Safety. Features 1 ID: Make all the connections before you plug in the main power. DMX512 Controllable and RDM Configurable

Similar documents
Flat Par 9 LEDs. battery power, Wirelss, Remote Control, RGBWA-UV 6-in-1 USER MANUAL. Please read over this manual before operating the light

User Instructions. American DJ

LED DANCING FLOOR User Manual

RE-82 RACK MOUNT DIMMER OWNERS MANUAL. 8 X 2400Watts. Revision /29/2007

Robot Light V2. User Manual

TourPro RGBAW Stagebar USER MANUAL

LED PAR56 Order Code: P56-151

PROFESSIONAL SHOW LIGHT

FT-20 Fire Training Fog Machine User Manual English

Z-350 FAZER USER MANUAL

4-CHANNEL DMX WALL-MOUNTED CONTROLLER

TRANSCENSION Show Control

DMX 15-LED Dimmer 75 A, 20 V DMX 30-LED Dimmer 75 A, 30 V DMX 30-LED Dimmer 75 A, 100 V. User s manual

ALEPH MATRIX1 64 RGB PIXEL PANEL SYSTEM FOR EFFECT LIGHTING AND SIGNAGE PLEASE MAKE SURE THE POWER PASS-THROUGH CURRENT DOES NOT EXCEED 10 AMPS

LED SPIDER MOVING HEAD LIGHT

12X3W UV LEDS PROJECTOR LED- 12 USER GUIDE

Cobra Dimmer Master DMX Controller User Manual

FT-20 Fire Training Fog Machine User Manual English

GLX LED STAGE 4 MANUAL GLS-4 LED STAGE 4. owners manual

Power LED Beam 56 Narrow

BS 287 DUAL CHANNEL POWER SUPPLY. User Manual. January 2017 V1.0

SP-1500 DMX MK II Strobe

DUAL LASER PACK & CONTROLLER USERS MANUAL

English. Professional Light Controller USER'S MANUAL. Please read this manual carefully before use!

DarkFX Spot 670 User Manual English

MODEL 805 USER MANUAL

Z-380 Fazer Machine User Manual English

NSI DIGITAL DIMMING SYSTEM DDS 5300 / 5600 DIMMER PACK

LED Accu Penta 9x12W RGBWAU

TOT Series Manual. North American and International Models - without optional faceplate. Receptacle Panel of International Models, CE model shown

1 Channel Strobe Controller ORDERCODE 40226

RoscoLED Tape Variable PWM DMX Decoder User Guide

STAGE TRI-PAR 18TC CP-18TC. User Manual. Please read the instructions carefully before use

FLEX BEAM V8. User Manual Please read the instruction carefully before use

Beam Stage Light (RGBW)

APT20. User Manual.

TOT Series Manual. North American CE and UK Models. CE Models. UK Models. North American Models

Party Dimmer IEC ORDERCODE 50324

LED W RGBA User Manual

7x15W 4IN1 Infinity Rotation LED Pixel Bar. This product manual contains important information about the safe

Blitzer Strobe. User Manual. Order code: EQLED366

Gobo Projector XP 80W

Blitzer RGB Strobe. User Manual. Order code: EQLED365

Slimline CW & WW Series

TB-1230 QW. User Manual Please read the instruc on carefully before use

LED BEAM 300 LED-MB50. User. Guide. Professional Entertainment Technology

Professional Entertainment Technology LED BEAM 300 LED-MB50. Innovation, Quality, Performance 23-

10W LED PIN SPOT. User Manual LED-PS10D W. Innovation, Quality, Performance. Professional Entertainment Technology 11-

Stage Fog Machine User Manual

Octostrip ORDERCODE 42220

Professional Entertainment Technology LED BEAM 300 LED-MB50. User. Guide

DNG-200 LOW FOG GENERATOR USER MANUAL DNG-200 低煙機使用說明書

Microbar COB System. User Manual. Order code: EQLED137

DM-X Channel DMX Controller. Item ref: UK User Manual. Version 2.0

Crossfire. User Manual. Order code: EQLED061

Party Par. User Manual. Order codes: EQLED015 - Black housing EQLED015B - Polished housing

Stage Right Party Wash FX 1-Watt x54 LED (RGB) with Pie Control

StagePar COB TRI 4 CKU

order code: EQLED40 user manual

DMX PRO 4CH DMX DIMMER PACK USER S MANUAL

MONOPRICE. ShowPony 12-Watt LED Derby FX Light (RGBW) User's Manual P/N

LED BEAM MOVING HEAD FL x3W User Manual

Eternal Lighting. Premier150 Spot. User Manual

RGB Power Batten. User Manual. Order code: EQLED032

Owner s Manual. Isolate. Restore. Inspire! Power Conditioners Audio / Video Power Isolation Units Rack Mount / Consumer Series

BS 181 SINGLE CHANNEL POWER SUPPLY USER MANUAL

W-715 Fog Jet USER MANUAL English 2013 Antari Lighting and Effects Ltd.

LED MOVING HEAD FLEX BEAM K8 RGBW. User Manual. Please read the instruction carefully before use

S-100X / S-200X Snow Machine User Manual

1 Channel Sliding Profile Dimmer ORDERCODE 50425

BW-108. Building Wash BW-108. User Guide. Advanced LED Technology

36LEDs Par Light. User Manual

Spectrum Laser. User manual UK. Version 1.0

Vector Beam White. User Manual. Order code: LEDJ265

FUSION SPOT MKII EQUINOX. Contents. User Manual. Order codes: Black housing - EQLED Safety Instructions. 2. Features & Specifications

CUBE3 RGB TRI LED User Manual (Battery Powered DMX LED Fixture)

Revo 120. User Manual

User Manual Charter Street Los Angeles CA

DLA. DMX512 Analyzer. DLA Users Manual SV2_00 B.lwp copyright ELM Video Technology, Inc.

AMP20. User Manual.

Ostar Eye K6. Beam and Kaleido Effects. User manual. Please read the instructions carefully before use

w w w. p r o l i g h t. c o. u k TRI PAR 64 Order code: LEDJ48 - Black Order code: LEDJ49 - Polished USER MANUAL

SAMURAI SCAN 50 LED-SC50D. User Guide. Innovation, Quality, Performance. Professional Entertainment Technology 19-

CUBE RGBA User Manual. Battery Powered Wireless DMX LED Fixture Or Battery Powered LED Fixture (Without DMX Built inside)

COB100/200W 2in1/3in1 led Par Light

LED PANEL. User Manual Please read the instructions carefully before use LED-7TC. Innovation, Quality, Performance 15-

Colour Burst Order code: LEDJ01 USER MANUAL

ALO Duo Roll DMX LED barrel scanner with dual light source

Professional Entertainment Technology. imove 50SR. Innovation, Quality, Performance 21-

User Manual. JS-ICON 624 PACK Portable Dimmer Pack. JOHNSON SYSTEMS INC. Spring

Page 1 of 6 FXLD1218FRP5I LED FIXTURE Version 0.1 OWNERS MANUAL 08/01/2016

4X30W TRI COB LEDS LIGHTING BAR WITH LCD DISPLAY

LCU-2S Liquid Supply System User Manual English

LED PANEL. User Manual Please read the instructions carefully before use LED-212RGB TABLE OF CONTENTS. 1. Safety Instructions

xbrick Full-Colour 16 3W LED floodlight user manual

User Manual Equinox 2m Flight Cased DMX LED Flame Machine Order code: FLAM12

Springtree Spatial Wash COB RGBW

Please read the instructions carefully before use LED PYRAMID LED-904D. Innovation, Quality, Performance 15-

User Instructions. American DJ Charter Street Los Angeles Ca

Amplified subwoofer - 12" - 400W RMS

Transcription:

Features DMX512 Controllable and RDM Configurable Designed for driving LED strips through 6 high power 12 and 24 Volts output units available Easy addressing interface (physical switches and RDM) Isolated DMX input 6 x 5 Amps constant voltage controllable outputs 250 watts total output power Fused outputs with surge protection Power, status and output LED indicators Stand-alone output sequences (if configured, no external controllers required) Up to 8 units stackable using standard 19 modular rack accessory (sold separately) Ideal for white or RGB LED Tapes Standard IEC mains input connector Auto-selectable Multi voltage mains input Safety Make all the connections before you plug in the main power Do not expose this the ALEPH CV DRIVER to rain or moisture, doing this will void the warranty Do not spill water or other liquids into or onto the unit Check that the local power outlet matches that of the required voltage (110 240V AC) Do not remove the cover whist the unit is powered Never plug this unit in to a dimmer pack Always be sure to mount this unit in an area that will allow proper ventilation. Allow about 6 (20 cm) between this device and a wall Make sure ventilation holes are clean and unobstructed Do not attempt to operate this unit, if it becomes damaged This unit is intended for indoor use only Always mount this unit in safe and stable manner Power-supply cords should be routed so that they are not likely to be walked on or pinched by items placed upon or against them, paying particular attention to the point they exit from the unit The driver should be situated away from heat sources Make sure the unit is dry and there is no fluids residue before powering the unit after cleaning 1

Load(%) Firmware Update Surge Protections Updating the firmware to the ALEPH CV DRIVER requires an ENTTEC USB Pro or a Pro Mk2 widget plugged in to a PC USB port and to the ALEPH CV unit through a standard 5 pin DMX cable. Please download and install the CV_Update_Firmware application from www.enttec.com website, connect the widget to the unit, power it up and run the application. Whilst performing the updating process the status LED should stop blinking for about 35 seconds. The process will be finished when the status led starts blinking again. To make sure the process has been successful and check the firmware version, please look at the Software Version ID field using an RDM tool such us ENTTEC RDM Controller software which can be downloaded for free from ENTTEC website. Thermal Management ALEPH CV DRIVER (RevB onwards) has an in-built thermal control system. It constantly monitors the hardware s internal temperature and acts on the condition of overheating. When internal temperature is higher than the limit, the thermal control system will gradually lower the of all the connected LED strips or loads to cool down the driver. Once the internal temperature is within the limit, the driver will resume its normal operation. The below graph shows a relationship between ambient temperature versus output loads: ALEPH CV DRIVER (Rev B) has enhanced the surge protections for all the output. This feature designed to prevent unexpected high voltages to permanent damage the. The below chart shows its operating parameters: Item Surge Protection Range Protection Time Please note: Surges are usually caused by installation issues such as unnecessary long cables, short-circuit and connecting the 4 pin XLR connector when driver is on etc. It is highly recommended that users check the connections before turning on the driver. LED Status The CV driver comes with eight LED indicators located in the front panel. Two set of RGB LEDs on the bottom indicate the channel activities. The orange LED on top section indicates the internal power supplies are working properly. The top green LED next to orange LED indicates the driver status and should be constantly flashing. Please refer to the following table for information about current operating status: Flashing Frequency 0.5 Hz Idle 2 Hz Overheating Unit Status 8 Hz Receiving data from DMX Dip Switches Configuration 26VDC-40VDC 1s (Load inductance < 400mH) 100 80 60 40 20 0 Output Derating 0 10 20 30 40 50 Amibient Temperature ( C) The ALEPH CV DRIVER counts with a 10 ways dip switch which defines the behaviour of the unit, being switches # 1 to 9 the address and switch # 10 the mode. The two modes defined by switch # 10 are called Standard and Auto where in standard mode the unit will need and external DMX source to control the lights and in auto mode the unit will generate pre-defined sequences in stand-alone manner. 2

Please refer to the following table which describes how to use the switches. The binary number set in switches #1 to 9 will define the sequence number. The following table shows some examples of pre-defined sequences. All OFF CH1 full Auto Mode (Switch#10 is ON) All output will be dimmed OFF (Blackout) CH1 output will be driven to full RDM (remote Standard Mode (Switch#10 is OFF) When all the address digits (1 to 10) are set to OFF the address must be defined through RDM Address is: 001 Address is: 002 CH4 full CH4 output will be driven to full Address is: 2+4=006 CH6 full CH6 output will be driven to full Address is: 256+1=257 RDM Capabilities All ON All output will be driven to full The ALEPH CV DRIVER has full RDM capabilities and you can read/write them by using any standard RDM tool. The ENTTEC RDM Controller software can be downloaded for free from ENTTEC website and be used in combination with a DMX USB PRO, RDM USB PRO or a PRO MK2 widget. RDM addressing will be only available when all configuration switches are all set to OFF position. Read only supported fields RDM Protocol Version Device Model ID Software Version ID Sensor DMX Footprint Sensor Count Manufacturer Label Supported Parameters Count 3

User configurable supported fields Lamp On Mode o [OFF] Stays off until instructed o [DMX] Strikes upon receiving DMX o [ON] Strikes Auto at Power Up DMX Personality o 8 Bit 6-Channel Mode o Extended 9-Channel o 16 Bit 12-Channel Mode DMX Start Address PWM Adjustment Identify Device Factory Defaults Channel Distribution (DMX Personalities) The CV Driver handles each DMX channel as an RDM subdevice, so you can assign independent addresses to each channel which do not have to be consecutive. It is even possible defining several to the same DMX address. Strobe Frequency 000-010 011-252 253-255 Master Dimmer 000 255 000-255 Output Observed Full Output depending on current CH1- CH6 and Master Dimmer channel. Varies strobe frequency where 011 is the lowest and 252 the highest (still keeps the colour and master dimmer values from the other ) Full Output depending on current CH1- CH6 and Master Dimmer Output Observed All outputs will be OFF (dimmed to 0%) Full Output (100%) depending on current CH1-CH6 and Strobe Frequency. Dims all merging them with the current CH1-CH6 and Strobe Frequency, where 000 is 0% and 255 is 100%. Changing Fuses The ALEPH CV DRIVER has six Fast 5X20mm, 6 Amps, UL glass fuses for protecting the outputs and can be changed by removing the metal lid following this steps: 1- Un-power the unit. There are mains voltages inside, so the unit must be never operated without the lid. 4

2- Detach the metal lid by removing the 10 Philips type screws. Please note that there is a wire running from the base to the lid which need to be watched during the procedure: 3- Locate and change the desired fuse in the main controller board using this diagram: Specifications Due to continuous improvements and innovations of all ENTTEC products, specifications and features are subject to change without notice. Item Input Voltage Input Frequency Maximum Total Output Power Maximum Current Per channel Output Type 110 240V AC 50/60Hz 250 Watts 5 Amps Common Anode Output Channels 6 Control Input DMX512 & RDM E1.20 4- Place the lid back and the unit will be ready to be repowered. Dimensions The ALEPH CV DRIVER is designed to fit the modular rack accessory (sold separately) which allows stacking up to 8 units. Personalities Smart Dimming Cooling Method Ambient Working Temperature Connectors Protection Rating Net Weight 3 DMX distributions: 6, 9 and 12 14 bit internal dimming mapped to 8 bit S curve Forced air (temperature-regulated for low noise) 5 to 35 C 1x 5-Pin Male XLR for DMX input 1x 5-Pin Female XLR for DMX output 2x 4-Pin Female XLR for output 1x 3-Pin IEC C14 Male Socket 10Amps for mains IP20 2.4 Kg 5 Shipping Weight 2.8 Kg

Stackable Modular Rack (Accessory) The modular rack (sold separately) allows up to 8 ALEPH1 CV units to be stacked up using only 3 standard rack units (3RU). Also has an in-built fan at the rear side. Screw Terminal Output (Accessory) The converter from 4 pin XLR to screw terminal (sold separately) allows easy installation by using a flat screw driver, avoiding the need of wiring and soldering. Ordering Information The ALEPH CV DRIVER and compatible products can be ordered from our website or through your ENTTEC dealer using the following part numbers. Different voltage and protocol units are made under special order (please contact us). Part Number Description 73520 ALEPH CV DRIVER (24V) 73522 ALEPH CV DRIVER (12V) 73526 XLR 4PIN TO SCREW TERMINAL OUTPUT CONVERTER 73530 A1-8 WAY CV RACK (240V AC) 6