ALESIS M20. System Exclusive

Similar documents
ALESIS M20. RS-422 Implementation

328 XD TASCAM DTRS STEREO INPUTS. 0dBFS = 18dBu. MIX dbfs RIGHT SELECT MUTE AES/EBU SOLO EXIT FUNCTION S/PDIF PARAMETER CLOCK CLOCK IN OUT IN MIDI OUT

DMPro Midi Sysex Specification v /25/99

D-90 & D & 16 Track Digital Multitrack

Cab Bus Communications Protocol

MachineControl Guide. Version 2.0 for Pro Tools TDM on Windows and Macintosh. Digidesign

Communications Protocol

MDS-E12/E11/E52 RS-232C Interface Manual -ADDITIONAL INFORMATION-

DIGITAL PIANO Date: Oct. 5, 2000 Model HP 147R MIDI Implementation Version: 1.00

v1.5 MIDI Implementation guide

PFC96Evo / PFC144Evo CONTROLLER MODBUS PROTOCOL

Tongta Inverter TDS-F8

1 Starting to use the RC-828

Digital Projector X30N/X35N

AdrenaLinn III MIDI Implementation Version Software

CB ELECTRONICS. P2MMC RS422-Midi Machine Control Interface

HVR-1500 HVR-1500A. PROTOCOL MANUAL 1st Edition (Revised 8) DIGITAL VIDEOCASSETTE PLAYER DSR-60/60P DSR-1600/1600P DSR-1600A/1600AP

JPEG2000 HDTV RECORDER

User Guide. English. Manual Version 1.1

3.42 MANUAL ADDENDUM

RADAR. Written by Robin LeBoe and Will Meadows

IS-Dev Kit-5 and IS-Dev Kit-6 Users Manual

Contents. Additional Instructions P-3X CANopen

It is the installer's responsibility to follow all instructions in this manual and to follow correct electrical practice.

MIDI Control for RedNet 4 and RedNet MP8R

Automatic transfer switch

Event Electronics EZbus Midi Implementation

FRONT PANEL OVERVIEW...1 REAR PANEL OVERVIEW...3 HOOKUP DIAGRAM...4 DISPLAYING INFORMATION...6

RADAR Operator s Manual. Software Version

MachineControl. Version for Windows NT. Digidesign Inc A Hillview Avenue Palo Alto, CA tel: fax:

AC/DC Modular Power Supply Series PMBus APPLICATION NOTES

DN-700C / DN-501C MIDI Command Guide

MultiCube. Modbus Data Tables. August Northern Design (Electronics) Ltd Bradford UK

Timecode Transcoder. Artistic Licence (UK) Ltd. Software Version V3.2 Manual Revision V1.07

EZ Protocol. Communication Protocol for EZPLC. For use of EZAutomation and AVG Customers with EZPLC Products. Copyright 2005 AVG

JX-3P MIDI Expansion Kit. User manual

328 XD FRONTIER DESIGN DAKOTA STEREO INPUTS. 0dBFS = 18dBu. MIX dbfs RIGHT SELECT MUTE AES/EBU SOLO EXIT FUNCTION S/PDIF PARAMETER CLOCK CLOCK

MIDI Reference CLP- 525

LMV2 / LMV3... Modbus. User Documentation. Building Technologies Division

EM24-DIN COMMUNICATION PROTOCOL. Version 3 Revision 1

Back to. Communication Products Group. Technical Notes. Local/Remote Control and Functional Description, 1:1 Redundant Switching Unit, One Rack Unit

Model IR4000M. Multi-Point Monitor Modbus programming guide

IS-Dev Kit-7 & 7D User s Manual

TASCAM HS-2/HS-20/HS-2000

automatic video source selection is commanded preferred video input is composite, color system PAL volume is -15 db

EM24-DIN PFA, PFB & X models

A2000 Multifunctional Power Meter Profibus Interface

Technical Note. SMART Command Feature Set for the M500DC. Introduction. TN-FD-26: M500DC SSD SMART Implimentation. Introduction

Digitakt OS 1.07 Release Information

Digitakt OS 1.06 Release Information

The benefits are ease of set-up, more data available for the user from the drive, fast control, and state of the art technology.

IS-Dev Kit-8 User Manual

Modbus Protocol For FTS/FTM 3x&8x

IS-Dev Kit-6, 6D, 6C, 6HB User s Manual

Technical Note. SMART Command Feature Set for the M510DC. Introduction. TN-FD-33: M510DC SSD SMART Implementation. Introduction

Euphonix TT007. Machine Control Hub for System 5 and CS Series Consoles. Operation Manual

NORITAKE ITRON VFD MODULES GU192x16H-K612C5

960L Software Version 3.0

Specification. For. Serial Interface DN-T645/625

Digitakt OS 1.10 Release Information

REV: PAGE: REVISION DESCRIPTION APPR: DATE: B - Released as a standard product. GRW 11/05/96

INVERTER E510. Communication Addendum. ModbusRTU/ASCI. DOCUMENT-TECO-E510-AC001 Ver01:

CLOCKIT CONTROLLER ACC501

CDSD DISC TRANSPORT USER MANUAL. Version 2.1

Application note Differential Pressure Sensor Type D6F-PH (Rev 1.0)

2006 ROLAND CORPORATION

* Option 1... High Profile Jog Wheel

COMMUNICATION M-BUS PROTOCOL CE4DMID0M (MBus meter)

F 0 2 M I D I R e f e r e n c e EN

migra CAN Large Format Graphics Compatible LED Display with CANopen Interface

OLED Engineering Kits User Manual

2. Terminal arrangement TEMPERATURE CONTROLLER KT2 COMMUNICATION INSTRUCTION MANUAL. (Fig. 2-1)

QEL - DEDESCO 5935 Ottawa Street Richmond, Ontario, Canada, K0A 2Z0.

MIDI CPU Firmware V User Manual

EM270 COMMUNICATION PROTOCOL. Version 1 Revision 0

MIDI Data Format / MIDI-Datenformat / Format des données MIDI / Formato de datos MIDI

MK2 Programmer s Reference Manual

328 XD WAVECENTER/PCI STEREO INPUTS. 0dBFS = 18dBu. MIX dbfs RIGHT SELECT MUTE AES/EBU SOLO EXIT FUNCTION S/PDIF PARAMETER CLOCK CLOCK IN OUT IN MIDI

1. Introduction. 2. Installation MODBUS INTERFACE

MPX 1 V1.10. MIDI Implementation Details

AKAI S5000/S6000 MIDI System Exclusive Protocol Specification

INTELLIS. Modbus Direct Network Monitor

X-SEL Serial Communication Protocol Specification (Format B)

DS1821 Programmable Digital Thermostat and Thermometer

DCP - Interface. Dynavert L. Technical Description July 2010 (Draft) Dynavert

Auto Pan Preset position Position feedback Endless Pan rotation Absolute position Go-To

M-Bus protocol CALEC energy master

LS-ADAT. Owner s Manual

Model IR700. Infrared Point Detector for Carbon Dioxide Gas Applications. Modbus Programming Guide

Communications Protocol

Q.link protocol ver Q.link protocol. QuickWood Automation /16

TIME MACHINE Data Formats (Sep jkuo: extracted from the TIME MACHINE user manual)

NORITAKE ITRON VFD MODULES GU128x18F-K612A2

1. Communication Data Frame

Information Sheet For. MSRK Module. fitted inside the

EM210 COMMUNICATION PROTOCOL. Version 3 Revision 3

PAXDP Modbus Register Table REVISED 12/03/12 LP0916A

NORITAKE ITRON VFD MODULES GU128x18F-K610A2

DELPHI CORPORATION. LIN to RS-232 Gateway Systems Analysis INterface Tool (SAINT) Users Guide

Main Menu MIDI page open & RX Channel list selected. The MIDI page of the Main Menu contains the following elements :

Transcription:

ALESIS M20 System Exclusive Fourth Revision August 5, 1999

ALESIS PDAT SYSTEM EXCLUSIVE The PDAT responds to all Alesis system exclusive ADAT commands, as well as MIDI Machine Control (MMC) commands. In addition, the PDAT also responds to and sends out Alesis system exclusive PDAT commands to access functions that may or may not be addressed by PDAT or MMC commands. Note: There may be some overlap in commands. For example, setting a locate address may be done using MMC, ADAT Sysex or PDAT Sysex commands. The PDAT has the following MIDI System Exclusive format: F0H 00H 00H 0EH 16H aah bbh data F7H Start-of-Exclusive Alesis manufacturer ID PDAT product ID Device id# (0..7EH, 7FH=all) Opcode (0..7FH) Data End-of-Exclusive PDAT System Exclusive Page 2

OPCODES Note: 1) Items in parentheses,{}, can be repeated multiple times 2) Items in square brackets, [], are optional, depending upon preceding info 01H - Write Parameter F0H 00H 00H 0EH 16H <dev#> 01H {<param#> [<sub-param>] <data>} F7H <param> - If = 0, then function bit to follow in sub-param position - If <> 0, then this value is the user parameter number <sub-param> - User bit parameter (range 0..13h) <data> - For User Parameters, see Parameter Table - For Sub-Parameters, 0=disabled and 7Fh=enabled Parameters (general user parameters) See Table 1 Sub-Parameters (user function bit parameters) 00 All Safe Enable 01 All Input Enable 02 Auto Input Enable 03 Auto Play Enable 04 Rehearse Enable 05 Online Enable 06 Auto AUX Routing Enable 07 Format Safe Enable 08 Format Enable 08 SMPTE Chase Enable 0A Internal Generator Enable 0B Tape Offset Enable 0C Track Delay Enable 0D Pre-Roll Enable 0E Post-Roll Enable 0F Auto Return Enable 10 Auto Record Enable 11 Fast Wind Mode Enable 12 Mute Audio Enable 13 CADI Connect Status (1=connected) 02H - Read Parameter F0H 00H 00H 0EH 16H <dev#> 02H 06H {<param#> [<sub-param>]} F7H <param> - 00 = bit parameter to follow in sub-param position Response: F0 00 00 0E 16 <dev#> 02H 07H {<param#> [<sub-param>] <data>} F7 03H - 04H - Jog Command F0H 00H 00H 0EH 16H <dev#> 03H <data-1> <data-2> F7H <data-1> - 000000ba a = jog speed<7>, b = direction (0=fwd, 1=rew) <data-2> - jog speed<6..0> Control Pause Tension F0H 00H 00H 0EH 16H <dev#> 04H F7H PDAT System Exclusive Page 3

05H - 06H - Search Switch Toggle F0H 00H 00H 0EH 16H <dev#> 05H <data> F7H <data> - search switch status (0=disable, 7Fh=enable) Master Search Mode F0H 00H 00H 0EH 16H <dev#> 06H <data> F7H <data> - master search mode status (0=master not in search mode, 7Fh=master in search mode) Information Query/Response Commands 07H - PDAT Software Version Inquiry F0H 00H 00H 0EH 16H <dev#> 07H F7H Request PDAT software version Note: For compatibility purposes, the PDAT also responds to the ADAT software version request with its ADAT software version equivalent (currently 4.03). Response: F0 00 00 0E 14 <dev> 44 <versionh> <versionl> F7 <versionh> - 0aaaaaaa = integer part (0..99) <versionl> - 0bbbbbbb = fractional part (0..99) 08H - PDAT Miscellaneous Info F0H 00H 00H 0EH 16H <dev#> 08H 06H F7H Request miscellaneous PDAT information Response: F0 00 00 0E 16 00 08H 07H <data-1> <data-2> F7 <data-1> = 0gfedcba where a = AUX record track status b = AUX input track status c = TC Track record track status d = TC Track input track status e = Online ADAT slave status f = Transport/system error status g = Transport task active status <data-2> = 000000ba where a = Digital input presence b = I/O card presence 09H - Slave Query F0H 00H 00H 0EH 16H <dev#> 09H 06H F7H Request number of ADATs connected Response: F0 00 00 0E 16 00 09H 07H <# of ADATs> F7 <# of ADATs> - 0..16 0AH - Timecode Query F0H 00H 00H 0EH 16H <dev#> 0AH 06H <type> F7H <type> - 0 = Search Master TC Request search master resting timecode <type> - 1 = Tape TC Request tape tc (TC Track) timecode Response: F0 00 00 0E 16 <dev#> 0AH 07H <type> <timecode>f7 <type> = same as requested <timecode> =32-bit timecode converted to 7-bit MIDI data bytes PDAT System Exclusive Page 4

Data Transfer Commands 10H - MIDI Sysex Dump F0H 00H 00H 0EH 16H <dev#> 10H 06H <type> F7H <type> - 0 = all Request dump of all user parameters Response: F0 00 00 0E 16 <dev#> 10H 07H <type> <byte count> <data>f7 <type> - 0 (complete user parameter dump = 1964 data bytes) <data> - 8 MIDI data bytes output for every 7 data bytes a7 a6 a5 a4 a3 a2 a1 a0 transfer as 00 a6 a5 a4 a3 a2 a1 a0 b7 b6 b5 b4 b3 b2 b1 b0 00 b5 b4 b3 b2 b1 b0 a7 c7 c6 c5 c4 c3 c2 c1 c0 00 c4 c3 c2 c1 c0 b7 b6 d7 d6 d5 d4 d3 d2 d1 d0 00 d3 d2 d1 d0 c7 c6 c5 e7 e6 e5 e4 e3 e2 e1 e0 0 e2 e1 e0 d7 d6 d5 d4 f7 f6 f5 f4 f3 f2 f1 f0 g7 g6 g5 g4 g3 g2 g1 g0 0 f1 f0 e7 e6 e5 e4 e3 0 g0 f7 f6 f5 f4 f3 f2 0 g7 g6 g5 g4 g3 g2 g1 11H - MIDI Software Dump F0H 00H 00H 0EH 16H <dev#> 11H <type> [data] F7H <dev#> always = 7FH <type> can be: 0 4 Meg Flash Boot segment data without interleaved checksum 1 4 Meg Flash Code segment data without interleaved checksum 2 4 Meg Flash Boot segment data with interleaved checksum 3 4 Meg Flash Code segment data with interleaved checksum 4 8 Meg Flash Boot segment data without interleaved checksum 5 8 Meg Flash Code segment data without interleaved checksum 6 8 Meg Flash Boot segment data with interleaved checksum 7 8 Meg Flash Code segment data with interleaved checksum If <type> is 0,1,4, or 5 (data without interleaved checksum) then [data] is: <#data bytes> <24 Bit Address> <data byte 1>.. <data byte N>........ <#data bytes = 2> <24 Bit Address = 0> <checksum word> where: <#data bytes> is sent as a single byte greater than 0 but less than 128. <24 Bit Address> is sent as 6 nibble-ized data bytes. For example, address 123456H is sent as 01H 02H 03H 04H 05H 06H. MSB first. <data byte> is sent as 2 nibble-ized data bytes. For example, data 98H is sent as 09H 08H. MSB first. <data byte> is repeated for <#data bytes>. <checksum word> is sent as 4 nibble-ized total checksum bytes. Note <#data bytes> must equal 2. <24 Bit Address> must equal 0. Repeat the <#data bytes> <24 Bit Address> <data byte 1>.. <data byte N> sequence for programming of additional flash locations. Note that the <24 Bit Address> specifies the start of programming location for the specified <data byte> s. Always complete the end of the transmission with the checksum sequence above. If <type> is 2,3,6, or 7 (data with interleaved checksum) then [data] is: <#data bytes> <24 Bit Address> <data byte 1>.. <data byte N> <checksum>.......... PDAT System Exclusive Page 5

<#data bytes> <24 Bit Address> <data byte 1>.. <data byte N> <checksum> where: <#data bytes> is sent as a single byte greater than 0 but less than 128. <24 Bit Address> is sent as 6 nibble-ized data bytes. For example, address 123456H is sent as 01H 02H 03H 04H 05H 06H. MSB first. <data byte> is sent as 2 nibble-ized data bytes. For example, data 98H is sent as 09H 08H. MSB first. <data byte> is repeated for <#data bytes>. <checksum> is sent as 2 nibble-ized checksum bytes. The checksum is the sum of the previous <data byte> sequence mod 256. Repeat the <#data bytes> <24 Bit Address> <data byte 1>.. <data byte N> <checksum> sequence for programming of additional flash locations. Note that the <24 Bit Address> specifies the start of programming location for the specified <data byte> s. 12H - Tape Data F0H 00H 00H 0EH 16H <dev#> 12H <type> F7H <dev#> device <type> can be: 0 Prepare data to save to tape 1 Initiate a save data to tape Action Commands 16H - Locate F0H 00H 00H 0EH 16H <dev#> 16H <loc#> F7H <loc#> - 0..99=locate 0.. locate 99 17H - Inject Tape F0H 00H 00H 0EH 16H <dev#> 17H F7H 18H - Enter Deck Standby F0H 00H 00H 0EH 16H <dev#> 18H F7H PDAT System Exclusive Page 6

Parameter Table Parameter Name <param> <data> Comments VU Peak Hold Mode 1 01h 0..2 0 = No Peak Hold 1 = Momentary 2 = Continuous VU Peak Hold Time 1 02h 0.. 99 Amount of time the peak pixel is held on VU Decay Time 1 03h 0.. 99 Amount of time it takes each VU pixel to decay VU Meter Scale 1 04h 0..1 VU meter scale 0 = Normal 1 = Fine db VU Fine Headroom 1 05h 2..22 db Amount of headroom for Fine db scale Digital Source 1 06h 0..2 0 = ADAT Optical 1 = Track Copy 2 = I/O Card (only valid if I/O card detected) Input Select Bitmap 2 07h bitmap (0=analog input, 1=digital input) Analog Routing 1 08h 0..2 0 = one-to-one 1 = half and half 2 = odd-even ADAT Optical Source 2 09h optical source bitmap (1=source channel) Track Copy Source 2 0Ah track copy source bitmap (1=source channel) AES/EBU Source 2 0Bh AES/EBU source bitmap (1=source channel) AUX Track Source 2 0Ch AUX source bitmap (1=source channel) [1..8 1..8] [1..4 5..8] [chan 1 1,3,5,7 and chan 2 2,4,6,8] Pre-Roll Time 1 0Dh 0..25 Post-Roll Time 1 0Eh 0..25 Loop Start Point 1 0Fh 0..99 Loop start locate number Loop End Point 1 10h 0..99 Loop end locate number Auto Punch-In Point 1 11h 0..99 Auto Punch-In locate number Auto Punch-Out Point 1 12h 0..99 Auto Punch-Out locate number Locate Address 13h <loc #> <32-bit timecode> <loc #> = 0..99 <32-bit timecode> = MIDI data format 5 Locate Name 14h <loc #> <8-character ASCII> <loc #> = 0..99 <8-character ASCII> = <left-most>..<rt-most Format Type 1 15h 0..1 0 = 16-bit 1 = 20-bit Track Delay Value 3 16h [<track #> <value>] <track #> = 0..7 <value> = 0..8160 samples Tape Offset Value 5 17h 32-bit sample PDAT System Exclusive Page 7

Parameter Name <param> <data> Comments SMPTE Offset Value 7 18h Signed SMPTE format Chase Mode 1 19h 0..1 0 = Continuous 1 = Once Flywheel Amount 2 1Ah 0..150 frames <msb> <lsb> # of frames to flywheel when chasing SMPTE <msb> = 0aaa aaaa (bit 0..6) <lsb> = 0bbb bbbb (bit 7..13) Park Ahead 5 1Bh 32-bit timecode (samples) Distance to stop ahead of last good SMPTE In Internal Gen Mode 1 1Ch 0..1 0 = Free-run 1 = Play/Rec Int Gen Start Reference 1 1Dh 0..2 0 = ABS Time 1 = TC Track 2 = User Set Int Gen ABS Offset 6 1Eh 32-bit timecode When Start Ref = ABS Time, current ABS Time plus this offset gives the starting timecode Int Gen User Set Start 6 1Fh SMPTE time format Int Gen User Bits 5 20h 8 hex characters Varispeed 4 21h -300..200 cents (FED4..00C8) MIDI Device ID 2 22h 0..127 (127 = 7Fh = All Call) MMC Output 0 23h 0..1 0 = MMC output disabled 1 = MMC output enabled MTC Output 0 24h 0..1 0 = MTC output disabled 1 = MTC output enabled Dig Output Format 1 25h 0..3 0 = 20-bit 1 = 16-bit 2 = 16-bit dithered 3 = Dig Thru mode (pass DigIn to DigOut) One-button Record 0 26h 0..1 0 = One-button record disabled 1 = One-button record enabled Direct Input Monitor 0 27h 0..1 0 = ADC/DAC 1 = Direct input TC Output Level 1 28h 0..30 (divide by 10 to get volts) Fwd/Rew SMPTE Out 0 29h 0..1 0 = SMPTE output in fwd/rew disabled 1 = SMPTE output in fwd/rew enabled Search Enable Mode 0 2Ah 0..1 0 = Normal 1 = Button only PDAT System Exclusive Page 8

Parameter Name <param> <data> Comments Locate Before Play 0 2Bh 0..1 0 = Disabled 1 = All slaves located to master before play Mute Until Locked 0 2Ch 0..1 0 = Each unit unmutes once it is in sync 1 = Units mute until master sees all locked Dynamic Punch 0 2Dh 0..1 0 = Punch using Play/Record buttons only 1 = Punch from track enable buttons allowed Track Group Enable 0 2Eh 0..1 0 = Track enable group buttons inactive 1 = Track enable group buttons active Track Enable Group buttons are on the CADI Unthread Timeout 1 2Fh 1..20 minutes Crossfade Time 1 30h 0..31 Remote Source 1 31h 0..2 0 = ADAT Sync 1 = MIDI 2 = RS-422 (Sony 9-pin protocol) Online Control Mode 1 32h 0..1 0 = Remote Only 1 = Remote and Local This allows the user to select which remote source is in control when Online is enabled. This allows the user to select whether front panel and LRC (both considered Local) are allowed when Online is enabled. Tape Counter Mode 1 33h 0..2 0 = SMPTE 1 = ABS Time 2 = RELATIVE Reference Counter Mode 1 34h 0..4 0 = SMPTE IN 1 = LOC PT 2 = TAPE TC 3 = INT GEN 4 = OFFSET Clock Source 1 35h 0..6 0 = Internal 1= Video 2 = ADAT 3 = I/O Card 4 = Word 5 = SMPTE 6 = Optical Sample Rate 1 36h <0..3> range 0..1 (0=48K, 1=44.1K) <4..7> range 0..2 (0=no pull-up/down, 1=pull-up, 2 = pull-down) SMPTE Rate 1 37h 0..5 0 = 24 fps 1 = 25 fps 2 = 29.97 fps 3 = 29.97 DF 4 = 30 fps 5 = 30 DF Displays current SMPTE Input Displays current locate address Displays TC Track of loaded tape Displays the Internal Generator Displays the SMPTE or Tape Offset PDAT System Exclusive Page 9

Parameter Name <param> <data> Comments Timecode Source 1 38h 0..1 0 = Internal 1 = External Chase Reference 1 39h 0..1 0 = ABS Time 1 = Tape TC Track Pitch Mode 1 3Ah 0..1 0 = Fixed 1= Variable RMD Error Enable 0 3Ch 0..1 0 = RMD Error LEDs inactive 1 = RMD Error LEDs active Digital Scan Enable 0 3Dh 0..1 0 = Digital scan disabled 1 = Digital scan enabled RMD = Remote Meter Bridge Yellow error LED indicates interpolation errors Red error LED indicate transport/system errors No audio while jog/shuttle Hear digital audio (scrub) while in jog/shuttle Digital Scan Level 1 3Eh 0..7 0= -42 db, 1= -36 db, 2= -30 db, 3= -24dB 4= -18 db, 5= -12 db, 6= -6 db, 7= 0 db Pseudo Master 1 3Fh 0..15 = device ID of the pseudo master 0 = ID1 = no pseudo master RS-422 Trk Arm Enable 0 40h 0..1 0 = RS-422 track arming disabled 1 = RS-422 track arming enabled Ignore RS-422 Edit Preset command RS-422 Track Mapping 1 41h 0..1 0=no mapping 1=odd/even Mapping options for 2-track Edit Preset 1 1, 2 2 1 1,3,5,7 and 2 2,4,6,8 PDAT System Exclusive Page 10

MIDI Data Format Types 0 Bit Parameter - Normal data format: 0 or 1 - MIDI data format: 0 (disabled) or 7Fh (enabled) 1 Byte Parameter with max value less than 80h - Normal data format: 0 a 6 a 5 a 4 a 3 a 2 a 1 a 0 - MIDI data format: <0 a 6 a 5 a 4 a 3 a 2 a 1 a 0 > 2 Byte Parameter with max value greater than or equal to 80h - Normal data format: a 7 a 6 a 5 a 4 a 3 a 2 a 1 a 0 - MIDI Data Format: <0 a 6 a 5 a 4 a 3 a 2 a 1 a 0 > <0 0 0 0 0 0 0 a 7 > 3 Word Parameter with max value less than 4000h (2 14 ) - Normal data format: 0 0 b 5 b 4 b 3 b 2 b 1 b 0 a 7 a 6 a 5 a 4 a 3 a 2 a 1 a 0 - MIDI Data Format: <0 a 6 a 5 a 4 a 3 a 2 a 1 a 0 > <0 b 5 b 4 b 3 b 2 b 1 b 0 a 7 > 4 Word Parameter with max value greater than or equal to 4000h (2 14 ) - Normal data format: 0 0 b 5 b 4 b 3 b 2 b 1 b 0 a 7 a 6 a 5 a 4 a 3 a 2 a 1 a 0 - MIDI Data Format: <0 a 6 a 5 a 4 a 3 a 2 a 1 a 0 > <0 b 5 b 4 b 3 b 2 b 1 b 0 a 7 > 5 Long Parameter - Normal data format: d 7 d 6 d 5 d 4 d 3 d 2 d 1 d 0 c 7 c 6 c 5 c 4 c 3 c 2 c 1 c 0 b 7 b 6 b 5 b 4 b 3 b 2 b 1 b 0 a 7 a 6 a 5 a 4 a 3 a 2 a 1 a 0 - MIDI Data Format: <0 a 6 a 5 a 4 a 3 a 2 a 1 a 0 ><0 b 5 b 4 b 3 b 2 b 1 b 0 a 7 ><0 c 4 c 3 c 2 c 1 c 0 b 7 b 6 ><0 d 3 d 2 d 1 d 0 c 7 c 6 c 5 ><0 0 0 0 d 7 d 6 d 5 d 4 > 6 SMPTE Parameter - Normal data format: hr:min:sec:frm - MIDI Data Format: <hour> <min> <sec> <frm> <hour> = 000hhhhh range=0..23 <min> = 00mmmmmm range=0..59 <sec> = 00ssssss range=0..59 <frm> = 000fffff range=0..29 7 SMPTE Parameter - Normal data format: hr:min:sec:frm:sfrm:smp - MIDI Data Format: <sign/hour> <min> <sec> <frm> <sfrm> <smp> <sign/hour> = 00shhhhh where s=0: positive, s=1:negative and hhhhh range=0..23 <min> = 00mmmmmm range=0..59 <sec> = 00ssssss range=0..59 <frm> = 000fffff range=0..29 <sfrm> = 0xxxxxxx range=0..99 <smp> = 000yyyyy range=0..19 PDAT System Exclusive Page 11