Timers. GT3W Series Dual Time Range Timers. 250V AC/150V DC Time Range. 1: 0.1sec to 6 hours, 3: 0.1sec to 300 hours

Similar documents
RTE Series Analog Timers. UL Listed File No. E kPa to 110kPa (Operating), 70kPa to 110kPa (Transport)

Timers NEW DESIGN! RTE Series. RTE Series Analog Timers

DIN Rail Mounting Accessories. Style Appearance Use with Timers Part No. Appearance Part No. RTE-P2 SR3P Pin FingerSafe Socket RTE-P2 SR3P-05C

GT3F Series True OFF Delay Timers

Timers. RTE Series. RTE Series Analog Timers. Specifications. G-8 USA: (800) 262-IDEC or (408) , Canada (888) 317-IDEC

T imers Timers Selection Guide Timing Diagrams Overview RTE Series Analog Timers Instructions onlinecomponents.com IDEC.

Timers. GT5Y Series ON Delay Timers. ±3% maximum (over 10 to 50 C, reference temperature 20 C) Setting Error. ±10% maximum

Relays & Sockets RR Series Power Relays. Part Number Selection

Ultra Slim Relays 24

Intrinsically Safe Explosion Proof Barriers

Safety Control. FS1A Multi-function Safety Relay. Optional Parts. Connecting Tool. Marked Cable Tie. DIN Rail BNDN1000 Aluminum, 1m 35mm wide

Safety Control. FS1A Multi-function Safety Relay. Optional Parts. Marked Cable Tie. DIN Rail BNDN1000 Aluminum, 1m 35mm wide

PROGRAMMABLE MULTI-FUNCTION

Communication & Networking

PRODUCT SPECIFICATION. PC Board Relays. Series.

NON-PROGRAMMABLE ON DELAY, INTERVAL, TRUE OFF DELAY & FLASHER

NON-PROGRAMMABLE OFF DELAY, SINGLE SHOT

Solid-state Timer. Ordering Information. Specifications. Miniature Timer Compatible with the MY Relay. Accessories. Time Ranges

Multi Voltage Options. Multi Voltage Options 110VAC + 24VAC/DC 230VAC + 24VAC/DC 24VAC/DC 110VAC 230VAC

HITACHI. EH-150 series PLC EH-RTD8 Resistance Temperature Detective input module Instruction manual. Safety precautions

PROGRAMMABLE MULTI-RANGE REPEAT CYCLE & DELAYED INTERVAL

Conductive Level Controller

PC RELAY TERMINAL/ PC TERMINAL

H3CA-8H-AC/100/110/120

Power Supplies. PS5R Standard Series Switching Power Supplies. Part Numbers. Part Number

PS5R Series Switching Power Supplies. The PS5R offers a sleek, compact, ergonomic design, worldwide approvals, and broad range of output capacities.

Interlock Switches. Selection Guide. HS7A-DMC Magnetic Safety Switches

Communications & Networking

HR1S-AC Safety Relay Modules

Contact form. Operating Force. SPDT 25g Unsealed Solder / 187 Quick Connect. SPDT 50g Unsealed Solder / 187 Quick Connect

Slim Relay G2RV. Model Number Structure. Ordering Information. Model Number Legend. List of Models. Relay and Socket Combinations

AS-Interface Safety at Work

Solid-state Timer H3YN

H3CR-F H3CR-F8 H3CR-F-300 H3CR-F8-300

Sockets. SY Series: DIN Rail Snap-Mount. F-14 USA: (800) 262-IDEC or (408) , Canada (888) 317-IDEC. SY4S Sockets SY4S-05

RM84 miniature relays

Communications & Networking

Classification Enclosure rating Input voltage Type of

Contact form. Operating Force. SPDT 100g Unsealed Solder / 187 Quick Connect. SPDT 200g Unsealed Solder / 187 Quick Connect

PROGRAMMABLE CONTROLLER. FP0 A/D Converter Unit. Technical Manual ARCT1F321E

Transistor drive 2c/4c 5A slim power relays

Relays & Sockets. RQ Series. RQ Series PCB Relays Part Number Selection

Conforms to VDE0435/2021 C/250, VDE0110, VDE0106/P100 Conforms to EN , pren

Solid-state Timer. Ordering Information. Miniature Timer with Multiple Time Ranges and Multiple Operating Modes H3YN- - Accessories (Order Separately)

masterelectronics.com onlinecomponents.com

RF1V Force Guided Relays SF1V Relay Sockets

TIME DELAY RELAYS Product Summary

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-F...

Solid-state Timer. Ordering Information. Ultra-slim Timer for G2R Relay Socket. H3RN-jj. Accessories (Order Separately) Connecting Socket

Solid-State Counter/Timer

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-F...

HIGH PERFORMANCE MINIATURE SWITCHES WITH WIDE RANGE

RUC industrial relays of small dimensions

Basic Switch. Pin plunger Short hinge Hinge lever Long hinge lever Simulated hinge Short hinge Hinge roller lever lever roller lever lever

SAFETY RELAY YRB-4EML-31S MAIN FEATURES

Special-purpose Basic Switch

V-3000 Series Miniature Basic Switches

Making Hazardous Operations Safe and Productive

Page Housing Plastic Metal Mounting DIN Rail or surface mount Panel or bracket mount Wattage Range 10W to 240W 7.5W to 240W 10W to 300W

MODEL: M5DY SEN TRONIC AG CURRENT LOOP SUPPLY. [2] POWER INPUT AC Power M: V AC (Operational voltage range V, Hz)

Model Number Structure

Time-limit operation/ self-resetting DPDT --- H3M H3M with Y92F-40 adapter SPDT SPDT H3M-H H3M-H with Y92F-40 adapter

Ordering Information. I/O Relay G7T. Model Number Legend Slim-styled I/O Relay Saves Space in Panel

Solid-state Timer H3FA. Model Number Structure. DIP Model Timer for PC Board Use Provides Contact and Solid-state Output

Ordering Information. I/O Relay G7T. Model Number Legend Slim-styled I/O Relay Saves Space in Panel

Micro Contactor MA Series

Time-limit contact Time ranges Supply voltage Mounting s to 3 h 24, 100 to 120, 200 to 230 VAC (50/60 Hz); 12, 24, 48, 125, 100 to 110 VDC

D2D. Door Interlock Switch. Ordering Information. Power Switch with Minimum Contact Gap of 3 mm. Model Number Legend.

RUC industrial relays of small dimensions

Safety Control. Safety.

Safety Control. Safety. Selection Guide Safety Relay HR1S-AC Safety Relay HR1S-AF

Digital Timer. Ordering Information. 1/16 DIN, Quartz Timer with Four-Digit LED Display

DPST-NO None 2 channels Auto-reset Inverse (+/-) 24 VAC/VDC 4 G9SB-2002-A 1 channel or 2

RT-1 PC RELAY TERMINAL RT-1 PC TERMINAL

RUC-M industrial relays for DC loads

Thermal-Magnetic Circuit Breaker 2216-S

Industrial Control Relays Relays and terminal module RS type

Safety Relay Unit (I/O Unit Type)

Magnetic and Hydraulic-Magnetic Circuit Breaker

Switches & Pilot Devices

Barriers. EB3N Discrete Input Barrier with Redundant Output

DC I/O Conversion Module

TIMERS FOR ALL APPLICATIONS

Long-time range model (0.1 min to 10 h) 24 VAC; SPDT H3RN-1 H3RN-11 12, 24 VDC DPST-NO H3RN-2 H3RN-21

Sensing method Appearance Connection method Sensing distance Output Model. M12 connector 10±3 mm. Size Type Appearance Cable length Model Straight

H Series PLC. ! : Indicates Compulsion. EH-150 Analog input module EH-AXH8M Instruction manual. Safety precautions DANGER CAUTION COMPULSION

16 g SS-01GL-FD SS-01GL-F SS-01GL-FT 50 g SS-01GLD SS-01GLD1 SS-01GLD2 SS-01GL SS-01GLT Simulated roller lever

SS Series Compatible Mounting with a Simple Construction and Easy-to-Use Design Concept

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-T...

Solid-state Timer. Mounting system contact t contact. t Surface mounting/ track mounting

TIME DELAY RELAYS Product Summary

D2D. Door Interlock Switch. Ordering Information. Power Switch with Minimum Contact Gap of 3 mm. Model Number Legend.

Main contacts Auxiliary contact Number of input channels Rated voltage Model Category 24 VAC/VDC 3PST-NO SPST-NC 1 channel or 2 channels possible

CompactLogix Power Supplies Specifications

TIMERS FOR ALL APPLICATIONS

Terminals Solder terminals Quick-connect. PCB terminals terminals (#110) 3 A Pin plunger SS-3GP SS-3GPT SS-3GPD SS-3GPB

Thread length (overall length) material

Timer, Counter & Display

Part No. Z , IA Jul OPERATION MANUAL. High Voltage Digitalmeter A

Model Number Structure

Transcription:

GT3W Key features: Sequential start, sequential interval, on-delay, recycler, and interval ON timing functions 2 time settings in one timer 8 selectable operation modes on each model Mountable in sockets or flush panel Power and output status indicating LEDs Time ranges up to 300 hours UL, c-ul Listed File No. E55996 GT3W Series Dual General Specifications Contact Ratings Operation System Solid state CMOS Circuit Allowable Contact Power 960VA/120W Operation Type Multi-Mode Allowable Voltage 250V AC/150V DC 1: 0.1sec to 6 hours, 3: 0.1sec to 300 hours Allowable Current 5A Pollution Degree 2 (IE60664-1) Maximum permissible Over Voltage Category III (IE60664-1) operating frequency 1800 cycles per hour AF20 100-240V AC(50/60Hz) 1/8HP, 240V AC Rated Operational Voltage AD24 24V AC(50/60Hz)/24V DC Rated Load 3A, 240V AC (Resistive) D12 12V DC 5A, 120V AC/30V DC (Resistive) AF20 85-264V AC(50/60Hz) Conditional Short Circuit Fuse 5A, 250V Voltage Tolerance AD24 20.4-26.4V AC(50/60Hz)/21.6-26.4V DC 100,000 op. minimum D12 10.8-13.2V DC Electrical Life (Resistive) Disengaging Value of Input Voltage Rated Voltage x10% minimum Mechanical 20,000,000 op. minimum Range of Ambient Operating Temperature -10 to +50ºC (without freezing) Range of Ambient Storage and Transport Temperature -30 to +75ºC (without freezing) Range of Relative Humidity 35 to 85%RH (without condensation) Atmospheric Pressure 80kPa to 110kPa (Operating), 70kPa to 110kPa (Transport) Reset Time 60msec maximum Repeat Error ±0.2%, ±10msec* Voltage Error ±0.2%, ±10msec* Temperature Error ±0.6%, ±10msec* Setting Error ±10% maximum Insulation Resistance 100MΩ minimum (500V DC) Dielectric Strength Between power and output terminals: 2000V AC, 1 minute Between contacts of different poles: 2000V AC, 1 minute Between contacts of the same pole:750v AC, 1 minute Vibration Resistance 10 to 55Hz amplitude 0.75mm 2 hours in each of 3 axes Shock Resistance Operating extremes: 98m/sec 2 (approx.10g) Damage limits: 490m/sec 2 (approx. 50G) 3 times in each of 3 axes Degree of Protection IP40 (enclosure), IP20 (socket) (IEC60529) 100V AC/60Hz 2.3VA Power Consumption AF20 200V AC/60Hz 4.6VA (Approx.) AD24 (AC/DC) 1.8VA/0.9W Mounting Position Free Dimensions 40Hx 36W x 70 mm Weight (Approx.) 72g * For the value of the error against a preset time, whichever the largest applies. 856 www.idec.com

GT3W Part Numbers Part Number List Mode of Operation Output Contact * Rated Voltage Pin Configuration New Part Numbers A: Sequential Start B: On-delay with course and fine C: Recycler and instaneous D: Recycler outputs (OFF Start) E: Recycler outputs (ON Start) F: Interval ON G: Interval ON Delay H: Sequential Interval 3A, 240V AC 5A, 120V AC/30V DC (Resistive Load) Delayed SPDT + Delayed SPDT 1. For timing diagrams and schematics, see page 858. 2. For socket and accessory part number information, see page 860. 3. 8- and 11-pin models differ only in the number of pins (extra pins are not used). 4. For the timing diagram overview, see page 832. 5. *For details on setting time ranges, see the instructions on page 859. 1: 0.1sec - 6 hours *(See Settings for details.) 3: 0.1sec - 300 hours 100 to 240V AC (50/60Hz) 12V DC 100 to 240V AC (50/60Hz) Table Code: 1 Code: 3 Scale Selector Selector Scale 1S 0.1 sec - 1 sec 1S 0.1 sec - 3 sec 10S 0-1 0.3 sec - 10 sec 1M 0-3 3 sec - 3 min 10M 15 sec - 10 min 1H 3 min - 3 hours 1S 0.1 sec - 6 sec 1S 0.6 sec - 30 sec 10S 1 sec - 60 sec 1M 36 sec - 30 min 1M 0-6 6 sec - 6 min 1H 0-30 36min - 30 hours 10M 1 min - 60 min 1H 6 min - 6 hours 10H 6 hours - 300 hours 8 pin GT3W-A11AF20N 11 pin GT3W-A11EAF20N 8 pin GT3W-A11AD24N 11 pin GT3W-A11EAD24N 8 pin GT3W-A11D12N 11 pin GT3W-A11ED12N 8 pin GT3W-A33AF20N GT3W-A33AD24N 800-262-IDEC (4332) USA & Canada 857

GT3W T2 Selector Operation Mode Selector T1 Selector Special expertise is required to use Electronic. Instructions: Setting GT3W Timer T2 Setting Knob T1 Setting Knob All Electronic Timer modules are manufactured under IDEC s rigorous quality control system, but users must add a backup or fail safe provision to the control system when using the Electronic Timer in applications where heavy damage or personal injury may occur should the Electronic Timer fail. Install the Electronic Timer according to instructions described in this catalog. Make sure that the operating conditions are as described in the specifications. If you are uncertain about the specifications, contact IDEC in advance. In these directions, safety precautions are categorized in order of importance to Warning and Caution. Warning Warning notices are used to emphasize that improper operation may cause sever personal injury or death. Turn power off to the Electronic timer before starting installation, removal, Wiring, maintenance, and inspection on the Electronic Timer. Failure to turn power off may cause electrical shocks or fire hazard. Emergency stop and interlocking circuits must be configured outside the Electronic timer. If such a circuit is configured inside the Electronic Timer, failure of the Electronic timer may cause malfunction of the control system, or an accident. Safety Precautions Caution 1. The switches should be securely turned using a flat screwdriver 4mm wide (maximum). Note that incorrect setting may cause malfunction. The switches, which do not turn infinitely, should not be turned beyond their limits. 2. Since changing the setting during timer operation my cause malfunction, turn power off before changing. Caution notices are used where inattention might cause personal injury or damage to equipment. The Electronic Timer is designed for installation in equipment. Do not install the Electronic Timer outside equipment. Install the Electronic Timer in environments described in the specifications. If the Electronic Timer is used in places where it will be subjected to high-temperature, high-humidity, condensation, corrosive gases, excessive vibrations, or excessive shocks, then electrical shocks, fire hazard, or malfunction could result. Use an IEC60127-approved fuse and circuit breaker on the power and output line outside the Electronic Timer. Do not disassemble, repair, or modify the Electronic Timer. When disposing of the Electronic Timer, do so as industrial waste. 800-262-IDEC (4332) USA & Canada 859

GT3 Series Accessories GT3 Series Accessories DIN Rail Mounting Accessories DIN Rail/Surface Mount Sockets and Hold-Down Springs DIN Rail Mount Socket Applicable Hold-Down Springs Style Appearance Use with Part No. Appearance Part No. 8-Pin Screw Terminal (dual tier) GT3A-1, 2, 3 (8-pin) GT3F-1, 2 (8-pin) GT3W (8-pin) SR2P-05 11-Pin Screw Terminal (dual tier) 8-Pin Fingersafe Socket GT3A-1, 2, 3 (11-pin) GT3A-4, 5, 6 GT3F-1, 2 (11-pin) GT3W (11-pin) GT3A-1, 2, 3 (8-pin) GT3F-1, 2 (8-pin) GT3W (8-pin) SR3P-05 SR2P-05C SFA-203 11-Pin Fingersafe Socket GT3A-1, 2, 3 (11-pin) GT3A-4, 5, 6 GT3F-1, 2 (11-pin) GT3W (11-pin) SR3P-05C 8-Pin Screw Terminal GT3A-1, 2, 3 (8-pin) GT3F-1, 2 (8-pin) GT3W (8-pin) SR2P-06 SFA-202 11-Pin Screw Terminal GT3A-1, 2, 3 (11-pin) GT3A-4, 5, 6 GT3F-1, 2 (11-pin) GT3W (11-pin) SR3P-06 DIN Mounting Rail Length 1000mm BNDN1000 Installation of Hold-Down Springs DIN Rail Mount Socket Insert the springs into the outer slots with the projections facing inside. Insert the springs into the slots. Panel Mount Socket Hold-down Spring SFA-402 Insert Socket SR2P-06 Hold-down Spring (sold separately) SFA-202 (use two springs) Socket SR2P-05 Hold-down Spring (sold separately) SFA-203 (use two springs) 8-pin Socket SR2P-51 860 www.idec.com

GT3 Series Accessories Panel Mount Sockets and Hold-Down Springs Panel Mount Socket Panel Mounting Accessories Applicable HD Springs Style Appearance Use with Part No. Appearance Part No. 8-Pin Solder Terminal 11-Pin Solder Terminal For information on installing the hold-down springs, see page 860. GT3A- (8-pin) GT3W- (8-pin) GT3F- (8-pin) GT3A- (11-pin) GT3W- (11-pin) GT3F- (11-pin) Flush Panel Mount Adapter and Sockets that use an Adapter Accessory Description Appearance Use with Part No. Panel Mount Adapter Adaptor for flush panel mounting GT3 timers All GT3 timers RTB-G01 Sockets for use with Panel Mount Adapter 8-pin screw terminal SR2P-51 SR3P-51 All 8-pin timers SFA-402 SR6P-M08G 11-pin screw terminal (Shown: SR6P-M08G for Wiring Socket Adapter) All 11-pin timers SR6P-M11G 8-pin solder terminal All 8-pin timers SR6P-S08 11-pin solder terminal All 11-pin timers SR6P-S11 No hold down springs are available for flush panel mounting. 800-262-IDEC (4332) USA & Canada 861

GT3 Series Dimensions 36.0 Dimensions 5.6 70.0 Unit: mm N40.0 NOTE: GT3W series are UL Listed when used in combination with following IDEC s sockets: GT3W-A11, A33: SR2P-06* pin type socket. GT3W-A11E: SR3P-05* pin type socket. (*-May be followed by A,B,C or U) The socket to be used with these timers are rated: -Conductor Temperature Rating 60ºC min. -Use 14AWG max.(2mm 2 max.) Copper conductors only -Terminal Torque 1.0 to 1.3 N-m Analog GT3 Timer, 8-Pin with SR2P-06 Analog GT3 Timer, 11-Pin with SR3P-06 Analog Setting Type (When using DIN Rail) When using BAA/BAP: 99 maximum 95 maximum 1.7 31.7 Analog Setting Type (When using DIN Rail) When using BAA/BAP: 99 maximum 95 maximum 1.7 40 60 40 31.7 60 36 8 64.2 13 Holddown spring (SFA-202) 18 22 DIN Rail 1 36 8 64.2 13 Holddown spring (SFA-202) 18 22 DIN Rail 1 Analog GT3 Timer, 11-Pin with SR3P-05 Analog Setting Type (When using DIN Rail) BAA or BAP: 105.5 maximum 101.5 maximum DIN Rail (BAA/BAP/BADA) 40 33 ø27 52 36 8 64.2 13 Hold-down Spring (SFA-203) 16.5 20 28.5 3 Panel Mount Adapter Analog GT3 Timer, 8-Pin and 11-Pin with SR6P-S08 or SR6P-S11 48 98 maximum Panel Thickness 0.8 to 5mm 1.7 42.5 48 11 61.2 Back Wiring Socket 864 www.idec.com

GE1A Key features: DPDT or SPDT + instantaneous SPDT 8-pin, octal base Repeat error ±0.2% maximum Large, clear knob for easy setting Instant monitoring of operational status by LED indicators UL, c-ul Listed File No. E55996 GE1A Series ON Delay Single Function Specifications Rated Operating Voltage 100 to 120V AC 220 to 240V AC Voltage Tolerance AC: 85 to 110% DC: 90 to 110% Contact Rating 240V AC/5A 24V DC/5A Contact Form DPDT or SPDT+ instantaneous SPDT Repeat Error ±0.2% ±10msec maximum Voltage Error ±0.5% ±10msec maximum Temperature Error ±3% maximum Setting Error ±10% maximum Reset Time 0.1 sec maximum Insulation Resistance 100MΩ minimum (500V DC megger) Dielectric Strength Between power and output terminals: 1,500V AC, 1 minute Between contact circuits: 750V AC, 1 minute Vibration Resistance Damage limits: Amplitude 0.75mm, 10 to 55 Hz Operating extremes: Amplitude 0.5mm, 10 to 55 Hz Shock Resistance Damage limits: 500m/s 2 (Approx. 50G) 24V AC type: 1.6 VA 24V DC type: 1.0W GE1A-B 110V AC type: 3.8 VA Power Consumption GE1A-C Electrical Life Mechanical Life Operating Temperature Operating Humidity 220V AC type: 7.7 VA 24V AC type: 2.0 VA 24V DC type: 0.8W 110V AC type: 3.5 VA 220V AC type: 8.0 VA 100,000 operations minimum (at full rated load) 10,000,000 operations minimum 10 to +55 C (without freezing) 35 to 85% RH (without freezing) 866 www.idec.com

GE1A Part Numbering List Mode of Operation Contact Output Rated Voltage Complete Part Number ON-Delay Delayed SPDT + Instantaneous SPDT Delayed DPDT 24V DC/120V AC, 5A 240V AC, 5A GE1A-B Delayed SPDT + Instantaneous SPDT Operation Mode Selection (-) k p (+) ON-Delay 1 MODE A m n l o j q POWER Item Terminal Number Operation Set Time Power Delayed Contact Instantaneous Contact Indicator 2-7 (8p) 5-8 (8p) (NC) 6-8 (8p) (NO) POWER 1-4 (NC) 1-3 (NO) Note: Terminals 1, 3, and 4 are for the instantaneous contact OUT 220-240V AC GE1A-B10HA220 110-120V AC 0.1s - 10h GE1A-B10HA110 220-240V AC GE1A-B10HAD24 GE1A-B30HA220 110-120V AC 0.3s - 30h GE1A-B30HA110 220-240V AC GE1A-B30HAD24 GE1A-C10HA220 110-120V AC 0.1s - 10h GE1A-C10HA110 220-240V AC GE1A-C10HAD24 GE1A-C30HA220 110-120V AC 0.3s - 30h GE1A-C30HA110 Timing Diagrams/Schematics (-) GE1A-C Delayed DPDT m n l o k p j q POWER (+) Item Terminal Number Operation Set Time Power 2-7 (8p) Delayed Contact Indicator 5-8 (8p) (NC) 6-8 (8p) (NO) POWER OUT GE1A-C30HAD24 800-262-IDEC (4332) USA & Canada 867

GE1A Accessories Mounting Accessories & Sockets Item Appearance Part No. 8-Pin Screw Terminal (dual tier) SR2P-05 8-Pin Fingersafe Socket SR2P-05C DIN Rail/Surface Mounting Accessories 8-Pin Screw Terminal SR2P-06 DIN Mounting Rail Length 1000mm BNDN1000 8-Pin Solder Terminal SR2P-51 Panel Mounting Accessories Screw Terminal Socket SR6P-M08G Panel Mount Adapter GE9Z-AD Other Accessories Item Appearance Part No. Dust Cover GE9Z-C48 868 www.idec.com