POE084824B. PoE 54V/8x0,3A/4x7Ah PoE buffer power supply for up to 8 IP camera. v.1.1 EN* Edition: 7 from

Similar documents
BNC08128C. BNC 13,8V/8x1A/17Ah. Switch mode buffer power supply unit for CCTV. v.1.0 EN** Edition: 3 from

Features: S98-B v1.0 S98-B 9-port switch with buffer power supply for 8 IP cameras

Features: DSB98 v1.0 DIN rail mounted switch 9-port DSB98 with buffer power supply for 8 IP cameras

PSBOC PSBOC 27,6V/5,5A/OC

Features: DSFB108 v1.1 DIN rail mounted switch 10-ports DSFB108 with buffer power supply for 8 IP cameras

Features: SF108-CR v1.1 SF108-CR 10-ports switch for 8 IP cameras in enclosure with recorder space

Features: DS54 v1.0 DIN rail mounted switch 5-port DS54 for 4 IP cameras without power supply

Features: Example of use

EN54-7A17 v.1.1/iv EN54 27,6V/7A/2x17Ah power supply for fire alarm systems

v.1.1/iv EN54 27,6V/7A/2x40Ah power supply for fire alarm systems

v.1.1/vi PSBEN 27,6V/5A/2x17Ah/EN buffer, switched mode power supply unit Requirements of Grade 1 Grade 2 Grade 3

PSBEN 2012B/LCD v.1.0 PSBEN 13,8V/2A/7Ah/EN/LCD buffer, switched mode PSU. Requirements of. Grade 1 Grade 2 Grade 3

PSBEN 10A12E. PSBEN 13,8V/10A/65Ah/EN Buffer, switch mode power supply unit Grade 3.

v.1.1/vi PSBEN 27,6V/5A/2x17Ah/EN/LCD buffer, switched mode power supply unit Requirements of Grade 1 Grade 2 Grade 3

EN** PSBEN 10A12D v.1.1/vii PSBEN 13,8V/10A/40Ah/EN buffer, switch mode power supply unit Grade 3. Requirements of. Grade 1 Grade 2 Grade 3

PSBEN 2012B v.1.1/vii PSBEN 13,8V/2A/7Ah/EN buffer, switch mode power supply unit Grade 3. Requirements of. Grade 1 Grade 2 Grade 3

PSBEN 3012C. PSBEN 13,8V/3A/17Ah/EN Buffer, switched mode power supply unit.

Buffer power supply units. compliant with EN are intended to alarm system devices

Interface RS485-TTL CODE: INTR. v.1.0 EN* Edition: 3 from

EN54-2A17. EN54 27,6V/2A/2x17Ah power supply for fire alarm systems

Buffered Power Supply PS-30DR v1.0

PSBEN 5012D/LCD. PSBEN 13,8V/5A/40Ah/EN/LCD Buffer, switched mode power supply unit.

PSBEN 2012B/LCD. PSBEN 13,8V/2A/7Ah/EN/LCD Buffer, switched mode power supply unit.

Installation Manual for D244X Series 24-volt Power Supplies

RTT2 ROOM TEMPERATURE SWITCH. Mounting and operating instructions

60W Power over Ethernet Waterproof Adapter PoE IEEE BT Single Port Injector for Outdoor Application

Ferrous metal (The sensing distance decreases with non-ferrous metal.) Power supply voltage (operating voltage range)

QUALITY POWER SOLUTIONS BACKED UP BY REAL-WORLD ENGINEERING EXPERIENCE

CliQ II DC-UPS Module 24V 40A / DRU-24V40ABN

Application Package Dimension Output Input Output Output Protection Option Code Code Power Voltage Quantity Voltage Type (W) (VAC) (VDC)

Switching Power Supply

RТTH DUAL ROOM SWITCH

POWER SUPPLY SYSTEM DSO 24V FOR PAVIRO SYSTEM BY BOSCH

RXTP ROOM TEMPERATURE

TSP-BCM48, TSP-BCM48A. Operating Instruction Manual. Page 1 of 13

The Programmable 4-Way Relay Card is an optional peripheral unit that provides four individually programmable relay output circuits.

Mini Digital Multimeter

Interface WI-FI CODE: INTW. v.1.0. Edition: 2 from Supersedes the: 1 from edition

NTP-5521/5531/5561 SWITCHING MODE POWER SUPPLY

PART NUMBER STRUCTURE. P-DUKE Technology Co., Ltd Page 1

DXTH DUCT SENSOR / SWITCH FOR TEMPERATURE AND HUMIDITY. Mounting and operating instructions

IGLOO IGLOO EASY INSTRUCTION MANUAL

2 in 1 LAN Tester and Multimeter Model:

PART NUMBER STRUCTURE. P-DUKE Technology Co., Ltd Page 1

Rhino PSM Power Supplies. Operating Instructions

Industrial Power Supplies

Industrial 5-Port Fast Ethernet Switches. with SFP Slot and optional 4 PoE PSE Ports. Basic Model: KSD-541. PoE Model: KSD-541-HP. Installation Guide

HCS-3600 / 3602 / 3604 Laboratory Grade & High RFI Immunity Switching Mode Power Supply with Rotary Encoder Control

Industrial Power Supplies

1 Description. 2 Specifications. Product Installation Document. Honeywell 12 Clintonville Road Northford, CT

Mini Digital Multimeter

ADC7520 SERIES. 1600W Battery Chargers and Power Supplies

Rhino Buffer Module PSM24-BFM600S. Operating Instructions

RST ROOM TEMPERATURE TRANSMITTER. Mounting and operating instructions

3000W Programmable Single Output AEK AEK AEK AEK

Industrial 5-Port Fast Ethernet Switches with SFP Slot and optional 4 PoE PSE Ports. Basic Model: KSD-541 PoE Model: KSD-541-P. Installation Guide

is then retained absolutely without interruption.

IGLOO IGLOO EASY INSTRUCTION MANUAL

SIM-9106/9303 High Current Switching Mode Power Supply with C.C., C.V., Remote Control & Sensing User Manual

Access Control System - Installation Guide

Expandable Power Systems

RXTH DUAL ROOM SENSOR / SWITCH

THOR Battery Backed DC Power Supply Reference Manual

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

Model HM-535 Power Supply Installation and Service Instructions

M-bus web server. Meters and Energy Cost Allocation WTV676-HB6035

Display Panel BAT 100 LSN. en Operation Guide

Mid-span 802.3af PoE Injector. Installation Guide KPOE-100

Industrial 6-port unmanaged Gigabit PoE Ethernet switch with 4x10/100/1000Base-T(X) P.S.E. and

Installation Manual for D155X Series of 12V Switched Mode Power Supply for Access Control

Artistic Licence. Rail-Switch II. User Guide. Rail-Switch II User Guide. Version 5-5

E2A. Ordering Information. Cylindrical Proximity Sensor. Safe Mounting with Greater Sensing Distance. E2A Cylindrical Proximity Sensor 1

MCX402DR-BRD I/O expander. Operating Manual

PHOENIX CONTACT - 01/2010. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.

Optimum sensing capability for LCD manufacturing

Model (DRS-54V) Ver. 2.0 August. Dongah Rectifier System Operating Manual

Fiber optic converter audio and CAN TA OPERATION MANUAL

IST ULTRASTAB Power Supply for high precision transducers

Installation Sensing distance Connection Output configuration Operation mode NO Operation mode NC

Switched Mode Power Supply Operating manual PAP800

Nokeval. FD100 series. User Manual

TM221CE40T controller M IO transistor PNP Ethernet

ABL8BBU24200 battery control module V DC - 24 V - 20 A - for regulated SMPS

RTU500 series Data Sheet Power Supply CP-E 24/2.5

SPECIFICATIONS. Input Output Agency Approvals 0 ~ 62.5A. toll-free (603)

Mini Digital Multimeter Model MN15. User's Guide

PTC-101-M12 Hardware Installation Guide

Safety Standards. Model Number:

Installation Instructions H Series

DC Outdoor Power Supply/Chargers

UC-2000 Installation Manual Unicorn Computers Technology Limited

LOGIC CONTROLLER INSTALLATION MANUAL NTR 756 B /E

Albatros 2 Grid supervision module / PSU User manual. AVS76.39x/309. Infrastructure & Cities. Edition 2.1

ISO 9001 CERTIFIED. 607 NW 27th Ave Ocala, FL Phone: (352) or Fax: (352) OPERATION MANUAL

Thread length (overall length) material

MODEL: M5DY SEN TRONIC AG CURRENT LOOP SUPPLY. [2] POWER INPUT AC Power M: V AC (Operational voltage range V, Hz)

EX-RC1 Remote I/O Adapter

Chrome DC-UPS Module 24V 10A / DRU-24V10ACZ

PMT. Model Number: CC Code PM 24V 200W 1 A Panel Mount Product Type T Enclosed L L Frame*

Accessories and options

Transcription:

POE084824B v.1.1 PoE 54V/8x0,3A/4x7Ah PoE buffer power supply for up to 8 IP camera. EN* Edition: 7 from 15.11.2017 Supersedes the edition: 6 from 22.11.2016 GREEN POWER CCTV PoE

PSU features: DC 54V uninterruptible power supply to 8 cameras IP battery housing: 4x7Ah/12V Wide range of AC supply voltage: 176 264V High efficiency: 86% battery charging and maintenance control deep discharge battery protection (UVP) battery output protection against short circuit and reverse connection designed for 10Mbit/s and 100Mbit/s network Voltage control at the AUX1 AUX8 outputs jumper selectable battery charge current 0,5A/1A Approximate backup time: 4h 36min FPS technical output indication of the output fuse activation relay and OC type LED optical indication protections: SCP short-circuit protection OVP overvoltage protection Surge protection Antisabotage protection OLP overload protection Mounting plate for mounting the network switch - Ethernet Switch / Hub warranty 2 year from the production date Example of power supply of up 8 IP cameras. 54V DC/8 x 0,3A TABLE OF CONTENTS: 1. Technical description. 1.1. General description 1.2. Block diagram 1.3. Description of components and connectors of the PSU 1.4. Technical parameters 2. Installation. 2.1. Requirements 2.2. Installation procedure 3. Power supply operation indication. 3.1. Optical indication 3.2. Technical outputs 4. Service and operation. 4.1. Overload or short-circuit of the power supply output 4.2. Battery operation 4.3. Maintenance 2

1. Technical description. 1.1. General description. The PSU is designed for supply of up to 8 webcams requiring stabilized voltage of 48V DC(+/-15%). The PSU supplies voltage of 54V DC and total current capacity of: 1. Output current 8x0,3A + 0,5A battery charge* 2. Output current 8x0,2A + 1A battery charge* Total device current + battery: 2,8A max *. In case of mains power loss, the unit will instantly switch to battery operation. The approximate backup time is given assuming that all output ports are used (using typical devices and 7Ah batteries). The electricity consumption for own needs and the energy efficiency of the power intake track were taken into account. The exact description of how to perform the calculations can be found at: "Approximate backup time - assumptions for calculations". There are 8 power supply outputs, independently protected by melting fuses or PTC polymer fuses. Failure (short circuit) in the output circuit will activate the melting fuse or PTC fuse and disconnect the circuit from DC power (+ U). Fuse failure is indicated by switching off the corresponding LEDs: L1 for AUX1, etc. In addition, the FPS output (hi-z state) and L FPS LED are activated and the relay contacts change their position. The PSU is housed in a metal enclosure with signaling panel equipped with a microswitch indicating door opening (front cover). The power is carried over the spare pairs (4/5 & 7/8), which, according to the Ethernet network standard, are not used for data transmission (data transmission uses 1/2 and 3/6 data pairs). The PSU can not be used in Gigabit Ethernet networks, where all twisted pairs are involved in the transmission of data! 1.2. Block diagram. Fig. 1. Block diagram of the PSU. 1.3. The description of components and connectors of the PSU. Table 1. Component No. [Fig. 2] [1], [10] [2] Description LED optical indication: green L IN indication of voltage at the IN input red L AC AC voltage indication red L FPS FPS failure indication Connector: IN power supply of the module (factory setting) AC 230V mains supply indication input [3] F1 F8 fuses in the AUX1 AUX8 (+), F500mA circuits [4] Jumper to select melting fuse or PTC polymer fuse [5] Green LED L1 L8 - voltage indication at the AUX outputs (during normal operation, * Refer to chart 1 3

these LEDs are on) [6] Network outputs (Ethernet + power supply) for camera connection [7] Network inputs (Ethernet) [8] FPS technical output indicating failure OC type [9] FPS technical output indicating failure relay type [11] Optional, external optical indication connector (factory setting) [12] PE grounding the shield of the RJ45 connectors (factory setting) Table 1. The description of components of the PoE module. Fig. 2. Components arrangement. Fig. 3. The view of the PSU. 4

Component No. [Fig. 3] [1] The module of the switch mode PSU Description [2] LED light indicating correct operation of the switch mode PSU [3] ADJ potentiometer regulation of the power supply output voltage [4] PoE module [5] Connectors for connecting the batteries: +BAT = red, - BAT = black [6] TAMPER microswitch (contacts) of antisabotage protection (NC) [7] Plate for mounting the network switch (Ethernet switch / hub) [8] 1.4 Technical parameters. - electrical parameters (Table 3) - mechanical parameters (Table 4) - safety of use (Table 5) - operation parameters (Table 6) Selection jumper for charging current: Ibat =0,5A Ibat =1A Legend: jumper installed, jumper removed. Factory settings: Ibat =0,5A (jumper installed). Tab. 2. Components of the PSU (see Fig. 3). Electrical parameters (Table 3). Mains supply 176 264V AC Current consumption 1,5A@230V AC type PSU s power 155W max. Efficiency 86% Output voltage 44V 54V DC buffer operation 38V 54V DC battery operation The adjustment range of the output voltage 48 56V DC Output current t AMB <30 C 8 x 0,3A see diagram 1 Output current t AMB =40 C 8 x 0,21A see diagram 1 Ripple voltage 150 mv p-p max. Current consumption by the PSU 0,1A Battery charging current 0,5A /1A - jumper selectable Approximate backup time 4h 36min Short-circuit protection SCP PoE MODULE 8 x F 0,5A or 8 x PTC 0,5A (jumper selectable) PSU MODULE 105% 150% of PSU power, automatic recovery Overload protection OLP 105% 150% of PSU power, automatic recovery Battery circuit protection SCP and reverse polarity connection polymer fuse Overvoltage protection OVP U>115% 150% of the output voltage - disconnection of the output voltage, automatic return Deep discharge battery protection UVP U<38V (± 5%) disconnecting the battery terminal Surge protection 8 x varistor Antisabotage protection: - TAMPER output indicating enclosure opening - microswitch, NC contacts (enclosure closed), 0,5A@50V DC (max.) Optical indication of operation: YES LED lights Technical outputs: - FPS technical output indicating output fuse activation - OC type, 50mA max. Normal operation: L state (0V), failure: H state (hi-z), (automatic return once the normal operation is restored) - relay type: 1A@ 30VDC/50VAC, delay time: approximately 10 seconds F1 F8 fuses F 0,5A or PTC 0,5A 5

Mechanical parameters (Table 4). Dimensions W=300, H=407, D=127, D 1 =15 [+/- 2mm] W 1 =305, H 1 =410 [+/- 2mm] Mounting plate dimensions W 2 =260, H 2 =127 [+/- 2mm] Operating space D 2 =48 [+/- 2mm] The dimensions of the 250x165x105mm (WxHxD) max battery compartment Mounting See Fig. 3 Net weight 5,1kg / 5,4kg Enclosure DC01 steel plate, 1,0mm, RAL 9003 Closing Cylindrical screw x 2 (at the front), lock assembly possible Terminals Switch mode power supply: Φ0,4-2,5 (AWG 26-10) PoE module: Φ0,5-2,1 (AWG 24-12) AUX1...8 outputs: RJ45 8pin TAMPER output: Φ0,8 Notes The enclosure has a 15mm distance from the mounting surface so the cables can be led. Safety of use (Table 5). Protection class PN-EN 60950-1:2007 I (first) Protection grade PN-EN 60529: 2002 (U) IP20 Insulation electrical strength: - between input (network) circuit and the output circuits of the PSU (I/P-O/P) 3000V/AC min. - between input circuit and PE protection circuit (I/P-FG) 1500V/AC min. - between output circuit and PE protection circuit (O/P-FG) 500V/AC min. Insulation resistance: - between input circuit and output or protection circuit 100 MΩ, 500V/DC Operation parameters (Table 6). Operating temperature Storing temperature Relative humidity Vibrations during operation Surges during operation Direct insolation Vibrations and surges during transport -10ºC...+40ºC (see Figure1) -20ºC...+60ºC 20%...90%, no condensation unacceptable unacceptable unacceptable According to the PN-83/T-42106 standard Diagram 1. Maximum permissible output current depending on ambient temperature. 6

2. Installation. 2.1. Requirements. The buffer PSU should be mounted by a qualified installer, holding relevant permits and licenses (applicable and required for a given country) for 230V/AC and low-voltage installations. The unit should be mounted in confined spaces, in accordance with the 2nd environmental class, with normal relative humidity (RH=90% maximum, no condensation) and temperature range from -10 C up to +40 C. The power supply should operate in a vertical position in order to provide free and convectional air flow through ventilating holes of the enclosure. Before installation, prepare a PSU load balance. 1. Output current 8x0,3A + 0,5A battery charge* 2. Output current 8x0,2A + 1A battery charge* Total device current + battery: 2,8 max *. The power supply is designed for a continuous operation and is not equipped with a power-switch. Therefore, an appropriate overload protection in the power supply circuit should be provided. Moreover, the user should be informed how to disconnect the power supply unit from the mains supply (usually by assigning an appropriate fuse in the fuse box). The electrical system shall be made in accordance with applicable standards and regulations. The PSU is designed for 10Mbit/s and 100Mbit/s Ethernet network (so-called Fast Ethernet). However, it can not be used for a 1000 Mbit/s network (so-called Gigabit Ethernet). Connections between the power supply and the camera can be done using UTP-3 cable (networks with data-rates up to 10 Mbit/s) or UTP-5 cable. Due to the lower resistance wiring, it is recommended (especially at large distances between the power supply and receivers) to use UTP- 5 cable also for networks with data-rates up to 10 Mbit/s. 2.2. Installation procedure. 1. Before installation, cut off the voltage in the 230V power-supply circuit. 2. Mount the PSU in a selected location and lead the connecting cables. 3. If required, mount the switch network (Ethernet Switch / Hub) on the mounting plate (element 6, Figure 3) using cable ties supplied with the PSU. An example of mounting the Ethernet switch is shown in Figure 4: Figure 4. An example of mounting the Ethernet switch. 4. Connect the power cables (230V AC) to L-N terminals of the PSU. Connect the ground wire to the terminal marked with grounding symbol:. Use a three-core cable (with a yellow and green PE protection wire) to make the connection. The power cables should be connected to the appropriate terminals on the connection board through the bushing. The shock protection circuit shall be done with a particular care: the yellow and green wire coat of the power cable should be connected to the terminal marked with the symbol in the PSU enclosure. Operation of the PSU without the properly made and fully operational shock protection circuit is UNACCEPTABLE! It can cause damage to the equipment or an electric shock. 5. Connect the network cables (Ethernet) to the PoE module: supply voltage is present only at the AUX sockets and the cameras should be connected to them. Pin assignment of the AUX and IN sockets is shown in the Figure 5: * Refer to chart 1 7

Fig. 5. Connection of cameras and network devices to the IN and AUX terminals. 6. Use the F1/PTC1 F8/PTC8 jumpers to select the type of short circuit / overload protection of individual circuits. Jumper in the Fx position melting fuse activation, PTCx PTC fuse activation. 7. If needed, the following technical connections can be made: - FPS technical output of the PSU status indicates the voltage loss at any of the outputs (AUX1 AUX8). - TAMPER indicating enclosure opening. 8. Check the power supply output voltage: - output voltage of the unloaded power supply without a battery should amount to U=54V DC. 9. Connect the batteries in series according to the color markings: - battery output (+V): BAT+ cable/ red - battery output (0V): BAT- cable / black 10. Check the optical indication of the PSU status: green LED light on the PoE module. 11. Close the cover after installing and checking the operation of the power supply. 3. Power supply operation indication. 3.1. Optical indication. The PSU has 11 LED lights at the front panel: RED LED: on The PSU supplied with 230V AC voltage off no 230V AC mains supply RED LED: on DC voltage at the output of the switch mode PSU off no DC voltage at the output of the switch mode PSU RED LED: on fuse failure at one of the AUX1 AUX8 outputs off no failure GREEN LED: on DC voltage at the AUX1 AUX8 output off no DC voltage at the AUX1 AUX8 output Additionally, the PSU is fitted with LED lights inside the enclosure see Fig. 2 and 3: - L AC red LED (Fig. 2, component 1) is permanently illuminated during normal operation (AC power ON). No AC power is indicated by turning off the L AC LED. - L IN green LED (Fig. 2, component 1) indicates DC voltage at the PoE module input. During normal operation (DC supply) the LED is permanently illuminated. No DC no DC voltage at the module input is indicated by turning off the L IN LED. - L FPS red LED (Fig. 2, component 10) is not illuminated during normal operation (no failure). In case of activation of the short circuit / overload protection at any output, the LED is permanently illuminated. - L1 L8 green LEDs (Fig. 2, component 5) indicate voltage at the individual outputs of the module (L1 for AUX 1 etc.). Activation of the short circuit / overload protection of a given circuit is indicated by turning off one of the Lx LEDs. 8

3.2. Technical outputs. The PSU has the following indication outputs: FPS technical output of the PSU status: - OC type output indicating failure (short-circuit, overload). During normal operation, shorted to ground L state (0V). In case of power loss, the FPS technical output is switched into hi-z state (high impedance) at least at one of the AUX outputs. Fig. 6. Electrical diagram of the OC output. - relay output. In case of failure, relay contacts are switched automatically. Fig. 7. Electrical diagram of the relay output. CAUTION! The arrangement of contacts at the figure 7 shows a potential-free status of the relay, which is equivalent to a state with no voltage at any of the AUX1 AUX8 outputs. TAMPER output indicating enclosure opening: - volt free contact input indicating the status of the power supply doors, PSU closed: contacts closed (NC), PSU open: contacts open (NO). 4. Service and operation. 4.1. Overload or short-circuit of the power supply output. The AUX1 AUX8 outputs of the PSU are protected against short-circuit and overload by melting fuse inserts or PTC polymer fuses. (The Fx / PTCx jumper position determines which fuse is used). If the power supply load current exceeds Imax. (110% 150% @ 25 C of the PSU power), the output voltage is automatically disconnected, which is indicated by turning off the green LED. If the PTC polymer fuses are used, disconnect the load from the power supply output for approximately 1 minute to restore output voltage. (the time needed to cool down the PTC fuse). In case of melting fuse activation, it should be replaced with a fuse of the same type and of the same rated current. 4.2. Battery operation In case of mains power loss, the unit will instantly switch to battery operation. The power supply is equipped with a discharged battery disconnection system. If the battery voltage has dropped below 38V during the battery operation, the battery will be disconnected. 4.3. Maintenance. All maintenance procedures can be performed after disconnecting the power supply from the power network. The PSU does not require any specific maintenance; however, its interior should be cleaned with compressed air if used in dusty conditions. The battery status should be checked periodically. (battery capacity loss, too high internal resistance) batteries should be replaced. In case of fuse replacement, use only compatible replacement parts. 9

WEEE LABEL Waste electrical and electronic equipment must not be disposed of with normal household waste. According to the European Union WEEE Directive, waste electrical and electronic equipment should be disposed of separately from normal household waste. CAUTION! The power supply unit is adapted for cooperation with the sealed lead-acid batteries (SLA). After the operation period they must not be thrown but recycled according to the applicable law. Pulsar Siedlec 150, 32-744 Łapczyca, Poland Tel. (+48) 14-610-19-40, Fax. (+48) 14-610-19-50 E-mail: biuro@pulsar.pl, sales@pulsar.pl http:// www.pulsar.pl, www.zasilacze.pl 10