the data line series 12-00131 OUTDOOR SINGLE PORT POE RJ45 SURGE ARRESTOR rev0-10/100/1000 Base-T CAT5e Protection - IEEE 802.3 A/F Power Mode B - Solid-state silicon-avalanche diodes with internal TVS - Operates at low voltage, clamping voltage and capacitance. - High speed data line with ESD protection The outdoor single port Power-over Ethernet (PoE) surge arrestor is engineered to protect sensitive data-processing equipment connected to a PoE (Power over Ethernet) network from transient over-voltages. The unit is designed for PoE or non -PoE devices with connection speeds of up to 1 Gbps. Network/line Surge Protection Max. Discharge Current (Fine L-L) 40A (8/20us) Max. Discharge Current (Coarse L-E) 2.5kA (8/20us) Residual Voltage - Lines <5V (1.2/50us) Residual Voltage - POE Lines <60V(1.2/50us) Technology Supported Gigabit Cat5e Speed Supported >1000 MBit/s Pairs Protected 1-2, 3-6, 4-5, 7-8 Other Indication N/A Temperature Range -20 C to +70 C Degree of Protection IP54 IEEE 802.3ab/af Lead Length N/A 91x79x45mm 0.110kg 79mm Pinout Configuration Pin Alternative B 1 2 3 4 /Vport Positive 5 /Vport Positive 6 7 /Vport Negative 8 /Vport Negative 91mm 45mm
THE DUOLINE SERIES 12-00220 Computer Protection Systems - Plug-and-Play concept - High surge capability - Fire hazard protection - Protection indication lamps - Line filtration Clearline s 12-00220 protects your Computer, printer, scanner and modem against lightning and surges without additional earthing. The protection modules have multiple stages of protection capable of blocking severe lightning and power surges. Clearline incorporates a fast overload device which will be activated in extreme conditions. Functional indication lamps display the protection status of the unit. Clearline s unique built-in thermal protection devices eliminates fire hazards. Power Module Max. continuous voltage Max. continuous current (Thermal overload protected) Max. discharge current at 8/20 Response Time Leakage current Filtration 250V 50Hz 16A 8kA L-N, L-E, N-E <25ns <1.0mA 20dB Modem Module Max discharge current 20kA (8/20) Residual voltage at 10kA (Common mode) Residual voltage at 10kA (Differential mode) speed Approx. 200V Approx. 200V 10 Mbits/s RJ11 Cable included Designed and Manufactured by: Clearline Protection Systems (Pty) Ltd Roan Crescent Corporate Park North, Old Pta Road, Midrand, South Africa P.O. Box 5985, Halfway House, 1685 Tel: +27 (0) 11 848-1100 Fax: +27 (0) 11 314-3880 E-mail: sales@clearline.co.za www.clearline.co.za the electronic protection company
The dataline series 12-00378 Gigabit Fast Ethernet 24 Port Protector Power Over Ethernet - POE rev1 - All 8 lines protected - Each pair supports 250Mbits/s - Negligible insertion loss Protects fast gigabit ethernet LAN equipment such as hubs switches, network interface cards and IP POE cameras from induced lightning and electrostatic discharge. Compatible to 100Base-T and 1000Base-T Network/line Surge Protection Max. Discharge Current (Fine L-L) 40A (8/20us) Max. Discharge Current (Coarse L-E) 2.5kA (8/20us) Residual Voltage - Lines <5V (1.2/50us) Residual Voltage - POE Lines <60V(1.2/50us) Technology Supported Gigabit Cat5e Speed Supported >1000 MBit/s Pairs Protected 1-2, 3-6, 4-5, 7-8 Other Indication N/A Temperature Range -20 C to +70 C IEEE 802.3ab/af Lead Length 24x 300mm RJ45-RJ45 Cable 483x74x45mm 1.380kg Pinout Configuration Pin Alternative B 1 2 3 4 /Vport Positive 5 /Vport Positive 6 7 /Vport Negative 8 /Vport Negative
the powerline series 12-00760 Surge Plug rev2 - High surge handling capability - Economical secondary protection - Thermal and overcurrent fusing - Visual fault indication - Differential and common mode protection Surge plugs are used for the secondary protection of computers, video equipment, TV, alarms and other electronic equipment. They are available in the normal 16A round pin. These plugs are fitted with an overcurrent and thermal fuse. In the rare event of varistor failure, the varistors are disconnected from the mains supply, preventing any dangerous temperature rise. The fault indication LED which is normally lit will go OFF to indicate the faulty protection has been disconnected. Mains power will still be available to the unprotected equipment. Power Surge Protection Nom. Input Voltage Max. Continuous Current Max. Discharge Current Residual Voltage Response Time Input Connectors Output Connectors Other Indication Temperature Range Lead Length 230VAC 50Hz 16A 8kA L-N, L-E, N-E (8/20us) <900V <25ns 16A 3Pin Plug Screw Terminal LED -10 C to +70 C IEC 61643-1 N/A 47.5x46x43.8mm 0.07kg 47.5 43.8 46
the powerline series 12-00815 rev1 Surge Plug - High surge handling capability - Economical secondary protection - Thermal and overcurrent fusing - Visual fault indication - Differential and common mode protection Surge plugs are used for the secondary protection of computers, video equipment, TV, alarms and other electronic equipment. They are available in the dedicated 16A round pin. These plugs are fitted with an overcurrent and thermal fuse. In the rare event of varistor failure, the varistors are disconnected from the mains supply, preventing any dangerous temperature rise. The fault indication LED which is normally lit will go OFF to indicate the faulty protection has been disconnected. Mains power will still be available to the unprotected equipment. Power Surge Protection Nom. Input Voltage Max. Continuous Current Max. Discharge Current Residual Voltage Response Time Input Connectors Output Connectors Other Indication Temperature Range Lead Length 230VAC 50Hz 16A 8kA L-N, L-E, N-E (8/20us) <900V <25ns 16A 3Pin Dedicated Plug Screw Terminal LED -10 C to +70 C IEC 61643-1 N/A 47.5x46x43.8mm 0.07kg 47.5 43.8 46
data line series 12-00857 RF Line Antenna Protection rev0 - Low insertion loss - Compact design The surge protector provides an effective means of protecting equipment from surge voltage damage. The device is designed to protect the Coax connected equipment such as a satellite LNA or LNB from sudden surges or lightning strikes. This offers additional protection to already grounded equipment and additional earthing is provided. Antenna/Satellite Surge Protection Nom. Impulse Discharge Current Residual voltage (Ismax) DC Power Pass Response time Frequency Range Impedance F Connector Type Insertion Loss (5-1000MHz) Insertion Loss (1001-2000MHz) Insertion Loss (2001-2500MHz) Return Loss (5-1000MHz) Return Loss (1001-2000MHz) Return Loss (2001-2500MHz) 5kA (@8/20uS) <100V L-L 28V, 1A <100ns 5-2400MHz 75Ω Male to Female (3/8inch) 0.2dB (typ) / 0.5 db (max) 0.3dB (typ) / 0.7 db (max) 0.5dB (typ) / 1.0 db (max) 18dB (typ) / 16dB (min) 16dB (typ) / 14dB (min) 14dB (typ) / 12dB (min) 13 (Φ) 42(L)mm 18g Dimension 42mm 13mm 13mm
THE DUOLINE SERIES HD CCTV Signal and PSU Protector - Easy installation - Low insertion loss - Failsafe protection - Combined CCTV + Power - Supply protection Coaxial protection for High Definition data transmission lines. Suitable for HD CCTV applications. They protect both the HD CCTV signal as well as the DC power supply voltage. These devices exhibit negligible insertion loss and are fitted in line at the equipment connection. 12-00957 rev 0 Order Code Max operating voltage Max operating current Max discharge current (Differential mode) Max discharge current (Common mode) Residual voltage Insertion loss at 10MHz Connectors Impedance Range Temperature range Application Power Supply Max PSU voltage Max PSU current Max clamping voltage (differential mode) Max surge current rating (differential mode) Connectors Application 12-00957 1V p-p 0.3A 2kA 2kA < 2.5V 0.8dB BNC M-F 75ohm unbalanced Up to 100m - 10 C to 70 C HD CCTV Composite 15VDC 1.0A <20V 71A (8/20us) DC Jack 2.1mm Camera protection plus power supply Designed and Manufactured by: Clearline Protection Systems (Pty) Ltd Roan Crescent Corporate Park North, Old Pta Road, Midrand, South Africa P.O. Box 5985, Halfway House, 1685 Tel: +27 (0) 11 848-1111 Fax: +27 (0) 11 314-3880 E-mail: info@clearline.co.za www.clearline.co.za the electronic protection company
THE DATALINE SERIES HD Coaxial Network/CCTV Protection - Easy installation - Low insertion loss - Failsafe protection - Compact design 12-00961 / 12-00971 rev 0 Coaxial protection for High Definition data transmission lines. Suitable for HD CCTV applications. These devices exhibit negligible insertion loss and are fitted in line at the equipment connection. Order Code Max operating voltage Max operating current Max discharge current (Differential mode) Max discharge current (Common mode) Residual voltage Insertion loss at 10MHz Connectors Impedance Range Temperature range Application 12-00961 1V p-p 0.3A 2kA 2kA < 2.5V 0.8dB BNC M-F 75ohm unbalanced Up to 100m - 10 C to 70 C HD CCTV Composite 12-00971 1V p-p 0.3A 2kA 2kA < 2.5V 0.8dB BNC F-F 75ohm unbalanced Up to 100m - 10 C to 70 C HD CCTV Composite Designed and Manufactured by: Clearline Protection Systems (Pty) Ltd Roan Crescent Corporate Park North, Old Pta Road, Midrand, South Africa P.O. Box 5985, Halfway House, 1685 Tel: +27 (0) 11 848-1111 Fax: +27 (0) 11 314-3880 E-mail: info@clearline.co.za www.clearline.co.za the electronic protection company
THE DATALINE SERIES Gigabit Fast Ethernet inline Protector 12-00967 rev 0 - All 8 lines protected - Each pair supports 250Mbits/s - Negligible insertion loss Protects fast gigabit ethernet LAN equipment such as hubs, switches and network interface cards from induced lightning and electrostatic discharge. The device is designed for indoor or outdoor use inside a weatherproof enclosure. Compatible to 100Base-T and 1000Base-T Specification Network Clamping Voltage - Lines Maximum discharge current - coarse protection Maximum discharge current - fine protection Pairs protected Standards compliance Test frequencies in MHz NEXT (Limits as per IEC 802.3) Return Loss (Limits as per IEC 802.3) Attenuation (Limits as per IEC 802.3) rate Bandwith (3dB) per pair <5V 2kA (8/20) 40A (8/20) 1-2, 3-6, 4-5, 7-8 IEEE 802.3u 100 250 <39.9 <33.1 <10.2 <8.0 <20.8 <33.8 IEEE 802.3ab/af 1000Mbits/s (250Mbits/s per pair) >350MHz 25 77 28 Not to scale
The dataline series 12-00974 Gigabit Fast Ethernet in-line Protector Power Over Ethernet - POE rev2 - All 8 lines protected - Each pair supports 250Mbits/s - Negligible insertion loss Protects fast gigabit ethernet LAN equipment such as hubs switches, network interface cards and IP POE cameras from induced lightning and electrostatic discharge. The device is designed for indoor or outdoor use, inside a weatherproof enclosure. Compatible to 100Base-T and 1000Base-T Network/line Surge Protection Max. Discharge Current (Fine L-L) 40A (8/20us) Max. Discharge Current (Coarse L-E) 2.5kA (8/20us) Residual Voltage - Lines <5V (1.2/50us) Residual Voltage - POE Lines <60V(1.2/50us) Technology Supported Gigabit Cat5e Speed Supported >1000 MBit/s Pairs Protected 1-2, 3-6, 4-5, 7-8 Other Indication N/A Temperature Range -20 C to +70 C IEEE 802.3ab/af Lead Length 1x 300mm RJ45-RJ45 Cable 77x25x28mm 0.045kg Pinout Configuration Pin Alternative B 1 2 3 4 /Vport Positive 5 /Vport Positive 6 7 /Vport Negative 8 /Vport Negative 25 77 28 Not to scale
THE dataline SERIES 12-00991 HDMI PROTECTOR 12-00991 rev2 - Plug-and-Play concept - High surge capability - HDMI output cable max.distance supported is 10 meters with 12bit - Low TMDS signal loss - HDCP compliant - Solid-state silicon-avalanche technology - HDMI 1.4 with 3D and HDMI Ethernet Channel (HEC) support The Inline HDMI surge protector offers protection to HDMI devices such as HDTV, PlayStation, HDPVR etc. against Cable Discharge, Eletrostatic Discharge and Lightning/Surge. The unit simply gets plugged into the HDMI socket of the equipment being protected and the HDMI cable plugs directly into the unit. Its use is to protect expensive HDMI installations as well as keep your equipment operational during bad weather. This is an excellent device to protect against static shocks, surges, and lightning strikes. The device has many circuits and components to protect every HDMI cable from surge. Input Output Supported Devices Relative Humidity HDMI male port HDMI female port Working Temp 0 C 40 C Dimension All the devices with HDMI output 5% 90% 39 X 26 X 12mm 25g IEC 61000-4-2 (ESD) 15kV (air), 8kV (contact) for surge protection IEC 61000-4-4 (EFT) 40A (5/50ns) for surge protection IEC 61000-4-5 (Lightning) 5A (8/20 us) for surge protection. Clearline Protection Systems (Pty) Ltd Roan Crescent Corporate Park North, Old Pta Road, Midrand, South Africa P.O. Box 5985, Halfway House, 1685 Tel: +27 (0) 11 848-1100 Fax: +27 (0) 11 314-3880 E-mail: sales@clearline.co.za www.clearline.co.za
the powerline series 12-00851 Electric fence Protection Kit rev0 - Built in surge suppression - High surge capability - Compact design - Effective filtration - Fire hazard protection - Power indication Electric Fence Protection Kit This protection kit provides and integrated approach to the protection of electric fences. It provides surge and filtered protection for the incoming mains supply with an additional protector for earth potential equalization. A high voltage unit is supplied for the energizer output terminals. Power Surge Protection High Voltage Surge Protection Nom. Input Voltage 230VAC 50Hz Max. High Voltage Output 15kVDC Max. Continuous Current 10A Max. High Voltage Surge Current 6500A (8/20us) Max. Discharge Current 8kA L-N, L-E, N-E (8/20us) Response Time <25ns Residual Voltage <900V Response Time <25ns Input Connectors 16A 3Pin Plug Output Connectors 16A 3Pin Socket Filtration Filtration Performance Earth Leakage Current See graph on page2 <1.5mA 190 70 Other Indication Temperature Range Lead Length LED -20 C to +70 C IEC 164-1, 61643-1 1.5 meters 190x140x70mm 1.105kg 140 Filter characteristics 100 80 db Attenuation 60 40 2 1 10M Hz 20 10K 100K 1M 1 Common mode 2 Differential mode Frequency Turn page for more information
Installation 1. Connect the two outer sockets (red) to the L1(Fence Live Out) and L2 (Fence Live Return) respectively to the energizer and to the fence as per drawing. 2. Connect the inner socket (black) to the Earth of the energizer and to the Fence Earth as per drawing. 3. Plug the mains cable from the Electric Fence Protection Kit to a 3pin 16Amp wall socket. 4. Plug the Energizer ( outgoing mains) to the 3pin 16Amp socket on the Electric Fence Protection Kit as shown on drawing. Warranty All Clearline protection products carry a warranty for a period of two years from the date of purchase, provided that they are installed in accordance with the manufacturer s recommendations. Defective devices should be returned prepaid to Clearline Head Office or to the registered agent in the various areas. The Manufacturer s liability is limited to the repair or replacement of the product (at the manufacturer s discretion) which in it s judgement has not been misused ro operated under conditions exceeding the manufacturer s specifications. The warranty is void if the devices in question have been opened or serviced by anyone other than authorised Clearline personnel. Clearline will not be held responsible for consequential or implied damages.