The LED display (1) turns green when the load is switched on.

Similar documents
1 Safety instructions. 2 Intended use. 3 Product characteristics. 4 Operation. LB management. Universal rotary dimmer LED

KNX/EIB Flush-mounted universal dimming actuator 210 W. 1 Safety instructions. 2 Device components. Order-No. : Operating instructions

1 Safety instructions. 2 Device components. 3 Function. Control unit, 1-10 V 3-gang. Order-No. : Operating instructions

1 Safety instructions. 2 Device components. 3 Function. DALI Tronic transformer 105 W. Order-No. : Operating instructions

picture 1: Device components

KNX/EIB KNX Blind actuator. 1 Safety instructions. 2 Device components. Blind actuator 4-gang 24 V DC Order-No. :

KNX/EIB Push button sensor 3 Plus F Safety instructions. 2 Device components. 3 Function

1-channel shutter actuator 6A UP Installation Instructions

Universal dim actuator 1gang RMD Universal dim actuator 2gang RMD Universal dim actuator 4gang RMD

Figure 1: Device components

Bus coupler 3 Bus coupler 3 external sensor Order No

Mounting and Operating Instructions

1 Safety instructions. 2 Device components. 3 Function. Control unit 1-10 V, 3-gang. Art.-No.: 2193 REG. Operationsmanual

Electrical devices may only be mounted and connected by electrically skilled persons.

picture 1: Device components

Product and functional description

1 Safety instructions. 2 Device components. 3 Function. DALI transformer W. Art.-No.: D SNT 105. Operationsmanual

1 Safety instructions. 2 Device components. 3 Function. IC00P01DAL - DALI gateway. DALI gateway. Operating instructions

Product and functional description

Operating Instructions

Product and functional description

Water-protected surface-mounted push-button bus coupler Order No , , ,

The Energy Savers. Universal dimmer switches, capacity enhancer and 1-10V controllers. Selection table for universal dimmer switches,

Product and functional description

KNX DALI Gateway Plus - User Manual

Operating Instructions. DALI-Gateway

LINEAR LED DRIVERS. PrimeLine DALI dimmable. PrimeLine DALI DIMMABLE , , , , ,

UNIVERSAL DIMMER DIM02SA/500U

UNIVERSAL DIMMER DIM02SA/500U

UNIVERSAL DIMMER DIM04SA/500U

Structure of the device. Push-button sensor module. Ref.-no.: 4008 TSM Safety instructions

COMPACT LED DRIVERS. PrimeLine DALI dimmable & Selectable Current (Dip Switch) PrimeLine DALI DIMMABLE & SELECTABLE CURRENT (DIP SWITCH)

Installation Instructions

Four-channel Venetian blind actuator 230 V Installation Instructions

The Energy Savers. Universal Dimmer Switches, capacity enhancer and 1-10V controllers. Selection table for universal dimmer switches,

Switching Actuators N530, 6AX Switching Actuators N532, 10AX Switching Actuators N534, 16/20AX

Product manual. Mylos KNX 350w Dimmer 2CSYK1205C/S

Rev Operating Instructions Busch-Dimmer. Potentiometer U-101

4 CHANNEL UNIVERSAL DIMMING ACTUATOR

The bodyguards. Current relay, mains monitoring relay, currentlimiting relay and mains disconnection relay

1 Safety instructions. 2 Device components. Gira Control 9 Client 2. Gira Control 9 Client 2 Order no.: Operating instructions

Product and Applications Description. Application Programs. Note. instabus EIB Technical Product Information. June 2005

Operating Instructions. Power-DALI-Potentiometer

PSR-PC50. SIL 3 coupling relay for safety-related switch on. Data sheet. 1 Description

Product and Applications Description. Example of Operation. Installation Instructions WARNING. Note. Application Programs

CC COMPACT DIP SWITCH

Control unit for lux control, MDRC Type: SL/S 50.1, GH Q R0001

PSR DC/ESP4/2X1/1X2

PSR UC/ESAM4/3X1/1X2/B

LINEAR LED DRIVERS. EasyLine Simple Fix. EasyLine SIMPLE FIX , , , , ,

COMPACT LED DRIVERS. EasyLine Simple Fix. EasyLine SIMPLE FIX , , , , , , , , ,

AQStation Dimmer. Manual. LAN/Wi-Fi-based-control. Typ: AQS Dimmer black Order-No.: Typ: AQS Dimmer white Order-No.:

DALI Professional Controller-4. Control unit Operating instructions

ETD-BL-1T-230(-PT) Multifunctional time relay with various functions and adjustable times. Data sheet. 1 Description

COMPACT LED DRIVERS. ComfortLine Residential. ComfortLine RESIDENTIAL , , ,

COMPACT LED DRIVERS. EasyLine Selectable Current (Output Terminal) EasyLine SELECTABLE CURRENT (OUTPUT TERMINAL) , , ,

Operating voltage Maximum

PSR-SCP- 24DC/URM4/4X1/2X2/B PSR-SPP- 24DC/URM4/4X1/2X2/B

SAFETY RELAY YRB-4EML-31S MAIN FEATURES

K-BUS R. Dimming Actuators. User manual-ver. 4 KA/D KA/D KA/D KA/D 04.T1.1 ADTV-04/16.1 KA/D 04.L1.1 ADLD-04/

A1 A2 A3 A4 A5 A6 A7 A8 A9 A10 A11 A12 A13 A14 A15 A16 Controls:

High-performance switching actuators

For Models #2384W/I (and Slave Remote Dimmer Model #1135W/I)

COMPACT LED DRIVERS. EasyLine Simple Fix. EasyLine SIMPLE FIX , , , , ,

USER MANUAL INSTALLATION MANUAL. Isolation transformers. ITR Isolation Transformer 7000 W 230V/32A

COMPACT LED CONVERTERS 48 V

LINEAR LED DRIVERS. ComfortLine Industry Selectable Current (LEDset) ComfortLine INDUSTRY SELECTABLE CURRENT (LEDset) ,

Remote dimmer 1000 W

PSR-SCP- 24DC/SDC4/2X1/B PSR-SPP- 24DC/SDC4/2X1/B

LinkRay LED Drivers EasyLine With Selectable Current , Typical Applications

AB0602D ARCHITECTURAL BALLAST DRIVER. Version Date 06/25/2012

QUINT-PS/ 1AC/24DC/20/CO

LINEAR LED DRIVERS. ComfortLine NFC. ComfortLine NFC , , ,

Control unit SG-EFS 104/2W. EN Operating instructions. Innovative by tradition. Version SG-EFS 104/2W 24 V=/~

PSR-MS60. Safety relay for emergency stop, safety door and light grid monitoring. Data sheet. 1 Description

Instruction Manual. Contents

1 Safety instructions. 2 Device components. KNX Touch/Glass sensor comfort

Siemens Spares. RL 513D23 Switching actuator (relay), 3 x 6A. Technical Product Information

DP500IP 1AC/ DP500IP 3AC Manual

Easy Analog RNB130. Technical Information. Primary switched-mode power supply

FutureNow FNIP-6x2AD

LED Driver Compact dimming

Product documentation

Eltako Powerline The ideal supplement to the Eltako Wireless Building System with EnOcean

Operating Instructions

QUINT-PS/ 1AC/24DC/ 5

Product documentation

PRODUCT MANUAL LUZEN PLUS. Universal Dimmer ZN1DI-P400. Program version: 3.0 Manual edition: a

2CKA001473B Product manual LED dimmer 4x210 W, MDRC UD/S

Polymer Electric. Operating Instructions. Control Unit SG-RST 153. Version 0.3

Power Supply Systems KNX PS640 and KNX PS640 USB

Product and Applications Description. Note. Example of Operation. Installation Instructions. Application Programs WARNING

EMD-FL-C-10. Electronic monitoring relay for overcurrent and undercurrent monitoring of direct and alternating current in single-phase networks

Power Supply HARTING pcon

XU1-E Earth fault voltage relay. (August 1996) Manual XU1-E (Revision New)

AHD-RB6 Electronic Circuit Breaker (ECB) Type C

Product and functional description. Application Program. instabus EIB Technical product information. April (6 x AC 230 V / 0,05 A)

Residual Current Devices FRCdM Type B, B+ and Bfq Digital

MINI-DC-UPS/12DC/4. Extract from the online catalog. Order No.:

Demonstration Case BENNING DB 1

Transcription:

Order no.: 2365 00 Operating instructions 1 Safety instructions Electrical devices may only be mounted and connected by electrically skilled persons. Serious injuries, fire or property damage possible. Please read and follow manual fully. Danger of electric shock. Always disconnect before carrying out work on the devise or load. Danger of electric shock. Device is not suitable for disconnection from supply voltage. The load is not electrically isolated from the mains even when the device is switched off. Risk of destruction if the set operating mode and load type do not match. Set correct operating mode when connecting or exchanging the load. Fire hazard. For operation with inductive transformers, each transformer must be fused on the primary side in accordance with the manufacturer's instructions. Only safety transformers according to EN 61558-2-6 may be used. These instructions are an integral part of the product, and must remain with the end customer. 2 Intended use Intended use Switching and dimming of lighting Mounting in a sub-distribution unit on DIN rail according to EN 60715 Operation is performed using the buttons, 2-wire or 3-wire extension with button cover, rotary dimmer extension or push-button with NO contact 3 Product characteristics Device works according to the leading edge phase control or trailing edge phase control principle Automatic or manual setting of the dimming principle suitable for the load Display of the set operating mode by means LED Switch-on via bulb-preserving soft start Switch on with last saved brightness or saved switch-on brightness Switch-on brightness can be saved permanently Minimum brightness can be saved permanently Electronic short-circuit protection with permanent switch-off after 7 seconds at the latest Electronic over-temperature protection Power extension possible by means of power boosters. 4 Operation These instructions describe operation using the buttons on the device and using a 2-wire or 3- wire extension with a button cover or push-button as extension. Switch light The LED display (1) turns green when the load is switched on. Press the button n or button cover briefly: Light is switched on at the last set brightness or the stored switch-on brightness. Press the button o or button cover briefly: The light is switched off. 3-wire extension: Press top to switch on, press bottom to switch off. 1 / 7

Adjust the brightness Light is switched on. Long press the button n or button cover at the top. The light gets brighter up to maximum brightness. Long press the button o or button cover at the bottom. Light gets darker to minimum brightness. Switch light on with minimum brightness Long press the button o or button cover at the bottom. Light switches on at minimum brightness. Long press the button n or button cover at the top. Light switches on at minimum brightness and gets brighter. Save switch-on brightness In the state as supplied, the switch-on brightness is set to maximum brightness. Set light to the required brightness. Press the button n and o or button cover over the entire surface for longer than 4 seconds. Switch-on brightness is saved. For confirmation, the light is switched off briefly and switched on again. Delete switch-on brightness Briefly press the button nor button cover: Light switches on at the saved switch-on brightness. Press the button n and o or button cover over the entire surface for longer than 4 seconds. The switch-on brightness is deleted. For confirmation, the light is switched off briefly and switched on again. Switching on takes place at the last brightness value set. Operation via push-button as extension Press push-button briefly: Light is switched on or off at the last set brightness or a stored switch-on brightness. Long press on the push-button when switched on: Set the brightness. The dimming direction is changed with each new long actuation. Long press on the push-button when switched off: Light switches on at minimum brightness and gets brighter. Saving or deleting the switch-on brightness is not possible. 5 Information for electrically skilled persons 5.1 Fitting and electrical connection DANGER! Mortal danger of electric shock. Disconnect the device. Cover up live parts. 2 / 7

Fitting and electrical connection (1) LED display (2) Release the (3) 3-wire, rotary dimmer extension (4) 2-wire extension (5) Push-button, NO contact Figure 1: Connection diagram When operating multiple dimmers or power boosters in a sub-distribution, maintain a distance of 1 module, approx. 18 mm, between the devices in order to prevent overheating. Connect 600 Watt LED lamps or compact fluorescent lamps at most per 16 ampere circuit breaker. When connecting transformers, observe the data of the transformer manufacturer. Our dimmers take into account the different electronic characteristics of most LED lamps found on the market. However, it cannot be guaranteed that in individual cases the desired results may not be achieved. Lit push-buttons must have a separate N terminal. 3 / 7

Figure 2: Clampable conductor cross-section Reset the overheating protection / short-circuit protection Disconnect the dimmer from the mains supply. 5.2 Commissioning Operating mode: Universal, R,L,C,LED (factory setting) Automatic calibration to the load, dimming principle, trailing edge phase control, leading edge phase control or LED leading edge phase control Incandescent lamps, HV halogen lamps, dimmable HV-LED or compact fluorescent lamps, dimmable electronic or inductive transformers for halogen or LED lamps. Operating mode: LED trailing edge phase control, { The connection of inductive transformers is not permitted. Incandescent lamps, HV halogen lamps, electronic transformers for halogen or LED lamps that can be dimmed according to the trailing edge phase control principle, HV-LED or compact fluorescent lamps that can be dimmed according to the trailing edge phase control principle. Operating mode: LED leading edge phase control, The connection of inductive transformers is not permitted. Incandescent lamps, HV halogen lamps, electronic transformers for halogen or LED lamps that can be dimmed according to the leading edge phase control principle, HV-LED or compact fluorescent lamps that can be dimmed according to the leading edge phase control principle. Setting operating mode and minimum brightness Precondition: Load is switched off. Press both buttons n and o (2) for longer than 10 seconds, until LED (1) lights up (Figure 1). Release both buttons n and o (2). Figure 3: Assignment of LED colour to dimming principle Keep briefly pressing button n or o (2) until the necessary operating mode is selected. The LED (1) lights up in the colour of the selected operating mode (Figure 3). Press and hold down both the buttons n and o (2). The LED (1) flashes in the colour of the selected operating mode. Light switches on at the lowest brightness and slowly becomes brighter. When changing the operating mode to universal, the calibration to the load is first performed. Keep both buttons (2) pressed. 4 / 7

In the lowest dimming position, a lamp light must be visible. Once the desired minimum brightness is reached, release both buttons n and o (2). LED (1) lights up in the colour of the selected operating mode, operating mode and minimum brightness are set. Optionally change the minimum brightness again: Press both buttons n and o (2) for longer than 1 second. Light switches again to the lowest brightness and slowly becomes brighter. Save the settings: Briefly press the button n or o (2) or do not press for 30 seconds. LED (1) turns green. 6 Technical data Rated voltage AC 230 V~ Mains frequency 50 / 60 Hz Ambient temperature -5... +45 C Standby power approx. 0.3 W Power loss approx. 3.8 W Connected load at 45 C (Figure 4) Figure 4: Connected load Operating mode {: Max. connected load for HV-LED lamps typ. 3... 200 W, electronic transformers with LV-LED typ. 20... 200 W. Mixed load ohmic-inductive ohmic-capacitive capacitive-inductive Ohmic and HV LED Ohmic and compact fl lamp. Power specifications including transformer power dissipation. Operate inductive transformers with at least 85% nominal load. 20... 420 VA 20... 420 W not permitted typ. 3... 100 W typ. 3... 100 W For ohmic-inductive mixed load, maximum 50% proportion of ohmic load. Otherwise incorrect calibration of the dimmer may result. Power reduction per 5 C in excess of 45 C -15 % Number of extension units 2-wire, push-button unlimited 3-wire, rotary dimmer extension 10 5 / 7

Power boosters Total line lengths Extension pwr cable Fitting width See power booster instructions max. 100 m max. 100 m 36 mm / 2 module 7 Troubleshooting Connected LED lamps or compact fluorescent lamps switch off in the lowest dimming position or flicker Cause: The set minimum brightness is too low. Increase minimum brightness. Connected lamps do not switch on in the lowest dimming position or only after a delay Cause: The set minimum brightness is too low. Increase minimum brightness. Connected LED lamps or compact fluorescent lamps flicker or buzz, no correct dimming possible, device buzzes Cause 1: Lamps are not dimmable. Check manufacturer's instructions. Exchange lamps for another type. Cause 2: Operating mode (dimming principle) and lamps do not optimally match. Check operation in another operating mode, reduce connected load as well if necessary. Set the operating mode manually. Exchange lamps for another type. Connected LED lamps or compact fluorescent lamps in the lowest dimming position are too bright; dimming range is too small Cause 1: The set minimum brightness is too high. Reduce minimum brightness. Cause 2: Operating mode (dimming principle) does not optimally match the connected HV-LED lamps. Check operation in another operating mode, reduce connected load as well if necessary. Set the operating mode manually. Exchange HV-LED lamps for another type. The dimmer switches the load off briefly and then on again. Cause: short-circuit protection has tripped but now there is no longer a fault. The dimmer has switched off and the load cannot be switched on again Cause 1: overheating protection has tripped. Disconnect dimmer from mains by switching off circuit breaker. LED trailing edge phase control: Reduce the connected load. Exchange lamps for another type. LED leading edge phase control: Reduce the connected load. Check operation in the LED trailing edge phase control setting. Exchange lamps for another type. Let dimmer cool down for at least 15 minutes. Switch circuit breakers and dimmer on again. Cause 2: Surge protection has triggered. LED trailing edge phase control: Check operation in the LED leading edge phase control setting, reduce connected load as well if necessary. 6 / 7

Exchange lamps for another type. Cause 3: short-circuit protection has tripped. Disconnect dimmer from mains by switching off circuit breaker. Eliminate short-circuit. Switch circuit breakers and dimmer on again. Short-circuit protection is not based on a conventional fuse, no metallic separation of the operational current. Cause 4: load failure. Check load, replace light bulb. For inductive transformers, check primary fuse. LED lamp flashes repeatedly or is dimly lit when dimmer is switched off Cause: LED lamp is not suitable for this dimmer. Use a compensation module, see accessories. Use another type of LED lamp or an LED lamp of another manufacturer. 8 Accessories Compensation module LED Order no. 2375 00 9 Warranty The warranty is provided in accordance with statutory requirements via the specialist trade. Please submit or send faulty devices postage paid together with an error description to your responsible salesperson (specialist trade/installation company/electrical specialist trade). They will forward the devices to the Gira Service Center. Gira Giersiepen GmbH & Co. KG Elektro-Installations- Systeme Industriegebiet Mermbach Dahlienstraße 42477 Radevormwald Postfach 12 20 42461 Radevormwald Deutschland Tel +49(0)21 95-602-0 Fax +49(0)21 95-602-191 www.gira.de info@gira.de 7 / 7