0-I-II), 4 LEDs (bi-colour) 670, 4 slide switches (A-...100%), 8 LEDs (bi-colour) Products Type Description Use EY-LO625F001 Override/indicating unit LEDs (6x A-0-I; 4x LED) (4x A-0...100%; 8x LED) 525 (from hardware index C) EY-LO630F001 Indicating unit (16 LEDs) 525, 530...572 EY-LO650F001 Override/indicating unit LED (6x A-0-I; 4x LED) 525, 550, 551, 571 EY-LO650F002 Override/indicating unit LED (3x A-0-I-II; 4x LED) 525, 550, 551, 571 EY-LO670F001 Override/indicating unit LED (4x A-0...100%; 8x LED) 525, 570, 572 Technical data Electrical supply Permitted ambient conditions Power supply from automation station 525 or Operating temperature 0 45 C I/O le 5.. Storage and transport temperature -25 70 C Humidity 10 85% rh 625 630 670 no condensation Power consumption 1) up to 2 VA/0,7 W up to 1 VA/0.35 W Dissipated power up to 0.7 W up to 0.35 W Installation Current consumption 2) up to 40 ma up to 20 ma Dimensions W x H x D (mm) EY-LO625F001 84 x 92 x 13 Version EY-LO630 670 42 x 92 x 13 EY-LO625F001 6 switches (A-0-I) digital outputs Weight (kg) 4 LEDs alarm/status EY-LO625F001 0.07 4 slide switches (A-0 100%) EY-LO630 670 0.03 analogue outputs 8 LEDs alarm/status Standards, guidelines and directives EY-LO630F001 16 LEDs (alarm/status) Degree of protection IP 30 (EN 60529) EY-LO650F001 6 switches (A-0-I) digital outputs Protection class III (EN 60730-1) PELV 4 LED display alarm/status Environmental class 3K3 (IEC 60721) EY-LO650F002 3 switches (A-0-I-II) digital outputs CE conformity as per 4 LED display alarm/status EMC Directive 2004/108/EC EN 61000-6-1 EY-LO670F001 4 slide switches (A-0 100%) EN 61000-6-2 analogue outputs EN 61000-6-3 8 LED display alarm/status EN 61000-6-4 Factory settings All switches set to 'A' (Auto) Additional information Interfaces Fitting instructions MV 506057 Connection, AS/I/O le Spring-loaded contacts, 9-pole Fitting instructions for accessories 1) On the primary side of base station 525 (230 V~) 4-fold front frame MV P100003733 2) Supply via base station 525 Adaptor MV P100003732 Material declaration MD 92.081 www.sauter-controls.com 1/5

Accessories Type Description 0930240511 Front frame for 4 override/indicating units 0930240540 RJ-45 connection adaptor for front frame override/indicating units Engineering notes The automation station and I/O les of the EY-lo 5 range can be supplemented local override and indicating units (LOI) to enable direct manual operation and indicating of plant components. The function complies the EN ISO 16484-2:2004 standard relating to local priority override/indicating units. Manual output control or override is independent of the automation station's CPU and user program sequence. Installation The units are installed directly in the front of the automation station (2nd installation position) or I/O les. They are 'hot-plug' capable and can be installed and removed during ongoing operations out impeding any functions of the automation station or I/O le. The switches and slide switches on units should be set to Automatic during installation and removal to prevent any unintentional switching operations on outputs. When the unit is removed all outputs are operated using the automatic conditions of the automation station or I/O le. The status flag 'overridden' is activated at every position of manual operation on BACnet objects (AO, BO, MO). The override unit will not function if connected to an incompatible I/O le; there is no danger of destruction. This condition is indicated by all LEDs (red + yellow) flashing. Outputs from automation stations or I/O les that are in manual operating mode may temporarily change condition during a user program download. External installation A front frame (accessory) can be used to enable external installation of the override and indicating unit. This enables one or two 625 or up to four 630 670 units to be connected remotely in each case. On the automation station and the I/O le, adaptor units are used to provide a connection to the front frame. In each case, the electrical connection is created using a commercially available RJ-45 patch cable (Cat. 5 or higher). The distance between AS or I/O le and front frame can be up to 10 metres. Details can be referenced from MV P100003732 and MV P100003733. Summary of functions EY-LO625F001 EY-LO630F001 Double unit; can be used to override and indicate the data points from the 525 automation station (from hardware index C) 4 LED, bi-colour green/red (configurable for event/alarm/status) 6 switches Auto-0-I, green indicator 8 LED, bi-colour green/red (configurable for event/alarm/status) 4 slide switches Setpoint adjuster 0 100%, yellow indicator for manual adjustment Single unit; can be used to indicate the data points from the 530...572 I/O les or the 525 automation station 16 LED s, bi-colour green/red (configurable for event/alarm/status) EY-LO650F001 EY-LO650F002 EY-LO670F001 Single unit; can be used to override and indicate the data points from the 550, 551, 571 I/O les or the 525 automation station 4 LED s, bi-colour green/red (configurable for event/alarm/status) 6 switches Level Auto-0-I indicating green Yellow indicates manual operation Single unit; can be used to override and indicate the data points from the 550, 551, 571 I/O les or the 525 automation station 4 LED s, bi-colour green/red (configurable for event/alarm/status) 3 switches Level Auto-0-I-II indicating green Yellow indicates manual operation Single unit; can be used to override and indicate the data points from the 570 or 572 I/O les or the 525 automation station 8 LED s, bi-colour green/red (configurable for event/alarm/status) 4 slide switches Setpoint adjuster 0 100%, yellow indicates manual operation, red, (freely configurable for event/alarm/status) 2/5 www.sauter-controls.com

Labelling Local override/indicating units are labelled function-specific symbols or numbers. This information may be supplemented by inserting a customised paper label behind the transparent cover on the front. These labels are normally inscribed using text generated from in CASE Suite and are printed out on normal DIN A4 paper using generic printers. s/function LED displays are selected or programmed using CASE Engine, for instance to display alarm/status, limit values, etc. s s Condition Indicator sequence Description green lit continuously/(flashing) Channel active (status DI, BO, MO) red lit continuously Channel active (alarm DI, alarm acknowledged) red pulsating Channel out of service red flashing Channel active (alarm DI, UI, AO - not acknowledged) red + yellow all flashing No communication I/O le or incorrect le type alternating green red/yellow - off Lamp test active (display type has priority) no display Channel status '0', alarm 'normal', no channel allocation or no power supply yellow lit continuously Channel in manual operation (overridden AO, BO, MO) Function occupancy and LED displays Key d: digital LED for digital input (activation configurable for alarm/event) u: universal LED for universal input (activation configurable for alarm/event) ov: out virtual LED freely assignable (virtual activation on alarm/event) r: relay LED for relay (normally open) o: Output LED for digital output (open collector) a: analogue LED for analogue output (activation or limit value transgression) Digit/Number: Channel 625 LED No. Symbol Colour Function/Channel number 525 (from hardware index C) 1 - green/red ov26 2 - green/red ov27 3 - green/red ov28 4 - green/red ov29 6 Level I green/red R20 7 Manual yellow 8 Level I green/red R21 10 Level I green/red R22 12 Level I green/red R23 14 Level I green/red R24 16 Level I green/red R25 1 - green/red d4 2 - green/red d5 3 - green/red d6 4 - green/red d7 5 - green/red d8 6 - green/red d9 7 - green/red d10 8 - green/red d11 10 - red a0 12 - red a1 14 - red a2 16 - red a3 www.sauter-controls.com 3/5

630 LED No. Colour Module/Function/Channel Number 525 530 531 532 533 550 551 570 571 1 green/red d4 u8 d0 u0 u0 ov6 o0 u8 od0 u8 2 green/red d5 u9 d1 u1 u1 ov7 o1 u9 od1 u9 3 green/red d6 u10 d2 u2 u2 ov8 o2 u10 od2 u10 4 green/red d7 u11 d3 u3 u3 ov9 o3 u11 od3 u11 5 green/red d8 u12 d4 u4 u4 o4 u12 od4 u12 6 green/red d9 u13 d5 u5 u5 R0 o5 u13 od5 u13 7 green/red d10 u14 d6 u6 u6 o6 u14 od6 u14 8 green/red d11 u15 d7 u7 u7 R1 o7 u15 od7 u15 9 green/red u12 d0 d8 u8 d8 o8 od8 d5 10 green/red u13 d1 d9 u9 d9 R2 o9 a0 od9 d6 11 green/red u14 d2 d10 u10 d10 o10 a1 od10 d7 12 green/red u15 d3 d11 u11 d11 R3 o11 od11 a0 13 green/red u16 d4 d12 u12 s12 o12 a2 od12 a1 14 green/red u17 d5 d13 u13 s13 R4 o13 od13 a2 15 green/red u18 d6 d14 u14 s14 o14 a3 od14 a3 16 green/red u19 d7 d15 u15 s15 R5 o15 od15 572 650F001 525 550 551 571 1 - green/red ov26 ov6 o6 od6 2 - green/red ov27 ov7 o7 od7 3 - green/red ov28 ov8 o8 od8 4 - green/red ov29 ov9 o9 od9 6 Level I green/red R20 R0 o0 od0 7 Manual yellow 8 Level I green/red R21 R1 o1 od1 10 Level I green/red R22 R2 o2 od2 11 Manual green/red 12 Level I green R23 R3 o3 od3 14 Level I green/red R24 R4 o4 od4 16 Level I green/red R25 R5 o5 od5 *) No function possible on I/O les 530, 531, 532, 533, 570 and 572 650F002 525 550 551 571 1 - green/red ov26 ov6 o6 od6 2 - green/red ov27 ov7 o7 od7 3 - green/red ov28 ov8 o8 od8 4 - green/red ov29 ov9 o9 od9 6 Level I green/red R20 R0 o0 od0 7 Level II green/red R21 R1 o1 od1 8 - - - - - 10 Level I green/red R22 R2 o2 od2 11 Level II green/red R23 R3 o3 od3 12 - - - - - 14 Level I green/red R24 R4 o4 od4 15 Level II green/red R25 R5 o5 od5 16 - - - - - *) No function possible on I/O les 530, 531, 532, 533, 570 and 572 4/5 www.sauter-controls.com

670 525 570 572 1 - green/red d4 u8 u8 2 - green/red d5 u9 u9 3 - green/red d6 u10 u10 4 - green/red d7 u11 u11 5 - green/red d8 u12 u12 6 - green/red d9 u13 u13 7 - green/red d10 u14 u14 8 - green/red d11 u15 u15 10 - red a0 a0 a0 12 - red a1 a1 a1 14 - red a2 a2 a2 16 - red a3 a3 a3 *) No function possible on I/O les 530, 531, 532, 533, 550, 551 and 571 Fr. Sauter AG Im Surinam 55 CH-4016 Basel Tel. +41 61-695 55 55 Fax +41 61-695 55 10 www.sauter-controls.com info@sauter-controls.com Printed in Switzerland www.sauter-controls.com 71920810035/5 03