R3-GE1 BEFORE USE... INSTALLATION POINTS OF CAUTION INSTRUCTION MANUAL ETHERNET INTERFACE MODULE MODEL. (Modbus/TCP)

Similar documents
PWR. Power Module Slots

R6-NE1 BEFORE USE... POINTS OF CAUTION INSTRUCTION MANUAL ETHERNET INTERFACE MODULE MODEL. (Modbus/TCP, for 32-point analog signals)

R7D-RR8 BEFORE USE... POINTS OF CAUTION. INSTRUCTION MANUAL REMOTE CONTROL RELAY CONTROL MODULE, 8 points MODEL. (DeviceNet)

R6-NC1 BEFORE USE... POINTS OF CAUTION. INSTRUCTION MANUAL CC-Link INTERFACE MODULE MODEL. (CC-Link Ver.1.10; for 16-point analog signals)

R3-NE1 ETHERNET INTERFACE MODULE MODEL. Remote I/O R3 Series. (Modbus/TCP)

MODEL: R3-NE1. Remote I/O R3 Series. ETHERNET INTERFACE MODULE (Modbus/TCP) 27.5 (1.08)

R3-NL2 INSTALLATION BEFORE USE... POINTS OF CAUTION INSTRUCTION MANUAL LONWORKS INTERFACE MODULE MODEL. (I/O 56 points)

R3-NL1 LONWORKS INTERFACE MODULE BEFORE USE... INSTALLATION POINTS OF CAUTION INSTRUCTION MANUAL. R3-nL1 MODEL

BEFORE USE... POINTS OF CAUTION. INSTRUCTION MANUAL PNP TRANSISTOR OUTPUT MODULE, 16 points (MECHATROLINK-I / -II, short circuit protection)

R1M-GH BEFORE USE... POINTS OF CAUTION INSTRUCTION MANUAL PC RECORDER MODEL. (thermocouple or DC input, 16 points)

R1M-GH BEFORE USE... POINTS OF CAUTION INSTRUCTION MANUAL PC RECORDER MODEL. (thermocouple or DC input, 16 points)

NPN / PNP DISCRETE INPUT & NPN TRANSISTOR OUTPUT MODULE, 16 points each

MODEL: R2K-1 SEN TRONIC AG. R2K Series

R1M-J3 BEFORE USE... POINTS OF CAUTION INSTRUCTION MANUAL RTD & POTENTIOMETER INPUT MODULE MODEL. (8 points)

NPN/PNP DISCRETE HIGH SPEED INPUT & NPN TRANSISTOR OUTPUT MODULE

DLS-E2 TELEMETERING UNIT BEFORE USE... POINTS OF CAUTION INSTRUCTION MANUAL MODEL. (16 contact inputs & 16 open collector outputs)

MODEL: M5DY SEN TRONIC AG CURRENT LOOP SUPPLY. [2] POWER INPUT AC Power M: V AC (Operational voltage range V, Hz)

R1M-GH THERMOCOUPLE & DC INPUT MODULE MODEL. Remote I/O R1M Series. (16 points)

MODEL: GR8-EM. Communication Adaptor GR8 Series

MODEL: WL40EW2F. Wireless I/O WL40F Series

INSTRUCTION MANUAL 2-WIRE UNIVERSAL TEMPERATURE TRANSMITTER

CONTENTS 1. BEFORE USE GENERAL DESCRIPTION POINTS OF CAUTION HARDWARE SPECIFICATIONS... 4

Du line. Dupline Field- and Installationbus Dupline Ethernet Modbus/TCP Gateway Type G G Type Selection

MODEL: R3-NFL1. SPECIFICATIONS OF OPTION: Q COATING (For the detail, refer to M-System's web site.) Remote I/O R3 Series

NA User Manual. Copyright(C) * CREVIS Co.,Ltd * Support * URL :

MODEL: IT40SW2. Tower Light Series. [2] LAMP 1 COLOR (1st layer from the top) R: Red Y: Amber G: Green B: Blue W: White

ECAN-240. (Modbus TCP to 2-port CAN Bus Gateway User manual) ECAN-240 Modbus TCP to 2-port CAN Bus Gateway User Manual, Version 1.0.

Conformance Test Policy for the Modbus/TCP Conformance Test Laboratory. Version 1.1. The University of Michigan Modbus/TCP Conformance Test Laboratory

EGW1-IA3-MB User s Manual

MODEL: R1M-A1. PC Recorders R1M Series. SPECIFICATIONS OF OPTION: Q COATING (For the detail, refer to M-System's web site.)

MODEL: R1M-D1. PC Recorders R1M Series. SPECIFICATIONS OF OPTION: Q COATING (For the detail, refer to M-System's web site.)

SEM3 - Embedded Micro Metering Module

MODEL: R1M-P4. PC Recorders R1M Series. SPECIFICATIONS OF OPTION: Q COATING (For the detail, refer to M-System's web site.)

Conformance Test Policy for the Modbus/TCP Conformance Test Laboratory. Version 2.0. The University of Michigan Modbus/TCP Conformance Test Laboratory

Embedded Modbus TCP Module GS11-MT. User Manual REV 1.1. SST Automation.

T1K MODBUS Base Controller Specifications

RTD-NET Installation Instructions

MODEL: M1EXV. OUTPUT Field-selectable DC Output Current output: 0-20 ma DC Voltage output: V DC Voltage output: V DC

HART / EtherNet/IP Gateway GT200-HT-EI User Manual V 1.0 REV A SST Automation

MXM-50. Modbus Interface for Mitsubishi Air-Conditioning. Installation and User Guide.

Managed 100 Mbps Ethernet Switches TOP FRONT. Click 340/341/342

MODEL: R3-NL2. RELATED PRODUCTS XIF File (Device Interface File) XIF file is used to define a LonWorks device when programmed on LonMaker.

Industrial 1-port RS422/485 Modbus Gateway IMG-110T

PROFIBUS DP/CAN Gateway PCA-100. User Manual

Motortronics VirtualSCADA VS2-MT Communication Gateway VS2-MT User Manual Revision

MODEL: 40DN. Digital Panel Meters 40 Series

HITACHI. EH-150 series PLC EH-RTD8 Resistance Temperature Detective input module Instruction manual. Safety precautions

Description of options. user s manual. DEIF A/S Frisenborgvej 33 DK-7800 Skive Tel.: Fax:

MODEL CIO-EN MODBUS/TCP, MODBUS/RTU I/O MODULE

MOD-MUX MODBUS TCP I/O PRODUCTS

MODBUS APPLICATION PROTOCOL SPECIFICATION V1.1b3 CONTENTS

INDEX. Document Name : User Manual for SC10EJ Serial to Ethernet Converter

Analog Input/Output Modules

Do-more H2 Series PLC System Specifications

Fieldgate SFG500. Technical Information. Intelligent Ethernet/PROFIBUS gateway

HART/ Modbus TCP Gateway GT200-HT-MT User Manual V 1.2 REV A SST Automation

SAFETY PRECAUTIONS CAUTION WARNING CAUTION. Thank you for purchasing ig5a Series Profibus Communication Module

MODBUS APPLICATION PROTOCOL SPECIFICATION V1.1b3 CONTENTS

QUCM Limitorque Controller

VERIS H8035 and H8036

Industrial 2-port RS422/485 Modbus Gateway IMG-120T

SST Automation

Operation Manual First Edition

MODEL: M1EXM. OUTPUT Field-selectable DC Output Current output: 0-20 ma DC Voltage output: V DC Voltage output: V DC

MODBUS Protocol for MiCOM P30 Series

XPSMF35. Product data sheet Characteristics. Preventa safety PLC compact - Profibus DP protocol. Main. Complementary. Safety module name

Conformance Test Policy for the Modbus/TCP Conformance Test Laboratory. Version 1.0. The University of Michigan Modbus/TCP Conformance Test Laboratory

P2 Configuration Guide

Appearance Size (mm) Power supply voltage Model (W H D) 100 to 240 VAC K3SC to 240 VAC

General Specifications

PAC BI-DP BIM and 8701-CA-BI Carrier

* * Ethernet [Modbus/TCP] Communication Converter COM-JL. [For SRZ] Instruction Manual IMR01Y37-E3 RKC INSTRUMENT INC.

WEB-ENABLED REMOTE TERMINAL UNIT Model: DL8 USERS MANUAL

MB40 & MB45 MODBUS TCP/IP Gateway Handbook

Advantys ETB. DATA SHEET Advantys ETB IP 67 Ethernet Digital I/O Modules. Description. Features

D-100 FLOW DISPLAY MODBUS Network Interface Installation Guide

MSD-SRF2XM Multi-port RS-232 to Ethernet Data Gateway User Manual

MODEL: R3-NL1. RELATED PRODUCTS XIF File (Device Interface File) XIF file is used to define a LonWorks device when programmed on LonMaker.

CONFIGURATION HANDBOOK

ABB Drives. User s Manual. Modbus Adapter Module RMBA-01

Gateway 1400 Reference Manual

TRP-C37. Ethernet to RS232/422/485 Converter. User s Manual. Printed September Rev 1.6

isma-b-mg-ip User Manual Global Control 5 Sp. z o.o. Poland, Warsaw

MODEL: M2EXM. Super-mini Signal Conditioners with Display Mini-M M2E Series

Industrial 1-port RS422/485 Modbus Gateway

Intech Micro 2300-RO4 analogue input station MODBUS RTU slave application supplementary manual.

MGate 5111 Quick Installation Guide

GW-7238D J1939 to Modbus TCP Server / RTU Slave Gateway

PROLOGIC Modular PLC CPU & I/O Modules Catalog and Design Guide

MODEL: DL8. POWER INPUT DC power R: 24 V DC (Operational voltage range: ±10 %; ripple 10 %p-p max.) Web Data Logger DL8

BL compact multiprotocol fieldbus station for Industrial Ethernet 8 Analog Inputs for Current or Voltage BLCEN-8M12LT-4AI-VI-4AI-VI

User Manual Anybus Modbus TCP/RTU Gateway

USB-L111. USB-L111 User Manual TPM. Version: V M05. To properly use the product, read this manual thoroughly is necessary.

IntesisBox Modbus Server KILSEN KSA-7xx. User s Manual 08/2013 r1.2 eng

Carbon Monoxide Sensor - ModBus

CJ Series EtherNet/IP TM Connection Guide. SMC Corporation Solenoid Valve (SI Unit EX600-SEN#) P657-E1-01

EQ-DCM User Manual Revision 1.02 Sep 10, 2013

RTD-RA. realtime. Installation Instructions. English A B. Installation Instructions Control Systems LEDS ALL DIMENSIONS IN MM

Industrial 2-port RS422/485 Modbus Gateway

EE360. High-End Moisture in Oil Transmitter. Typical applications. Features EE360 EE360. (+34)

Transcription:

INSTRUCTION MANUAL ETHERNET INTERFACE MODULE (Modbus/TCP) MODEL BEFORE USE... Thank you for choosing M-System. Before use, please check contents of the package you received as outlined below. If you have any problems or questions with the product, please contact M-System s Sales Office or representatives. PACKAGE INCLUDES: Network interface module...() MODEL NO. Confirm Model No. marking on the product to be exactly what you ordered. INSTRUCTION MANUAL This manual describes necessary points of caution when you use this product, including installation, connection and basic maintenance procedures. POINTS OF CAUTION CONFORMITY WITH EU DIRECTIVES The equipment must be mounted inside the instrument panel of a metal enclosure. The actual installation environments such as panel configurations, connected devices, connected wires, may affect the protection level of this unit when it is integrated in a panel system. The user may have to review the CE requirements in regard to the whole system and employ additional protective measures to ensure the CE conformity. HOT INSERTION/REMOVAL OF MODULES It is possible to replace the module with the power is supplied. Be sure to replace it when the module is not communicating with a host, as it is possible to affect the system. However, replacing multiple modules at once may greatly change line voltage levels. We recommend that you replace them one by one. GENERAL PRECAUTIONS Do NOT set the switches while the power is supplied. The switches are used only for maintenance without the power. ENVIRONMENT Indoor use. When heavy dust or metal particles are present in the air, install the unit inside proper housing with sufficient ventilation. Do not install the unit where it is subjected to continuous vibration. Do not apply physical impact to the unit. Environmental temperature must be within -0 to +55 C ( to F) with relative humidity within 0 to 90% RH in order to ensure adequate life span and operation. WIRING Do not install cables close to noise sources (relay drive cable, high frequency line, etc.). Do not bind these cables together with those in which noises are present. Do not install them in the same duct. AND... The unit is designed to function as soon as power is supplied, however, a warm up for 0 minutes is required for satisfying complete performance described in the data sheet. INSTALLATION Use the Installation Base Model: R-BS, or Model: R-BSW for free I/O address capability. Before mounting the Network Interface Module onto the base, be sure to configure the module as explained below. DATA ALLOCATION Use the side DIP SW to set the number of slots which the module is assigned to. See TRANSMISSION DATA DESCRIPTIONS. NETWORK SLOTS ON THE BASE I/O I/O I/O n With Model R-BS base, mount the I/O Modules from the left end (I/O ) to the right in order that the Network Module assigns data areas from I/O. Network Module(s) and Power Module are mounted basically at the right end though technically they could be mounted in any position. With Model R-BSW base, there is no limitation in mounting positions as I/O address can be assigned freely to each module using rotary switches equipped on the base. It is available to assign the module to max. 8 slots. The assigned slots numbers can not be used again for the real I/O modules which need to be mounted on the same base. Don t set the interface module for more than 6 slots as it can not read the data for more than 6 modules. EM-86 Rev.5 P. / 7

COMPONENT IDENTIFICATION FRONT VIEW SIDE VIEW RUN LED Rotary SW (unused) ERR LED Rotary SW (unused) Functions Configuration Jack RJ-5 Modular Jack 5 6 Ethernet Indicator LINK DPLX (Duplex) LINK0 (0Mbps) LINK00 (00Mbps) COL (Collision) SW ON LED Functions Module Allocation 8 7 6 5 SW ON ETHERNET INDICATOR ID COLOR FUNCTION LINK Red ON at LINK DPLX Red ON at full-duplex communication LINK0 Red ON at 0 Mbps connection LINK00 Red ON at 00 Mbps connection COL Red Blink at collision SIDE DIP SW (*) Factory setting Module Allocation: SW-, -, - MODULE SW- SW- SW- OFF(*) OFF(*) OFF(*) ON OFF OFF OFF ON OFF ON ON OFF 5 OFF OFF ON 6 ON OFF ON 7 OFF ON ON 8 ON ON ON LED Function: SW- Functions assigned to the front RUN and ERR LEDs can be selected. LED FUNCTION SW- RUN ERR OFF(*) Modbus/TCP communication and the field bus built-in R interface module are in normal Green ON/blinks in communication errors (OFF with wire breakdown; blinks with setting errors.) ON Red when receiving Red when transmitting Note: Be sure to set unused SW- through -8 and SW- through - to OFF. PC CONFIGURATOR With configurator software, settings shown below are available. Refer to the software manual of RCON for detailed operation. INTERFACE MODULE SETTING PARAMETER AVAILABLE RANGE DEFAULT SETTING Time 0. 00.0 (sec.).0 (sec.) IP Address 55.55.55.55 9.68.0. Subnet Mask 55.55.55.55 55.55.55.0 TCP Socket: Port to Port 0 767 50 Linger: to 0.0 76.7 (sec.) 80.0 (sec.) EM-86 Rev.5 P. / 7

TERMINAL CONNECTIONS Connect the unit as in the diagram below. EXTERNAL DIMENSIONS unit: mm (inch) 7.5 (.08) 09 (.9) POSITIONING GUIDE 0 (5.) 6 M SCREW 5 6 6. (.) TERMINAL COVER CONNECTION DIAGRAM Modbus/TCP RJ-5 MODULAR JACK RUN + RUN CONTACT OUTPUT RUN CONFIGURATION JACK JACK BUS CONNECTOR INTERNAL BUS INTERNAL POWER WIRING INSTRUCTIONS M SCREW TERMINAL Torque: 0.5 N m SOLDERLESS TERMINAL unit: mm (inch) Refer to the drawing below for recommended ring tongue terminal size. Spade tongue type is also applicable. Solderless terminals with insulation sleeve do not fit. Applicable wire size: 0.75.5 mm Recommended manufacturer: Japan Solderless Terminal MFG. Co.,Ltd., Nichifu Co.,ltd. (.) max. min. (.6). (.) dia. 6 max. (.) (.7) max. EM-86 Rev.5 P. / 7

CHECKING ETHERNET CONNECTION IP ADDRESS The does not support BootP Table Software. The IP Address and Subnet Mask can be configured by using the RCON Configurator Software. The Modbus/TCP Port No. is fixed to 50. DATA ALLOCATION Set data allocation by using the side DIP SW. This setting specifies that how many slots the module is assigned to. Based on the setting, the data areas are allocated to the related slots. WIRING Connect an Ethernet cable to the front RJ-5 jack. CHECK LED When wiring is correct, LINK and LINK0, or LINK and LINK00 are turned on. When the module is receiving or sending data, LINK0 or LINK00 blinks.* * ON for firmware version V.00 or later CHECK CONNECTION Enter ping command on the Windows MS-DOS prompt as follows: C: WINDOWS>ping ***.***.***.*** (***.***.***.***: Enter IP address in decimal.) ping ***.***.***.*** with bytes of data: Reply from ***.***.***.*** : bytes= time<0ms TTL=6 Reply from ***.***.***.*** : bytes= time<0ms TTL=6 Reply from ***.***.***.*** : bytes= time<0ms TTL=6 Reply from ***.***.***.*** : bytes= time<0ms TTL=6 Ping statistics for ***.***.***.*** Packets:Sent=,Received=,Lost=0(0% loss) When the connection is normal, the replies are as shown above. When the connection fails due to a problem such as a wrong IP address, the reply will be something else, e.g. time over. CHECK CONNECTION TO THE APPLICATION SOFTWARE Check Point : LINK LEDs When a normal connection is established, the front LINK and LINK0 or LINK00 are turned on regardless of data sending/ receiving status. Check power supply to the hub in case that these LEDs are not on. Check Point : RUN Indicator LED When the side DIP SW- is set to OFF, the RUN Indicator LED turns to Green if and R communication interface module send/receive data in normal. Check Point : Sending/Receiving Indicators When the side DIP SW- is set to ON, the RUN Indicator LED turns to Red in data receiving, and the ERR Indicator LED turns to Green in data sending. In normal operating conditions, these LEDs may seem to blink at once due to the high speed transmission. EM-86 Rev.5 P. / 7

MODBUS FUNCTION CODES & SUPPORTED CODES Data and Control Functions CODE NAME 0 Read Coil Status Digital output from the slave 0 Read Input Status X Status of digital inputs to the slave 0 Read Holding Registers X General purpose register within the slave 0 Read Input Registers X Collected data from the field by the slave 05 Force Single Coil Digital output from the slave 06 Preset Single Registers X General purpose register within the slave 07 Read Exception Status 08 Diagnostics X 09 Program 8 0 Poll 8 Fetch Comm. Event Counter Fetch a status word and an event counter Fetch Comm. Event Log A status word, an event counter, a message count and a field of event bytes Program Controller Poll Controller 5 Force Multiple Coils X Digital output from the slave 6 Preset Multiple Registers X General purpose register within the slave 7 Report Slave ID Slave type / RUN status 8 Program 88 / M8 9 Reset Comm. Link 0 Read General Reference Write General Reference Mask Write X Register Read / Write X Registers Read FIFO Queue Exception Codes CODE NAME 0 Illegal Function X Function code is not allowable for the slave 0 Illegal Data Address X Address is not available within the slave 0 Illegal Data Value X Data is not valid for the function 0 Slave Device Failure 05 Acknowledge 06 Slave Device Busy 07 Negative Acknowledge 08 Memory Parity Error Diagnostic Subfunctions CODE NAME 00 Return Query Data X Loop back test 0 Restart Comm. Option X Reset the slave and clear all counters 0 Return Diagnostic Register X Contents of the diagnostic data ( bytes) 0 Change ASCII Input Delimiter X Delimiter character of ASCII message 0 Force Listen Only Mode X Force the slave into Listen Only Mode EM-86 Rev.5 P. 5 / 7

Modbus I/O ASSIGNMENTS ADDRESS DATA TYPE DATA MODULE POSITION Input (X) 05 0 Module Status Input Registers (X) 6 I Analog Input 7 8 9 6 65 80 5 8 96 6 97 7 8 8 57 7 F Analog Input 7 88 89 0 05 0 6 5 7 5 6 5 68 7 69 8 8 Holding Registers (X) 6 I Analog Output 7 8 9 6 65 80 5 8 96 6 97 7 8 8 57 7 F Analog Output 7 88 89 0 05 0 6 5 7 5 6 5 68 7 69 8 8 DATA TYPE I: Integer, 0 0000 (0 00%) F: Floating (-bit data cannot be accessed via floating addresses.) Note: DO NOT access addresses other than the ones mentioned above. Such access may cause problems such as malfunction. Module Status Module Status indicates whether individual I/O module is mounted or not. The bit corresponding to the mounted slots turns to, and the unmounted slots to 0. EM-86 Rev.5 P. 6 / 7

TRANSMISSION DATA DESCRIPTIONS Use the DIP SW located at the side of the module to specify module allocation. module is equivalent to I/O module with 6 words analog input and 6 words analog output. Max. 8 modules (8 words input, 8 words output) transmission is available. seems as if max. 8 I/O modules are mounted to 8 slots via Modbus/TCP. The input of the module is processed as follows. Modbus Communication Module R Base R Communication Module In responding to the input, the output (Holding Register) command becomes valid via Modbus/TCP communication, and the input (Input Register) command is valid in the output. Note: Do not mount any modules in the slots which are occupied by virtual modules. If a real I/O module is mounted in the slot, an internal bus error occurs and the ERR LED turns on. Max. 6 real I/O modules and virtual modules are available. The interface module can not read the data for more than 6 modules. WHEN IS MOUNTED TO SLOT ( modules) In practice, I/O modules are mounted to slot and slot. The R-NC in slot 7 recognizes the R-SV in slot directly. However, the R-NC recognizes the in slot as if modules are mounted to from slot to 5. R-BS08 R- SV R- GE R- NC R- PS SLOT REAL MODULE VIRTUAL MODULE DATA Slot R-SV R-SV Words Slot (/) 6 Words Slot No module (/) 6 Words Slot No module (/) 6 Words Slot 5 No module (/) 6 Words Slot 6 No module No module 5 6 7 8 Slot 7 R-NC R-NC Slot 8 R-PS R-PS INPUT/OUTPUT DATA MODULE STATUS Module Status indicates whether individual I/O module is mounted or not, normal or not. 5 0 Module (Slot ) Module (Slot ) Module (Slot ) Module 8 (Slot 8) ANALOG INPUT/OUTPUT DATA 5 0 6 bits binary data EM-86 Rev.5 P. 7 / 7