IECEx Certificate of Conformity Annexe

Similar documents
IECEx Certificate of Conformity Annexe

IECEx Certificate of Conformity

Operating instructions (Safety-related part ATEX and IECEx) Inductive NAMUR sensors NN504A NN505A NN506A NN507A /00 08/2015

The 470-Z1 consists of an aluminium enclosure, which has the supply / interface connections either via the bottom side or enclosure back panel.

Power supply unit NG3-16ib

M E M O R A N D U M I.S.

IECEx Certificate of Conformity

INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres

Terminal Boxes Series 8118

ECE Cert.fic te of Con ormity

INTRINSICALLY SAFE Ex ia PSU TYPE AC36W

Refer to attachment for more details. Andreas Meyer

5 Fieldbus Technology

IECEx Certificate of Conformity

BA304D Intrinsically safe loop-powered 3½ digit field mounting indicator issue 12

Safety instructions VEGATOR 121, 122

Page 1 of 5. Increased Safety, Encapsulation and Dust

Linear Luminaire with LED Series 6012/5

IECEx Certificate of Conformity

IECEx Certificate of Conformity

Series Panel Mounted Control Devices

Inductive angle sensor with analog output Ri360P1-DSU35TC-ELi-Exi

IECEx Certificate of Conformity

Installation & Operation Manual

Cerabar S PMC71, PMP71, PMP ma HART, PROFIBUS PA, FOUNDATION Fieldbus

Termination Board FC-GPCS-SAI16-PF. Features. Assembly. Function. Connection. SAI-1620m HART 24 V DC (I), 24 V DC (II) Fault. Zone 0, 1, 2 Div.

LMP 308. Separable Stainless Steel Probe. Stainless Steel Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO / 0.

Linear Luminaire with LED Series 6412/5

SIWAREX JB Aluminum Housing. Instruction Manual Edition 03/2006

Safety Instructions Micropilot FMR56/57

Barriers. EB3N Discrete Input Barrier with Redundant Output

4 Remote I/O. Digital Output Module 8-Channel Version Type 9475/ from Rev. F

Digital Output Module 8-Channel Version for Zone 2 Series 9475/

Safety Instructions Micropilot FMR50/51/52/53/54/56/57

Signal processor MS96 for flow sensors MS96-11EX0-R/230VAC

Certificate of Conformity

Emergency power supply NV2.1-12iaE

Digital Output Module 4-Channel Version for Zone 1 Series 9475/

Digital Output Module 8-Channel Version for Zone 1 Series 9475/

Inductive sensor with analog output BI15-M30-LI-EXI

Safety instructions. IECEx TUN Ex ia IIC T6 Gb

4 Remote I/O. Analog Output Module HART Ex i / I.S. Outputs, 8 Channels Series 9466/12

Safety Instructions Cerabar S PMP71, PMP75

IECEx Certificate of Conformity

IECEx Certificate of Conformity

Junction Boxes & Enclosures JBEP and ECEP Series: Undrilled Fiberglass Reinforced Polyester Enclosures Increased Safety

PROCESS AUTOMATION INSTRUCTION MANUAL FIELDBUS SURGE PROTECTOR F*-LBF-I1.32 F*-LBF-D1.32

FieldIT Multi Barrier NMB204/NMB204-EX (MB 204/MB 204-Ex)

Flow Measurement SITRANS F M. Transmitter MAG 6000 I/6000 I Ex de. 3/46 Siemens FI

Guided Wave Radar Level and Interface Transmitter

MANUAL Surge Protectors

TFR5. Room or outdoor temperature sensor. Operating instructions for temperature sensor. English page 1...5

RACON short-travel keyswitches

Instruction Manual. T3110 T3110L T3110Ex

Sensor boxes SRBC. Festo core product range Covers 80% of your automation tasks

Interface and Supply module. IPC 3x0i / PSC 3x0i

Safety Instructions Cerabar M PMC51, PMP51, PMP55

Installation & Operation Manual

Certificate of Conformity Ex EQUIPMENT

Digital Output Module 4-Channel Version for Zone 1 Series 9475/

Barriers. Discrete Output Barrier

Digital Output Module 8-Channel Version for Zone 2 Series 9475/

FLEX Ex Spring Clamp Terminal Base

Safety instructions Overvoltage protection B81-35

SMARTLINE RM76 Supplementary instructions

KINAX WT720 absolute, programmable angular postion transmitter

Safety Instructions Levelflex FMP50/51/52/53/54/55/56/57

MODEL SW6000 & SM6100 CENELEC INSTRUCTIONS

Intrinsically Safe Explosion Proof Barriers

How to calculate an Intrinsically Safe loop approval.

Installing PRO/DGX or Pro Soloist MIDI interface. R Grieb 9/08/2017

Inductive sensor For rotary actuators NI4-DSU35TC-2Y1X2/S933

General Specifications

Dishmachine Division Please call for pricing or

masterelectronics.com onlinecomponents.com

Assembly MAU. MUX 4 Channels 8 Channels Zone 1

IECEx Certificate of Conformity

IECEx Certificate of Conformity

PHOENIX CONTACT Pin. SUBCON-PLUS M ARCNET, MULTI/MININET (B&R), SYSTEM 2003 (B&R), P-NET SUCONET K1, K2 (EATON/Moeller),

Emergency Luminaire for Fluorescent Lamps Series EXLUX 6009

Intrinsically safe batch controller Batching Master 110i

SITRANS F C. Transmitter MASS 6000 Ex d compact/remote 3/195

I Ex-Installation switch I

GV-EL124S Electric Strike

BA488CF-P PROFIBUS PA Intrinsically safe Panel mounting Fieldbus Display issue 3

Inductive Angle Sensor With Analog Output RI360P1-DSU35TC-ELI-EXI

Termination Board. HiCTB08-SCT-44C-SC-RA. Features. Assembly. Function. Connection. 24 V DC (I), 24 V DC (II), Fault. Zone 0, 1, 2 Div.

INSTALLATION INSTRUCTIONS. FST-420 Fiber Station Transceiver

IECEx Certificate of Conformity

THE BARRIER and the Universal Barrier Cabinets from Pepperl+Fuchs

PROCESS AUTOMATION YOUR PARTNER FOR INDUSTRY-SPECIFIC INSTALLATION SOLUTIONS FIELD JUNCTION BOX

IEEE Mb/s single twisted pair Ethernet for Process Industry

Certificate of Conformity

Guide for installers. METTLER TOLEDO MultiRange Explosion-protected weighing system with the ID7sx weighing terminal

Termination Board FC-GPCS-RIO16-PF. Features. Assembly. Function. Connection USIO/UPIO 24 V DC (I), 24 V DC (II) Fault. Zone 0, 1, 2 Div.

Diffuse reflection light scanner with background suppression. Dimensioned drawing

Micro Motion, Inc. Page 1 of 6

IECEx Certificate of Conformity

PHOENIX CONTACT - 01/2008

Inductive dual sensor For rotary actuators NI4-DSU35TC-2Y1X2/S933

Transcription:

for Certificate No.: IECEx TSA 07.0056X Issue No.: 2 Drawing list pertaining to Issue 0 of this Certificate: 1909ME 5 Cardrack Assy 5 2000/04/10 1914ME 1 Keyboard for 18 switch EXE810 1 1999/03/13 1915ME 1 Switch Panel for 18 switch EXE810 7 2001/06/14 1920ME 1 Switch Plunger for EXE810 7 2001/04/19 1922ME 1 Window Glass 1 1998/12/17 1923ME 1 Window Retaining Plate 5 2000/06/13 1924ME 1 Display Window for EXE810 - Cut 1 1999/03/13 1925ME 1 Switch Spring for EXE810 2 2000/02/11 1926ME 1 W & M Switch Plunger for EXE810 8 2001/05/24 1927ME 1 W & M Spring/Actuator for EXE810 2 2000/02/14 1928ME 1 W & M Switch bracket 5 2000/09/18 1929ME 1 Reader Gland for EXE810 4 2000/09/21 1930ME 1 EX810 Door PCB Mounting Plate 3.0 2000/08/08 1932ME 1 Stand-Off x 20 2 1998/12/10 1933ME 1 Reader Surround 2 2000/02/14 1934ME 1 Reader Insulating Bush A 2 2000/02/14 1935ME 1 Reader Head 4 2000/09/29 1936ME 1 Reader Stepped Insulating Washer 2 2000/02/14 1937ME 1 Reader Insulating Washer 1 1999/03/13 1938ME 1 Reader Insulating Bush B 1 1999/03/13 1939ME 4 EXE810-5 Assembly 10 2004/03/13 1940ME 4 EXE810-18 Assembly 10 2004/03/13 1941ME 1 Assy Reader Gland for EXE810 1.2 2000/02/11 1948FA 1 SFP EXE810-Window-Printed 2 1999/03/20 1949ME 1 Gland Seal Plug for EXE810 2 2000/02/11 1950ME 1 Keyboard for 5 Switch EXE810 1 1999/03/15 1953ME 1 Switch Plate for 5 Switches 7 2001/06/14 1955ME 1 Blanking Plate for Reader Hole 3 2000/09/21 1956ME 1 Hinge Pin for EXE810 Enclosure 1 1999/03/13 1957ME 4 EXE410 Assembly 7 2004/03/14 1958ME 3 Mounting Plate for EXE410 3 2000/09/13 1959ME 1 Switch Panel for EXE410 3 2000/09/18 1960ME 1 Keyboard for EXE410 1 1999/03/13 1961ME 1 Blank Switch Plunger for EXE410 5 2000/11/09 1980ME 2 Body Casting Details for EXE410 4 2000/04/02 1982ME 2 Body Casting Details for EXE810 4 2000/04/02 1984ME 1 Lid Casting-EXE410 & 810 Casting details 2 1999/04/20 1985ME 1 EXE810-5 Switch Lid Machine details 8 2000/07/12 1986ME 1 EXE810-18 Switch Lid Machine details 8 2000/07/12 2023ME 1 Switch washer 3 2000/12/07 Page 1 of 5

for Certificate No.: IECEx TSA 07.0056X Issue No.: 2 2042ME 1 Large Plunger Button for EX810 5 2000/07/25 2054ME 2 Body for EXE810 with M25 Glands machining details 9 2004/03/13 2095ME 2 EXE 410 body Machining Details 3 x M20 5 2004/03/13 2159ME 1 Hinge Spacer for EXE810 1 2000/02/09 2234ME 1 Switch Button Small for EXE810 3 2001/06/14 2235ME 1 Switch Button Large for EXE810 3 2001/06/14 2242ME 1 Blank Switch Panel for 810 1 2000/12/07 2265ME 1 Switch Button Cover 1 2001/06/14 2030CD 1 Touch Memory Assoc. Apparatus 4.0 2004/03/04 2038PA 3 Board Layout for S810TKIS 4.0 2004/03/04 2039PL 1 Parts List for 810TKIS 4.0 2004/03/04 2035ID 2 Touch Key Installation With 810TKIS 1.0 1999/04/26 2040ME 1 Specifications for 810TKIS 1.0 1999/04/26 1354ID 1 Termination of The Shielded Twisted Pair Cable 1.0 1993/01/21 2577PL 1 Label for IECEx Ex 410 Enclosure 1.1 2008/01/31 2578PL 1 Label for IECEx Ex 810 Enclosure 1.1 2008/01/31 Conditions of Certification pertaining to Issue 0 of this Certificate: 1. It is a condition of manufacture that each enclosure shall be subject to a static pressure test in accordance with clause 16 of IEC 60079-1:2001 using a minimum test pressure of 13.5 bar applied for more than 10 seconds. 2. It is a condition of safe use that the maximum voltage that may be connected to the non-intrinsically safe connections of the Touch Key Barrier is Um = 250 V. 3. It is a condition of safe use that the intrinsically safe Touch Key Reader connector has the following input and output parameters, and these shall be taken into account during installation: Maximum input voltage U i Maximum input power P i Maximum internal capacitance C i Maximum internal inductance L i Maximum output voltage U o Maximum output current I o Maximum external capacitance C o Maximum external inductance L o 0.24 W 125 μf 0 μh 0.1 ma 500 μf 7 mh Variation permitted in Issue 1: This is supplementary to the earlier certificate IECEx TSA 07.0056X Issue 0. The equipment has not changed, but the description of the equipment has now been revised to provide the model names and numbers Load Computer 1010A4-CJ and Access Terminal 1030A0-GC instead of just the enclosure number EXE810. Page 2 of 5

for Certificate No.: IECEx TSA 07.0056X Issue No.: 2 The revised Ex code will be: Ex d ia IIB T6 for both the Load Computer 1010A4-CJ and Access Terminal 1030A0-GC with Touch Key Reader and Touch Key Barrier Ex d IIB T6 for both the Load Computer 1010A4-CJ and Access Terminal 1030A0-GC without Touch Key Reader and Touch Key Barrier in standard atmospheric pressure and for ambient temperatures 40 C to 60 C. Drawing list pertaining to Issue 1 of this Certificate: 1909ME 5 Cardrack Assy 5 2000/04/10 1914ME 1 Keyboard for 18 switch EXE810 1 1999/03/13 1915ME 1 Switch Panel for 18 switch EXE810 7 2001/06/14 1920ME 1 Switch Plunger for EXE810 7 2001/04/19 1922ME 1 Window Glass 1 1998/12/17 1923ME 1 Window Retaining Plate 5 2000/06/13 1924ME 1 Display Window for EXE810 - Cut 1 1999/03/13 1925ME 1 Switch Spring for EXE810 2 2000/02/11 1926ME 1 W & M Switch Plunger for EXE810 8 2001/05/24 1927ME 1 W & M Spring/Actuator for EXE810 2 2000/02/14 1928ME 1 W & M Switch bracket 5 2000/09/18 1929ME 1 Reader Gland for EXE810 4 2000/09/21 1930ME 1 EX810 Door PCB Mounting Plate 3.0 2000/08/08 1932ME 1 Stand-Off x 20 2 1998/12/10 1933ME 1 Reader Surround 2 2000/02/14 1934ME 1 Reader Insulating Bush A 2 2000/02/14 1935ME 1 Reader Head 4 2000/09/29 1936ME 1 Reader Stepped Insulating Washer 2 2000/02/14 1937ME 1 Reader Insulating Washer 1 1999/03/13 1938ME 1 Reader Insulating Bush B 1 1999/03/13 1939ME 4 EXE810-5 Assembly 10 2004/03/13 1940ME 4 EXE810-18 Assembly 10 2004/03/13 1941ME 1 Assy Reader Gland for EXE810 1.2 2000/02/11 1948FA 1 SFP EXE810-Window-Printed 2 1999/03/20 1949ME 1 Gland Seal Plug for EXE810 2 2000/02/11 1950ME 1 Keyboard for 5 Switch EXE810 1 1999/03/15 1953ME 1 Switch Plate for 5 Switches 7 2001/06/14 1955ME 1 Blanking Plate for Reader Hole 3 2000/09/21 1956ME 1 Hinge Pin for EXE810 Enclosure 1 1999/03/13 1982ME 2 Body Casting Details for EXE810 4 2000/04/02 1984ME 1 Lid Casting-EXE410 & 810 Casting details 2 1999/04/20 1985ME 1 EXE810-5 Switch Lid Machine details 8 2000/07/12 Page 3 of 5

for Certificate No.: IECEx TSA 07.0056X Issue No.: 2 1986ME 1 EXE810-18 Switch Lid Machine details 8 2000/07/12 2023ME 1 Switch washer 3 2000/12/07 2042ME 1 Large Plunger Button for EX810 5 2000/07/25 2054ME 2 Body for EXE810 with M25 Glands machining details 9 2004/03/13 2095ME 2 EXE 410 body Machining Details 3 x M20 5 2004/03/13 2159ME 1 Hinge Spacer for EXE810 1 2000/02/09 2234ME 1 Switch Button Small for EXE810 3 2001/06/14 2235ME 1 Switch Button Large for EXE810 3 2001/06/14 2242ME 1 Blank Switch Panel for 810 1 2000/12/07 2265ME 1 Switch Button Cover 1 2001/06/14 2030CD 1 Touch Memory Assoc. Apparatus 4.0 2004/03/04 2038PA 3 Board Layout for S810TKIS 4.0 2004/03/04 2039PL 1 Parts List for 810TKIS 4.0 2004/03/04 2035ID 2 Touch Key Installation With 810TKIS 1.0 1999/04/26 2040ME 1 Specifications for 810TKIS 1.0 1999/04/26 1354ID 1 Termination of The Shielded Twisted Pair Cable 1.0 1993/01/21 Note: Above drawings were listed on AU/TSA/ExTR07.0060/00 2578PL-1 1 Label for IECEX Ex 810 Enclosure 1.0 2008/09/09 1030A0-GC 3 Internal Equipment Location Drawing For EX810 A1 2008/06/26 Enclosure 1010A4-CJ 3 Internal Equipment Location Drawing For EX810 Enclosure A1 2008/06/26 Conditions of Certification pertaining to Issue 1 of this Certificate: 1. It is a condition of manufacture that each enclosure shall be subject to a static pressure test in accordance with clause 16 of IEC 60079-1:2001 using a minimum test pressure of 13.5 bar applied for more than 10 seconds. 2. It is a condition of safe use that the maximum voltage that may be connected to the non-intrinsically safe connections of the Load Computer 1010A4-CJ and Access Terminal 1030A0-GC is U m = 250 V. 3. It is a condition of safe use that the following input and output parameters shall be taken into account during installation: The Touch Key Barrier has the following output parameters: Maximum output voltage U o Maximum output current I o Maximum external capacitance C o Maximum external inductance L o 0.1 ma 125 μf 7 mh Page 4 of 5

for Certificate No.: IECEx TSA 07.0056X Issue No.: 2 The intrinsically safe Touch Key Reader has the following input parameters: Maximum input voltage U i Maximum input power P i 0.24 W Maximum internal capacitance C i 0.001 μf Maximum internal inductance L i 0 μh Variation permitted in Issue 2: 1. The applicant name is changed from Contrec Pty Ltd to Honeywell Enraf Americas Inc. 2. The manufacturer name is changed from Contrec Pty Ltd to Honeywell Enraf Americas Inc. 3. Add new manufacture location in India. The quality assessment report for the manufacturer in India has been reviewed and accepted. Drawing list pertaining to Issue 2 of this Certificate: 2578PL-1 1 Label for IECEX Ex 810 Enclosure 1.2 2009/03/27 Conditions of Certification pertaining to Issue 2 of this Certificate: The conditions of certification are unchanged from the Issue 1 of the certificate. Page 5 of 5